Benutzeranleitung / Produktwartung FGB-M05 des Produzenten GE
Zur Seite of 52
MANU AL Gra viMaster -FGB-M05 (S) Gra vimetric Blender Serial No. ................... ISO 08.01.02.064.GB 986731 Rev . May 2001.
Rev . May 2001 GraviMaster -FGB-M05 (S) Page 1 Gravimetric Blender 1.0 INTR ODUCTION 2.0 CONTR OLS 2.1 Blender startup 2.2 Blender status 2.3 Machine-mode 2.4 Production-modes 2.5 Mixer -mode 2.6 Dispense modes 2.7 Batch handling 2.7.1 Production control 2.
Rev . May 2001 GraviMaster -FGB-M05 (S) Page 2 Gravimetric Blender 3.7 Settings of the user-interf ace 3.7.1 Change the rights of an operator 3.7.2 Change entrycode 3.7.3 Change date and time 3.7.4 Re vision code of the system 3.8 Menu hierarchy 4.0 INST ALLA TION 4.
Rev . May 2001 GraviMaster -FGB-M05 (S) Page 3 Gravimetric Blender 1.0 INTR ODUCTION GRA VIMETRIC FEEDING An ef fi cient materials blending system is an essential feature of the modern plastics processing industry . Dosing each component on the basis of weight shows distinct adv anta ges ov er traditional volumetric systems.
Rev . May 2001 GraviMaster -FGB-M05 (S) Page 4 Gravimetric Blender RELIABLE PR OCESS CONTR OL The FGB control system incorporates the latest in computer and micro processor technology for total automation of recipe entry and stora ge, in v entory control and process monitoring.
Rev . May 2001 GraviMaster -FGB-M05 (S) Page 5 Gravimetric Blender 2.0 CONTR OLS When all components are av ailable the dispense of a batch starts. The cycle be gins with closing the weigh-pan. Then each of the requested components is dispensed and weighed in the weigh-pan.
Rev . May 2001 GraviMaster -FGB-M05 (S) Page 6 Gravimetric Blender Paus e When the pause-command is giv en for a temporary stop the blender will stop after the cycle is complete. Stop requested The blender is operating but has recei ved a stop-command.
Rev . May 2001 GraviMaster -FGB-M05 (S) Page 7 Gravimetric Blender 2.4 Production-modes The production-mode of the blender indicates ho w the production will stop in automatic- mode. This parameter can be changed using the menu (F1) ‘ contr oller / public parameters ’ .
Rev . May 2001 GraviMaster -FGB-M05 (S) Page 8 Gravimetric Blender 2.6 Dispense modes The blender has two ways of dispensing: gra vimetric and v olumetric. One mode can be selected or a combination of both. This can be de fi ned choosing menu (F1) ‘ contr oller / public parameter s ’ .
Rev . May 2001 GraviMaster -FGB-M05 (S) Page 9 Gravimetric Blender 2.7.2 Recipe to weight calculation After a start-command the controller will calculate the requested weights of all components of the selected recipe. A recipe can be de fi ned in two ways: ‘ Standard ’ and ‘ Percentage ’ .
Rev . May 2001 GraviMaster -FGB-M05 (S) Page 10 Gravimetric Blender 2.7.2.2 Method Per centage The dif ferent component are de fi ned as follows: Regrind : Percentage of the batch weight Natural : Percentage of the batch weight Additi ve : Percentage of the batch weight T otal sum must be 100%.
Rev . May 2001 GraviMaster -FGB-M05 (S) Page 11 Gravimetric Blender 2.7.4 Additive to r egrind It is possible to dispense more additi ve in relation to the amount of re grind. Choose for this de fi nition menu (F1) ‘ contr oller / public par ameters ’ .
Rev . May 2001 GraviMaster -FGB-M05 (S) Page 12 Gravimetric Blender 2.7.5.2 Stock Silo Control A regrind silo can ha ve (optional) three sensors to detect high- lo w- and middle. If the controller has these sensors, ‘ Stock-Silo ’ regrind control can be acti v ated, choosing menu (F1) ‘ contr oller / pr otected parameters ’ .
Rev . May 2001 GraviMaster -FGB-M05 (S) Page 13 Gravimetric Blender 2.7.6 Dispensing Dispensing of the dif ferent components will start after the calculation of the related weights. The components are dispensed in the order as de fi ned in the recipe (gravimetric only).
Rev . May 2001 GraviMaster -FGB-M05 (S) Page 14 Gravimetric Blender Dispense not correct (too much) T o much material has been dispensed so there is nothing the controller can do. Of course the relations within the recipe will corrected by re-calculations.
Rev . May 2001 GraviMaster -FGB-M05 (S) Page 15 Gravimetric Blender 2.8 Datalogging Some production data is stored. This is sho wn at the user interf ace and can also be printed.
Rev . May 2001 GraviMaster -FGB-M05 (S) Page 16 Gravimetric Blender 2.9 EQ-Net Certifi cate.
