Benutzeranleitung / Produktwartung Hydra-Clean 205-985 des Produzenten Graco
Zur Seite of 16
306–993 Rev . D Supersedes Rev . B and PCN C First choice when quality counts. INSTRUCTIONS-P ARTS LIST INSTRUCTIONS This manual contains important warnings and information. READ AND KEEP FOR REFERENCE. Hydra-Clean ) Pressure W ashers 42 bar , 4.
T able of Contents W arnings 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Setup 5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Operation 8 . . . . . . . . .
W ARNING INJECTION HAZARD Spray from the gun, hose leaks, or ruptured components can inject fluid into your body and cause an extremely serious injury , including the need for amputation. Splashing fluid in the eyes or on the skin can also cause a serious injury .
4 306-993 W ARNING FIRE AND EXPLOSION HAZARD Improper grounding, poor ventilation, open flames or sparks can cause a hazardous condition and re - sult in a fire or explosion and serious injury . Ground the equipment and the object being sprayed. Refer to Grounding on page 5.
5 306-993 Setup Grounding W ARNING FIRE AND EXPLOSION HAZARD Before operating the pump, ground the system as explained below . Also read the section FIRE OR EXPLOSION HAZARD on page 4. Although water generally provides a natural electrical ground, the following equipment must be grounded if the cleaning chemical are volatile.
Setup Connect Hoses and Mount Pump Connect hoses and pump as follows: NOTE: This pump is supplied with a bracket (D) which holds it to the side of a drum. If you want to install the pump on a wall, do not install the hanging bracket.
7 306-993 Setup D U B F M J R P KEY A Barbed Hose Stud B Suction Hose C Pump Intake housing D Bracket E Screw , Lockwasher , and Nut F Pump Runaway V alve G Air Line Lubricator H Pu.
8 306-993 Operation General Information The following instructions are for operation of the Monark 5:1 Ratio Hydra–Clean Pressure W ashers Model 205–985 and Model 207–860.
Operation W ARNING T o avoid serious injury , including fluid injection and splashing in the eyes or on the skin, never point the gun at yourself or anyone else. Before Using See Fig. 2. Prepare cleaning solution as instructed, observing all safety precautions.
10 306-993 T roubleshooting W ARNING T o reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the Pressure Relief Procedure on page 8. Before servicing this equipment always make sure to relieve the pressure .
11 306-993 Service General W ARNING T o reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the Pressure Relief Procedure on page 8. See Parts illustration for referenced items. Shut of f the air supply to the pump and relieve the pressure .
12 306-993 Parts 0676 8 17 (MODEL 205–985) 11 4 13 2 18 15 21 19 14 16 20 3 5 12 6 Model 205–985 Monark Hydra-Clean and Model 207–860 Monark Hydra-Clean 1 7 8 8 9 10 (MODEL 207–860) 22 23.
13 306-993 Parts Model 207–860 Monark Hydra-Clean Ref No. Part No. Description Qty . 1 214–847 AIR LINE LUBRICA TOR 1 2* 206–300 FIL TER, fluid intake 1 3 224–343 5:1 Ratio Monark Pump See man.
14 306-993 Accessories Stainless Steel Spray Tips AIR SUPPL Y T O PUMP TIP NO. ORIFICE SIZE SPRA Y ANGLE 70 PSI (4.8 bar , 0.48 MPa) 100 psi (7 bar , 0.7 MPa) NO . SIZE ANGLE GPM CFM WP GPM CFM WP 164–435 .043 40 160–964 .043 25 164–434 .052 25 164–436 .
15 306-993 Dimensions 24.5” (622 mm) 1 1.75” (298 mm) T echnical Data Air pressure range 40 to 120 psi (2.8 to 8.4 bar , .28 to .84 MPa) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Air volume requirements 8.
16 306-993 Graco Standard W arranty Graco warrants all equipment referenced in this document which is manufactured by Graco and bearing its name to be free from defects in material and workmanship on the date of sale by an authorized Graco distributor to the original purchaser for use.
Ein wichtiger Punkt beim Kauf des Geräts Graco Hydra-Clean 205-985 (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Graco Hydra-Clean 205-985 noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Graco Hydra-Clean 205-985 - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Graco Hydra-Clean 205-985 reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Graco Hydra-Clean 205-985 erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Graco Hydra-Clean 205-985 besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Graco Hydra-Clean 205-985 verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Graco Hydra-Clean 205-985. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Graco Hydra-Clean 205-985 gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.