Inhaltsverzeichnis 14 Abschnitte ADMP / ADM / ADMR Atmospheric commercial water heater · ADMP / ADM / ADMR - 40/50/60/80/90/115/135 · ADMP / ADM / ADMR Technical specifications · ADMP / ADM / ADMR Dimensions ADM / ADMR · … AnzeigenAusblenden
Page 1 of the A.O. Smith ADMP - 80 user manual — ADMP / ADM / ADMR Atmospheric commercial water heater
Seite 1 · Zum Vergrößern klicken
Seite 1

ADMP / ADM / ADMR Atmospheric commercial water heater

ADMP / ADM / ADMR - 40/50/60/80/90/115/135

A.O. Smith ADMP - 80 — ADMP / ADM / ADMR Atmospheric commercial water heater diagram (page 1)
Abb. 1 · ADMP / ADM / ADMR Atmospheric commercial water heate…
  • An extensive range of atmospheric water heaters to suit most larger hot water systems
  • Effi cient, automatic hot surface igniter
  • Removable control column for convenient servicing
  • Frostprotection thermostat
  • Stainless steel burner for natural or LP gas
  • Two access covers for comprehensive waterside tank maintenance
  • External control connection
  • Voltage-free contact for general fault indication
  • Optional ancillaries: Unvented kits
  • Destratifi cation pump kit
  • Powered anode
  • Flue fan kit
  • ADMP Permanent pilot ignition
  • Pilot proving kit available
  • ADM Electronic ignition
  • Control, high limit and energy cut-off thermostats provide triple protection and ensure safe operation
  • ADMR Electronic ignition
  • Flue damper to minimise standing losses
  • ThermoControl for easy and fl exible control / fault diagnosis
  • Programmable for legionella purge cycle
A.O. Smith ADMP - 80 — ADMP / ADM / ADMR Atmospheric commercial water heater diagram (page 1)
Abb. 2 · ADMP / ADM / ADMR Atmospheric commercial water heate…
A.O. Smith ADMP - 80 — ADMP / ADM / ADMR Atmospheric commercial water heater diagram (page 1)
Abb. 3 · ADMP / ADM / ADMR Atmospheric commercial water heate…

Innovation has a name.

Page 2 of the A.O. Smith ADMP - 80 user manual — ADMP / ADM / ADMR Technical specifications
Seite 2 · Zum Vergrößern klicken
Seite 2

