DE
Hitachi logo
Offizielle Bedienungsanleitung

Hitachi 309521J

32 Seiten·1.9 MB·Mixer·PDF·EN
Hitachi 309521J
Inhaltsverzeichnis 13 Abschnitte Manual Conventions · Related Manuals · Xtreme Mix OEM Models · Pressure Relief Procedure · … AnzeigenAusblenden
Page 1 of the Hitachi 309521J user manual — Plural Component Mixer, OEM Unit
Seite 1 · Zum Vergrößern klicken
Seite 1

Installation - Parts

Xtreme Mix ™ OEM

Plural Component Mixer, OEM Unit

Hitachi 309521J — Plural Component Mixer, OEM Unit diagram (page 1)
Abb. 1 · Plural Component Mixer, OEM Unit

See page 4 for model information, including maxi- mum working pressure and approvals.

Graco Inc. P.O. Box 1441 Minneapolis, MN 55440-1441 Copyright 2005, Graco Inc. is registered to I.S. EN ISO 9001

Page 3 of the Hitachi 309521J user manual — Related Manuals
Seite 3 · Zum Vergrößern klicken
Seite 3

Manual Conventions

Warning Caution

WARNING

A warning alerts you to possible serious injury or death if you do not follow instructions.

Note

Symbols, such as fire and explosion (shown), alert you to a specific hazard and direct you to read the indi- cated hazard warnings (pages 5-6).

A note indicates additional helpful information.

Related Manuals

Refer to the following manuals for detailed component information.

Component Manuals This manual available in following languages:

ManualDescription 309535Xtreme Mix Operation 309518Xtreme Mix Repair 311762Xtreme Displacement Pump 309347 or 309348King Air Motor King Quiet Air Motor 312145XTR Spray Gun 309524VISCON HP Heater 309525Heated Hose Kit 308981Husky 716 Diaphragm Pump 309615Heater Bracket Kit 309568Remote Manifold Kit
ManualLanguageManualLanguage 309521English309540German 309538French309546Swedish 309539Spanish309604Japanese

Manual Conventions

Page 4 of the Hitachi 309521J user manual — WARNING
Seite 4 · Zum Vergrößern klicken
Seite 4

Xtreme Mix OEM Models

Xtreme Mix OEM Models

WARNING

Do not install equipment approved only for non-haz- ardous location in a hazardous area. Substitution of components may impair intrinsic safety. See page 5.

Approved for Hazardous Location Class I, Div 1, Group D Xtreme Mix Part No.SeriesPump Part No.Pump DescriptionMaximum Working Pressure psi (MPa, bar)Approvals 233871A24927445:1 King4500 (31, 310)ll 2 G Conforms to FM std 3600 & 3610 for use in Class I Div 1 Group D T3 Hazardous locations CAN/CSA 22.2 No. 157-92 & No. 1010.1-92 233872A24927556:1 King5600 (38.6, 386) 233873A24927668:1 King6800 (46.9, 469) 233874A24927780:1 King7250 (50, 500) 233875A24927845:1 Quiet King4500 (31, 310) 233876A24927956:1 Quiet King5600 (38.6, 386) 233877A24928068:1 Quiet King6800 (46.9, 469) 233878A24928180:1 Quiet King7250 (50, 500) 234024Anone Approved for Non-hazardous Location 233879A24927445:1 King4500 (31, 310)Conforms to UL std 61010A-1 CSA std C22.2 No 1010.1-92 233880A24927556:1 King5600 (38.6, 386) 233881A24927668:1 King6800 (46.9, 469) 233882A24927780:1 King7250 (50, 500) 233883A24927845:1 Quiet King4500 (31, 310) 233884A24927956:1 Quiet King5600 (38.6, 386) 233885A24928068:1 Quiet King6800 (46.9, 469) 233886A24928180:1 Quiet King7250 (50, 500) 234025Anone
Page 5 of the Hitachi 309521J user manual — Xtreme Mix OEM Models
Seite 5 · Zum Vergrößern klicken
Seite 5

Xtreme Mix OEM Models

Warning Skin Injection Hazard High-pressure fluid from gun, hose leaks, or ruptured components will pierce skin. This may look like just a cut, but it is a serious injury that can result in amputation. Get immediate surgical treatment. • Do not point the gun at anyone or at any part of the body. • Do not put your hand or fingers over the gun fluid nozzle. • Do not stop or deflect leaks with your hand, body, glove, or rag. • Do not “blow back” fluid; this is not an air spray system. • Follow Pressure Relief Procedure, page 7, when you stop spraying and before cleaning, checking, or servicing equipment. • Use lowest possible pressure when flushing, priming, or troubleshooting. • Never spray without tip guard and trigger guard installed. • Engage trigger lock when not spraying. • Tighten all fluid connections before operating the equipment. • Check hoses, tubes, and couplings daily. Replace worn or damaged parts immediately. High pressure hose cannot be recoupled; replace the entire hose. Fire and Explosion Hazard Solvent and paint fumes in work area can ignite or explode. To help prevent fire and explosion: • Use equipment only in well ventilated area. • Eliminate all ignition sources, such as pilot lights, cigarettes and plastic drop cloths (potential static arc). • Do not plug or unplug power cords or turn lights on or off when flammable fumes are present. • Keep the work area free of debris, including solvent, rags, and gasoline. • Ground equipment and conductive objects. See Grounding, page 11. • Hold gun firmly to side of grounded pail when triggering into pail. • Use only grounded hoses. • If there is static sparking or you feel an electric shock, stop operation immediately. Do not use equipment until you identify and correct the problem. • If connecting PC for data download, PC must be in non-hazardous location and a safety barrier must be installed. See Xtreme Mix software documentation. • Keep a fire extinguisher in the work area. Electric Shock Hazard Improper grounding, wiring, or usage of the system can cause electric shock. • All electrical wiring must be done by a qualified electrician and comply with all local codes and regulations. • Connect only to grounded power source. • Turn off and disconnect power at the main switch before disconnecting any cables and before servicing equipment.
Page 6 of the Hitachi 309521J user manual — Xtreme Mix OEM Models
Seite 6 · Zum Vergrößern klicken
Seite 6

