312865R EN INSTRUCTIONS SDM5 & SDM15 (Manual); SDP5 & SDP15 (Preset) Meters For metered dispense of oils and 50:50 antifreeze/water mix fluids.
Models 2 312865R Models SDM5 Manual Dispen se Electronic Meters Model Number Swivel Extension Description Nozzle Fluid Type 255348 1/2” npt(f) Flexible Extension Automatic, non-drip, quick close Oil.
Models 312865R 3 SDM15 Manual Dispense Electronic Meters Model Number Swivel Extension Description Nozzle Fluid Type 255800 3/4” npt(f) Rigid Extension Non-drip, quick close Oil or Antifreeze 255801.
Models 4 312865R SDP5 Preset Dispense Electronic Meters Model Number Swivel Extension Description Nozzle Fluid Type 255200 1/2” npt(f) Rigid Extension Automatic, non-drip, quick close Oil 255351 1/2.
Models 312865R 5 SDP15 Preset Dispense Electronic Meters Model Number Swivel Extension De scription Nozzle Fluid Type 255353 3/4” npt(f) Rigid Extension Non-d rip, quick close Oil or Antifreeze 2553.
Warnings 6 312865R Warnings The following warnings are fo r the setup, use, grounding, main tenance, and repair of th is equipment. The exclama- tion point symbol alerts you to a general wa rning and the ha zard symbol re fers to procedure-sp ecific risk.
Warnings 312865R 7 FIRE AND EXPLOSION HAZARD When flammable flui ds are present in th e work area, such as gasoline and windshield wiper fluid, be aware that flammable fume s can ignite or explode. To help pre vent fire and explosion: • Use equipment only in well ventilate d area.
Installation 8 312865R Installation Typical Installations (F IG . 1) The typical installatio n shown in F IG . 1 is only a guide. It is not a complete system design. Contact your Graco distributor f or assistance in d esigning a s ystem to suit your needs.
Installation 312865R 9 Pressure Relief Procedure This equipment will stay pressurized until the pressure has been m anually relieved. To reduce t he risk of serious injury from pressurized fluid, accidental spray from the dispense valve or splashing fluid, follow this Pressure Relief Procedure when ever you: • Are instructe d to relieve pressure.
Installation 10 312865R 3. Slowly open the main fluid valve. a. Place the hose en d (with no disp ense valve connected) in to a containe r for waste oil.
Installation 312865R 11 Installing Nozzle (F IG . 6) 1. a. Thread new nozzle (33) onto e xtension (2 0). b. With an open-end adjustable wrench on flats of nozzle bushing , tighten firmly. 2. Open automatic tw ist lo ck nozzle and all fluid shut-off valves .
Meter Overview 12 312865R Meter Overview Navigation and Modes 5-Way Menu Navigation Button (F IG . 7) • Includes 4 direction ARROWS (UP, DOWN, LEFT, RIGHT) and a center, ENTER button. • Pressing the direction A RROWS allows user to easily scroll through menus .
Setup Mode Screen s 312865R 13 Setup Mode Screens If you are in Opera tion Mode you must be on the Home Scr een shown in F IG . 10, to access the Setup M ode Screens. ( A complete de scription of the Home Scre en is provided on page 20 ). To display the Home Screen: 1.
Setup Mode Screens 14 312865R Main Setup Screen (F IG . 12) All Meters The Main Setup Screen is the first scree n displayed when you enter the Setup Mo de. This screen displays a list of the available Setup Screens and also includes a link back to the Home Screen.
Setup Mode Screen s 312865R 15 Units/Limit Screen (F IG . 13) For All Meters Sets the units of measurement to pints, quarts, liters, or gallons. Units/Limit Screen Feature s (F IG . 13) All meters include C - E C. Units Mode : Displays measurem ent unit that was selected using the Set Measurement Units button (E ).
Setup Mode Screens 16 312865R Calibrate Screen (F IG . 14) For All Meters Recalibrates the meter for different fluids. Table 1. Calibration Factors • Calibration factors at 70°F (21°C) at 2.0 gpm (7.6 lpm). • Calibration number may vary slightly due to temperature or flow rate.
