Benutzeranleitung / Produktwartung pmcs 6.15 des Produzenten GE
Zur Seite of 72
GE MULTILIN TM PMCS 6.15 Read-This-Book-First Installation Guide DEH-211 GE Power Management Control System.
Notice The information cont ained in this docum ent is subject to change wit hout notice. GE m akes no warranty of any kind with regard to th is material, including, but not limited to, the implied warranties o f merchantability and fitness for a particular purpose.
GE MULTILIN TM PMCS 6.15 Read-This-Book-First Microsoft, Microsoft Excel and Microsoft PowerPoint are regist ered trademarks, and Windows 2000 is a trademark of Mi crosoft Corporation. Multilin 269+ Motor Management Relay® are register ed tradem arks of Multilin Inc.
.
(This Page is Left Blank Intentionally) CIMPLICITY PMCS Read-This-Book-First • i.
Back to Main Page Contents Introduction 6 Welcome .................................................................................................................................... 6 How to Use this Book .............................................
Organize Your Information ....................................................................................... 52 Configuration Procedure ........................................................................................... 54 EPM Device-Special Considerations 57 Introduction .
.
(This page left blank int entionally) CIMPLICITY PMCS Read-This-Book-First Introduction • 5.
Introduction Welcome Hello and welcom e to the POWER LEADER Power Managem ent Cont rol System for CIMPLICITY ® HMI. You are about to begin using your computer in an exciting new way—as a tool t o help y ou increase productivity while reducing downtime and energy costs.
About CIMPLICITY PMCS Version 6.15 CIMPLICITY PMCS Versi on 6.15 is the latest Power Management Control System in t he robust line of POWER LEADER power-managem ent products from GE Multilin. CIMPLICITY PMCS seamlessly integrates the comprehensive line of POWER LEADER devices, as well as many new Modbus RTU devices and systems.
• CIMPLICITY PMCS Interface Toolk it with tools to quickly create accurate, intelligent floor plans, one-line diagram s, and elevation views. • System Test Si mulator to design and test PMCS systems wi thout connection to real networks or devices.
(Thi s page left blank int entionally) CIMPLICITY PMCS Read-This-Book-First Introduction • 9.
Getting Started First Steps If you are already familiar with PMCS, simply review the system requirements and skip ahead to Chapter 3 . Getting started wit h PMCS is easy. This chapt er explains power m anagement and leads you through the steps to take pr ior to installing your PMCS software.
Communication network: A phy sical standard for wiring and interconnection of comm unicating devices. A com municati on network standard usually i ncludes specifications of voltages, m axim um cable-run lengt hs, shielding, term ination, and cable requireme nts.
NetDDE: A version of Dynamic Data Exchange (DDE) t hat allows comm unications between applicat ions running on di fferent PCs over network connections. NT Service: A designated piece of software wh ich runs in the background of Windows NT and can be set to automatical ly start when the machine is booted up.
System Requirements The following table shows the minim um and recom mended PC sy stem configuration for running PMC S Version 6.15. Note t hat regardless of configuration, the PC system must be Windo.
PMCS 6.15 Envelope definition 1) Physical System Size • 75 power managem ent devices (IEDs) (100 m ax), • 150 I/O points (through IEDs or PLCs ) • 64 ethernet serial com munications port s, • .
Where to Get Help The GE Industrial Systems Resolut ion Center is availa ble at 1-888-GE- RESOLV to answer your questions about installing or using PMCS. Please have your product serial number(s ) ready when calling. Also, technical notes are av ailable on the Internet at: http://www.
(This page left blank int entionally) 16 • Getting Started CIMPLICITY PMCS Read-This-Book-First.
Installing the Software Computer Preparation PMCS must be installed on a PC runni ng Windows 2000 SP4. This host PC must be dedicated to the PMCS sy stem. Perform ance and data integrity cannot be predicted unless the PC is configured solely for t he purpose of running PMCS.
When Installing On Windows 2003 Server The Following steps to b e executed before starting th e PMCS installation. This applies for all the licenses of PMCS ap plication. This is basically to av oid the problem caused by e-l icense wrapped PMCS applicati ons to open after installation.
Click on Apply and t hen click on Ok button. Afte r this restart the PC and then start the PMCS installation p rocess as mentioned in this d o cument. Installing CIMPLICITY If CIMPLICITY HMI was provided wi th your PMCS software, y ou must install it before proceeding.
Installing Additional Software Install any add itional software, such as Microso ft Excel, at this point in th e procedure. Follow the instruction procedures provi ded by the manufact urer.
Select the appropr iate n etwork adapter from the list and click Have Disk… . Follow the instructions provi ded on the screen to complet e the network card installation. For PMCS systems using one or more GE Multilin RS232 to RS485 converters (or equivalent), no additi onal drivers are required.
Local Area Network (LAN) Interfaces PMCS supports multiple View Nodes th rough NetDDE links over a local area network. Thus, in addition to the PMCS network interface, the Host PC may also have a LAN interface.