Xtreme Mix OEM Models

Warning Moving parts hazard Moving parts can pinch or amputate fingers and other body parts. Pressurized equipment can start accidentally and cause serious injury. • Keep clear of moving parts. • Do not operate equipment with protective guards or covers removed. • Before checking or servicing equipment, follow Pressure Relief Procedure, page 7. Disconnect power or air supply. • Do not move or lift pressurized equipment. Equipment Misuse Hazard Misuse can cause serious injury or death. • For professional use only. • Use equipment only for its intended purpose. Call your Graco distributor for information. • Read manuals, warnings, tags, and labels before operating equipment. Follow instructions. • Check equipment daily. Repair or replace worn or damaged parts immediately. • Do not alter or modify equipment. Use only Graco parts and accessories. • Do not exceed the maximum working pressure or temperature rating of the lowest rated system component. See Technical Data in all equipment manuals. • Use fluids and solvents that are compatible with equipment wetted parts. See Technical Data in all equipment manuals. Read fluid and solvent manufacturer’s warnings. • Route hoses and cables away from traffic areas, sharp edges, moving parts, and hot surfaces. • Do not kink or overbend hoses or use hoses to pull equipment. • To lift equipment, follow instruction, page 15. • Comply with all applicable approval requirements and safety regulations. Burn Hazard This equipment is used with heated fluid, which can cause equipment surfaces to become very hot. To avoid severe burns: • Do not touch hot fluid or equipment. • Allow equipment to cool completely before touching it. • Wear gloves if fluid temperature exceeds 110° F (43° C). Toxic Fluid or fumes Hazard Toxic fluids or fumes can cause serious injury or death if splashed in the eyes or on skin, inhaled, or swallowed. • Read Material Safety Data Sheet (MSDS) to know the specific hazards of the fluids you are using. • Store hazardous fluid in approved containers, and dispose of it according to applicable guidelines. Personal Protective Equipment You must wear proper protective equipment when operating, servicing, or when in the operating area of the equipment to help protect you from serious injury, including eye injury; inhalation of toxic fumes; and hearing loss. This equipment includes but is not limited to: • Protective eyewear • Gloves, clothing, and respirator as recommended by the fluid and solvent manufacturer • Hearing protection Recoil Hazard The gun can recoil when triggered at a very high pressure. If unprepared, this could force your hand back or cause you to fall and injure yourself. Be sure you have firm footing and hold the gun securely.
Page 7 of the Hitachi 309521J user manual — Pressure Relief Procedure
Seite 7 · Zum Vergrößern klicken
Seite 7

Pressure Relief Procedure

Hitachi 309521J — Pressure Relief Procedure diagram (page 7)
Abb. 2 · Pressure Relief Procedure
6. Hold a metal part of the gun firmly to a grounded metal pail. Trigger gun to relieve pressure.
Hitachi 309521J — Pressure Relief Procedure diagram (page 7)
Abb. 3 · Pressure Relief Procedure

Follow Pressure Relief Procedure when you stop spraying and before cleaning, checking, servicing, or transporting equipment. Read warnings, page 5.

1. Engage trigger lock.
Hitachi 309521J — Pressure Relief Procedure diagram (page 7)
Abb. 4 · Pressure Relief Procedure
7. Engage trigger lock.
Hitachi 309521J — Pressure Relief Procedure diagram (page 7)
Abb. 5 · Pressure Relief Procedure
8. Place waste container under sampling valves, then open valves A and B slowly to relieve pressure between pump and metering valves.
Hitachi 309521J — Pressure Relief Procedure diagram (page 7)
Abb. 6 · Pressure Relief Procedure
3. Close main air shutoff valve on air supply line and on unit. Turn off air regulator.
4. Close fluid sampling and shutoff valves A and B.
Hitachi 309521J — Pressure Relief Procedure diagram (page 7)
Abb. 7 · Pressure Relief Procedure
9. Close sampling valves A and B.
Hitachi 309521J — Pressure Relief Procedure diagram (page 7)
Abb. 8 · Pressure Relief Procedure
5. Disengage trigger lock.
Hitachi 309521J — Pressure Relief Procedure diagram (page 7)
Abb. 9 · Pressure Relief Procedure

Pressure Relief Procedure

Page 8 of the Hitachi 309521J user manual — F IG . 1
Seite 8 · Zum Vergrößern klicken
Seite 8

Assemble

Hitachi 309521J — Assemble diagram (page 8)
Abb. 10 · Assemble

F IG . 1

Assemble

Page 9 of the Hitachi 309521J user manual — Pumps and Sensors
Seite 9 · Zum Vergrößern klicken
Seite 9

Pumps and Sensors

Control Box

1. Mount control box (3) to mounting plate (10). F IG . 1.
  • If using feed pumps, do not allow feed pressure to exceed 25% of spray pressure.

a. Slide gasket (307) over back of pneumatic con- trol box (3), against lip. Insert box through mounting plate (10).

  • For accurate ratios, pump lowers must be same size.
  • If installing 234024 or 234025, the pump size has not been set in the software. To set pump A and B size and A and B sensor calibration factors, you need Xtreme Mix Data Download software, part no. 246322 for proportioners located in a non-hazardous area, or part no. 246397 for proportioners located in a hazardous area.

b. Secure box (3) to plate (10) with 8-32 UNC screws (912).