ADMP / ADM / ADMR Technical specifications

ADM 40ADM 50ADM 60ADM 80ADM 90ADM 115ADM 135ADMR 40ADMR 50ADMR 60ADMR 80ADMR 90ADMR 115ADMR 135 Gas data natural gas 2H (G20) Input* kW42.256.566.482.598.3126.6143.442.256.566.482.598.3126.6143.4 Output kW32.342.850.262.474.395.8109.832.342.850.262.474.395.8109.8 Inlet pressure mbar2020202020202020202020202020 Burner pressure mbar8.58.58.58.58.58.511.38.58.58.58.58.58.511.3 Gas consumption** m3/h4.05.46.37.99.412.113.74.05.46.37.99.412.113.7 Diameter main orifice mm3.23.23.12.953.23.23.93.23.23.12.953.23.23.9 Max. flue gas temperature °C180200200180180200185180200200180180200185 Flue gas discharge kg/h121.7130.2199.4190.1329.0253.1302.6121.7130.2199.4190.1329.0253.1302.6 Gas data butane 3+ (G30) Input* kW41.655.368.280.796.1123.5138.441.655.368.280.796.1123.5138.4 Output kW32.642.852.862.674.595.8108.532.642.852.862.674.595.8108.5 Inlet pressure mbar3030303030303030303030303030 Burner pressure mbar-------------- Gas consumption** kg/h3.04.05.05.97.09.010.13.04.05.05.97.09.010.1 Diameter main orifice mm1.71.71.71.51.71.72.251.71.71.71.51.71.72.25 Max. flue gas temperature °C180200200180180200185180200200180180200185 Flue gas discharge kg/h125.9129.4183.9205.3344.9255.6319.6125.9129.4183.9205.3344.9255.6319.6 Gas data propane 3+ (G31) Input* kW38.451.163.377.789.6113.0130.138.451.163.377.789.6113.0130.1 Output kW30.039.548.960.169.287.4101.730.039.548.960.169.287.4101.7 Inlet pressure mbar3737373737373737373737373737 Burner pressure mbar-------------- Gas consumption** kg/h2.73.74.55.66.48.19.32.73.74.55.66.48.19.3 Diameter main orifice mm1.71.71.71.51.71.72.251.71.71.71.51.71.72.25 Max. flue gas temperature °C180200200180180200185180200200180180200185 Flue gas discharge kg/h115.2119.9177.5187.4187.4239.4297.1115.2119.9177.5187.4187.4239.4297.1 Draw-off capacity Storage capacity l309357298335278253252309357298335278253252 Max. temperature setting °C7373737373737380808080808080 30 min. ∆T=44°C l6217667679149571118124062176676791495711181240 60 min. ∆T=44°C l937118312581524168420542313937118312581524168420542313 90 min. ∆T=44°C l12531601174921342410299033851253160117492134241029903385 120 min. ∆T=44°C l15682019224027443137392644581568201922402744313739264458 Continuous ∆T=44°C l/h63183698212201453187221456318369821220145318722145 Heating-up time ∆T=44°C min.292618161187292618161187 30 min. ∆T=50°C l54767467580584298410925476746758058429841092 60 min. ∆T=50°C l824104111071341148218082035824104111071341148218082035 90 min. ∆T=50°C l11021409153918782121263129791102140915391878212126312979 120 min. ∆T=50°C l13801777197124152760345539231380177719712415276034553923 Continuous ∆T=50°C l/h55673586410731279164718885567358641073127916471888 Heating-up time ∆T=50°C min.332921191398332921191398 30 min. ∆T=55°C l497612614732766895992497612614732766895992 60 min. ∆T=55°C l7499471006121913471643185074994710061219134716431850 90 min. ∆T=55°C l10021281139917071928239227081002128113991707192823922708 120 min. ∆T=55°C l12551615179221952509314135661255161517922195250931413566 Continuous ∆T=55°C l/h505669785976116214971716505669785976116214971716 Heating-up time ∆T=55°C min.37322321141093732232114109 Electrical data Power consumption W3030303030306050505050505080 Power supply VAC/Hz230 (-15 / +10%) / 502 30 (-15 / +10%) / 50 (+/- 1 Hz) General Anodes -22233442223344 Maximum working pressure bar88 Maximum weight kg504578507573522523581504578507573522523581 Shipping data Weight empty kg195221209238244270329195221209238244270329 Weight incl. packaging kg214242230259265291350214242230259265291350 Width packaging mm780780780780780780910780780780780780780910 Height packaging mm19302140193021401975204520501930214019302140197520452050 Depth packaging mm870870870870870870910870870870870870870910

* Gas data on gross value ** Gas consumption at 15°C and 1013.25 mbar

Page 3 of the A.O. Smith ADMP - 80 user manual — ADM(R) 115
Seite 3 · Zum Vergrößern klicken
Seite 3

ADMP / ADM / ADMR Dimensions ADM / ADMR

A.O. Smith ADMP - 80 — ADMP / ADM / ADMR Dimensions ADM / ADMR diagram (page 3)
Abb. 4 · ADMP / ADM / ADMR Dimensions ADM / ADMR

ADM(R) 115

ADM(R) 135

ADM(R) 40

ADM(R) 50

ADM(R) 60

ADM(R) 80

ADM(R) 90

A 1900 2100 1900 2100 2000 2085 2085 B 1760 1960 1760 1960 1795 1870 1870 D 710 E 800 F 1100 1105 1105 1105 G 150 150 180 180 225 225 225 H 660 675 675 675 J 1840 2040 1840 2040 1935 2010 2010 K 400 205 M 565 575 650 650 N 1605 1810 1605 1810 1640 1715 1715 P 730 740 825 855 R 500 515 500 515 525 600 595 S 1550 1760 1550 1760 1595 1660 1660 1 Cold water (external) R11/2 2 Hot water (internal) Rp11/2 3 Gas control (internal) Rp3/4 (ADM(R) 135 = Rp1) 4 Tank drain valve (internal) Rp11/2 5 T&P valve (internal) 1-11.5 NPT (40-80) Rp11/2 (90-135) 6 Cleaning and inspection opening Ø100

Dimensions in mm. All ADM and ADMR water heaters receive a three years warranty on the tank and one year on parts.

