1 68-0063—3 J. H. • Rev. 6-95 • ©Honeywell Inc. 1995 L8104A,B,C,D Electr onic W ater Heater Contr ollers The L8104A,B,C,D Electronic Controllers pro- vide temperature control and ECO limit action for gas water heaters.
68-0063—3 2 L8104A,B,C,D SPECIFICATIONS • ORDERING INFORMATION Specif ications IMPORTANT: The specifications given in this publication do not include normal manufacturing tolerances. Therefore, this unit may not exactly match the listed specifications.
3 68-0063—3 L8104A,B,C,D SPECIFICATIONS DIMENSIONS: L8104: Fig. 1. L8104A,B: Fig. 2. L8104C,D: Fig. 3. APPROVALS: Underwriters Laboratories Inc. Component Recognized: File No. MP466, Guide No. MBPR2. American Gas Association Certified: Report No. 70-22A.
68-0063—3 4 L8104A,B,C,D SPECIFICATIONS ACCESSORIES: L8104A: 4074ENP Potentiometer Assembly: 199075A Poten- tiometer: Clockwise turn increases temperature, two 18 in. [46 cm] leadwires with 1/4 in. quick connects. Washer and nut. 4074ENS Potentiometer Assembly: 199053A Potenti- ometer: Counterclockwise turn increases tempera- ture, two 18 in.
5 68-0063—3 L8104A,B,C,D INSTALLATION Installation WHEN INSTALLING THIS PRODUCT… 1. Read these instructions carefully. Failure to follow them could damage the product or cause a hazardous condition. 2. Check the ratings given in the instructions and on the product to make sure the product is suitable for your application.
68-0063—3 6 L8104A,B,C,D INSTALLATION Fig. 5—L8104A with board-mounted potentiometer in a standing pilot application. M131C POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED. 1/4 IN. TAB TERMINALS (3). 3/16 IN. TAB TERMINALS (3).
7 68-0063—3 L8104A,B,C,D INSTALLATION Fig. 7—L8104B with remote potentiometer in a standing pilot application. Fig. 8—L8104B with board-mounted potentiometer in an electronic ignition application. M130C POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED.
68-0063—3 8 L8104A,B,C,D INSTALLATION Fig. 9—L8104C with remote-mounted potentiometer in an electronic ignition application. SENSING BULB WITH ECO SWITCH 1 2 3 SETPOINT POTENTIOMETER (SHOWN FROM BACK) L1 (HOT) L2 1 4 3 1 2 4 5 3 POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED.
9 68-0063—3 L8104A,B,C,D INSTALLATION Fig. 10—L8104D with remote-mounted potentiometer in an electronic ignition application SENSING BULB WITH ECO SWITCH 1 2 3 SETPOINT POTENTIOMETER (SHOWN FROM BACK) L1 (HOT) L2 1 4 3 1 2 4 5 3 POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED.
68-0063—3 10 L8104A,B,C,D SETTING AND CHECKOUT Setting and Check out SET CONTROL TEMPERATURE If the potentiometer is mounted on the control module, turn the selector knob to the desired temperature. If the potentiometer is remotely mounted, the position of the flat part of the shaft determines the approximate control temperature.
11 68-0063—3 L8104A,B,C,D SETTING AND CHECKOUT • OPERATION TABLE 2—THERMISTOR RESISTANCE AT VARIOUS TEMPERATURES IN CELSIUS. Operation L8104A,D When the temperature at the sensing bulb drops below the setting on the potentiometer, the relay contacts in the electronic control module make to open the gas control or turn on the ignition module.
68-0063—3 12 L8104A,B,C,D TROUBLESHOOTING DISCONNECT SENSOR LEADS FROM ELECTRONIC CONTROL MODULE AND MEASURE RESISTANCE OF SENSOR(S) WITH OHMMETER. IS RESISTANCE BETWEEN 700K AND 30K OHMS (SEE TABLE 1)? SENSOR(S) OK. DISCONNECT ECO LEADS AND MEASURE RESISTANCE WITH OHMMETER.
13 68-0063—3 L8104A,B,C,D TROUBLESHOOTING CHECK TRANSFORMER, 120V SUPPLY, CORRECT AS NECESSARY. IGNITION MODULE WAS IN LOCKOUT. OBSERVE FOR 2-3 CYCLES TO MAKE SURE SYSTEM IS OTHERWISE OK. SENSOR(S) MAY BE SHORTED OR OPEN. CHECK FOR LOOSE, BROKEN OR SHORTED WIRES.
68-0063—3 14 L8104A,B,C,D TROUBLESHOOTING CHECK TRANSFORMER, 120V SUPPLY, CORRECT AS NECESSARY. IGNITION MODULE WAS IN LOCKOUT. OBSERVE FOR 2-3 CYCLES TO MAKE SURE SYSTEM IS OTHERWISE OK. NO YES CHECK VOLTAGE AT 24V TERMINALS OF ELECTRONIC CONTROL MODULE.
15 68-0063—3 L8104A,B,C,D MATERIAL SAFETY DATA SHEET.
68-0063—3 16 L8104A,B,C,D MATERIAL SAFETY DATA SHEET.
17 68-0063—3 L8104A,B,C,D MATERIAL SAFETY DATA SHEET.
68-0063—3 18 L8104A,B,C,D MATERIAL SAFETY DATA SHEET.
19 68-0063—3 L8104A,B,C,D MATERIAL SAFETY DATA SHEET.
68-0063—3 20 L8104A,B,C,D MATERIAL SAFETY DATA SHEET Home and Building Control Home and Building Control Helping You Control Your World Honeywell Inc. Honeywell Limited—Honeywell Limitée 1985 Douglas Drive North 740 Ellesmere Road Golden Valley, MN 55422 Scarborough, Ontario M1P 2V9 Printed in U.
Ein wichtiger Punkt beim Kauf des Geräts Honeywell L8104D (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Honeywell L8104D noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Honeywell L8104D - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Honeywell L8104D reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Honeywell L8104D erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Honeywell L8104D besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Honeywell L8104D verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Honeywell L8104D. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Honeywell L8104D gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.