Mount box (3) vertically for optimum alternator and component life.

2. Secure mounting plate (10) to cart/stand. Install fasteners (provided by installer) through six 0.3” (7.62 mm) mounting plate holes.

Calibration values are on pump A and B sen- sors.

3. Connect conduit (721) from two sensors (7) to pneumatic control box (3).
Hitachi 309521J — Pumps and Sensors diagram (page 9)
Abb. 11 · Pumps and Sensors
PumpSize Value (cc/cycle) 45:1250 56:1220 68:1180 80:1145

Conduit must be used. Approximately 62” (1575 mm) of cable and conduit provided; do not lengthen.

4. Wire two sensors (7) to control box 18-pin connector. Connect sensor A, then sensor B wires in pairs sequentially – black/green, black/red, black/white – to pins 2-13. See Electrical Schematic , page 16.
1. Secure magnet holders (903) to the pump (2) motor displacement rods with screws (905). F IG . 1.
5. Connect 18-pin connector to main control board connector (F). F IG . 2.
2. Install a short magnet strip then a long one (904) on each magnet holder (903). Secure with tape supplied.
Hitachi 309521J — Pumps and Sensors diagram (page 9)
Abb. 12 · Pumps and Sensors
3. Secure pumps (2) on mounting brackets with two 3/8 x 1-1/4” screws (913), lockwashers (914), and nuts (915).
4. Secure sensors (7) on pumps and pump mounting brackets with two screws (913), lockwashers (914), and nuts (915).

FIG. 2 Control Box

Assemble · Pump Size Values

Page 10 of the Hitachi 309521J user manual — F IG . 3
Seite 10 · Zum Vergrößern klicken
Seite 10
Hitachi 309521J — Assemble diagram (page 10)
Abb. 13 · Assemble

Key: A Pump A Air B Pump B Air C Pump A Pilot Air D Pump B Pilot Air E Air Supply F Metering Valve A - CLOSE G Metering Valve A - OPEN H Metering Valve B- CLOSE J Metering Valve B- OPEN K Sensor A Cable L Sensor B Cable 2 Pump

3 Pneumatic Control 6 Metering Valve Manifold 501 Pneumatic Valve 901 Air Filter 902 Ground Wire Assembly

Ground manifold to true earth ground.

Ground by connecting ground wire from control box (3) to manifold (6).

Ground by connecting ground wire from pumps (2) to manifold (6).

F IG . 3

Assemble

Page 11 of the Hitachi 309521J user manual — Air Controls
Seite 11 · Zum Vergrößern klicken
Seite 11

Grounding

Standard Setup

FIG. 1 and FIG. 3

Hitachi 309521J — Standard Setup diagram (page 11)
Abb. 14 · Standard Setup
1. Mount pneumatic control assembly (3) to mounting plate (10). F IG . 1.
2. Connect an air line (A and B) between each pneumatic valve (501) and pump air motor inlet. F IG . 3.
1. Connect 12 gauge ground wire (provided by installer) from pneumatic control box (3) ground screw (312, page 22) to metering valve manifold (6). Refer to F IG . 3.

36” (914 mm) hoses provided. Installer may pro- vide different lengths.

2. Connect ground wire from each pump (2) to metering valve manifold (6).
3. Connect air supply from air manifold’s 5 micron air filter (518) to control box air inlet (not shown).
3. Connect ground wire assembly (902) to fluid manifold (6). Connect clamp end to a true earth ground before starting unit.

The alternator requires 12-15 scfm of air to func- tion correctly.

  • Do not use 3/8” (9.5 mm) ID air supply tubing longer than 24” (610 mm) from air filter to control box air inlet.

Air Controls

Do not use air supply hose smaller than 3/4” (19 mm) ID. Smaller hose could restrict air flow and cause alternator, solenoids, or Mac valves to mal- function. Check air supply gauge at pump changeover; air pressure should not drop.

  • Do not restrict control box exhaust air.

Increased back pressure can cause a drop in alternator power output, resulting in delayed valve action and processor shutdown and reboot.

4. Connect tubing (C and D) from solenoids to each pneumatic valve (501).
5. Mount air supply filter (901) to cart/stand and connect air supply (E) to air manifold (5) air inlet.

Assemble

Page 12 of the Hitachi 309521J user manual — Install Sampling Valves 244683
Seite 12 · Zum Vergrößern klicken
Seite 12

User Interface

Hitachi 309521J — User Interface diagram (page 12)
Abb. 15 · User Interface

FIG. 4 and FIG. 5

1. Connect display board (410) communication cable (416) to J1 on main circuit board (301).
2. Connect data cable (406 - 7-pin connector) to J2.
Hitachi 309521J — User Interface diagram (page 12)
Abb. 16 · User Interface

The user interface must be grounded. Read warnings, page 5.

FIG. 5 Control Box

3. Connect ground wire (315) to ground stud on back of cover with nut (311).

Fluid Manifold

4. Secure cover (4) to mounting plate (10) with lockwashers (911) and nuts (910). F IG . 1.
Hitachi 309521J — Fluid Manifold diagram (page 12)
Abb. 17 · Fluid Manifold
Hitachi 309521J — Fluid Manifold diagram (page 12)
Abb. 18 · Fluid Manifold

Install Sampling Valves 244683

Install sampling valves (918) into the metering valves (601). Install barb fitting (919) and tubing (920) into each sampling valve. FIG. 7.

