AD-78 III (Gas HSI - Phase 7/FSS) Installation Manual For replacement parts, contact the reseller from which the dryer was purchased or American Dryer Corporation 88 Currant Road Fall River MA 02720-4781 Telephone: (508) 678-9000 / Fax: (508) 678-9447 e-mail: techsupport@amdry.
AD-78 III Retain This Manual In A Safe Place For Future Reference American Dryer Corporation products embody advanced concepts in engineering, design, and safety. If this product is properly maintained, it will provide many years of safe, efficient, and trouble-free operation.
IMPORTANT YOU MUST DISCONNECT AND LOCKOUT THE ELECTRIC SUPPLY AND THE GAS SUPPLY B EFORE ANY COVERS OR GUARDS ARE REMOVED FROM THE MACHINE TO ALLOW ACCESS FOR CLEANIN G , ADJUSTIN G , INSTALLATION, OR TESTING OF ANY EQUIPMENT PER OSHA (Occupational Safety and Health Administration) STANDARDS.
WARNING The dryer must never be operated with any of the back guards, outer tops, or service panels removed. PERSONAL INJURY OR FIRE COULD RESULT. IMPORTANT PLEASE OBSERVE ALL SAFETY PRECAUTIONS displayed on the equipment and/or specified in the installation manual included with the dryer.
Table of Contents SECTION I IMPOR T ANT INFORMA TION .......................................................................... 3 A. Receiving and Handling ...............................................................................................
SECTION VII REVERSING TIMER SPIN/DWELL ADJUSTMENTS .................................. 37 SECTION VIII DA T A LABEL INFORMA TION ........................................................................ 38 A. Data Label .................................
3 SECTION I IMPOR T ANT INFORMA TION A. RECEIVING AND HANDLING The dryer is shipped in a protective stretch wrap cover with protective cardboard corners and top cover (or optional box) as a means of preventing damage in transit. Upon delivery , the dryer and/or packaging, and wooden skid should be visually inspected for shipping damage.
4 B. SAFETY PRECAUTIONS W ARNING: For your safety , the information in this manual must be followed to minimize the risk of fire or explosion or to prevent property damage, personal injury , or loss of life. W ARNING: The dryer must never be operated with any of the back guards, outer tops, or service panels r emoved .
5 7. A program should be established for the inspection and cleaning of lint in the burner area, exhaust ductwork, and area around the back of the dryer . The frequency of inspection and cleaning can best be determined from experience at each location.
6 SECTION II SPECIFICA TIONS/COMPONENT IDENTIFICA TION A. SPECIFICA TIONS Shaded areas are stated in metric equivalents * For non-reversing models only . * * A minimum of 3/4 pipe must be supplied to the gas inlet for each dryer . Size of piping to dryer varies with installation conditions.
7 Specifications ADG-78 III (Gas) NOTE: ADC reserves the right to make changes in specifications at any time without notice or obligation..
8 B. COMPONENT IDENTIFICA TION 1. Dryer Front V iew Illus. No. Description 1 Controls 2 Control (top access) Door Assembly 3 Main Door Assembly 4 Lint Compartment Area (lint screen located behind door.
9 2. Dryer Rear V iew Illus. No. Description 1 Heating Unit 2 T op Console 3 * Electric Service Relay Box 4 Basket (tumbler) Bearing Mount Assembly 5 Idler Bearing Mount Assembly 6 Basket (drive) Moto.
10 SECTION III INST ALLA TION PROCEDURES Installation should be performed by competent technicians in accordance with local and state codes. In the absence of these codes, the installation must conform to applicable American National Standards: ANSI Z223.
11 CAUTION: This dryer produces combustible lint and must be exhausted to the outdoors. Every 6 months, inspect the exhaust ducting and remove any lint build up. B. UNP ACKING/SETTING UP Remove protective shipping material (i.e., plastic wrap, and/or optional shipping box) from dryer .
12 c . Remove the four (4) self-tapping screws on the burner box that secure it to t he top of the dryer (refer to the illustration below ). d. Remove the two (2) self-tapping screws on the back electrical box and pull through ALL associated wires from the motor to this electrical box (refer to the illustration below ).
13 C . D R YER ENCLOSURE REQUIREMENTS Bulkheads and partitions should be made of noncombustible materials and must be located a minimum of 12-inches (30.
