309524N Instr uctions High Pressure Fluid Heater VISCON HP Used f or v ariable heating of fluids. 7250 psi (50 MP a , 500 bar) Maximum W orking Pressure Important Safety Instructions Read all warnings and instr uctions in this manual. Sav e these instr uctions.
Models 2 309524N Models Hazar dous Location Heaters See Special Conditions fo r Saf e Use on page in W ar nings Section. Non-hazar dous Location Heaters Pa r t No. Series V A C (50/60 Hz single phase) / W atts / Amps Appro vals 245848 A 120 / 2300 / 19.
Contents 309524N 3 Contents Models . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 T ranslatio ns . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Manual Con ventions . . . . . . . . . . . . . . . . . . . . . . .
Warning 4 309524N W A RNING SKIN INJ ECTION HAZAR D High-pressure fluid from gu n, hose leaks, or ruptur ed components will pierce skin. This ma y look like just a cut, b ut it is a serious injury that can result in amputa tion. Get immediate su rgical treatment.
Warning 309524N 5 EQUIPMENT MISUSE HAZARD Misuse can cause serious injury or death. • F or prof essional use only . • Use equipment only f or its intended purpose. Call y o ur Graco distributor f or inf or mation. • Read manuals , warnings, tags, and labels bef ore operating equip ment.
Installation 6 309524N Installation T ypical Installation Dra wing The typical installation drawing is only a guide. Y our Graco distr ibutor can as sist in designing your system.
Installation 309524N 7 I Selecting T ubing Fluid loses some heat th rough the tubing or hose betwee n the heater and spr ay gun. Locate heater clo se to the spra y area to minimize heat loss throu gh plumb- ing. The chart in F IG . 2 shows a he at loss cur v e for 3 com- mon types of tubing.
Installation 8 309524N Mounting Heater W all Mounting Bracket 192585 (F IG . 3) 1. Use M8 bolts of appropriate length and loc kwasher (CC), not supplied, to mo unt brac ket. 2. Install two scre ws (6) and washers (5) into top 2 heater mounti ng posts (BB) until the y are about 1/8 in.
Installation 309524N 9 Car t Mounting (F IG . 5) 1. Place clamps (AA) around the car t vertical post (DD) and secure to the heat er mounting bars (ZZ) with M8 x 1.25 x 30 mm bolts (6) and loc kwasher (5). 2. Obser ve temperat ure ratin gs f o r the po wer cable to the terminal junction.
Installation 10 309524N Electrical Connections Requirements For All Installations 1. The volt age supply m ust agree with the maximum heater voltage and amperage. See Models , page 2. 2. Conductors used f or supply connection must be suitab le f or at least 221°F (10 5°C).
Installation 309524N 11 W all Mounted Wiring Mount a 2-pole , explos ion-proof electric s witch (H) near the heater . See F IG . 7. The s witch must meet the electri- cal codes f or your location. Also use the cor r ect cab le and plug. Car t Mounted Wiring Connect a plug that meets the electr ical codes for y o ur location.
Installation 12 309524N Determining Pr oper Fluid T emperature Use the low est temperature setting po ssible f or maxi- mum heater lif e. Use the char t in F IG . 9 to de termine the Under-Boil ® temperature. F IG . 9 also shows the eff ect of temperat ure on reducing viscosit y .
Installation 309524N 13 The char t in F IG . 10 shows the ef f e ct of tempe rature in reducing two fluids to a spra yab le viscosity , between 20 and 34 seconds using a No . 2 Zahn cup . Note that te mperature has more of an eff ect on hig h solid fluids th an on thin en amels.
Operation 14 309524N Operation Pressure Relief Pr ocedure F ollow Pressure Rel ief Pro cedure when y ou stop spra ying, and bef ore cleaning, checkin g, or ser vicing equipment. 1. Enga ge the gun s afe ty lock. 2. Sh ut off main power to the heater .
Operation 309524N 15 Setting Heater Contr ol (Refer to F IG . 11) 1. Set the heater control knob (33) to a trial setpoint of 4 or 5. 2. Star t the pump and circulate fluid thr ough the sys- tem at very low pressure, about 10-1 2 oz/min (0.30-0.35 liter/min).
Maintenance 16 309524N Maintenance Flushing Clogged fluid pa ssages are dif f icult to clean and reduce heating efficiency , flow rate , and pressure. Fl ush fre- quently , including whene ver system is not in use . 1. Follow Pressu re Relief Pro cedure , page 14.
Troubleshooting 309524N 17 T r oubleshooting Prob lem Cause Solution Heater will not heat. No current . Check circuit and fuses . Check continuity of pr imar y ther mo- stat (24), bac kup ther mostat (10), and thermal limit sensor (15). Check continuity of ther mosta t (10) and heater b lock (3) terminals - Page 18.