F IG . 4Cover - back view

Assemble

Page 13 of the Hitachi 309521J user manual — F IG . 8
Seite 13 · Zum Vergrößern klicken
Seite 13

Cart-mounted

Hitachi 309521J — Cart-mounted diagram (page 13)
Abb. 19 · Cart-mounted
1. Secure metering valve assembly (6) to cart/stand with screws (913), washer (914), and nuts (915). F IG . 1, page 8.
2. Connect fluid lines (provided by installer) between pumps and metering valves.
3. Cut air line tubing (included) to length needed to connect between metering valves (601) and solenoid outlets. F IG . 3, page 10, and F IG . 6.
Hitachi 309521J — Cart-mounted diagram (page 13)
Abb. 20 · Cart-mounted

F IG . 7

Pilot Valve A side

E

Pilot Valve B side

Hitachi 309521J — E diagram (page 13)
Abb. 21
F IG . 6Control Box - bottom

Remote Fluid Manifold

To install remote fluid manifold, order part no. 15A898. All other parts referred to in the following procedure are parts you remove from the stan- dard manifold and reuse or parts the installer must supply.

1. Remove metering valves (601) and shutoff valves (606, 611) from fluid manifold (607). F IG . 7.

F IG . 8

2. Install metering valves (601) and shutoff valves (606, 611) onto fluid metering manifold 15A898. F IG . 8.
Hitachi 309521J — F IG . 8 diagram (page 13)
Abb. 22
  • Maximum length of tubing is 36” (914 mm). Locate fluid manifold as close as possible.
3. Secure fluid metering manifold 15A898 on the cart/stand with 2 screws (913), washers (914) and nuts (915).

Assemble · 919, 920 · A side 606

Page 14 of the Hitachi 309521J user manual — Balancing Back Pressure
Seite 14 · Zum Vergrößern klicken
Seite 14
4. Screw ball valves (606, 611 - purchased separately) into fluid mix manifold (607).

To calculate pressure loss:

Pressure Loss = 0.000273 x Q x V L

5. Select appropriate fittings and fluid hose sizes and lengths to connect between fluid metering manifold 15A898 and mix manifold (607).

D 4

Q = Flow (GPM) V = Viscosity in centipoise L = Length of pipe in feet D4 = Pipe diameter to the 4th power

Balance pressure drops in the 2 lines as instructed below to assure an accurate mix ratio.

Example: If you need to pump 1 gpm of high solids paint (40 seconds in a Zahn #2 cup = 100 cp) 100 ft. in a sys- tem using 1/4” pipe:

6. Connect fluid lines (provided by installer) between pumps and metering valves (601).
7. Connect mixed material hose to fluid mix manifold (607) outlet (E).

Pressure Loss = 0.000273 x 1 gpm x 100 cp x 100 ft.

(.364 ID) .018 D4 factor

8. Cut air line tubing (included) to length needed to connect between metering valves (601) and solenoid outlets. F IG . 3, page 10, and F IG . 6, page 13.

Pressure Loss = 152 psi

Reduce pressure loss by using:

9. Cut air line tubing, included, (F, G, H, J - F IG . 3, page 10) to length needed to connect between metering valves (601) and solenoid outlets.
  • Large diameter pipe or tubing
  • Constant tubing or pipe size
  • Long runs without bends
  • Long radius elbows
10. Connect ground wires.

You can balance differences in component back pres- sure by adjusting hose diameter and length.

Balancing Back Pressure

This procedure is for the remote fluid manifold only.

D4 = .018 for 1/4” pipe .06 for 3/8” pipe .15 for 1/2” pipe

Flow rates and/or viscosity differences between compo- nent materials can create different pressure drops from the proportioner to the manifold, causing unequal back pressure. This will effect mix ratio accuracy.

Using the previous example (.000273 x 1 x 100 x 100 = 2.73):

Pressure drop: 1/4” pipe = 152 psi 3/8” pipe = 46 psi 1/2” pipe = 18 psi

Assemble

Page 15 of the Hitachi 309521J user manual — F IG . 9
Seite 15 · Zum Vergrößern klicken
Seite 15

Proper Lifting

WARNING

Follow instructions below to avoid dropping or swing- ing unit or being struck by the cart handle, which can cause serious injury or damage to equipment.

Either remove the cart handle or secure it to the cart before lifting the unit. Connect a bridle swing, hooking an end to each of the Xtreme Mix air motor rings. Hook the center ring on a hoist. See FIG. 9. Carefully lift the Xtreme Mix unit; make sure it balances evenly.

F IG . 9

Operation and Repair

For operating instructions, including data collection, see Xtreme Mix Operation manual.

For troubleshooting, alarm information, and repair instructions, see Xtreme Mix Repair manual.

Proper Lifting

Page 16 of the Hitachi 309521J user manual — Electrical Schematic
Seite 16 · Zum Vergrößern klicken
Seite 16

Electrical Schematic

Hitachi 309521J — Electrical Schematic diagram (page 16)
Abb. 23 · Electrical Schematic
KeyBL Black BR Brown BL-G Black with green BL-R Black with red

BL-WBlack with white G Green GNDGround R Red

S Shield W White

Electrical Schematic

Page 17 of the Hitachi 309521J user manual — Electrical Schematic
Seite 17 · Zum Vergrößern klicken
Seite 17
Hitachi 309521J — Electrical Schematic diagram (page 17)
Abb. 24 · Electrical Schematic

Electrical Schematic · 301 304

Page 18 of the Hitachi 309521J user manual — F IG . 10
Seite 18 · Zum Vergrößern klicken
Seite 18

Pneumatic Schematic

Turbine / Power Supply

To Pump A Pilot

To Pump B Pilot

1/2” x 24” long

26 psi (79 kPa, 1.8 bar) Relief Valve

12 VDC

12 VDC

12 VDC

Gauge 90/110 psi 0.6/0.8 MPa, 6.2/8 bar)

