Benutzeranleitung / Produktwartung F90B des Produzenten Honeywell
Zur Seite of 24
PRODUCT DA T A The Honeywell Trademark is used under license from Honeywell Intellectual Properties, Inc. by Air-Pure Systems. Honeywell International Inc.
F90A,B SELF-CONT AINED COMMERCIAL ELECTRONIC AIR CLEANER 68-0103-6 Revised 11-07 2 ORDERING INFORMA TION If you have additional questions, need further information, or would like to comment on our products or services, please write or phone: 1. Y our local Honeywell Commercial Air Product s Distributor.
F90A,B SELF-CONT AINED COMMERCIAL ELECTRONIC AIR CLEANER 68-0103-6 Revised 11-07 3 Shipping and Installation Weight: Dimensions: See Figs. 1 and 2. Approvals: Underwriters Laboratories Inc. listed: File No. E30954, Guide No. AGGZ (120 V ac units only).
F90A,B SELF-CONT AINED COMMERCIAL ELECTRONIC AIR CLEANER 68-0103-6 Revised 11-07 4 The F90 is equipped with two standard light-emitting diodes (LEDs) and one optional LED. ON LED: Lights when the solid st ate power supply is powered and operating normally .
F90A,B SELF-CONT AINED COMMERCIAL ELECTRONIC AIR CLEANER 68-0103-6 Revised 11-07 5 STAGE DANCE FLOOR T A B L E S BAR LOW SMOKING LEVEL AT STAGE AND DANCE FLOOR. USE ONE F90. HEAVY SMOKING LEVEL AT TABLES AND BAR. USE THREE F90s. M1528A F90 F90 F90 F90 F90 F90 F90 F90 F90 F90 Fig.
F90A,B SELF-CONT AINED COMMERCIAL ELECTRONIC AIR CLEANER 68-0103-6 Revised 11-07 6 Example 2. Sizing by Occupant Load A cocktail lounge averages 85 occupants. How many F90As should be installed? Solution: F90As Required = ASHRAE Recommended Air Circulation/Minute F90A Capacity 1.
F90A,B SELF-CONT AINED COMMERCIAL ELECTRONIC AIR CLEANER 68-0103-6 Revised 11-07 7 CAUTION Do not connect the power supply until F90 is mounted. If the F90 is powered before an electrical check, be extremely careful to avoid electrical shock. Also, take care when working near the F90 moving part s.
F90A,B SELF-CONT AINED COMMERCIAL ELECTRONIC AIR CLEANER 68-0103-6 Revised 11-07 8 1. LOCA TE WASH LED CUTOUT BEHIND SWITCH COVER ASSEMBL Y STICKER. 2. USE A KNIFE TO CUT A HOLE IN THE STICKER. 3. PUSH LED LENS INTO PLACE. 4. INSERT LED INTO LENS FROM BACK OF THE SWITCH COVER ASSEMBL Y .
F90A,B SELF-CONT AINED COMMERCIAL ELECTRONIC AIR CLEANER 68-0103-6 Revised 11-07 9 Fig. 7. F90 installation dimensions in in. (mm). M920 29-1/4 (743) 8 (203) 24 (610) LATCHES POWER CORD 1 ALLOW AT LEAST 9 INCHES (229 MILLIMETERS) FROM BACK OF F90 TO WALL FOR REMOVAL OF COVER.
F90A,B SELF-CONT AINED COMMERCIAL ELECTRONIC AIR CLEANER 68-0103-6 Revised 11-07 10 Fig. 9. Mounting the F90 using steel rods in suspended ceiling applications. Mounting the F90A Using the 272577A T ransition Plate (Accessory) The transition plate (Fig.
F90A,B SELF-CONT AINED COMMERCIAL ELECTRONIC AIR CLEANER 68-0103-6 Revised 11-07 11 Permanent Wiring 1. Loosen the two screws and remove the plate covering the wiring compartment. 2. Remove the power cord. • Cut the black and white wires of the power cord, leaving six inches from the electrical connector .
F90A,B SELF-CONT AINED COMMERCIAL ELECTRONIC AIR CLEANER 68-0103-6 Revised 11-07 12 Inst alling Cover 1. Before installing, study the inside of the F90 cover . One end has two latches and the other has two hinge pins. T o properly install the cover , connect the hinge pins to the hinges.
