NetworX ™ Series NX-8V2 Control Panel Inst allation and S t artup.
© 2005 GE Security All rights reserved. These instructions do not purport to cover all details or variati ons in e quipment nor to provi de every possi ble contingency to be met during installation, op eration, and maint enanc e.
NX-8V2 Control 3 Table of Contents I. GENERAL DESC RIPTION............................................................................................................ ..................................................... 4 II. ORDERING IN FORMATION ..
4 NX-8V2 Control I. GENERAL DESCRIPTION The NetworX N X-8V2 represents a ne w approach to secur ity systems design. Dra wing on our experience in th e world market as the largest exporter of USA manufactured c ontrols, we have dev eloped the most flexible, durable, and us er-friendly control ever see n in our industry.
NX-8V2 Control 5 IV. NX-8V2 WIRING DIAGRAM.
6 NX-8V2 Control V. TERMINAL DESCRIPTIONS TERMINAL DESCRIPTION R1 House Telephone Ri ng (Grey). R Telephone Ring (Red). T Telephone Tip (Green). T1 House Telephone T ip (Brown). EARTH Earth Ground. Connect to a cold water pipe or a 6 to 10 foo t driven rod.
NX-8V2 Control 7 VI. PROGRAMMING THE LED KEYPADS KEYPAD ADDRESS AND PARTITION This section describes how to program the ad dress and partition of each keypad as well as the options that are ava ilable. The a ddr ess of the keypad is important because this is how the panel superv ises the keypads.
8 NX-8V2 Control ASSIGNING AUTHORITY LEVEL: • Enter [ r ]-[ 6 ]-[ master code ]. The "Ready" LED will flash. • Enter the 2 digit user number. The "Ready" LED will ill uminate steady and the "Instant" L ED will flash. • Refer to the chart below for the description of each LED.
NX-8V2 Control 9 the [MEDICAL] key. To revi ew the data in a loc ation, repeat the abov e procedure, pr essing [ r ] without any numeric data entry. Each time [ r ] is pressed, the programming data of the next segment will be dis played for revie w.
10 NX-8V2 Control PROGRAMMING EXAMPLE Zone 1 LED = 1 Zone 4 LED = 8 } Data = 9 To change data in a segment, enter the data followed by [ ] Enters the previous programming “location” . Zone 2 LED = 2 Zone 7 LED = 64 } Data = 66 Returns to the “location” j ust programmed.
NX-8V2 Control 11 IX. LOADING FACTORY DEFAULTS To load the f actory defaults, enter the program mode us ing the proced ure on page 8, then type [ 9 ]-[ 1 ]-[ 0 ]-[ # ]. The keypad will be ep 3 times indicating that the loading is in pr ogress. The loadi ng takes about 6 seconds.
12 NX-8V2 Control L 3 DI AL ATTEMPTS/BA C KUP CONT ROL FOR PHONE 1 2 ........... numerical Segment 1- Dial atte mpts: Location 3, Segm ent 1 is used to enter the number of di al attempts (1 to 15 Attempts) the communicator will make to Phone 1 befor e ending the notific ation process.
NX-8V2 Control 13 L 8 COMMUNICATOR FORMAT FO R PHONE 2 1 ............. numerical Location 8 cont ains the communic ator format used to trans mit to t he receiver connected to P hone 2.
14 NX-8V2 Control 13 ACCOUNT CODE FOR PHONE 3 6 ............ numerical The account code s ent when Phon e 3 is diale d is programmed in location 13. Pro gram a A 10" in the segment immediately after the last digit of the account code. If the account code is 6 digits lon g, program all 6 segments.
NX-8V2 Control 15 18 CUSTOM COMMUNICATOR FORM AT (See loc 2, 8, &14) Segment 1: Segment 2: 1 = On for 1800hz transmit; Off for 1900 hz. 2 = On for 2300 hz handshake; Off for 1400hz. 3 = On for cksum parit y; Off for double round parity. 4 = On for 2 digit event code; Off for 1 digit event code.
16 NX-8V2 Control Segment 2: 1 = On enab les the LED Extinguish feature. 2 = On enab les the Require Code for B ypassing feature. 3 = On enab les the Zone Bypassed Soun der Alert feature. 4 = On enab les the AC Power/Low Battery Sounder Alert feature.