14 D . F R E S H AIR SUPPL Y REQUIREMENTS When the dryer is operating, it draws in room air, heats it, passes this air through the basket (tumbler), and exhausts it out of the building. Therefore, the room air must be continually replenished from the outdoors.
15 E. EXHAUST REQUIREMENTS 1. General Exhaust Ductwork Information Exhaust ductwork should be designed and installed by a qualified professional. Improperly sized ductwork will create excessive back p.
16 IMPOR T ANT : Exhaust back pressure measured by a manometer in the exhaust duct must be no less than 0 and must not exceed 0.3 inches (0.74 mb) of water column (W .C.). IMPOR T ANT : Minimum ductwork diameter for horizontal venting is 10-inches (25.
17 IMPOR T ANT : Minimum duct size for a dryer that is vented vertically is 12-inches (30.48 cm) for a round duct or an equivalent of 80 square inches (516.
18 F . ELECTRICAL INFORMA TION 1. Electrical Requirements It is your responsibility to have ALL electrical connections made by a properly licensed and competent electrician to assure that the electrical installation is adequate and conforms to local and state regulations or codes.
19 2. Electrical Service Specifications IMPOR T ANT : The dryer must be connected to the electric supply shown on the data label that is affixed to the left side panel area behind the top control (access) door . In the case of 208 V AC or 230/240 V AC, the supply voltage must match the electric service specifications of the data label exactly .
20 3. Grounding A ground (earth) connection must be provided and installed in accordance with state and local codes. In the absence of these codes, grounding must conform to applicable requirements of the National Electrical Code ANSI/NFP A NO. 70-LA TEST EDITION, or in Canada, the Canadian Electrical Codes Parts 1 & 2 CSA C22.
21 b. 3-Phase (3ø) W iring Connections (Hookup) - For Non-Reversing Models Only The electrical connections on ALL 3-phase (3ø) gas model dryers are made into the rear service box located at the upper left area of the dryer .
22 1) Gas Models The only electrical input connections to the dryer are the 3-phase (3ø) power leads (L1, L2, L3, and sometimes neutral) and ground. Single-phase (1ø) power for the control circuit is done internally to the dryer . No single-phase (1ø) input connection is required on a 3-phase (3ø) dryer .
23 c . 3-Phase (3ø) W iring Connections (Hookup) - For Reversing Models Only The electrical connections on ALL 3-phase (3ø) gas model dryers are made into the rear service box located at the upper left area of the dryer .
24 G . GAS INFORMA TION It is your responsibility to have ALL plumbing connections made by a qualified professional to assure that the gas plumbing installation is adequate and conforms to local and state regulations or codes.
25 2. T echnical Gas Data a . Gas Specifications b. Gas Connections Inlet connection -------- 3/4 N.P .T . Inlet supply size -------- 3/ 4 N. P . T . (minimum) Btu/hr input -------------- 204,000 (51,408 kcal/hr) 1 ) Natural Gas Regulation is controlled by the dryer s gas valve s internal regulator .
26 3. Piping/Connections ALL components/materials must conform to National Fuel Gas Code Specifications ANSI Z223.1-LA TEST EDITION, or in Canada, CAN/CGA-B149.
27 Consistent gas pressure is essential at ALL gas connections. I t is recommended that a 3/4-inch (19.050 mm) pipe gas loop be installed in the supply line servicing a bank of dryers. An in-line pressure regulator must be installed in the gas supply line (header) if the (natural) gas pressure exceeds 12.
28 H. PREP ARA TION FOR OPERA TION/ST AR T -UP The following items should be checked before attempting to operate the dryer: 1. Read ALL CAUTION , W ARNING , and DIRECTION labels attached to the dryer .
29 I. PREOPERA TIONAL TESTS ALL dryers are thoroughly tested and inspected before leaving the factory . However, a preoperational test should be performed before the dryer is publicly used. It is possible that adjustments have changed in transit or due to marginal location (installation) conditions.
30 NOTE: T o check for proper sail switch operation (for gas models only), open the main door and while holding main door switch plunger in, start dryer .