Repair 18 309524N Repair Hazardous Location Heaters: See F IG . 15 & 17 Non-hazar dous Location Heater s: See F IG . 16 & 18 Primary Thermostat & Probe 1. Follow Pressu re Relief Pro cedure , page 14. 2. Re mov e housing cover (18). 3. Hazardous Location Heater only: Loosen nut (27).
Repair 309524N 19 F IG . 15: Thermostat Re pair – Hazardous Location Heaters 6 Apply thermal lubr icant T orque to 89 in-lb (10 N•m) T orque nuts (62) to 10-12 in-lb (1.1-1.3 N•m) 1 2 3 5 2 16 19 15 HH 16 10 1 EE 1 3A GG 18 24 27 35 FF 1 26 28 TI12335C 25 REF.
Repair 20 309524N Thermal Limit Sensor 1. Follow Pressu re Relief Pro cedure , page 14. 2. Re mov e housing cover (18). 3. Remove nut (FF) and nut (3B) holding the le ads of the thermal limit sensor (15) an d remove the sensor . See F IG . 15 or 16, page 19.
Repair 309524N 21 F IG . 17: Contr ol Repair – Hazardous Location Heaters T orque to 89 in-lb (10 N •m) Electrical Housing Junction Bo x Apply sealant T orque nuts (62) to 10-12 in-lb (1.1-1.3 N•m) 1 2 3 4 5 1 TI2334E 6 5 18 24 29 6 5 9A 1 2 3 4 10 15 REF.
Parts 22 309524N Pa r t s Hazar dous Location Heaters ti2334E 6 5 18 24 27 25 35 26 28 29 30 33 12 16 19 15 16 10 6 5 REF. 1 1 9 2 3 7 8 5 6 32 14, 43 14, 36 4 3 T orque to 89 in-lb (10 N•m) Apply sealant Apply thermal lubr icant T orque nuts (62) to 10-12 in-lb (1.
Parts 309524N 23 Hazar dous Location Heaters ▲ Replacement Danger and W ar ning labels, tags and cards are av ailable at no cost. Pa r t N o . S e r i e s Ref. No. 3 Heater Bloc k P ar t No. V olts / W atts 245848 A 246616 120 / 2300 245862 A 246617 200 / 4000 245863 A 246618 240 / 4000 245864 A 246619 480 / 4000 246254 A 246620 380 / 4000 Ref.
Parts 24 309524N Non-Hazar dous Location Heaters 12 24 52 15 10 9 5 18 47 26 28 27 35 25 29 30 33 32 2 3 31 5 6 8 16 19 16 14, 36 14, 43 T orque to 89 in-lb (10 N•m) Apply sealant Apply thermal lubr icant T orque nuts (62) to 10-12 in-lb (1.
Parts 309524N 25 Non-Hazar dous Location Heaters ▲ Replacement Danger and W ar ning labels, tags and cards are av ailable at no cost. Pa r t N o . S e r i e s Ref.
Accessories 26 309524N Accessories Heater Con version Kit 246302: Includes two fit tings to make VISCON HP por ts match VISCON 2 Mounting Bracket 192585: Eur opean v ersion (see below) Measurements .
Accessories 309524N 27 Cable Clamp Ki t 246303 Installation 1. Slide cable clamp (3) ont o cable (2). 2. Place washer (F) on fitt ing (E). 3. Push conical-shap ed packing (D) into fitt ing (E). 4. Place washer (C) on retaining nut ( B). 5. Screw retaining n ut (B) into fitting (E).
Technica l Data 28 309524N T ec hnical Data The heater can be used in the f ollowing en vironmental conditions: indoor use , 99% maximum rela tiv e humidity , pollu- tion degr ee 2, installation cate gor y II, maximum ambient temp erature 135° F (57° C).
Dimensions 309524N 29 Dimensions Measurements – inch es (mm) L K G H J 1/2 npt(m) Fluid Inlet 1/2 npt(f) Fluid Outlet 3/4 npt(f) Electrical Conduit P or t GH J K L 9.
All written and visual data contained in this document reflects the latest product information available at the time of publica tion. Graco reserves the right to make changes a t any time without notice. This manual contains English. MM 309524 Graco Headquarters: Minneapolis International Offices: Belgium, China, Japan, Korea GRACO INC.
Ein wichtiger Punkt beim Kauf des Geräts Graco 309524N (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Graco 309524N noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Graco 309524N - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Graco 309524N reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Graco 309524N erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Graco 309524N besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Graco 309524N verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Graco 309524N. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Graco 309524N gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.