8 bar) Relief Valve

Air Regulator 110 psi (0.8 MPa,

King Motor A King Motor B

3/4” Ball Valve bleed type

Gauge 3/8” Air Reg. Auto Drain

5 micron 100 psi (0.7 MPa, 7 bar)

3/4” Air Filter Auto Drain

F IG . 10

Show 34 more labels / short text on this page
Pneumatic Schematic · A Metering · B Metering · Valve · Valve · Manifold · A Open · 5/32” · B Open · 3-way valve · 306t 304 · A Close · 5/32” · B Close · 3-way valve · Position 2 · Position 3 · 12 VDC Solenoid · Position 1 · Position 4 · Exhaust · Solenoid · Solenoid · Solenoid · Air Supply Air · To Manifold · 3/8” tube · 306e · Alternator Air · Pump A Pilot · Pump B Pilot · Regulator · Relief Valve · 20 micron
Page 19 of the Hitachi 309521J user manual — Pneumatic Schematic
Seite 19 · Zum Vergrößern klicken
Seite 19

Pneumatic Schematic

Page 20 of the Hitachi 309521J user manual — Xtreme Mix Proportioner
Seite 20 · Zum Vergrößern klicken
Seite 20

Xtreme Mix Proportioner

Hitachi 309521J — Xtreme Mix Proportioner diagram (page 20)
Abb. 25 · Xtreme Mix Proportioner
Page 21 of the Hitachi 309521J user manual — Part Numbers
Seite 21 · Zum Vergrößern klicken
Seite 21

Xtreme Mix Proportioner

Part Numbers

Approved for Hazardous Location

Approved for Non-hazardous Location

(Class 1, Div 1, Group D)

Xtreme Mix Pump (2) Plate (10)

Xtreme Mix Pump (2) Plate (10)

233879 249274 (45:1) 246333 233880 249275 (56:1) 246335 233881 249276 (68:1) 246337 233882 249277 (80:1) 246339 233883 249278 (45:1) 246333 233884 249279 (56:1) 246335 233885 249280 (68:1) 246337 233886 249281 (80:1) 246339 234025 none 246339

233871 249274 (45:1) 246332 233872 249275 (56:1) 246334 233873 249276 (68:1) 246336 233874 249277 (80:1) 246338 233875 249278 (45:1) 246332 233876 249279 (56:1) 246334 233877 249280 (68:1) 246336 233878 249281 (80:1) 246338 234024 none 246338

Refer to page 4 for additional model information.

Includes:

Kit 246149, Item 9

Ref. No. Part No. Description Qty.

Ref. No. Part No. Description Qty. 901 117628 AIR FILTER; 3/4 npt 1 902 244524 GROUND WIRE, with clamp 1 903 15A847 MAGNET HOLDER 2 904 15A814 MAGNET STRIP 2 905 104092 SCREW; 10-24 UNC 4 906 511352 STATIC MIXER, not shown 1 907 054753 TUBING, nylon, black; 0.156” (4 mm), 10 ft. (3 m), not shown 908 113498 SAFETY RELIEF VALVE; 110 psi (0.8 MPa, 8 bar)

2 PUMP; see table above; see pump manual for parts

3 245803 PNEUMATIC CONTROL; page 22 1 4 245804 USER INTERFACE; page 24 1 5 245802 PUMP AIR MANIFOLD 1 6 245824 METERING VALVE MANIFOLD; page 26

7 245825 SENSOR; page 29 2 9 246149 KIT; includes 901-917 1 10 PLATE; see table above 1 918 245143 SAMPLING VALVE; parts page 26 2 919 116746 FITTING; 1/8 npt x 1/4” (6.4 mm) tube; see page 26

909 116643 SAFETY RELIEF VALVE; 90 psi (621 kPa, 6.2 bar)

910 100015 NUT; 1/4-20 UNC 4 911 100016 LOCKWASHER 4 912 103196 SCREW; 8/32 UNC 6 913 100004 SCREW; 3/8 UNC 8 914 100133 LOCKWASHER 8 915 100131 NUT; 3/8-16 UNC 8 916 054139 TUBING, nylon; 0.5” (13 mm); 3 ft. (0.9 m), not shown

920 116750 TUBE, nylon; 5 in. (12.7 cm); see page 26

917 C12508 TUBING, nylon; 0.375” (9.5 mm); 3

ft. (0.9 m), not shown

★ Order length needed from distributor.

★ · ★

Page 22 of the Hitachi 309521J user manual — A PUMP
Seite 22 · Zum Vergrößern klicken
Seite 22

Pneumatic Control 245803

Item 3, page 21

Hitachi 309521J — Pneumatic Control 245803 diagram (page 22)
Abb. 26 · Pneumatic Control 245803

A PUMP

Page 23 of the Hitachi 309521J user manual — Pneumatic Control 245803
Seite 23 · Zum Vergrößern klicken
Seite 23

Pneumatic Control 245803

Ref. No. Part No. Description Qty.

Ref. No. Part No. Description Qty.

