ST AINLESS STEEL, W A TERBASE COMP A TIBLE Fluid Pressure Regulators Used to regulate fluid pressure in low pressure systems only . Fluid Flow up to 3 GPM (1 1 liters/min) Instructions–Parts List 307212ZAC EN Important Safety Instructions Read all warnings and instructions in this manual.
2 307212 T able of Contents Models 3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . W arnings 5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Installation 6 . . . . . . . . . . . . . . . .
3 307212 Models Spring Operated Fluid Regulators Part No. Series Maximum Fluid Inlet Pressure, psi (kPa, bar) Regulated Pressure Range, psi (kPa, bar) Gauge Gauge Pressure Range, psi (kPa, bar) 214895 H 250 (1800, 18) 5–100 (34–700, 0.3–7) No n/a 214706 H 250 (1800, 18) 5–100 (34–700, 0.
4 307212 Notes.
5 307212 W ARNING PRESSURIZED EQUIPMENT HAZARD Spray from the gun, hose leaks, or ruptured components can splash fluid in the eyes or on the skin and cause serious injury .
6 307212 Installation FLUID SUPPL Y INLET BALL V A L VE OUTLET BALL V A L VE PIPE NIPPLES BACK PRESSURE VA LV E FLUID RETURN AIR FIL T ER & REGULA TOR Spring Operated Installation Models 214895, 2.
7 307212 Installation Fluid pressure regulators are used for accurate, posi- tive control of the fluid pressure to spray guns, dis- pensing valves or atomizing heads. Regulators installed at circulating line take-offs or pumps are used to reduce main line pressure and maintain the desired fluid pressure to the spray gun or atomizing head.
8 307212 Operation CAUTION The new system must be cleaned and tested thoroughly before admitting fluid to the regulator to avoid contaminants clogging or damaging the regulator . Always use the lowest possible air and fluid pressures for your application.
9 307212 Operation 7. Adjust the fluid regulator to the desired setting. a. Spring Operated Regulators Only (see Fig. 3). The regulator can be adjusted in two ways: Using the male end (B) of the regulator key (24), turn the socket–head adjustment screw (19) fully clockwise .
10 307212 Notes.
11 307212 T roubleshooting W ARNING T o reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the Pressure Relief Procedure on page 8. Before servicing this equipment always make sure to Relieve the Pressure .
12 307212 Service Service of the Air Operated Regulators W ARNING T o reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the Pressure Relief Procedure on page 8. 1. Shut off the pump. 2. Close the ball valve at the regulator ’ s air inlet.
13 307212 Service Models 214980 (shown) & 244375 29 10 13 23 7 1 17 22 26 18 9 15 16 4 20 40 6 21 3 NOTE: Numbers indicate tightening sequence. T ighten evenly to 7–10 in-lb (0.8–1.1 N m), then retorque to 125 in-lb (14 N m) three times, consecu- tively , to compensate for diaphragm relaxation.
14 307212 Service Service of the Spring Operated Regulators W ARNING T o reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the Pressure Relief Procedure on page 8. 1. Shut off the pump. 2. Close the ball valve at the regulator ’ s fluid inlet.
15 307212 Service 10 Models 217314 and 221 1 18 Models 214895, 214706, 255374, and 24A082 21 12 13 22 25 17 26 3 15 16 23 40 6 9 18 4 20 1 7 10 21 12 13 22 17 26 3 15 16 23 40 6 9 18 4 20 1 5 2 4 6 1 3 BOTTOM VIEW PET NOTE: Numbers indicate tightening sequence.
16 307212 Parts 24 7 19 14 12 11 5 10 *21 *3 *9 27 28 23 4* *15 *16 *20 40* 1 6 18 26* 22* 17 13 Model 214895, Series H Without gauge. Includes items 1–26, 40 Model 214706, Series H With gauge. Includes items 1–40 Model 214706 only Ref No.
17 307212 Parts 24 7 19 14 12 11 5 10 *21 *3 *9 27 23 4* *15 *16 *20 40* 1 6 18 26* 22* 17 13 TI0037 Model 255374, Series A Model 24A082, Series A ISO pitch thread inlet and outlet (n ot compatible with US standard pitch – fluid housing coated with PTFE based polymer) Includes items 1–40 Ref No.
18 307212 Parts 24 7 19 14 12 11 5 10 *21 *3 *9 27 28 23 4* *15 *16 *20 40* 1 6 32 18 26* 25* 17 13 Model 221 1 18 only Model 217314, Series F With gauge. Includes items 1–32, 40 Model 221 1 18, Series E Without gauge.
19 307212 Parts Model 214980 Series F Includes items 1–40 *9 7 29 10 *21 *3 27 28 *15 *16 *20 40* 4* 23 1 18 26* 22* 17 13 6 Ref No. Part No. Description Qty . Ref. No. Part No. Description Qty . 1 100644 SCREW , soc hd cap; 0.
20 307212 Parts TI1697A Model 244375 Series B Includes items 1–41 *9 7 10 *21 *3 *15 *16 *20 40* 4* 23 1 18 26* *22 13 6 29 17 19 41 Ref No. Part No. Description Qty . Ref. No. Part No. Descri ption Qty . 1 100644 SCREW , soc hd cap; 0.
21 307212 Dimensions Model 244375: 3” (76.2 mm) All Other Models: 4.94” (125.5 mm) 1.76” (44.7 mm) 1.8” (46 mm) 3/8 npsm female INLET 3.65” (93 mm) DIA.
22 307212 T echnical Data Category Data Maximum Fluid Inlet Pressure 250 psi (1.8 MPa, 18 bar) Regulated Fluid Pressure Range Models 217314 & 221 1 18: 20–160 psi (0.15–1.1 MPa, 1.5–1 1 bar) Models 214706, 214895, 244375, 255374, & 24A082: 5–100 psi (30–700 kPa, 0.
23 307212 Performance Chart 0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 0123 45 FLUID FLOW kPa bar p si gpm liters/min 0 10 20 30 40 50 60 70 80 90 100 0123 45 3.
24 307212 Graco Standard W arranty Graco w arrants all equipment manufactured by Graco and bearing its name to be free from defects in material and workmanship on the date of sale to the original purchaser for use.
Ein wichtiger Punkt beim Kauf des Geräts Graco 307212ZAC (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Graco 307212ZAC noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Graco 307212ZAC - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Graco 307212ZAC reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Graco 307212ZAC erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Graco 307212ZAC besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Graco 307212ZAC verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Graco 307212ZAC. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Graco 307212ZAC gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.