NX-8V2 Control 17 DA T A DESCRIPTION OF DEFAULT ZONE TYPES 11 KEYSWITCH ZONE - This zone type will arm and d isarm the partition or parti tions of the control pane l that it resides in each time the zone is shorted. Keys witch arming will report as user #99.
18 NX-8V2 Control Segments 1 - 8: 1 = Partition 1 3 = Partition 3 5 = Partition 5 7 = Partition 7 2 = Partition 2 4 = Partition 4 6 = Partition 6 8 = Partition 8 L 27 ZONES 9-16 ZONE TYPE 8 ............ numerical Location 27 contains the Zone Type for zon es 9 -16.
NX-8V2 Control 19 36 PARTITION SELECT, ZON ES 41-48 8 ............. f eature select Location 36 is used to select the partition or partitions that zones 41-48 reside in. A zone ma y reside in any combination of t he 8 partitions. If a burglary zone resides in more than 1 partition it w ill only be active when all partitions are armed.
20 NX-8V2 Control Segment 6: 1 = Enab le 2 wire smoke. 2 = Reserv ed. 3 = Enab le for Zone Activity in Hours (not Days) 4 = Enab le Daylight Savings T ime (DST) 5 = Reserv ed 6 = On to disabl e Clean .
NX-8V2 Control 21 L 42 GO TO PROG RAM CODE 6 ............. numerical Location 42 contains th e "Go To Program Code". T his location cont ains e ither a 4 or 6-digit code. If the 6- digit code option i s enabled in Location 41, THIS CO DE MUST CONTAIN SIX (6) DIGITS.
22 NX-8V2 Control 48 AUXILIARY OUTPUT 2, EVENT & TIME 2 ............ numerical Segment 1: Use Table XIII-1 to select the event t hat will activate Auxiliary Output 2. Segment 2: Program the timing from 0-255 (minutes or seconds, dep ending on data programm ed in Segment 2, Location 46).
NX-8V2 Control 23 54 DAYS OF WEEK EA CH P ARTIT ION IS OPEN 8 ............. feature select Location 54 selects which days of the week each partition is ope n. On these days, A arm only after close window @ codes will be able t o arm and disarm during ope n window.
SLOW COMMUNICATOR FORMAT CODES 24 NX-8V2 Control 61 SENSOR MISSING COMMUNI CATOR CODE 8 ............ numerical Location 61 contains the event code for a zone "Se nsor Mi ssing" for a 4+2 format.
SLOW COMMUNICATOR FORMAT CODES NX-8V2 Control 25 77 OPENING COMMUNICATO R CODE 8 ............. numerical Location 77 contains the digit of a 4+2 fo rmat if the "Opening Reporting " is enabled.
26 NX-8V2 Control 92 ACCOUNT CODE FOR PARTITION 3 6 ............ numerical The account code s ent when partition 3 is rep orted is programmed in locatio n 92. If location 92 is left unprogra mmed (all A 10") then the account code corre sponding to the Phone number diale d will be used.
NX-8V2 Control 27 102 PARTITION 6 FEATURE & REPORT ING SELECTIONS 5 ............. feature select Location 102 is use d to enable certain fe atures that c an be accessed or are visible to th e user from the keypa d of the system. In addition, certain communicator reports are enabled in this loc ation.
28 NX-8V2 Control LOCATIONS 110-169 ARE USED TO CHANGE THE ZONE TYPES (C onfigurations) AS LISTED IN THE TABLE ON PAGE 16. THESE LOCATIONS ARE CONSIDERED ADVANCED PROGRA MMING AND SHOULD ONLY BE CHANGED WITH A THOROUGH UNDERSTANDING OF THE OPERATION OF EA C H BIT.
NX-8V2 Control 29 116 ZONE TYPE 4 ALARM EVENT CODE 1 ............. numerical Location 116 contains the eve nt code sent for a Contact ID or SIA report. The desired event code shoul d be chosen from the list on page 50. The zone ID will be that zone that is in alarm.
30 NX-8V2 Control 136 ZONE TYPE 14 ALARM EVENT CODE 1 ............ numerical Location 136 contains the eve nt code sent for a Contact ID or SIA report. The desired event code shoul d be chosen from the list on page 50. The zone ID will be that zone that is in alarm.
NX-8V2 Control 31 156 ZONE TYPE 24 ALARM EVENT CODE 1 ............. numerical Location 156 contains the eve nt code sent for a Contact ID or SIA report. The desired event code shoul d be chosen from the list on page 50. The zone ID will be that zone that is in alarm.
