Benutzeranleitung / Produktwartung RocketRAID 4322 des Produzenten Highpoint
Zur Seite of 52
RocketRAID 432x SAS/SA T AII Host Adapter User ’ s Guide Revision: 1.0 Date: November 2008 HighPoint T echnologies, Inc. 1.
Copyright Copyright © 2008 HighPoint T echnologies, Inc. This document contains materials protected by International Copyright Laws. All rights reserved. No part of this manual may be reproduced, transmitted or transcribed in any form and for any purpose without the express written permission of HighPoint T echnologies, Inc.
T able of Contents HIGHPOINT TECHNOLOGIES, INC .....................................5 CONGRA TULA TIONS 1 - Specifications and Features ..................................................................................... 6 2 - Kit Contents ..........
HIGHPOINT RAID MANAGEMENT AND DE- VICE DRIVER CD 1 - Creating a Driver Diskette ...................................................................................... 3 6 2 - Device Driver Installation .................................................
HighPoint T echnologies, Inc. HighPoint T echnologies, long recognized as a leader in mass storage technologies specializes in the design and manufacturer of HBA (Host Bus Adapters) and HighPoint RAID IP (Intellectual Property).
Congratulations Congratulations Y ou have purchased one of the highest performing and SAS/SA T A hardware RAID controllers available. The RocketRAID 4300 series offers the performance and data protection features for homogeneous storage environments.
Congratulations Advanced RAID Features • Supports RAID 0,1,3,5,6,10,50 and JBOD • Multiple RAID array support • Multiple logical drive support • BIOS booting support • BIOS PnP and BBS (BIOS.
Congratulations Operating System Support • W indows XP , 2003, V ista, 2008 (32 and 64-bit versions) • Linux (Fedora Core, Red Hat Enterprise / CentOS, SuSE, Debian, Ubuntu) • Mac OS X 10.4.x and above FreeBSD • Freebsd • GPL licensed driver into Linux Kernel 2.
Hardware - Description and Installation 1 – RocketRAID 4320 Adapter layout Port1- Port2 - These represent the RocketRAID 4320’ s 2 Internal Mini-SAS ports. Each port can support up to 4 SAS/SA T A hard disks. J9,J10,J1 1,J12 J9,J10 are Disk Activity LED’ s; J11,J12 are Disk Failure LED’ s.
Hardware – Description and Installation 10 Pin - SAS/SA T A channel/port stable: Pin definitions: Pin 1: SCL; Pin 2: GND; Pin 3: SDA. J14 (BBU connector) Connector for HPTBBU-03.
Hardware – Description and Installation 2 – RocketRAID 4322 Adapter layout Port1, Port2 These represent the RocketRAID ’ s 2 External Mini-SAS ports. Each port can directly support up to 4 SAS/SA T A hard drives. J3 (Battery connector) Connector for the HPTBBU-03 (see “Battery Backup” for details).
Hardware – Description and Installation 2.1 – Installing the RocketRAID 4320 Host Adapter Note: Make sure the system is powered-off before installing the RocketRAID 4320 host adapter. 1. Open the system chassis and locate an unused PCI-E x8 or x16 slot.
Hardware – Description and Installation 2.2 – Installing the RocketRAID 4322 Host Adapter Note: Make sure the system is powered-off before installing the RocketRAID 4322 host adapter. 1. Installing the HighPoint Ethernet Board – the following illustration shows the HighPoint Ethernet Board .
3 - V erifying Installation Once the RocketRAID host adapter and hard drives have been installed into the chassis, boot-up the system to verify that the hardware is properly recognized. 1 . Power on the system. If the system detects the presence of the adapter, the RocketRAID BIOS Utility will be displayed during bootup.
RocketRAID BIOS Utility RocketRAID BIOS Utility The RocketRAID 432x card will display it’ s BIOS screen during the system’ s boot process. Press Control + H when prompted, to access the BIOS settings Menu.
RocketRAID BIOS Utility T o log on as a User , use the arrow keys to highlight “ User mode ”, and press Enter . T o log on as Supervisor , select “ Supervisor Mode” :, and press Enter . BIOS Menu Shortcuts The BIOS interface can also be navigated using key stroke combinations (Alt +” X”).
RocketRAID BIOS Utility Y ou will be asked to enter the Supervisor password. The default password is “ hpt ”. BIOS Commands System User/Supervisor modes – interface modes Change password - for S.
