Benutzeranleitung / Produktwartung PE-91A PE-121A des Produzenten Heat Controller
Zur Seite of 23
Model: PE-91A PE-121A PORT ABLE AIR CONDITIONER OWNER’S MANUAL COOL - HEA T - DEHUMIDIFY.
SECTION PA G E 1. BEFORE USE ............................................................ 3 2. QUICK SE T UP .......................................................... 4 3. INTRODUC TION ........................................................ 5 4. SUGGESTIONS FOR USE .
3 Heat Controller , Inc. 1900 W ellworth A venue Jackson, MI 49203 Keep your ORIGINAL purchase receipt. Y our receipt is your proof of purchase and may be necessary for warranty service.
4 Heat Controller , Inc. 1900 W ellworth A venue Jackson, MI 49203 QUICK SET UP 2. Unpack the unit: • Remove the foam cap. • With two people, lift and remove the unit from the foam packing base without tilting the unit. • Remove the plastic bag.
5 Heat Controller , Inc. 1900 W ellworth A venue Jackson, MI 49203 INTRODUCTION 3. This Portable Air Conditioner is designed for improving living and working comfort by adjusting the temperature and humidity in a room. Its mobility makes it easy to use in various rooms.
PE-91A / PE-121A Electrical Supply 1 15V / 60 Hz Cooling Capacity (BTUH) 9000 / 12000 Heating Capacity (BTUH) 3412 / 4265 Cooling Am ps 10.0 / 1 1.5 Heating Amps 8.7 / 10.9 Dehumidifying Capacity (Pts/Hr) 2.5 / 2.8 Refrigerant R22 Fan S peeds Low / Med / Hi Airflow (CF M) 210 Noise Level d B (A) 51 / 52 Net Weight (lb) 85.
a. 7 Heat Controller , Inc. 1900 W ellworth A venue Jackson, MI 49203 P ARTS & ACCESSORIES 6. Upper drain port Lower drain port (Rubber plug inside ).
8 Heat Controller , Inc. 1900 W ellworth A venue Jackson, MI 49203 SAFETY 7. Connection to the main electrical s upply must comply with local and national electrical codes. 1. Do not damage the power cord. 2. Never lay this unit down. O perate in upright position only .
9 Heat Controller , Inc. 1900 W ellworth A venue Jackson, MI 49203 This unit is provided with Leakage Curr ent Detection and Interruption circuit (LCDI) built into the plug of the power supply cord. This device provides protection to reduce the risk of fire due to arcing faults in the power supply cord.
10 Heat Controller , Inc. 1900 W ellworth A venue Jackson, MI 49203 INST ALLA TION 8. When this portable air conditioner operates in the cool mode, fresh outdoor air must be directed into the unit and hot air must be exhausted out of the room to complete heat exchange of the condenser .
11 Heat Controller , Inc. 1900 W ellworth A venue Jackson, MI 49203 1. Measure the window the unit will be inst alled into and adjust the telescoping Window Panels to fit into the window . If window is either too wide or too tall, fill the remaining sp ace with foam or other appropriate material.
NOTE: T o toggle the displayed temper ature between °C and °F , press the ON/OFF button for approximately 20 seconds and then release. (The °F printed on the Control Panel will remain unchanged.) . 12 Heat Controller , Inc. 1900 W ellworth A venue Jackson, MI 49203 OPERA TION 9.
TE M P/ T I M E F AN SPEED TI M ER M O DE O N/ O FF 13 Heat Controller , Inc. 1900 W ellworth A venue Jackson, MI 49203 OPERA TION 9. 9.2 Remote Controller Fig. Remote Controller The buttons on the Remote Controller perform the same functions as the equivalent button on the Control Panel.
14 Heat Controller , Inc. 1900 W ellworth A venue Jackson, MI 49203 OPERA TION 9. 9.3 Auto , Cool , Heat , Dr y, Fan Mode Y ou can operate the unit using the Control Panel on the unit, or with the Remote Controller . Auto Mode: 1. Plug the Power Cord into the power outlet.
15 Heat Controller , Inc. 1900 W ellworth A venue Jackson, MI 49203 OPERA TION 9. 9.3 Auto , Cool , Heat , Dr y, Fan Mode Dry Mode: 1. Plug the Power Cord into the power outlet. 2. T urn on the unit by pressing t he ON/OFF Button on the Control Panel.
16 Heat Controller , Inc. 1900 W ellworth A venue Jackson, MI 49203 Press TIMER button. Digit “3” will flash on LED display . TIMER LED indicator will illuminate. OPERA TION 9. 9.4 T imer Setting Procedure ON-TIMER Program Setting: When the unit is OFF , you can program the ON TIMER to start the unit after desired number of hours.
17 Heat Controller , Inc. 1900 W ellworth A venue Jackson, MI 49203 OPERA TION 9. 9.5 Air Flow Direction Control Horizont al Sw ing Strip Press button. The horizontal swing strip contro ls the up-down air direction and will move up and down automatically .
18 Heat Controller , Inc. 1900 W ellworth A venue Jackson, MI 49203 DRAIN EXCESS CONDENSA TE W A TER 10. Condensate Disposal: Drain W ater from Upper Drain Port: Procedures : Connect the W ater Drain House to the Upper Drain Port allowing water to flow to a wa ter bucket.
19 Heat Controller , Inc. 1900 W ellworth A venue Jackson, MI 49203 MAINTENANCE 11 . MAKE SURE POWER SUPPL Y IS SWITCHED OFF AND THE PLUG IS PULLED OUT OF THE POWER OUTLET BEFORE ANY MAINTENANCE IS PERFORMED. • Do not immerse the unit in water or other liquids.
20 Heat Controller , Inc. 1900 W ellworth A venue Jackson, MI 49203 MAINTENANCE 11 . 1 1.1 Storing the Power Cord T o avoid damage to the power cord when t he unit is not in use, always store the power cord at the back of t he unit in its original location (as shown in the figure below).
Problem Cause Solution Power failure or plug is not correctly inserted in the socket Restore the power supply or reset LCDI Circuit breaker or line fuse has been tripped Call your Electrician The unit.
Hr W at er Level De t e c t o r L EFT/ R I G HT Sw i n g M ot or F o r H o ri z o n t a l Sw i n g St r i p Fus e 3. 15A CO M H AC- N L C2 NO LI M I HI W ATER 5C Cu t - o f f C3 S R Co m pr es s or C .
1900 Wellworth Ave., Jackson, Michigan 49203 • Ph. 517-787-2100 • Fax 517-787-9341 THE QUALITY LEADER IN CONDITIONING AIR www.heatcontroller.com Design, material, performance data and component s subject to change without notice.
Ein wichtiger Punkt beim Kauf des Geräts Heat Controller PE-91A PE-121A (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Heat Controller PE-91A PE-121A noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Heat Controller PE-91A PE-121A - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Heat Controller PE-91A PE-121A reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Heat Controller PE-91A PE-121A erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Heat Controller PE-91A PE-121A besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Heat Controller PE-91A PE-121A verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Heat Controller PE-91A PE-121A. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Heat Controller PE-91A PE-121A gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.