  • 306n‡
  • PLUG, pipe; 1/8-27 ptf 5 306p 114128
  • ELBOW; 1/4 npt x 1/2” (13 mm) tube

301 245705 CIRCUIT BOARD 1 301a 15C318 FUSE, circuit board 1 302‡ SCREW; 8-32 UNC 4 303‡ COVER 1 304** 245854 ALTERNATOR MODULE; includes items 304a-304e

306q† 112512 • WIRE FERRULE, orange, not shown

  • 306r 117369
  • CONNECTOR, 12 position 1 306s 150278
  • ADAPTER, 1/4 x 1/8 npt 1 306t 117480
  • SAFETY RELIEF VALVE, 26 psi (179 kPa, 1.8 bar)
  • 304a 193154
  • GASKET 1 304b 15A853
  • WIRE HARNESS 1 304c 111225
  • TUBE FITTING; 90° 2 304d 114380
  • SCREW; M5 x 25 4 304e 249254
  • TURBINE ALTERNATOR 1 305‡ LOCKNUT; 8-32 UNC 2 306‡ SOLENOID MODULE, IS; includes items 306a-306t

307 15A800 GASKET, neoprene 1 309‡ SCREW; M5 x 10 2 310 590385 TUBE, poly-flo; 3/8” OD; 1 ft. (3 m) ★ 311‡ NUT, KEPS; #10-24 1 312 104029 GROUNDING STUD 1 313 15A849 WIRE HARNESS, alarm 1 314 117442 CONNECTOR, 18 position 1 315 15B090 GROUNDING WIRE, door 1 316 15B056 LABEL, air connections 1 317 111307 LOCKWASHER 1 320 118132 LOCKWASHER, terminal 1 321 118129 SPACER, 8-32 UNC x 5” (127 mm) 1

  • 306a 15A822
  • MANIFOLD 1 306b 117356
  • VALVE, 12 VDC, IS 4 306c 114263
  • FITTING; 1/8 npt x 5/32” (4 mm) tube
  • 306d‡
  • NIPPLE; 1/4 npt 1 306e 115243
  • AIR REGULATOR; 1/4 npt 1 306f 115841
  • ELBOW, swivel; 1/4 npt x 3/8” (9.5 mm) tube

IS = intrinsically safe

  • 306g 160701
  • ELBOW, street; 1/8 npt(m x f) 1 306h 108190
  • GAUGE, 1 306j‡
  • GASKET, neoprene 1 306k‡
  • GASKET, neoprene 1

** Alternator bearing repair kit 223688 available.

‡ Not available for order from Graco.

★ Order length needed from distributor.

Page 24 of the Hitachi 309521J user manual — User Interface 245804
Seite 24 · Zum Vergrößern klicken
Seite 24

User Interface 245804

Item 4, page 21

Hitachi 309521J — User Interface 245804 diagram (page 24)
Abb. 27 · User Interface 245804

Ref. No. Part No. Description Qty.

Ref. No. Part No. Description Qty.

414‡ MOUNT 3 415‡ STRAP 3 416 15A854 WIRE HARNESS, display 1 418‡ WASHER 4 419 107232 SET SCREW 1

401‡ COVER 1 403 15A851 WIRE HARNESS, start/stop 1 404 15A801 GASKET 1 405 15C335 KNOB 1 406 15A850 WIRE HARNESS, data port 1 407 15A852 WIRE HARNESS, key switch 1 409* LABEL, alarm code 1 410 245706 CIRCUIT BOARD 1 411‡ SCREW; 4-40 2 412 15A856 DISPLAY PANEL 1 413‡ NUT; 4-40 4

‡ Not available for order from Graco. * Alarm Code Labels Item 409, English provided. To order other languages:

Part No. Languages

15B843 Chinese, Finnish, Portuguese, Greek, Swedish, Italian 15B844 English, Spanish, French, German, Korean, Japanese

Page 25 of the Hitachi 309521J user manual — TI2295B
Seite 25 · Zum Vergrößern klicken
Seite 25

Pump Air Manifold 245802

Item 5, page 21

Hitachi 309521J — Pump Air Manifold 245802 diagram (page 25)
Abb. 28 · Pump Air Manifold 245802

Ref. No. Part No. Description Qty.

501 C59752 VALVE, 3-way 2 502 108307 ELBOW; 3/4 npt 2 503 101689 PRESSURE GAUGE 2 504 112166 SCREW; 1/4-20 UNC 4 505 15A820 MANIFOLD 1 506 15A821 PLATE, direction 1 507 117332 REGULATOR 1 508 100840 ELBOW; 1/4 npt 1 510 15A819 MANIFOLD BLOCK 1 511 160032 NIPPLE; 3/4 npt 1 512 117346 SHUTOFF VALVE, vented 1 513 117364 O-RING, nitrile 3 514 108849 SCREW; 1/4-20 UNC 2 515 15B554 HOSE; 3/4 npt; 4 ft. (1.2 m) 2 516 100549 ELBOW, 90°; 3/4 npt 2 517 165198 NIPPLE; 1/4 x 3/8 npt 1 518 119644 FILTER; 3/8 npt; 5 micron 1 519 114316 ELBOW, swivel; 3/8 npt 1 520 114151 ELBOW, swivel; 1/8 npt x 5/32” (4 mm) tube

521 100721 PLUG; 1/4-18 nptf 3 522 512912 MUFFLER; 1/2 npt 2 523 100896 BUSHING; 3/4 x 1/2 npt 2 524 113498 SAFETY RELIEF VALVE; 110 psi (0.8 MPa, 8 bar)

525 117443 STANDOFF, aluminum, 8-32 UNC 2 526 240900 HOSE; 3/4 npt; 2.5 ft. (0.76 m) 1 527 158962 ELBOW, 1/8 (m) x 1/4 (f) 1 528 113911 GUAGE, 1/8, air 1

TI2295B

100 psi (0.7 MPa, 7 bar) setting. 1

Page 26 of the Hitachi 309521J user manual — Sampling Valve 245143
Seite 26 · Zum Vergrößern klicken
Seite 26

Metering Valve Manifold 245824

Item 6, page 21

Ref. No. Part No. Description Qty.

918h 918g 918d 918f 918b 918e 918a

601 245846 METERING VALVE; page 27 2 606 245861 SHUTOFF VALVE; see manual 306861 1

606 (A side) 611 (B side)

607 245833 FLUID MANIFOLD; page 28 1 611 245860 SHUTOFF VALVE; see manual 306861 1

Sampling Valve 245143

Ref. No. Part No. Description Qty.

