Series P 300 Triplex Ceramic Plunger Pump Operating Instructions/ Repair and Service Manual Contents: Installation Instructions: page 2 Pump Specifications: pages 3-7, 10 Exploded View: page 8 Parts L.
2 INSTALLATION INSTRUCTIONS 4. Use of a dampener is necessary to minimize pulsation at drive elements, plumbing, connections, and other system areas. The use of a dampener with Giant Industries, Inc. pumps is optional, although recommended by Giant Industries, Inc.
3 NOTES: In order to drive the pump from the side opposite the present shaft extension, simply remove the valve casing from the crankcase and rotate the pumps 180 degrees to the desired position. Be certain to rotate the seal case (item #20) as well, so that the weep holes are down at the six o'clock position.
4 Specifications Model P316 U.S. (Metric) 1450 RPM Ratings (Continuous) .................................... 4.4 GPM @ 3000 PSI ..... (16.7 LPM @ 200 bar) Ratings (Intermittent) .................................... 4.4 GPM @ 3500 PSI ..... (16.7 LPM @ 240 bar) 1750 RPM Ratings (Continuous) .
5 Specifications Model P317 NOTES: In order to drive the pump from the side opposite the present shaft extension, simply remove the valve casing from the crankcase and rotate the pumps 180 degrees to the desired position. Be certain to rotate the seal case (item #20) as well, so that the weep holes are down at the six o'clock position.
NPSHR (FT -HEAD) 50 68 86 104 122 140 158 176 194 212 230 0 F 69.0 66.0 62.3 59.0 56.8 52.5 49.2 46.0 43.0 39.3 36.0 33.0 30.0 26.2 1 7 3 0 R P M 6 . 2 2 G P M 1 4 2 0 R P M 5 1 G P M P318 NPSHR Chart P318 HORSEPOWER REQUIREMENTS RPM GPM 750 PSI 1000 PSI 1500 PSI 1750 PSI 2000 PSI 810 3.
P319 HORSEPOWER R EQUIREMENTS RPM GPM 1500 PSI 2000 PSI 2500 PSI 3000 PSI* 3000 4.2 4.3 5.8 7.2 8.7 3200 4.5 4.7 6.2 7.8 9.3 3450 4.8 5.0 6.6 8.3 9.9 7 Specifications Model P319 Consult the factory for special requirements that must be met if the pump is to operate beyond one or more of the limits specified above.
8 Exploded View - P300 Series.
9 P300 SERIES PAR TS LIST ITEM PART NO. DESCRIPTION QTY. 1 08326 Crankcase 1 2 06773 Dipstick Assembly 1 3 08410B Crankcase Cover, Short 1 3 08410-LG Crankcase Cover, Extended 1 3 A 07190 Oil Drain Pl.
P340 HORSEPOWER R EQUIREMENTS RPM GPM 1500 PSI 2000 PSI 2500 PSI 3000 PSI 3500 PSI 4000 PSI* 745 1.5 1.6 2.1 2.6 3.1 3.6 4.1 1025 2.0 2.1 2.8 3.4 4.1 4.8 5.5 1340 2.7 2.8 3.7 4.7 5.6 6.5 7.4 1450 2.9 3.0 4.0 5.0 6.0 7.0 8.0 1750 3.5 3.6 4.8 6.0 7.2 8.
11 Position Item# Description T or que Amount 3 B 08410/07190 Oil Drain Plug w/ Gasket 222 in.-lbs. 6 07188/1196 Screw 43 in.-lbs 1 0 7225 Screw with Lock W asher 85 in.-lbs. 1 6 C 08456 or 08450 T ension Screw , Plunger 220 in.-lbs. 3 4 08363 Hex Head Cap Screw , V alve Casing 222 in.
PUMP SYSTEM MALFUNCTION 12 PUM P SYST EM M A L FUNC TION S MALFUN CTION CAU SE REM EDY The Pressu re and/ or t he Deliver y Dro p s W orn pac k ing se als Re pl ac e pac k ing se als Brok en valve spr.
13 REPAIR INSTRUCTIONS - P300 SERIES NOTE: Always take time to lubricate all metal and nonmetal parts with a light film of oil before reassembly. This step will ensure proper fit, at the same time protecting the pump nonmetal parts (i.e., the elastomers) from cutting and scoring.
14 11. Inspect o-rings (#21 and 22) and replace as necessary. 9. Remove the pressure rings (#24) and grooved seals (#23) from the valve casing (#26). Inspect parts for wear and replace if necessary. For P318 only, the spacers (#23A) can now be removed.
15 Reassembly sequence of the P300 Series pump REPAIR INSTRUCTIONS - P300 SERIES 14. If the oil seals (#19) were removed, replace them with the primary seal lip (grooved side) towards the crankcase and the dust lip (tapered end) towards the valve casing (#26).
GIANT INDUSTRIES LIMITED WARRANTY Giant Industries, Inc. pumps and accessories are warranted by the manufacturer to be free from defects in workmanship and material as follows: 1. For portable pressure washers and self-serve car wash applications, the discharge manifolds will never fail, period.
Ein wichtiger Punkt beim Kauf des Geräts Giant P300 (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Giant P300 noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Giant P300 - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Giant P300 reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Giant P300 erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Giant P300 besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Giant P300 verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Giant P300. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Giant P300 gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.