31 J. PREOPERA TIONAL INSTRUCTIONS 1. T o start the dryer: a . Microprocessor Controller (Computer) Dryers... 1 ) The light emitting diode (L.E.D.) display will read READY . 2 ) Press the E on the keyboard (touch pad). a ) The dryer will then start (rotate).
32 SECTION IV SER VICE/P AR TS INFORMA TION A. SER VICE 1. Service must be performed by a qualified trained technician, service agency , or gas supplier .
33 SECTION V W ARRANTY INFORMA TION A. RETURNING W ARRANTY CARDS 1. Before any dryer leaves the ADC factory test area, a warranty card is placed on the back side of the main door glass.
34 2. Each part must be tagged with the following information: a. Model number and serial number of the dryer from which part was removed. b. Nature of failure (be specific). c . Date of dryer installation. d. Date of part failure. e . Specify whether the part(s) being returned is for a replacement, a credit, or a refund.
35 SECTION VI ROUTINE MAINTENANCE A. CLEANING A program and/or schedule should be established for periodic inspection, cleaning, and removal of lint from various areas of the dryer , as well as throughout the ductwork system. The frequency of cleaning can best be determined from experience at each location.
36 90 DA YS 1. Remove lint from around basket (tumbler), drive motors, and surrounding areas. 2. Remove lint from gas valve burner area with a dusting brush or vacuum cleaner attachment. 3. Clean any lint accumulation in and around both the blower and drive motor casing openings.
37 SECTION VII REVERSING TIMER SPIN/DWELL ADJUSTMENTS T imer models have an electronic reversing timer in the electrical service box, which is located in the upper left rear area of the dryer .
38 SECTION VIII DA T A LABEL INFORMA TION A . D A T A LABEL When contacting American Dryer Corporation , certain information is required to insure proper service/parts information from ADC . This information is on the data label that is affixed to the left side panel area behind the top control (access) door .
39 THE DA T A LABEL 1. MODEL NUMBER The model number is an ADC number , which describes the size of the dryer and the type of heat (gas, electric, or steam). 2. SERIAL NUMBER The serial number allows ADC to gather information on your particular dryer .
40 SECTION IX PROCEDURE FOR FUNCTIONAL CHECK OF REPLACEMENT COMPONENTS 1. Microprocessor Controller (Computer) Board a . Upon completing installation of the replacement microprocessor controller (computer) board, reestablish power to the dryer . b. S tart the drying cycle by pressing any of the preset cycles in letters A-F .
41 2. For Models W ith Hot Surface Ignition (HSI) Module (CE V ersion) a . Upon completing installation of the replacement HSI module, reestablish power to the dryer . b. The HSI module s red indicator light will light for up to approximately 5-seconds (self check routine).
42 SECTION X BURNER AND BASKET (TUMBLER)/LINT CHAMBER MANUAL RESET HI-LIMIT INSTRUCTIONS IMPOR T ANT MANUAL RESET HI-LIMIT INSTRUCTIONS FOR PHASE 7 MODELS This dryer was manufactured with a manual reset burner hi-limit and basket (tumbler)/lint chamber hi-limit thermostat which is monitored by the Phase 7 computer.
43 IMPOR T ANT MANUAL RESET HI-LIMIT INSTRUCTIONS DUAL TIMER MODELS ONL Y This dryer was manufactured with a burner manual reset hi-limit thermostat, and a lint/basket (tumbler) manual reset hi-limit thermostat.
ADC 113340 1 - 08/28/01-15 2- 09/27/01-25 3* 03/25/02-25.
Ein wichtiger Punkt beim Kauf des Geräts American Dryer Corp. Gas HSI - Phase 7/FSS AD-78 III (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie American Dryer Corp. Gas HSI - Phase 7/FSS AD-78 III noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für American Dryer Corp. Gas HSI - Phase 7/FSS AD-78 III - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von American Dryer Corp. Gas HSI - Phase 7/FSS AD-78 III reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über American Dryer Corp. Gas HSI - Phase 7/FSS AD-78 III erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon American Dryer Corp. Gas HSI - Phase 7/FSS AD-78 III besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von American Dryer Corp. Gas HSI - Phase 7/FSS AD-78 III verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit American Dryer Corp. Gas HSI - Phase 7/FSS AD-78 III. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei American Dryer Corp. Gas HSI - Phase 7/FSS AD-78 III gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.