F90A,B SELF-CONT AINED COMMERCIAL ELECTRONIC AIR CLEANER 68-0103-6 Revised 11-07 13 Cleaning the F90 The F90 removes a variety of contaminant s from the air . As it cleans the air , the F90 cells and prefilters become dirty , lowering the cleaning efficiency .
F90A,B SELF-CONT AINED COMMERCIAL ELECTRONIC AIR CLEANER 68-0103-6 Revised 11-07 14 9. Carefully wipe ionizer wires to remove any remaining residue. 10. Check the collection plates of the cell for any detergent residue. If any residue is remaining, repeat the rinse and detergent soaking process until collector plates are clean.
F90A,B SELF-CONT AINED COMMERCIAL ELECTRONIC AIR CLEANER 68-0103-6 Revised 11-07 15 HIGH VELOCITY DETERGENT SPRAY STEAM M677B Fig. 15. Using high velocity water or steam to clean cells. 6. Slide the cells into the channel guides until they touch the backstop of the F90.
F90A,B SELF-CONT AINED COMMERCIAL ELECTRONIC AIR CLEANER 68-0103-6 Revised 11-07 16 If desired, the ozone generated by the F90 can be reduced in one of two ways: • Install the optional activated carbon filters. • Open the cover and move the F90 performance switch to the LO setting.
F90A,B SELF-CONT AINED COMMERCIAL ELECTRONIC AIR CLEANER 68-0103-6 Revised 11-07 17 Fig. 20. F90 electrical troubleshooting procedure. START LED ON/FAN ON NO YES YES YES NO DAMAGED "ON" LED .
F90A,B SELF-CONT AINED COMMERCIAL ELECTRONIC AIR CLEANER 68-0103-6 Revised 11-07 18 M2422A ELECTRONIC AIR CLEANER POWER BOX POWER BOX SECURING SCREWS (5) POWER BOX COVER POWER BOX COVER SECURING SCREWS (5) NOTE: SCREWS ONLY NEED TO BE LOOSENED, NOT REMOVED.
F90A,B SELF-CONT AINED COMMERCIAL ELECTRONIC AIR CLEANER 68-0103-6 Revised 11-07 19 Fig. 22. F90A 120 V ac model schematic diagram. P3 P4 P1 P2 2 1 J2 3 4 1 RED IONIZER BLACK COLLECTOR 1 POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED.
F90A,B SELF-CONT AINED COMMERCIAL ELECTRONIC AIR CLEANER 68-0103-6 Revised 11-07 20 1 1 TERMINAL BOARD FOR POWER SUPPLY CONNECTIONS. POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED. 2 BROWN LEAD MUST BE CONNECTED TO TOP TERMINAL ON TRANSFORMER.
F90A,B SELF-CONT AINED COMMERCIAL ELECTRONIC AIR CLEANER 68-0103-6 Revised 11-07 21 Fig. 25. F90B 120 V ac model schematic diagram. P3 P4 P1 P2 2 1 J2 3 4 1 RED IONIZER BLACK COLLECTOR 1 POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED.
F90A,B SELF-CONT AINED COMMERCIAL ELECTRONIC AIR CLEANER 68-0103-6 Revised 11-07 22 REPLACEMENT PARTS LIST/EXPLODED VIEW See Fig. 26 for exploded view.
F90A,B SELF-CONT AINED COMMERCIAL ELECTRONIC AIR CLEANER 68-0103-6 Revised 11-07 23 Fig. 26. F90A exploded view. Part numbers are keyed to Parts List. M11675 1 5 4 6 18 16 17 15 7 2 11 10 12 14 13 9 8.
F90A,B SELF-CONT AINED COMMERCIAL ELECTRONIC AIR CLEANER 68-0103-6 Revised 11-07 24 Air-Pure Systems 16873 Fish Point Rd. SE Prior Lake, MN 55372-1714 Phone: (800) 998-1919 Fax: (800) 221-3248 www.
Ein wichtiger Punkt beim Kauf des Geräts Honeywell F90B (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Honeywell F90B noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Honeywell F90B - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Honeywell F90B reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Honeywell F90B erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Honeywell F90B besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Honeywell F90B verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Honeywell F90B. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Honeywell F90B gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.