Installing Additional Software Install any add itional software, such as Microsoft Excel or COMTRADE file browsers for analyzing waveform files, at t his point in the procedure.
your eLicense Option screen (see below). This screen allows you to either trial or fully license your PMCS software. 720 Hours (30-Day) Trial You have the option to Trial PMCS for 720 Hours (30 days) through the 720 Hours Trial selection o n this screen.
Selecting the Web License option from the License Option bri ngs you to the Web License Screen. This screen requires you to enter your eLicense Order ID.
2. When the system on which PMCS is being in stalled is not having any .Net Framework installed on it. The PMCS 6.15 insta llation will go ahead by installing .Net Framework 1. 1.4322. This is applicable for all licenses. 3. When the on which PMCS is being installed is not having IIS installed.
3. In the Run dialog box, enter X:s etup (where X is the appropriate C D-ROM drive designation). 4. The below screen is observed when .N et is not installed on the machine where PMCS is being installed.
28 • Installing the Softw are CIMPLICITY PMCS Read-This-Book-First.
5. Click on I agree and cl ick on Install button. It will now install .Net Framework on the machine where PMCS installation is started. After the .Net installat ion is comple ted below message box i s displayed.
6. GE PMCS 6.15 welcom e screen a ppears. When you select the Next button in the Welcome screen, the PMCS license agreement screen is shown. Please take a m oment to read over the license agreement, and then click Y es .
7. At the User Information screen shown below, enter your name, your company name, and the serial number for the PMCS com ponent you are installing. Serial numbers for PM CS components are locat ed on the PMCS CD-ROM jewel case. If you make an error in the serial number, the installation routin e will prompt you for a correct PMCS serial number.
When you select the Next button in the User Inform ation screen, a registrati on confirmati on screen prompts you to verify your entries. Ensure t hat you have made no m istakes in the User Inform ation fields, and then continue. 8. If IIS is not installed in the Machin e for the licenses it is required.
At the Choose Destination Location di alog, specify a drive on which to install PMCS. Default is “C”. Click Next to continue. CIMPLICITY PMCS Read-This-Book-First Installing the Softw are • 33.
9. At the Setup Type screen, select Custom in stallation, standard PM CS installati on, or PMCS with EPM 7700 Com ponents. PMC S installat ion is recommended and will install all com ponents for the PMCS catalog num ber you entered in the User Inform ation screen.
10. If you did not select “PMCS with EPM 7700 C omponents” in the Setup Type dialog box (Step 9), skip this step and proceed to Step 13. If you are installing the EPM 7700 Components, select whether this is to be a Primary node installat ion or Secondary node installati on.
11. If you did not select “PMCS with EPM 7700 C omponents” in the Setup Type dialog box (Step 9) or if y ou selected “Prima ry Node Installation” i n Step 10, skip this step and proceed to Step 13.
12. If you did not select “PMCS with EPM 7700 C omponents” in the Setup Type dialog box (Step 9), or if you selected “Pri mary Node Installati on” in Step 10, skip this step and proceed to Step 13.
13. Select the Prog ram Folder for PMCS installation. It is recommended that the default Program Fol der be chosen. Click Next to continue. 38 • Installing the Softw are CIMPLICITY PMCS Read-This-Bo.
14. If you chose the “PMCS” installation, y ou may be presented wit h one DDE Server selections depending upon the PMC S catalog number you entered i n the User Information screen. Select this DDE co mmunicati on server if you wish to use it on yo ur system.
40 • Installing the Softw are CIMPLICITY PMCS Read-This-Book-First.
16. The Selected Components screen offers you the opportunity to verify the installation set tings before any files are copi ed to your hard dri ve. Confirm that the installation setting s are correct, then click Next . The installation program copies the appropria te files to your hard dri ve.
17. After completing th e selected PMCS installation, the installation pr ogram checks the host PC for an older version of the POWER LEADER Modbus Monitor Proxy software. If the installer locates th e Proxy software, it prompts you t o update the Proxy to the PCM S 6.
If No is selected and clicked on finish it will prompt the below m essage box and will again redirect to the above dialog aski ng to restart. So select Yes to restart at this dialog.
. After PMCS IIS – Setting up PMCS Server For any PMCS remote viewer system to connect to the PMCS server, the prerequisite is to have IIS installed on the PC first then .
In order to unlicense your software to use your eLicense Order ID for anot her computer – you m ust have an internet connection. To retri eve your li cense for use on another PMCS installation, sim ply right cl ick on any PMCS executabl e on your desktop and select unlicense.
NOTE: The Uninstaller may not delete some files such as error logs, system logs, and configuration records, whi ch ar e created after the PMCS installation is complete. Since these files are no t part of th e initial installation, they will not be removed by the Uninst aller, and must be del eted manual ly.
Reinstallation Steps Follow the procedu re below to reinstall your PMCS so ftware. 1. If your system includes the PM CS Interface Toolkit, uninstall the CIMPLICITY Wizards from any third-party HMI tool s. 2. Close any open applicati ons. 3. Insert the PMCS Version 6.
Upgrading from previous versions to PMCS 6.15 PMCS 6.15 provides an easy-to-use, autom atic upgrade path from previ ous versions of PMCS. The software instal ler examines y our hard drive and, if it locates any previous version of PM CS, it makes decisions on upgrading each component.