Setup Mode Screen s 312865R 17 Recalibrating the Meter ( F IG . 14) The meter is shipped from the factory with the defau lt calibration factor for 10W30 mo tor oil - at 70°F (21°C).
Setup Mode Screens 18 312865R Preset Screen (F IG . 15) For Preset Mete rs Only Sets the default preset amounts. Typically, you would enter amounts you most frequently d ispense. Preset Meters include D, P and Q D. Wrench Icon: Returns user to Main Screen.
Setup Mode Screen s 312865R 19 Banner Screen (F IG . 16) For All Meters Creates the information banne r displayed across top of the Home, Manual and Preset Screens. Banner Screen Features D and R D. Wrench Icon: Returns user to Main Screen. R. Banner field: Informa tion line.
Dispensing Fluid and Operation Mode Screens 20 312865R Dispensing Fluid and Operation Mode Screens If you are in the Setu p Mode, to display th e Operation M ode Screens use the UP or DOWN ARROW button to select HOME from the list. Pres s the Cente r ENTER but ton to disp lay the Op eration Mo de Home Sc reen shown in F IG .
Dispensing Fluid and Operation Mode Screens 312865R 21 Manual Dispense (F IG . 19) All Meters See F IG . 19 for terms D - H D. Information Banner: Configurable i nformation banner. Data is input on Setup Mo de Banner Screen , page 19. E. Unit of Measurement : Identifies unit of measurement, pint, quart, ga llon or liter.
Dispensing Fluid and Operation Mode Screens 22 312865R Preset Dispense (F IG . 22) Preset Meters Only See F IG . 22 for terms D - L D. Information Banner: Configurable information banner. Data is input in Setup Mode, Banner Screen, page 19. E. Unit of Measurement : Identifies unit of measurement, pint, quart, gallo n or liter.
Dispensing Fluid and Operation Mode Screens 312865R 23 To modify the amount se lected: a. Use the UP or DOWN ARR OW to scroll up or down to increase or decrease the amoun t shown in fie ld L. Each tim e you press th e UP or DOWN ARROW the amou nt will increase or decrease in increments of 0.
Dispensing Fluid and Operation Mode Screens 24 312865R To dispense in Prese t Mode: If the display was asleep , press any button to wake up the display. 1. From HOME screen, use the UP or DOWN ARROWS to select PRESET (F IG . 24). 2. Press ce nter, ENTER b utton to conf irm selec- tion.
Dispensing Fluid and Operation Mode Screens 312865R 25 Totals Screen (F IG . 26) All Meters See F IG . 26 for terms F, G, M - P F. Home Icon: Returns user to Home Screen. G. Reset: Resets counter (M) to ze ro. M. Resettable Total: Shows cumulative amount that has been dispensed in all modes.
Troubleshooting 26 312865R Troubleshooting • Relieve pressure , page 9, be fore you check or repair the meter. Be sure all other valve s, controls and pump are operating proper ly. • When calling for Technical Assi stance you may be asked to provide the Software Version that is being used by your meter.
Troubleshooti ng 312865R 27 Preset Models only - Trigger does not reset sufficiently to dispense fluid. Excessive dirt buildup is causing trip rod to stick. Clean trip rod or replace (page 30). Order Kit 255889. Meter leaks from twist lock nozzle. • It is important to distinguish between the two causes of this problem.
Troubleshooting 28 312865R Error Codes Error codes are listed belo w. Even in an error condition the unit keeps trac k of the amount dispensed. Wit h any error code displayed you can: • Select Manua l option on Home Screen. Error code is cleared. Unit switches to Manual mode and dispensed amount is di splayed.
Service 312865R 29 Service See Parts List , page 43, for reference numbers include d in the followin g Service instru ctions. Replacing the Battery The low battery and dead battery displays are explained in the Troubles hooting Table , page 26. To change the battery: 1.
Service 30 312865R Trip Rod Repair (SDP5 & SDP15 Meters Only) Disassembly 1. Relieve Pressure , pa ge 9. 2. Use a Torx (T20) wrench to re move 4 corner screws (A) located on the bo ttom of the meter (F IG . 30). Keep these screws for reassembly. 3.