A.O. Smith ADMP - 80 — ADM(R) 115 diagram (page 3)
Abb. 5
A.O. Smith ADMP - 80 — ADM(R) 115 diagram (page 3)
Abb. 6
A.O. Smith ADMP - 80 — ADM(R) 115 diagram (page 3)
Abb. 7
Page 4 of the A.O. Smith ADMP - 80 user manual — ADMP / ADM / ADMR Installation diagrams ADM / ADMR
Seite 4 · Zum Vergrößern klicken
Seite 4

ADMP / ADM / ADMR Installation diagrams ADM / ADMR

1 Pressure reducing valve 3 T&P valve 4 Stop valve 5 Non-return valve 6 Circulation pump 7 Destratifi cation pump 9 Drain valve 10 Gas cock 11 Isolating valve 12 Temperature gauge 14 Hot water outlets 15 Expansion relief valve 16 Expansion vessel 17 Three way valve 18 Water tank 19 Float valve

A.O. Smith ADMP - 80 — ADMP / ADM / ADMR Installation diagrams ADM / ADMR diagram (page 4)
Abb. 8 · ADMP / ADM / ADMR Installation diagrams ADM / ADMR

A Cold water B Hot water C Return circulation D Gas supply E Overfl ow pipe H Expansion vent pipe

A.O. Smith unvented system kits utilise combination valves.

A.O. Smith ADMP - 80 — ADMP / ADM / ADMR Installation diagrams ADM / ADMR diagram (page 4)
Abb. 9 · ADMP / ADM / ADMR Installation diagrams ADM / ADMR

An ADM/ADMP or ADMR water heater should be installed in accordance with local standards and ventilation require- ments (category B11BS).

Further installation and connection details can be found in the Installation & Commissioning Manual.

Unvented

Page 5 of the A.O. Smith ADMP - 80 user manual — ADMP / ADM / ADMR Electrical diagram ADM
Seite 5 · Zum Vergrößern klicken
Seite 5

ADMP / ADM / ADMR Electrical diagram ADM

TERMINAL STRIP CONNECTIONS Earth N Neutral L1 Phase input of controller L2 Phase input of flue gas thermostat L3 Phase output of flue gas thermostat

COMPONENTS A Two-terminal main switch B Flue gas thermostat C Indicator LED “Error” D Indicator LED “Running” E “RESET” button F Burner control G Control thermostat H Frost thermostat J 0/1 switch of controller K Safety thermostat L High-limit thermostat M Extra error sensor N Gas control O Glow igniter P Ionisation rod

CONNECTIONS ON BURNER CONTROL N1 Neutral Earth L’ Phase input of burner control L” Phase output to safety circuit and thermostat circuit TH Phase input of thermostat circuit GV1 Phase output to gas control MAX Phase input of safety thermostat LG Phase output to glow igniter I Ionisation signal detection NO “Normally open” port of the extra error sensor P Phase input of extra error sensor NC “Normally closed” port of the extra error sensor

F1 Fuse

Page 6 of the A.O. Smith ADMP - 80 user manual — ADMP / ADM / ADMR Electrical diagram ADMR
Seite 6 · Zum Vergrößern klicken
Seite 6

ADMP / ADM / ADMR Electrical diagram ADMR

TERMINAL STRIP CONNECTIONS Earth N Neutral L1 Phase input of controller L2 Phase input of program- controlled pump L3 Phase input of continuous pump L4 Phase input of extra error signal L5 Phase input of flue damper motor L6 Phase output of flue damper motor (feedback) L7 Phase input of isolating transformer (primary side) L8 Phase output of isolating transformer (secondary side)

COMPONENTS A Controller B Gas control C Glow igniter D Ionisation rod E Extra error signal F Double-pole mains switch G Program-controlled pump H Continuous pump J Flue damper K Isolating transformer L I/0 switch control M Display/Flat cable N Extra ON mode switch O Connector for the flue gas sensor P Temperature sensor (T2 - bottom of tank) Q Temperature sensor (T1 - top of tank) R Selection resistor

CONTROLLER CONNECTIONS J1 Connector for display to controller J2 Connector for power supply to controller J19 Connector for extra error signal and power supply to flue damper J20 Connector for gas control J21 Connector for program- controlled pump J29 Connector for feedback from flue damper JP2 Connector for ionisation rod and glow igniter JP3 Connector for temperature sensor T2 JP4 Connector for flue gas sensor JP5 Connector for temperature sensor T1 JP6 Connector for selection resistor and feedback from micro-switch JP8 Connector for extra ON mode switch

Data subject to change INT/0808/ADMR/01

Terms and conditions apply, please refer to our website.

F1 Fuse F2 Fuse

www.aosmithinternational.com

Frage zu A.O. Smith ADMP - 80 stellen

Besitzer und unser Team antworten in der Regel innerhalb eines Tages – und Ihre Frage hilft auch anderen weiter.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Noch keine Fragen zu A.O. Smith ADMP - 80

Stellen Sie die erste Frage — andere Nutzer oder unser Team antworten Ihnen.

Originaldokument

A.O. Smith ADMP - 80 PDF-Anleitung

6 Seiten·822 KB·Warmwasserbereiter·PDF
Klicken Sie oben auf eine Seite, um sie hier zu öffnen
Seite 1 / …
100%
Seiten werden geladen…