Benutzeranleitung / Produktwartung RC-2000 des Produzenten Home Automation
Zur Seite of 20
1 1 RC-2000 Th ermostat Installation Ins tructions DESCRIPTION The RC-2000 is a precision digital thermostat designed for 24 VAC he ating and cooling systems.
2 2 Location When replacing an ex isting thermostat, install the RC-2000 in the same location. If the existing location doesn' t meet the following criteria, choose a n ew location to mount the RC-2000. When choosing a location for the thermostat: 1.
3 3 Connect each wire to the terminal st rip(s) on the thermostat base per the wiring diagram for your system application - See Figures 4 - 10. Form the thermostat wiring so that the ca ble lies flat between the terminal strip(s) and the center of the base - See Figure 2 .
4 4 TYPICAL WIRING DIAGRAMS CA UTION : Do not short gas valve, fan, heat relay, or cool rela y ...even momentaril y. Do not attempt to hook up to live circuits. An accidental connection to a component on the thermostat circuit board could cause damage to the thermostat.
5 5 3. When configured as a co nventional thermostat, by default this the rmostat does not turn the fan on with a call for heat. If the furnace requi res the thermostat to turn the fan on with a call for heat, confi gure the “System Mode” to “Fan On W ith Heat” under “System Options” .
6 6 Single Stage Conventional 24VAC "HOT" Heat 24VAC Com mon* Fan Cool Humidifier Dehumidier UP 24VAC CONTROL TRANSMFOMER Dehumidifie r Humidifier Fan Relay Cool Rela y Heat Rela y HVAC SYSTEM THERMOSTAT (RC) (C) (Y1) (G) (W1) (D) (H) 1 3 8 6 7 11 12 * Common wire is required in “heat only” or “cool only” applications .
7 7 Single Stage Conventional for Zon e Control Systems (W2) 4 (Y2) (D) (H) (G) (Y1) (W1) (C) (RC) 10 1 3 8 6 7 11 12 ZONE CONTROLLER THERMOSTAT Dehum idifier Humidi fier System Cool Mode Fan Relay Zo.
8 8 Two Stage Conventional (2 Stage Heat / 2 Stage Cool) UP Heat 1 Heat 2 24VAC Common* 24VAC "HOT" Dehumi dier Humidifier Cool 2 Cool 1 Fan 24VAC CONTROL TRANSMFOMER Heat 2 Relay Heat 1 Rel.
9 9 About Heat Pump System s 1) Terminal 5 (O) is energized for coolin g Terminal 6 (B) is energized for heating In most applications, the reversing valve is energiz ed for cooling and should be connected to the "O" terminal.
1 1 0 0 Heat Pum p (2 Stage Heat / 1 Stage Cool) 24VAC Common* 24VAC "HOT" Auxilirary Heat Compressor Ground Fault Humidifier Fan Dehumidier Compre ssor Re lay Aux Heat Relay Fan Relay Humid.
1 1 1 1 Two Speed Heat Pump (3 Stage Heat / 2 Stage Cool) Comp Stage 2 Relay Comp Stag e 1 Rela y Comp ressor Stag e 2 9 5 4 1 3 8 6 7 11 12 (D) (H) (L) (G) (Y1) (B) (O) (W2) (C) (RC) UP HVAC S YSTEM .
1 1 2 2 REMOTE SYSTEM WIRING DIAGRAMS This thermostat has been prepro grammed with energy saving program schedules in accord ance with the ENERGY STAR ® program. W hen used with a remote system, HAI recommends that the Program Mode be configured as “None” or “Occup ancy”.
1 1 3 3 REMOTE SETBACK SWITCH The thermostat can be connected to a remote switch to toggle the desired heat and cool temperature se ttings between preset setpoints.
1 1 4 4 REMOTE TEMPERATURE SENSOR A remote temperature se nsor can be installed to monitor the temperature from a re mote location or can be combined with the onboard temperature sensor for the average temperature of two locations. Run a twisted pair, shielded cable from the RC-20 00 to the remote temperature sensor location.
1 1 5 5 SETUP AND CONFI GURATION NOTE: For proper operation of the features of this thermostat, the Ti me and Date must be set. Even w hen connected to an HAI controller which sets the time and day, the Date must be manually set in the ther mostat under the “S ettings” menu.
1 1 6 6 System Options Note: Before op erating the the rmostat, the “S y stem Type” and “S ystem Mode” must be configured. The thermostat can be configured with the followi ng system options: .
1 1 7 7 Cool/Heat Min On/O ff These items are used to limit the on and off times of the cooling a nd heating system (in minutes). Cool Minimum On The number of minutes the thermostat forces the cooling system to remain on before turning off.
1 1 8 8 This thermostat is equipped with Energy Efficient Control (EEC) tha t continually monitors the performance of the HVAC system and uses Stage 2 (he at or cool) and Stage 3 (auxiliar y heat) onl y when necessary. If it determines that Sta ge 1 is able to heat or cool at a rate of 5 degrees per hour or better, Stage 2 will not be used.
1 1 9 9 Humidity Opt ions The Humidity Options are used to configure the d ehumidifier and/or humidifier output on the thermostat. Not Used: Dehumidifier/Humidifier output is disabled. Fan Speed Control: This option uses the dehumidifier output to control the fan speed on an HVAC system with a variable speed fan.
2 2 0 0 TROUBLESHOOTIN G TIPS SYMP TOM ACTION TO TAKE 1. Check power to the thermostat Thermostat Dead 2. Check wiring diagrams SYMP TOM ACTION TO TAKE 1. Check for break in W or Y wire 2. Allow minimum off time to pass 3. Check sy stem options for correct setting s 4.
Ein wichtiger Punkt beim Kauf des Geräts Home Automation RC-2000 (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Home Automation RC-2000 noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Home Automation RC-2000 - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Home Automation RC-2000 reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Home Automation RC-2000 erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Home Automation RC-2000 besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Home Automation RC-2000 verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Home Automation RC-2000. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Home Automation RC-2000 gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.