Rev . May 2001 GraviMaster -FGB-M05 (S) Page 17 Gravimetric Blender 2.10 ISO Certi fi cat.
Rev . May 2001 GraviMaster -FGB-M05 (S) Page 18 Gravimetric Blender 3.0 USER INTERF A CE 3.1 Operator -interface 3.1.1 K eyboard Description: F1 Open main menu. All other sub-menu ’ s can be selected F2 Open option menu. The contents is dependent of the actual screen.
Rev . May 2001 GraviMaster -FGB-M05 (S) Page 19 Gravimetric Blender Besides the function ke y there are some special keys: DIRECT MA CHINE-CONTROL KEYS K ey Description # or F4 Select FGB ST AR T Star.
Rev . May 2001 GraviMaster -FGB-M05 (S) Page 20 Gravimetric Blender 3.1.2 User contr ol The user-interf ace consists of se veral screens which can be selected by a menu. A screen consists of objects only one object in a screen is acti ve (selected). By using the ↓ en ↑ arro w keys the actual selected object can be changed.
Rev . May 2001 GraviMaster -FGB-M05 (S) Page 21 Gravimetric Blender 3.2.1 Change components There is a components list av ailable in the controller . The list can be used by the operator to de fi ne recipes. The components list stores the name and type of a component and is maximised to 100 components.
Rev . May 2001 GraviMaster -FGB-M05 (S) Page 22 Gravimetric Blender In the screen it is possible to select a component with the arrow k eys. After a component has been acti vated by <ENTER> the name and type can be changed. If the fi eld type has been acti vated an option list will appear .
Rev . May 2001 GraviMaster -FGB-M05 (S) Page 23 Gravimetric Blender If the character W has been found the ? ke y is pressed. Name T ype <W> ? [N A TURAL] Step: Repeat the same procedure for the character H, I, T and E. When the whole name is gi ven press <ENTER>.
Rev . May 2001 GraviMaster -FGB-M05 (S) Page 24 Gravimetric Blender 3.2.2 Add/change recipes The terminal has the capacity for 340 recipes. This space is di vided into 4 spices so e very connected FGB can contain 85 recipes. If the menu item (F1) ‘ r ecipes / edit r ecipes ’ is chosen a list with recipes will be displayed.
Rev . May 2001 GraviMaster -FGB-M05 (S) Page 25 Gravimetric Blender FIELD OF A RECIPE Fields Description Number Unique recipe number Name Recipe name Colour Character fi eld for the colour-name Batch T otal batchweight Interpretation Recipe calculation Component Link hopper to component The screen can be left by pressing the <ESC>-ke y .
Rev . May 2001 GraviMaster -FGB-M05 (S) Page 26 Gravimetric Blender Actions: Step: Menu (F1) ‘ r ecipes ’ <ENTER> Step: ‘ edit r ecipes ’ <ENTER> Name Nr . Colour Step: Press the <INS> ke y (INS = insert) Number: [1] Name: ? ? Colour: [ ] Batch: [ 2.
Rev . May 2001 GraviMaster -FGB-M05 (S) Page 27 Gravimetric Blender Step: Press the arrow-k ey <↓> once Interpretation: < ST ANDARD> Step: When the interpretation must be changed into PERCENT A GE press the <ENTER> ke y . Now select PERCENT A GE with the arrow k eys and con fi rm with <ENTER>.
Rev . May 2001 GraviMaster -FGB-M05 (S) Page 28 Gravimetric Blender Step: Use the arrow-k eys <↓> to select a component and press <ENTER>. Use the arro w-key <?> to select Quantity . Enter the quantity and press <ENTER>. Use the arro w-key <→> to select Alarmtype and press <ENTER>.
Rev . May 2001 GraviMaster -FGB-M05 (S) Page 29 Gravimetric Blender 3.3 Timely inf ormation It is possible to get an ov er vie w of one of the connected controllers. Therefore three screens are av ailable on the terminal: production-screen, material usage-screen and input/output- screen.
Rev . May 2001 GraviMaster -FGB-M05 (S) Page 30 Gravimetric Blender OPERA TING A UT O[ ] [ ] [ ] ST A TUS:[0] FGB#00: (No name) ST A TUS OPERA TING MODE: A UT OMA TIC PR ODUCTION ST A TUS] Production .
Rev . May 2001 GraviMaster -FGB-M05 (S) Page 31 Gravimetric Blender 3.3.3 Input & Output monitor The input & Output screen menu (F1) ‘ contr oller / digital I/O monitor ’ displays all digital input and output lines. Every object in the screen can be selected by using the arro w-ke ys.
Rev . May 2001 GraviMaster -FGB-M05 (S) Page 32 Gravimetric Blender 3.4.3 Hard ware-r eactiontime The adjustment of the number of pulses is very important for the autopulse system of the FGB-M05. When dosing less than 8 gram of material, the GraviMaster will switch o ver to the autopulse system.
Rev . May 2001 GraviMaster -FGB-M05 (S) Page 33 Gravimetric Blender PUBLIC P ARAMETERS Parameter Description Init AlarmReport Indicates if alarm-reports must be printed. No *) ProductionReport Indicates if production-reports must be printed. No *) If so the parameter interv al-time must be giv en also.