RocketRAID BIOS Utility Array Information – displays information about the selected RAID array Create – Create a RAID array using the selected disks Delete – Delete the selected RAID array Unplu.
RocketRAID BIOS Utility 2 - Cr eating RAID Arrays Initializing Disks: Before creating a RAID array, the disks must be initialized. Disk initialization writes necessary RAID configuration information to the hard disks. 1 . From the Disk window, highlight the target disks using the arrow keys, then select using Enter .
RocketRAID BIOS Utility Creating Arrays: From the Disk window, highlight the target disks using the arrow keys, then select using Enter . A numeral will be displayed before each selected disk. T o de-select a disk, highlight the target disk, and press Enter once more.
RocketRAID BIOS Utility 1. Array T ype: First, use the T ab or arrow keys to highlight the desired RAID level, and press the Spacebar to select the Array T ype. The RocketRAID 432x host adapters support RAID 0, 1, 3, 5, 6, 10, 50 and JBOD. 2. Cache Policy: Specify the Cache Policy of the array.
RocketRAID BIOS Utility 4. Name: Use the T ab or arrow keys and highlight Name . This feature allows you to name an array for reference. This is an optional setting. Press Enter to use the default name, or type in the desired name, and press Enter . 5.
RocketRAID BIOS Utility 8. Sector Size – Also known as VSS (V ariable Sector Size), this option allows you to specify the sector size of the array , for use W ith W indows operating systems. Older , 32-bit versions of W indows do not support volumes over 2TB in size, unless the sector size is altered.
RocketRAID BIOS Utility 3 – Deleting Arrays From the Array window , highlight the target array and press Enter . Highlight Array from the toolbar. Select Delete and press Enter . The utility will display a warning message. Press Y (yes) to delete the array, or select N (no) to cancel.
RocketRAID BIOS Utility 4 – Monitoring the Host Adapter , Arrays and Devices The BIOS Settings Utility allows the Administrator to check the status of the RocketRAID host adapter, and any devices (hard disks), and arrays hosted by the adapter.
RocketRAID BIOS Utility Controller Information Highlight Controller from the toolbar, select Information , and press Enter . Array Information – this will display the array’ s Name, RAID type, Block size, Sector size, member hard disks, and status.
RocketRAID BIOS Utility Use this option to view Event Log information, including Errors (disk or array failure), W arnings (problems such as disk sector or Smart issues) and Information (such as the creation or deletion of arrays).
RocketRAID BIOS Utility 28 5 – Maintaining Arrays The BIOS Settings Utility provides several RAID and device related maintenance functions, including device and controller settings, Network Configuration settings (for managing the host adapter, remotely), and rebuilding broken/degraded RAID arrays.
RocketRAID BIOS Utility 29 Controller Settings Highlight Controller from the toolbar, select Settings and press Enter. Use the tab and arrow keys to select each item, and the Spacebar to enable/disable the target option.
RocketRAID BIOS Utility • Use Single BCV Entry – also related to motherboard BIOS settings (troubleshooting) • Stop on Error – Enabled by default. If disabled, the host adapter BIOS menu will bypass array or device errors when booting the system.
RocketRAID BIOS Utility Spare Disks Spare Disks are used to automatically rebuild Redundant RAID arrays in the case of disk failure. As with creating RAID arrays, disks must be initialized before they can be used as spares.
RocketRAID BIOS Utility Generally, single disks are designated to act as spares (disks that are not configured into RAID arrays). However, in some instances, disks that are members of RAID arrays may also be assigned to act as a spare disk.
RocketRAID BIOS Utility 6 – Additional Functions and Settings Set Boot Highlight the target array from the Array window and press Enter . Highlight Array from the toolbar: Note: Use this option to set an array to act as the boot device.
RocketRAID BIOS Utility T o add a disk, install the hard disk, then highlight Disk from the toolbar , select Rescan , and press Enter . Note: After installing the disk into the hot-swap capable drive bay, wait several seconds to allow the disk to fully power on, before using the Rescan command.
RocketRAID BIOS Utility Window Menu The W indow menu provides several view options. • Maximize – enlarge viewing area of the selected window (Disk or Array) • Minimize – reduce the viewing are.
HighPoint RAID Management and Device Driver CD HighPoint RAID Management and Device Driver CD Each retail box includes a copy of the HighPoint Products Software CD.