* See page 21 for part no. and description.

918a 245110 KNOB 1 918b 197681 HOUSING 1 918c 197332 SEAT 1 918d 107536 BALL, carbide 1 918e 110082 RETAINING RING 1 918f 111457 O-RING, PTFE 2 918h 187060 GASKET 1

*919 · *920 · Item 918

Page 27 of the Hitachi 309521J user manual — Metering Valve 245846
Seite 27 · Zum Vergrößern klicken
Seite 27

Metering Valve 245846

Hitachi 309521J — Metering Valve 245846 diagram (page 27)
Abb. 29 · Metering Valve 245846

Ref. No. Part No. Description Qty.

Ref. No. Part No. Description Qty.

635† 109141 SPRING 1 636 102040 LOCKNUT; 1/4 UNC 2 637*† V-PACKING, UHMWPE 6 638*† 189901 GLAND, male 1 639*† V-PACKING, leather 5 643*† O-RING, buna-n 1 644† 15A830 SEAT 1 645*† 107079 O-RING, PTFE 2 646 15A832 SEAT HOUSING 1 647 102637 SCREW; 3/8 UNC-2A 4

621 598140 ELBOW, 1/8 npt(m) x 5/32” (4 mm) tube

622‡ VALVE CAP 1 623‡ PISTON 1 624‡ CYLINDER 1 625 15B545 PISTON ROD 1 626 15A834 TIE ROD 2 627 15A835 PACKING NUT 1 628 15A833 INLET HOUSING 1 629▲180233 WARNING LABEL 1 630† 245850 FLUID NEEDLE 1 631 111040 LOCKNUT, nylon; 5/16 UNC-3B 1 632*† O-RING, nitrile 1 633*† O-RING, nitrile 1 634*† O-RING, nitrile 1

* Parts included in kit 234098. † Parts included in kit 234131.

‡ Not available for order from Graco. ▲ Replacement Warning labels available at no cost.

Show 5 more labels / short text on this page
*† 634 · *† 632 · *† 633 · † 635 · *† 643
Page 28 of the Hitachi 309521J user manual — Fluid Manifold 245833
Seite 28 · Zum Vergrößern klicken
Seite 28

Fluid Manifold 245833

Item 607, page 26

*663 *665 *664 *665 *666 *667

Ref. No. Part No. Description Qty.

Ref. No. Part No. Description Qty.

669 15A825 PIPE, outlet 1 670 192977 PIPE, center 1 671‡ HOUSING 1 674 111307 LOCKWASHER 2 675 116343 GROUND SCREW,; M5 x 0.8 2 676 159239 NIPPLE; 3/8 x 1/2 npt 1

661 15A823 PLUG 2 662* 107098 O-RING, PTFE 2 663* 107313 O-RING, PTFE 2 664* SEAT 2 665* 103341 O-RING, PTFE 5 666* BALL, metallic 2 667* 117333 SPRING 2 668 PLUG; 3/8 npt 4

* Parts included in kit 234100.

‡ Not available for order from Graco.

Show 4 more labels / short text on this page
669 676 · 675 674 665 · 670 668 · *662
Page 29 of the Hitachi 309521J user manual — Sensor 245825
Seite 29 · Zum Vergrößern klicken
Seite 29

Sensor 245825

Item 7, page 21

Hitachi 309521J — Sensor 245825 diagram (page 29)
Abb. 30 · Sensor 245825

Ref. No. Part No. Description Qty.

Ref. No. Part No. Description Qty.

712† 15A817 NUT; 1/8 npt 1 713* 117569 FITTING; 3/8 npt x 5/16” conduit 2 714† 154741 O-RING, buna-n 1 715 245831 BRACKET 1 716† 104765 PLUG; 18-27 ptf 1 719* 117586 LOCKNUT; 3/8-18 npt 2 720† C20272 O-RING; fluoroelastomer 1 721* 117582 CONDUIT, 5 ft. (1.5 m) ★

701† 196280 CAP 1 702* 15A818 COVER 1 703† 243500 BOARD 1 704† 115925 SPACER 2 705* 117331 CABLE 1 706† 115917 SENSOR 1 707† 110004 O-RING, PTFE 1 708† 196289 CAP 1 709* 116024 TAB TERMINAL 1 710* 101855 SCREW; 4-24 UNC 1 711* 112546 SCREW; 4-40 taptite 2

* Parts included in kit 246345. † Parts included in kit 246344. ★ Order length needed from distributor.

Calibration label. 1

Show 10 more labels / short text on this page
704† · 703† · 720† · 710* · 709* · 702* · 705* · 719* · 713* · 721*
Page 30 of the Hitachi 309521J user manual — Technical Data
Seite 30 · Zum Vergrößern klicken
Seite 30

Technical Data

Mix ratio range 0.0:1-10:1 (in 0.1 increments) Ratio tolerance range +/- 5% Flow rates

Minimum 1 qt./min. (0.95 liter/min.)* Maximum 3 gal./min. (11.4 liter/min.) Fluid viscosity range 200-20,000 cps (heavier viscosities can be mixed with use

of optional heaters, heated hoses, and hardware) Fluid filtration 60 mesh, (238 micron) standard Maximum fluid working pressure

45:1 4500 psi (31 MPa, 310 bar) 56:1 5600 psi (38.6 MPa, 386 bar) 68:1 6800 psi (46.9 MPa, 469 bar) 80:1 7250 psi (50 MPa, 500 bar) Air supply pressure range 50-110 psi (345-800 kPa, 3.5-8 bar)

Maximum air consumption at 100 psi (0.7 MPa, 7 bar) in cfm (m3/min.)