32 NX-8V2 Control XIV. PROGRAMMING WORKSHEETS (Factory defaults for segments are in bold italics text and "Quick Start" locations are identified with the L symbol.
NX-8V2 Control 33 LOC PG DESCRIPTION DEFAULT PROGRAM DA T A 17 14 PHONE 3, SELECT ING WHICH PARTITIONS REPORT TO PHONE 3 Segment 1 (Circle Numbers To Program) 1 = Partition 1 2 = Partition 2 3 = Parti.
34 NX-8V2 Control LOC PG DESCRIPTION DEFAULT PROGRAM DA T A 26 17 ZONES 1-8, PARTITION SELECTION (Segment 1= Zone 1 thru Segment 8=Zone 8) Segments 1 2 3 4 5 6 7 8 Partition 1 Partition 2 Partition 3 .
NX-8V2 Control 35 LOC PG DESCRIPTION DEFAULT PROGRAM DA T A L 37 19 SIREN AND SYST EM SUPERVISION Segment 1 (Circle Numbers To Program) 1 = Siren sounds for telephone line cut while arme d. 2 = Siren sounds for telephone line cut while disarme d. 3 = Siren blast at arming.
36 NX-8V2 Control LOC PG DESCRIPTION DEFAULT PROGRAM DA T A L 39 20 KEYPAD SOUNDER Segment 1 (Circle numbers to program) 1 = Keypad sounds for Telephone Line Cut when in the Armed state. 2 = Keypad sounds for Telephone Line Cut when in the Disarmed state.
NX-8V2 Control 37 LOC PG DESCRIPTION DEFAULT PROGRAM DA T A 46 21 AUXILIARY OUTPUTS 1-4 SPECIAL T IMING Segments 1 2 3 4 1 = Aux output timed in minutes. 2 = Aux output to latch. 3 = Aux output to stop timin g upon use r code entry. 4 = Aux output to activate only bet ween closing & openin g time.
38 NX-8V2 Control COMMUNICATOR CODES FOR SLOW SPEED FORMATS ONLY The digit programmed in each of the follow ing locations will be sent as the upper HEX di git in place of the alarm event code. The zone ID or user ID w ill always be reported as th e lower HEX dig it (1-F).
NX-8V2 Control 39 LOC PG DESCRIPTION DEFAULT PROGRAMMING DATA 64 24 AUXILIARY 2 0-0 _ _ 65 24 KEYPAD PANIC 0-0 _ _ 66 24 KEYPAD MULTIPLE CODE E NTRY TAMPER 0-0 _ _ 67 24 BOX TAMPER / BOX TAMPER RESTOR.
40 NX-8V2 Control LOC PG DESCRIPTION DEFAULT PROGRAMMING DATA 91 25 PARTITION 2 ENTRY/EXIT TIMERS Segment 1: Entry Time 1 0 _ Segment 2: Exit Time 1 0 _ Segment 3: Entry Time 2 0 _ Segment 4: Exit Tim.
NX-8V2 Control 41 LOC PG DESCRIPTION DEFAULT PROGRAMMING DATA 99 26 PARTITION 5, FEATURE AND REPORTING SELECTION Segment 1 1 = Quick Arm 2 = Re-Exit 3 = Auto Bypass 4 = Silent Panic 5 = Audible Panic .
42 NX-8V2 Control LOC PG DESCRIPTION DEFAULT PROGRAMMING DATA 105 27 Segment 2 1 = LED extinguish enable 2 = Require user code for bypassing zones 3 = Bypass soun der alert 4 = AC power/low battery so.
NX-8V2 Control 43 LOC PG DESCRIPTION DEFAULT PROGRAMMING DATA 111 28 Segment 3 1 = Fast Loop Response. 2 = Double End of Line Tamper zone. 3 = Trouble zone (Day zone). 4 = Cross Zone. 5 = Dialer Delay zone. 6 = Swinger zone. 7 = Restore reporting. 8 = Listen-In.
44 NX-8V2 Control LOC DESCRIPTION DEFAULT PROGRA MMI NG DATA 156 ZONE TYPE 24 ALARM EVENT CODE 22 __ 157 ZONE TYPE 24 CHARACTERISTIC SELECT 1-13- 378 __ __ __ __ __ 158 ZONE TYPE 25 ALARM EVENT CODE 1.