Service 312865R 31 6. Remove two screws (D) holding reed switch boar d to the cover plate (F IG . 34). Keep these screws for reassemb ly. Remove cover ass embly. 7. Remove an d discard o-ring (5 ) (F IG . 35). 8. Remove guard (9) by inserting your thumb or finger behind the cover and pry it loos e.
Service 32 312865R 10. Place meter in a vise as shown in F IG . 3 8. Use new trip rod from your kit (2) or a non-metal rod or dowel to push trip rod th rough meter housin g (F IG . 38 and F IG . 39) far enough to access pin (19) holding together trip rod and trigg er.
Service 312865R 33 Reassembly Use all the new parts provided in the kit. Do not reuse the old parts. 1. Insert ba lls (3) in trip ro d (2) (F IG . 42). 2. Slide spring (1) over trip ro d (2) (F IG . 42). 3. Insert trip rod assembly in opening in mete r housing (F IG .
Service 34 312865R 8. Reinstall reed switch board in mete r housing. Use 2 screws (D) to secure re ed switch PCB to cover plate. Tighten screws until they bottom out. 9. Reconnec t lead (B) to b a ttery by carefully sliding connector over battery t erminals (E) until it snaps securely into p lace under clip (D) (F IG .
Service 312865R 35 12. Replace 4 screws (A). Torque each to 15-25 inch pounds. 13. Install guard (9). F IG . 50 F IG . 51 A A ti11936a ti12009a 9.
SDM5 & SDM15 Man ual Meters Parts 36 312865R SDM5 & SDM15 Manual Meters Parts ( Replacement Danger an d Warning labels, tags and cards are available at no cost.
SDM5 & SDM15 Man ual Meters Parts 312865R 37 34a 34b 34c 24b 24a 24e 24f 24c 24d 19 40 41 52 51 53 34 ti11916b 11 39 28 5 50 24c 49 18 9 32 31 31a 2 Torque to 15-25 IN.
SDP5 & SDP 15 Preset Meters Parts 38 312865R SDP5 & SDP 15 Preset Meters Parts ( Replacement Danger and Warning labels, tags and cards are available at no cost.
SDP5 & SDP 15 Pres et Meters Parts 312865R 39 34a 34b 34c 24c 24b 24e 24f 24c 7 24d 15 6 19 8 3 18 24a 52 51 53 2 34 3a 3b 3c ti10617a 11 28 49 5 9 18a 12 17 / 47 32 31 31a Torque to 15-25 In.
Nozzle (33) and Extension (20) Kits 40 312865R Nozzle (33) and Extension (20) Kits Part No. Description Fluid Type 255852* Automatic, non-dr ip quick close nozzle with rigid extension.
Nozzle (33) and Extension (20) Kits 312865R 41 255857 Non-drip, q uick close, high-flow no zzle with rigid extension Oil and Anti-freeze 255858 Non-drip, q uick close, high flow nozzle with flexible extension Oil and Anti-freeze Part No.
Nozzle (33) and Extension (20) Kits 42 312865R Nozzle (33) Kits Thermal Relief Kits (page 8) 255459* Automatic, non-drip, quick-close nozzle Qty Oil • BODY, nozzle 1 • O-RING, packin g 1 • SPRIN.
Technical Data 312865R 43 Technical Data *Tested in 10W moto r oil. Flow rates vary with fluid pressure, temper ature and viscosity. **Battery re quired to mee t life expectan cy: Energizer ® Alkaline E91 . † At 2.5 gpm (9.5 lpm) , at 70°F (21°C), with 10-weigh t oil and 1 gallon dispensed.
All written and visual data con tained in th is document reflects the latest product info rmation available at the time of publica tion. Graco reserves the right to make changes at any time without notice. For patent information, see www.graco.com/pate nts.
Ein wichtiger Punkt beim Kauf des Geräts Graco SDP5 (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Graco SDP5 noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Graco SDP5 - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Graco SDP5 reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Graco SDP5 erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Graco SDP5 besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Graco SDP5 verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Graco SDP5. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Graco SDP5 gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.