Rev . May 2001 GraviMaster -FGB-M05 (S) Page 34 Gravimetric Blender For e xample if the alarm report must be activ ated. First select the option fi eld by using the up- and down-k eys. No w press <ENTER> to activ ate the option fi eld. If the option fi eld displays a [X] the alarm report is activ ated.
Rev . May 2001 GraviMaster -FGB-M05 (S) Page 35 Gravimetric Blender PR O TECTED P ARAMETERS Parameter Description Init BatchW eight T otal weight of one batch.
Rev . May 2001 GraviMaster -FGB-M05 (S) Page 36 Gravimetric Blender 3.6 Reports and overviews There is the possibility of printing sev eral reports and ov erviews. Underneath a list is made with the reports and ov erviews with behind them the section and page where instructions for printing are giv en.
Rev . May 2001 GraviMaster -FGB-M05 (S) Page 37 Gravimetric Blender 3.7.3 Change date and time Date and time of the terminal can be changed by entering menu (F1) ‘ system / time and date ’ . 3.7.4 Revision code of the system The terminal has the possibility to display the re vision and those of the connected controllers.
Rev . May 2001 GraviMaster -FGB-M05 (S) Page 38 Gravimetric Blender Reference to section: Production Production status § 3.3.1 Material usage § 3.3.2 Controller Select recipe § 2.1 Public parameters § 3.5.1 Protected parameters § 3.5.2 Alarm history § 5.
Rev . May 2001 GraviMaster -FGB-M05 (S) Page 39 Gravimetric Blender 4.0 INST ALLA TION 4.1 Services For installation 1ph or 3ph supply is required dependent on type of unit and a 1/4 ” air supply with a minimum 6bar .
Rev . May 2001 GraviMaster -FGB-M05 (S) Page 40 Gravimetric Blender The foot plate of the Gra viMaster should be attached on a steel attachment plate on the frame or mezzanine or fl ange pertinent to the machine. The mounting holes are 9 mm and are positioned as sho wn in drawing 4.
Rev . May 2001 GraviMaster -FGB-M05 (S) Page 41 Gravimetric Blender 5.0 Alarms 5.1 Alarm reports and solutions The operating system sends a message to the terminal when a failure is detected. The message will be displayed and stored with date and time in the alarm history .
Rev . May 2001 GraviMaster -FGB-M05 (S) Page 42 Gravimetric Blender ALARMS Alarm-message Description Action to cancel alarm Press enter Alarm already cancelled Press enter Operator must con fi rm No .
Rev . May 2001 GraviMaster -FGB-M05 (S) Page 43 Gravimetric Blender *) If this error occurs frequently contact your dealer **) Other problems which initiate this error are: - The weighbinDumpT ime too.
Rev . May 2001 GraviMaster -FGB-M05 (S) Page 44 Gravimetric Blender [0]OPERA TING A UT O[ ] [ ] [ ] ST A TUS:[0] FGB#00: (No name) ST A TUS OPERA TING ----------------------------[ALARM HISTOR Y] No c.
Rev . May 2001 GraviMaster -FGB-M05 (S) Page 45 Gravimetric Blender 6.0 MAINTENANCE AND REP AIR Make sure ,when maintenance or repair is carried out, the po wer is shut of f (by pulling the plugs out) and the air pressure (by disconnecting the air pressure).
Rev . May 2001 GraviMaster -FGB-M05 (S) Page 46 Gravimetric Blender 6.2 Replacement of parts 6.2.1 Replacement of printed circuit For the replacement of the printed circuit of the control-box, the co ver should be remo ved by unscre wing the bolts. unplug the connectors which are attached to the printed circuit.
Rev . May 2001 GraviMaster -FGB-M05 (S) Page 47 Gravimetric Blender 7.0 TECHNICAL INFORMA TION 7.1 General machine speci fi cations Connecting voltage : 1-phase 240 V Communication cable : Fiber optic cable (or RS – 422) Air pressure : max.
Rev . May 2001 GraviMaster -FGB-M05 (S) Page 48 Gravimetric Blender Drawing 7.1 Cylinder Drawing 7.2 T opview v alves 7.4 Air pressur e cylinders speci fi cations See speci fi cations on cylinder .
Rev . May 2001 GraviMaster -FGB-M05 (S) Page 49 Gravimetric Blender 7.5 Electrical diagrams.
Rev . May 2001 GraviMaster -FGB-M05 (S) Page 50 Gravimetric Blender.
Rev . May 2001 GraviMaster -FGB-M05 (S) Page 51 Gravimetric Blender.
Ein wichtiger Punkt beim Kauf des Geräts GE FGB-M05 (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie GE FGB-M05 noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für GE FGB-M05 - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von GE FGB-M05 reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über GE FGB-M05 erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon GE FGB-M05 besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von GE FGB-M05 verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit GE FGB-M05. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei GE FGB-M05 gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.