AD1200EXP MCS Hard-wire Controller Expander Installation Instructions The manual describes the installation procedures for the American Dynamics AD1200EXP MCS Hard-wire Controller Expander. Before installation, become familiar with all of the special features and warnings associated with this equipment.
This software/firmware is confidential to and is copyrighted by SENSORMATIC ELECTRONICS CORPORATION. It is not to be copied or disclosed in any manner without the express written consent of SENSORMATIC. The software is furnished to the purchaser under a license for use on a single system.
The installation of this product should be made by qualified service personnel and should conform to all local codes. QA301D ! W W W W A A A A R R R R N N N N II I I N N N N G G G G To reduce the risk of fire or shock hazard, do not expose this product to rain or moisture.
T able of Contents DESCRIPTION............................................................................................................................ 1 FEATURES .....................................................................................
1 AD1200EXP DESCRIPTION DESCRIPTION The AD1200EXP Hardwired Controller Expander increases the number of pan/tilt sites controlled from a single AD1200A Hard-wired Controller from one to four. Cascading multiple AD1200EXP units increases the number of pan/tilt sites available from four to a maximum of sixteen.
2 INSTALLATION Front Panel Description Site Selection Pushbuttons: Four spring-loaded pushbuttons select the individual pan/tilt unit the operator wishes to control (see Figure 2).
3 AD1200EXP INSTALLATION Figure 3 - AD1200EXP Rear Panel Layout 14- P in C onne c ter s ( 4) 1 2 3 4 U D R L 1 2 R C I F Z N C N C N C U D R L 1 2 R C I F Z N C N C N C 1 2 3 Gr ound C onne c ti on 4 .
4 Mounting The AD1200EXP is suitable for desktop operation or mounting in a standard EIA rack. The American Dynamic's AD2117/21 Rack Mount Hardware Kit is recommended for mounting one or two AD1200EXPs in a standard EIA rack. Power The AD1200EXP is configured for use with 24VAC power.
AD1200EXP INSTALLATION 5 A D1200EX P 1 2 3 4 U D R L 1 2 R C I F Z N C N C N C U D R L 1 2 R C I F Z N C N C N C 0 1 2 3 G 1 2 3 4 AUT O SC AN 120V 60Hz LEN S ADJ UST AUX P/ T A/ P LEN S U D R L 1 2 H.
Cascading Multiple AD1200EXP Units Multiple AD1200EXP units are used to increase the number of pan/tilt sites available to a single AD1200A Hard-wired Controller from four to a maximum of sixteen. Each AD1200EXP unit is provided with one 5-pin strap harness for cascading purposes.
7 AD1200EXP INSTALLATION 1 2 3 4 0 1 2 3 G A D1200EX P 1 2 3 4 0 1 2 3 G 0 1 2 3 G 1 2 3 4 C ha ssis G r ound C onne c ti on ( 1 8 AWG S o l i d Wi re) to AD1200A H a rd- w i r e Cont r oll e r C ha s.
8 Powering Multiple AD1200EXP Units Connecting multiple (maximum of 4) AD1200EXP units to one AD1200A Controller requires the use of an external 120VAC to 24VAC step-down transformer. NOTE: Connecting multiple AD1200EXPs for European operation requires the use of a 230VAC to 24VAC step-down transformer.
9 AD1200EXP INSTALLATION AUT O SC A N 120V 60Hz LEN S ADJ US T AUX P/T A/P LEN S U D R L 1 2 H R C I F Z CP 1 2 3 4 OF F A D1200A Ha r d- w ir e C ontr olle r A D1200EX P Un it #1 24VAC CO MMO N 24VAC.
10 Connecting Multiple AD1200EXP Units A maximum of four AD1200EXP units may be connected to one AD1200A Hard-wired Controller. All AD1200EXP units connect to the AD1200A Hard-wired Controller via a single 14-pin connector (provided with the AD1200 Hard-wire Controller).
11 Figure 8 - Multiple AD1200EXP Unit -to- AD1200A Hard-wired Controller Connection AD1200EXP INSTALLATION U D R L 1 2 R C I F Z N C N C N C U D R L 1 2 R C I F Z N C N C N C 0 1 2 3 G 1 2 3 4 U D R L.
12 AD1200EXP to Pan/Tilt Site Connection The AD1200EXP provides connection ports to four pan/tilt units via 14-pin connectors. NOTE: The AD1200EXP does not provide power to either the pan/tilt or the camera. 1. Using Table 4 as reference, connect each lead from the pan/tilt unit to the appropriate terminal of the 14-pin connector (see Figure 9).
13 AD1200EXP INSTALLATION 1 2 3 4 U D R L 1 2 R C I F Z N C N C N C 0 1 2 3 G 12 3 4 A D1200EX P U D R L 1 2 R C I F Z N C N C N C A D1240 P a n/ T ilt U D R L 1 2 R C I F Z N C N C N C 1 ZOOM FOCUS I.
14 CCTV Switcher System Connection AD1200EXP units provide a 5-pin connector for use with CCTV switcher systems. Each AD1200EXP unit is provided with one 5-pin strap harness and two 5-pin mating connectors.
15 AD1200EXP INSTALLATION 120V 60H z 120V 60H z J1 J2 J2 J1 AD 1416L w / Loopi ng Re a r P a ne l M ONIT OR A B CA MERA J3 M ONIT OR AB CA MERA 12 34 56 7 89 1 0 1 1 1 2 1 4 1 5 1 6 13 J3 AD 1416 w / .
16 SETUP 4-Position DIP Switch A 4-position DIP switch configures the AD1200EXP for the number of operational cameras and for use within a CCTV switching system. The 4-position DIP switch is mounted on the AD1200EXP rear panel (see Figure 12). Using Table 8 as reference, read the following descriptions of each of the four DIP switches.
17 AD1200EXP OPERATION OPERATION Single AD1200EXP Unit Operation A single AD1200EXP unit provides operational control to a maximum of four pan/tilt sites. 1. Press the appropriate pushbutton (1-4) to select the desired pan/tilt site (see Figure 13). 2.
.
APPENDIX.
.
A1 AD1200EXP INDEX Cable Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Auxiliary. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Cascading Multiple AD1200EXP Units . . . . . . . . . . . . . . 6 Connector, 14-Pin .
A2 AD1200EXP DIMENSIONS 1. 74" 44. 5m m 10. 3" 261. 6m m 8. 5" 216m m 12 34 MCS PTZ CONTROLLER EXPANDER.
.
An American Dynamics Product Designed and built by Sensormatic CCTV Systems Division One Blue Hill Plaza Pearl River, New York, 10965 (914) 624-7600 Technical Support Center: 800-442-2225 FAX: (914) 6.
Ein wichtiger Punkt beim Kauf des Geräts American Dynamics AD1200EXP (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie American Dynamics AD1200EXP noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für American Dynamics AD1200EXP - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von American Dynamics AD1200EXP reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über American Dynamics AD1200EXP erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon American Dynamics AD1200EXP besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von American Dynamics AD1200EXP verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit American Dynamics AD1200EXP. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei American Dynamics AD1200EXP gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.