WATER TREATMENT SOLUTIONS REVERSE OSMOSIS SYSTEM MODEL RO-150 INSTRUCTION MANUAL 701 S. RIDGE AVENUE - TROY, OHIO 45374-0001 F25054 (January 2004).
-2- TABLE OF CONTENTS G E N E R A L ............................................................................... - 3 - U n p a c k i n g ............................................................................ - 3 - Included in RO-150 Filtration System .
-3- Installation, Operation and Care of RO-150 Reverse Osmosis System SAVE THESE INSTRUCTIONS GENERAL The Hobart RO-150 filter system is designed for foodservi ce equipment where high quality water is essential. The Hobart RO150 meets low water usage demands for steamers, combi-ovens, proofers, deck & rack ovens, and misting systems.
-4- DIMENSIONS OF SYSTEM SHOWN INSTALLATION MOUNTING LOCATION REQUIREMENTS CAUTION: Do not mount to equipment. 1. The filter system must be mounted on a sturdy support structure or wall and must be level.
-5- WATER SUPPLY REQUIREMENTS NOTE: Install the RO-150 in the cold water line only. Installation of the water filter system in a hot water line can damage the filter housing. System performance varies with the incoming water supply temperature. Optimum performance is achieved when water temperature is 70° F.
-6- PUSH TYPE FITTING CONNECTIONS The Hobart RO-150 utilizes quick disconnect push fittings for the majority of connections. Quick disconnect push fittings demand smooth, round, nick-free tubing and straight edges to form leak-free connections.
-7- 2. Determine a location that is easily accessible for storage tank shutoff valve placement. A. Measure the distance from storage tank connection point to desired shutoff valve location.
-8- SAMPLING LINE CONNECTION NOTE: A product water sampling line must be installed on the feed line between the outlet connection tee of the RO filtration system and the connected cooking equipment for water sampling purposes. 1. Determine a location in the feed line to install the Tee and sampling shut-off valve.
-9- OPERATION SYSTEM START UP Start-up conditions. • Water supply is connected to system inlet Tee (inlet ball valve closed). • Storage tank is connected to high pressure switch. • Outlet is connected to equipment (outlet shutoff valve closed). • Sampling line (shut-off valve closed).
-10- MAINTENANCE COMPONENT LOCATION TESTING EFFICIENCY OF RO MEMBRANE NOTE: The RO membrane should be replaced annually or when the removal of Total Dissolved Solids - TDS becomes less than 80% efficient. Contact your local Hobar t Service office for TDS efficiency testing of your Reverse Osmosis system.
-11- RELEASING WATER PRESSURE Prior to replacing any of the RO-150 filters or repairing connections, water pressure must be relieved from the system. 1. Unplug transformer from the electrical outlet. 2. Close the inlet and storage tank shut off valves.
-12- RO-150 FLOW DIAGRAM.
-13- COMPONENT FUNCTION Inlet Connection Tee ............ S p l i t s w a t e r s upply into two paths. One path goes to the beginning of the RO system, the other goes to the bypass ball valve. I n l e t B a l l V a l v e ................. C o n t r o l s i n l e t w a t e r t o t h e R O s y s t e m .
-14- REPLACEMENT PARTS.
-15- INDEX # PART NO . NA ME OF PA RT AM T. 1 01-234506-17400 Elbow 1 NPT x 1 Slip ............................................................................... 1 2 01-234506-16200 Reducer 1 Slip x 1/2 NPT ...........................................
-16- TROUBLESHOOTING SYMPTOM POSSIBLE CAUSE POSSIBLE REMEDY Booster pump doesn't operate. 1. Storage tank ball valve closed. 2. No power at electrical outlet. 3. Transformer malfunction. 4. Booster pump malfunction. 5. High pressure switch malfunction.
Ein wichtiger Punkt beim Kauf des Geräts Hobart RO-150 (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Hobart RO-150 noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Hobart RO-150 - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Hobart RO-150 reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Hobart RO-150 erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Hobart RO-150 besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Hobart RO-150 verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Hobart RO-150. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Hobart RO-150 gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.