Benutzeranleitung / Produktwartung ShowerArc 26396001 des Produzenten Hans Grohe
Zur Seite of 32
ShowerArc 26396001 Installation Instructions / W arranty.
2 ShowerArc 26396001 Minimum ceiling height – 90 1/2”.
3 For best results, Hansgrohe recommends that this unit be installed by a licensed, professional plumber . Please read over these instructions thor- oughly before beginning installation. Make sure that you have all tools and sup- plies needed to complete the installation.
4 Installation in 90º corner: Instructions begin on page 5 W all-to-wall installation Requires 26397000 installation kit (included): Instructions begin on page 13.
5 Only one set of supplies is required – do not install two sets of supplies . Installation in 90º corner The thermostatic mixing valve may be installed on either wall.
6 Installation in 90º Corner Seal the wall around the supplies with waterproof sealant. Failure to seal the wall can lead to possible water damage. 1 2 3 4.
7 Seal the wall around the anchors with waterproof sealant. Failure to seal the wall can lead to possible water damage. 5 6 7 8.
8 Seal the wall around the anchors with waterproof sealant. Failure to seal the wall can lead to possible water damage. Be careful not to drill into water lines! 9 10 11 12 6 mm.
9 13 14 15 16.
10 1 2 17 18 19 20 6 mm.
11 Seal the wall around the anchors with waterproof sealant. Failure to seal the wall can lead to possible water damage. 1 2 21 22 23 24 6 mm.
12 T urn to page 22 to continue the installation. Seal the wall around the anchors with waterproof sealant. Failure to seal the wall can lead to possible water damage.
13 The thermostatic mixing valve may be installed on either wall. The diagram shows both possible positions for the installation. Only one set of supplies is required – do not install two sets of supplies .
14 W all-to-W all Installation Seal the wall around the supplies with waterproof sealant. Failure to seal the wall can lead to possible water damage. 1 2 3 4.
15 Seal the wall around the anchors with waterproof sealant. Failure to seal the wall can lead to possible water damage. 5 6 7 8.
16 Seal the wall around the anchors with waterproof sealant. Failure to seal the wall can lead to possible water damage. Be careful not to drill into water lines! 1 2 6 mm 12 9 10 11.
17 Install the 26397000 mounting set 13 14 15 16.
18 XX 90 XX = 17 18 19 20.
19 6 mm SW 3 mm M6x8 1 2 24 21 22 23.
20 Install the 26397000 mounting set M6x60 1. 2. 3. SW 3 mm M6x8 25 26 27 6 mm 28 Seal the wall around the an- chors with waterproof sealant. Failure to seal the wall can lead to possible water damage.
21 T urn to page 22 to continue the installation. SW 3 mm M6x8 29.
22 Install the Cover , Escutcheon, and Handle Install the Showerhead and Handshower 2 1.
23 Reset the High T emperature Limit Stop Loosen the handle screw with a 3 mm Allen wrench. Remove the retainer clip and stop ring from the stem. T ur n the stop unit to the handshower position. T ur n the temperature control stem until the output water is the desired high temperature -- usually 110º.
24 T ur n the stop unit to the off position. Install the stop ring so that the tooth is against the stop. Install the clip. Install the handle. T ighten the handle screw with a 3 mm Allen wrench.
25 Justify the Handle T ur n the diverter handle to the handshower position. T ur n the temperature control knob until the output water is 100ºF . T ur n the diverter handle to the off position. Loosen the handle screw with a 3 mm Allen wrench. Remove the handle.
26 User Instructions Using the Handshower T ur n the function lever to until the desired spray mode has been obtained. T ur n the temperature control knob to change the tem- perature. T ur n it clockwise to make the water cooler , counter-clockwise to make the water warmer .
27 If necessar y , pour about 3/4” of a commercial scale remover , such as Lime-A way or CLR, into a shallow dish. Soak the spray face for the amount of time shown in the label instructions. Rinse the spray face with clear water . Reinstall the handshower .
28 Replacement Parts 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 17 25.
29 1 wall flange 96768000 2 escutcheon 96767000 3 branch connection 97496000 4 branch connection 97497000 5 shower hose 28276000 6 handshower 28504001 7 handshower holder 28321000 8 body spray 9760300.
30 Problem Possible Cause Solution Unit outputs both hot and cold water , but it does not mix not a product defect -- the hot and cold supplies are reversed correct the plumbing W ater temperature doe.
31 Limited Lifetime Consumer W arranty This product has been manufactured and tested to the highest quality standards by Hansgrohe, Inc. (“Hansgrohe”). This warranty is limited to Hansgrohe products which are purchased by a consumer in the United States after March 1, 1996, and installed in either the United States or Canada.
Hansgrohe, Inc. • 1490 Bluegrass Lakes Parkway • Alpharetta, GA 30004 T el. 770-360-9880 • Fax 770-360-9887 www .hansgrohe-usa.com US - Installation Instructions • Part No.
Ein wichtiger Punkt beim Kauf des Geräts Hans Grohe ShowerArc 26396001 (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Hans Grohe ShowerArc 26396001 noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Hans Grohe ShowerArc 26396001 - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Hans Grohe ShowerArc 26396001 reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Hans Grohe ShowerArc 26396001 erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Hans Grohe ShowerArc 26396001 besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Hans Grohe ShowerArc 26396001 verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Hans Grohe ShowerArc 26396001. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Hans Grohe ShowerArc 26396001 gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.