WARNING : Event Logger users only: Upgrading your EventServer or Eventlogger application will result in the loss of all device configurations and annunciator panel item s. Make a list of these it ems so that t hey may be reconstructed in the new applicati on.
Working with Cimplicity Viewer Node How to view the screens on a viewer node To configure the project on a Cimplici ty viewer node, running on a HMI server, follow the directions below. 1) Install Cimplicity HMI 6.1 SP5 on one machine with HMI Server option on a Windows 2000 SP4 machine.
CIMPLICITY PMCS Read-This-Book-First • 51.
Configuring the Software To get the most out of y our new PMCS system , follow the directions bel ow to configure your system . Organize Your Information Host PC You need the following inform ation to properly confi gure the PMCS soft ware for the Host PC.
Ethernet Gateway IP Address COM port Modbus RTU Address Device Type Device (Topic) Name 10.47.28.201 1 2 EPM 9650Q E9650Q 10.47.28.201 1 12 E3720 Main_Meter 10.47.28.201 1 33 PLEPM Mfg_Meter 10.47.28.201 1 61 PLEPM Plating_Meter 10.47.28.201 2 12 UR L90 UR 10.
Configuration Procedure Follow the procedure below to efficientl y configure your system and minim ize your time to startup. Host PC Configuration 1. Configure the DDE Server . Your Host PC will likely have several versions of the DDE Server installed (RS485-Modbus, TCP/IP M odbus, TCP/IP Encapsulated Modbus and Ethernet-TC P/IP).
EPM Software Components Configuration The EPM 7700, EPM 7600 and EPM 7500 requi res several separate software components which are i nstalled during the PMC S setup. This section provides a brief overview of the steps required to configure these component s; the following section describes the EPM software components in greater det ail.
(This page left blank int entionally) 56 • Configuring the Software CIMPLI CITY PMCS Read-This-Book-First.
EPM Device- Special Considerations Introduction The GE EPM 7700, EPM 7600 and EPM 7500 devices add new level of power management capabilities to PMCS. These EPM devices also require some special configuration whic h is not necessary for other PM CS-compatibl e devices.
EPM Software Components There are four major com ponents of the EPM software. The Network Builder, ION Designer, Communications Serv er, and ION_LINK DDE Server each interact to support t he EPM 7700, EPM 7600 and EPM 7500 Meters.
Workstation Configuration Guidelines If you are using the EPM 7700, EPM 7600 or EPM 7500 Meters in your PMCS network, the fo llowing guide lines in this section must be adhered to before continuing with the EPM configuration.
Configuring the EPM Device Network The PMCS installation ro utine described earlier in th is manual creates initial workstation and software node entrie s in the EPM 7700 network configuration file.
Building the Power-Monitoring Network in NetBuilder When Network Builder is running, you can begin configuring your EPM system by adding a site to the workstation, then adding devices to the site. For l arger systems multiple sites are added; one fo r each network of devices m onitored.
Adding Software Nodes Software nodes identify the various soft ware components in the network. Stationless Secondary nodes, alt hough they are physical ly separate com puters, do not run a Comm unications Server and are therefore not considered Workstations by Network Builder.
Adding an Ethernet Site An Ethernet site defines the network connection between the devices and the Workstation(s). You add Ethernet sites to Workstations, then add devices to the sites. To add a new Ethernet site , ri ght-click a Workstation name and choose “Insert: Ethernet site” from the pop-up menu – at tach it to the current Workstation.
Set the following communications parameters for the site. • Enter the Transmit delay setting (in milliseconds). This setting determines the level of traffic on th e network. If the PMCS system is the sole user of the n etwork, set this value to 5 (or less) to maximize performance.
Adding Devices (Meters) To add a meter, ri ght-click on the Ethernet si te you want to add the met er to, and select Insert Device… from the pop-up menu. The Add Ethernet Device dialog box appears (shown below). Enter the following info rmation: • Choose the mete r type from the Ty pe list (Power Measurem ent 7700 ION).
(This page left blank int entionally) 66 • EPM Device-Special Considerations CIMPLICITY PMCS Read-This-Book-First.
Index A alarm, 4 D DDE Server, 54 E Ethernet, 4, 8, 18, 19, 48, 50 event, 4 F Fanuc, 4 First Steps, 7 I Interface Toolkit, 5, 8, 43, 50 M minimum syst e m requirements, 3 Modbus Monitor Proxy, 39 Modb.
GE MULTILIN General Electric Company 215 Anderson Avenue, Markham ON, L6E 1B3, CANA DA USA & Canada: 1- 800-547-8629 Global: (905) 294-6222 Fax: (905) 201-2098 Email: multilin.
Ein wichtiger Punkt beim Kauf des Geräts GE pmcs 6.15 (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie GE pmcs 6.15 noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für GE pmcs 6.15 - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von GE pmcs 6.15 reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über GE pmcs 6.15 erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon GE pmcs 6.15 besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von GE pmcs 6.15 verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit GE pmcs 6.15. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei GE pmcs 6.15 gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.