NX-8V2 Control 45 ZONE WORKSHEET 1 25 2 26 3 27 4 28 5 29 6 30 7 31 8 32 9 33 10 34 11 35 12 36 13 37 14 38 15 39 16 40 17 41 18 42 19 43 20 44 21 45 22 46 23 47 24 48.
46 NX-8V2 Control XV. GLOSSARY Abo rt If enabled, the NX-8V2 will wait the pro grammed number of s econds in location 40 prior to send ing an alarm. Du ring th is delay t ime, the “Cancel” LED will flash. T o abort the report, type in a code and pr ess the Cancel key.
NX-8V2 Control 47 Dual / Split / Multiple Reports The NX-8V2 can send commu nication reports to three different phon e numbers for dual, split or multiple reports selecta ble by ev ent or partition.
48 NX-8V2 Control Keyswitch Arm/Disarm Any zone on the NX-8V 2 can be programm ed as a keys witch zone. If this is done, a mom entary short on this zone will arm/disarm the control.
NX-8V2 Control 49 Tone Sniff Ans w ering Machine Defeat If enabled, only one call is required to defeat the ans wering machine. To use this feature you must have a Hayes 120 0 Smart Mod em.
50 NX-8V2 Control XVI. APPENDIX 1 REPORTING FIXED CODES IN C ONTACT ID AN D SIA The table below lists the event codes sent for the follo wing reports (if enabled) when using CONTACT ID or SIA formats. REPORT CONTACT ID SIA AC FAIL (devic e number) ...
NX-8V2 Control 51 XVII. APPENDIX 2 REPORTING ZONE C ODES IN SIA OR C ONTACT ID The NX-8V2 has the ability to report SIA level 1 transmission s to eithe r or both phon e numbers. Each report i n SIA consists o f an Event Code and a Zone or Us er ID. The Zone ID will be the zon e number that is in alarm.
52 NX-8V2 Control XVIII. APPENDIX 3 EXPANDER NUMBERS FOR REPORTING EXPANDER TROUBLE The tables belo w list the device numbers that will be reported for trouble c onditions. Device Device # reported NX-8V2 Control Panel 0 See page 50 for possible repo rt codes.
NX-8V2 Control 53 XIX. APPENDIX 4 USER ID OR ZONE ID HEX DIGIT FOR 4+2 FORMA TS The following appe ndix applies only to slow formats (locations 56 - 83 lower digit). The digit programmed in the locations will be sent as the upper HE X digit in place of t he alarm eve nt code.
54 NX-8V2 Control XX. LOCAL TELEPHONE COMPANY INTERFACE INFORMATION TELEPHONE CONNECTION REQUIREMENTS Except for telephone compan y provided ring ers, all connections to the tel ephone net work shall .
NX-8V2 Control 55 XXII. NOTICES (Applies to products which have the CE mark attached) Declaration Of Conformity Manufacturer’s Name: Caddx Controls Manufacturer’s Address: 1420 North Main Street G.
56 NX-8V2 Control XXIII. UNDERWRITERS LABO RATORIES INFORMATION The NetworX NX- 8V2 holds the follo wing listings from Under writers Laboratories (US and Canadian): UL294 Access Control System Units U.
NX-8V2 Control 57 MINIMUM SY STEM CONFIGU RATI ONS FOR UL INSTALLATIONS (Residential Fire, Residential Burgl ary, Commercial Burglary) • The NetworX NX- 8V2 panel is necessary to initiat e Residential and C ommercial installations. • At least one compatible keypad is nee ded for all applications .
XXIV. ANSI / SIA CP-01 REQUIREMENTS To meet SIA CP-01 requirem ents – • Minimum System Require ments: 1 control pa nel; 2 keypads (or 1 ke ypad per partition for multi-partitione d systems) • Remote arming shall N OT be enabled in SI A classified installations.
SYSTEM NOTES.
XXV. SPECIFICATIONS OPERATING POWER 16.5 VAC 4 0, or 50 VA Transformer AUXILIARY POWER w/25 VA Transformer 12 VDC Regulated 500 mA w/40 or 50 VA Transformer 12 VDC Regulated 1 AMP w/NX-320E Power Supp.
Ein wichtiger Punkt beim Kauf des Geräts GE NX-8V2 (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie GE NX-8V2 noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für GE NX-8V2 - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von GE NX-8V2 reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über GE NX-8V2 erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon GE NX-8V2 besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von GE NX-8V2 verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit GE NX-8V2. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei GE NX-8V2 gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.