HighPoint RAID Management and Device Driver CD 37 2 - Device Driver Installation W e recommend visiting the RocketRAID download page for the latest W indows Device Driver updates: RocketRAID 4320 http://highpoint-tech.com/USA/bios_rr4320.htm RocketRAID 4322 http://highpoint-tech.
HighPoint RAID Management and Device Driver CD 38 Windows Driver Installation (Win2000, XP, Win 2003) Before installing the RocketRAID 432x host adapter ’ s device driver , make sure the host adapter and all required hard disks have been installed into the system’ s chassis/ disk enclosure.
HighPoint RAID Management and Device Driver CD 39 Installation V erification After the driver has been installed, and the system has been restarted: 1 . Click the Start button, then right-click the “My Computer” icon. Select the Properties item from the pop up menu.
HighPoint RAID Management and Device Driver CD 40 Windows V ista/2008 Driver Installation Installing the driver during a fresh Windows Vista/2008 installation 1 . Boot from W indows V ista DVD. 2 . When the screen “ where do you want to install Windows ” appears, click “ Load driver ” and browse for the driver location.
HighPoint RAID Management and Device Driver CD 41 Installation V erification After the driver has been installed, and the system has been restarted: 1 . Click the Start button, then right-click My Computer icon. Select the Properties item from the popup menu.
HighPoint RAID Management and Device Driver CD 42 Several driver sets are included with the RocketRAID 432x Software CD. Each binary driver and source package includes an installation guide (.pdf format). Linux Driver sets: RR3xxx_4xxx/Linux directory.
HighPoint RAID Management and Device Driver CD 43 3 - HighPoint RAID Management Utilities (HRM) The HighPoint RAID Management Utility Suite, also known as “HRM”, includes several user interface options. The latest version of the W eb Management utility user manual, is available from our website.
HighPoint RAID Management and Device Driver CD 44 Red Hat Enterprise/CentOS, Fedora Core, Open SuSE – Installing the W eb-based Management utility Linux operating systems that support .rpm packages, allow you to double-click the HighPoint W eb RAID Management .
HighPoint RAID Management and Device Driver CD 45 Debian/Ubuntu Linux Distributions – Installing the W eb-based Management Utility For Debian/Ubuntu Linux distributions, you can use alien to convert the rpm pack- ages to a .deb package, then use “ dpkg -i ” command to install each package.
HighPoint RAID Management and Device Driver CD 46 Mac OS X Driver and W eb-based RAID Management Utility The driver and software packages for the RocketRAID 4320 and 4322 includes both the device driver for OS X, and a copy of the W eb RAID Management utility .
HighPoint RAID Management and Device Driver CD 47 Click “ Continue ” to proceed with installation Mac OS X Driver and RAID Management Installation The driver and software packages for the RocketRAID 4320 and 4322 includes both the device driver for OS X, and a copy of the W eb RAID Management utility .
HighPoint RAID Management and Device Driver CD 48 Click “ Continue ” Select the installation destination: Click “ Restart ” – after OS X reboots, the card will be recognized by the system. Config- ure arrays using the W eb RAID Management interface.
Customer Support Customer Support If you encounter any problems while utilizing the RocketRAID host adapter, or have any questions about this or any other HighPoint product, feel free to contact our Customer Support Department.
Customer Support 50 Contact Us HighPoint Corporate Headquarter USA Address 1161 Cadillac Ct. Milpitas, CA, 95035 W ebsite: http://www .highpoint-tech.com Phone: 1-408-942-5800 (9 am ~ 6 pm PST, M-F) Fax: 1-408-942-5801 E-mail: sales@highpoint-tech.com Support: support@highpoint-tech.
FCC Part 15 Class B Radio Frequency Interference statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.
Thank Y ou Thank you for purchasing the RocketRAID 432x SA T AII RAID Host adapter . W e appreciate your support, and welcome any questions, comments or product sugges- tions you may have.
Ein wichtiger Punkt beim Kauf des Geräts Highpoint RocketRAID 4322 (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Highpoint RocketRAID 4322 noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Highpoint RocketRAID 4322 - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Highpoint RocketRAID 4322 reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Highpoint RocketRAID 4322 erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Highpoint RocketRAID 4322 besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Highpoint RocketRAID 4322 verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Highpoint RocketRAID 4322. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Highpoint RocketRAID 4322 gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.