45:1 110 (3.1) 56:1 125 (3.5) 68:1 155 (4.4) 80:1 180 (5.1) Ambient temperature range

Operating 32-130° F (0-54° C) Storage 30-160° F (–1-71° C) Environmental Conditions Rating Indoor/outdoor use

Altitude up to 4000 meters Maximum relative humidity to 99% up to 54° C Pollution degree (11) Installation category (2) Sound pressure 98 dBA at 100 psi (0.7 MPa, 7 bar) Wetted parts

Suction tubes aluminum Pumps carbon steel, alloy steel, 303, 440 & 17-4ph grades stain-

less steel, zinc and nickel plating, ductile iron, tungsten carbide, PTFE, leather Metering Valves carbon steel, zinc plating, carbide, polyethylene, leather Manifold carbon steel, zinc plating, carbide, 302 stainless steel Mixer stainless steel Spray gun See gun manual PC Communications RS-232

* Minimum flow rate is dependent on the material being sprayed and mixing capability. Test your material for spe- cific flow rate.

Technical Data

Page 31 of the Hitachi 309521J user manual — Technical Data
Seite 31 · Zum Vergrößern klicken
Seite 31

Technical Data

Page 32 of the Hitachi 309521J user manual — GRACO INC. P.O. BOX 1441 MINNEAPOLIS, MN 55440-1441
Seite 32 · Zum Vergrößern klicken
Seite 32

Graco Standard Warranty

Graco warrants all equipment referenced in this document which is manufactured by Graco and bearing its name to be free from defects in material and workmanship on the date of sale to the original purchaser for use. With the exception of any special, extended, or limited warranty published by Graco, Graco will, for a period of twelve months from the date of sale, repair or replace any part of the equipment determined by Graco to be defective. This warranty applies only when the equipment is installed, operated and maintained in accordance with Graco’s written recommendations.

This warranty does not cover, and Graco shall not be liable for general wear and tear, or any malfunction, damage or wear caused by faulty installation, misapplication, abrasion, corrosion, inadequate or improper maintenance, negligence, accident, tampering, or substitution of non-Graco component parts. Nor shall Graco be liable for malfunction, damage or wear caused by the incompatibility of Graco equipment with structures, accessories, equipment or materials not supplied by Graco, or the improper design, manufacture, installation, operation or maintenance of structures, accessories, equipment or materials not supplied by Graco.

This warranty is conditioned upon the prepaid return of the equipment claimed to be defective to an authorized Graco distributor for verification of the claimed defect. If the claimed defect is verified, Graco will repair or replace free of charge any defective parts. The equipment will be returned to the original purchaser transportation prepaid. If inspection of the equipment does not disclose any defect in material or workmanship, repairs will be made at a reasonable charge, which charges may include the costs of parts, labor, and transportation.

THIS WARRANTY IS EXCLUSIVE, AND IS IN LIEU OF ANY OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO WARRANTY OF MERCHANTABILITY OR WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE.

Graco’s sole obligation and buyer’s sole remedy for any breach of warranty shall be as set forth above. The buyer agrees that no other remedy (including, but not limited to, incidental or consequential damages for lost profits, lost sales, injury to person or property, or any other incidental or consequential loss) shall be available. Any action for breach of warranty must be brought within two (2) years of the date of sale.

GRACO MAKES NO WARRANTY, AND DISCLAIMS ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, IN CONNECTION WITH ACCESSORIES, EQUIPMENT, MATERIALS OR COMPONENTS SOLD BUT NOT MANUFACTURED BY GRACO. These items sold, but not manufactured by Graco (such as electric motors, switches, hose, etc.), are subject to the warranty, if any, of their manufacturer. Graco will provide purchaser with reasonable assistance in making any claim for breach of these warranties.

In no event will Graco be liable for indirect, incidental, special or consequential damages resulting from Graco supplying equipment hereunder, or the furnishing, performance, or use of any products or other goods sold hereto, whether due to a breach of contract, breach of warranty, the negligence of Graco, or otherwise.

FOR GRACO CANADA CUSTOMERS The Parties acknowledge that they have required that the present document, as well as all documents, notices and legal proceedings entered into, given or instituted pursuant hereto or relating directly or indirectly hereto, be drawn up in English. Les parties reconnaissent avoir convenu que la rédaction du présente document sera en Anglais, ainsi que tous documents, avis et procédures judiciaires exécutés, donnés ou intentés, à la suite de ou en rapport, directement ou indirectement, avec les procédures concernées.

Graco Information

TO PLACE AN ORDER, contact your Graco distributor or call to identify the nearest distributor. Phone: 612-623-6921 or Toll Free: 1-800-328-0211, Fax: 612-378-3505

All written and visual data contained in this document reflects the latest product information available at the time of publication.

Graco reserves the right to make changes at any time without notice.

This manual contains English. MM 309521 Graco Headquarters: Minneapolis International Offices: Belgium, China, Japan, Korea

GRACO INC. P.O. BOX 1441 MINNEAPOLIS, MN 55440-1441

www.graco.com

Quellen

Referenzen & Links

In dieser Anleitung genannte Seiten – Hersteller, Support und Downloads.

Frage zu Hitachi 309521J stellen

Besitzer und unser Team antworten in der Regel innerhalb eines Tages – und Ihre Frage hilft auch anderen weiter.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Noch keine Fragen zu Hitachi 309521J

Stellen Sie die erste Frage — andere Nutzer oder unser Team antworten Ihnen.

Originaldokument

Hitachi 309521J PDF-Anleitung

32 Seiten·1.9 MB·Mixer·PDF
Klicken Sie oben auf eine Seite, um sie hier zu öffnen
Seite 1 / …
100%
Seiten werden geladen…