Benutzeranleitung / Produktwartung GMH95 des Produzenten Goodman Mfg
Zur Seite of 15
C US ® RT6612018 Rev. 5 April 2010 GMH95 40" 95% Gas Furnace • Refer to Service Manual RS6610004 for installation, operation, and troubleshooting information. • All safety information must be followed as provided in the Service Manual. • Refer to the appropriate Parts Catalog for part number information.
PRODUCT IDENTIFICA TION 2 Minior Revision A 3 Description Air Flow Direction KBTUH AFUE Major Revision Maximum CFM @ 0.5" ESP 3 : 1200 4 : 1600 5 : 2000 Cabinet Width The model and manufacturing number are used for positive identification of component parts used in manufacturing.
PRODUCT IDENTIFICA TION 3 GMH950453BXA* GMH950703BXA* GMH950704CXA* GMH950904CXA* GMH950905DXA* GMH951155DXA* The model and manufacturing number are used for positive identification of component parts used in manufacturing. Please use these numbers when requesting service or parts information.
4 PRODUCT DESIGN 3. Conversion kits for high altitude natural or propane gas operation are available. See High Altitude Derate chart for details. 4. Installer must supply the following gas line fittings, de- pending on which entrance is used: Left -- Two 90º Elbows, one close nipple, straight pipe.
5 COMPONENT IDENTIFICA TION Upflow/Horizontal 1 Gas Valve 2 Gas Line Entrance (Alternate) 3 Pressure Switch 4 Gas Manifold 5 Combustion Air Intake Connection / “Coupling” 6 Hot Surface Igniter 7 R.
COMPONENT IDENTIFICA TION 6 GMH95*****XA* Cabinet Size A B C D E 13-5/ 8 17-1/ 2 20-7/ 8 All d imensions ar e in inches. 24-1/ 2 12-1/ 8 16 19-3/ 8 12-1 5/16 15-1 5/16 20-7/16 GMH950453B XA* GMH950703.
7 PRODUCT DESIGN TRIP POIN T COIL COVER PRESSURE SWITCH COIL C OVER PRESSURE SWITCH PART # TRIP POI NT ID BLOWER PRESSURE SWITCH ID B LOWER PRESSURE SWITCH PART # TR IP POI NT COIL C OVER PRESSURE SWITCH TRIP POI NT ID BLOWER PRESSURE SWITCH HIGH ALTITUDE KIT GM H950453BXA* -1.
8 PRODUCT DESIGN P ar t N u mb er 10123514 o r 10123533 O pe n S e tt ing ( ° F ) 200 G M H 950453B XA * 1 G M H 950703B XA * 2 G M H 950704C XA * 2 G M H 950904C XA * 2 G M H 950905D XA * 2 G M H 95.
9 PRODUCT DESIGN Coil Matches: A large array of Amana ® brand coils are available for use with the GMH95 furnaces, in either upflow or horizontal applica- tions. These coils are available in both cased and uncased models (with the option of a field installed TXV expansion device).
10 PRODUCT DESIGN Filters: Filters are required with this furnace and must be provided by the installer. The filters used must comply with UL900 or CAN/ULCS111 standards. Installing this furnace without filters will void the unit warranty. This furnace has provisions for the installation of return air filters at the side and/or bottom return.
FURNACE SPECIFICA TIONS 11 1. These furnaces are manufactured for natural gas operation. Optional kits are available for conversion to propane operation. 2. For elevations above 2000 feet the rating should be reduced by 4% for each 1000 feet above sea level.
BLOWER PERFORMANCE SPECIFICA TIONS 12 1. CFM in chart is without filters(s). Filters do not ship with this furnace, but must be provided by the installer. If the furn ace requires two return filters, this chart assumes both filters are installed. 2. All furnaces ship as high speed cooling and medium-speed heating.
BLOWER PERFORMANCE SPECIFICA TIONS 13 30 40 50 60 70 80 90 110 12 0 100 13 0 140 150 100 90 80 70 60 50 40 30 20 10 OUTPUT BTU/H R x 1000 BTU OUTPUT vs T EMPERAT UR E RISE CHART T EM PER AT U R E R IS E 600 CFM 700 900 1000 1100 1200 1400 1600 1800 2000 2200 2400 CFM FORMULAS BTU OUTPU T = CFM x 1 .
14 WIRING DIAGRAMS Wiring is subject to change, always refer to the wiring diagram on the unit for the most up-to-date wiring. GMH95[0453,0704,0905]*XAB GMH95[0703,0904,1 155]*XAC HIGH VOL T A GE! DISCONNECT ALL POWER BEFORE SERVICING OR INS T ALLIN G THIS UNIT .
15 WIRING DIAGRAMS Wiring is subject to change, always refer to the wiring diagram on the unit for the most up-to-date wiring. GMH95[0453,0704,0905]*XAC GMH95[0703,0904,1 155]*XAD R YL YELLO W OR O RA.
Ein wichtiger Punkt beim Kauf des Geräts Goodman Mfg GMH95 (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Goodman Mfg GMH95 noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Goodman Mfg GMH95 - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Goodman Mfg GMH95 reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Goodman Mfg GMH95 erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Goodman Mfg GMH95 besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Goodman Mfg GMH95 verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Goodman Mfg GMH95. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Goodman Mfg GMH95 gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.