Benutzeranleitung / Produktwartung 6K16V des Produzenten GarrettCom
Zur Seite of 63
i www Garre t t C om c om .. www Garre t t C om c om .. Corporate Headquarters GarrettCom, Inc. 213 Hammond Ave. Fremont, CA 94539 Phone (510) 438-9071 Fax (510) 438-9072 Website: http ://www.
Magnum 6K16V Managed Fiber Switch Installation and User Guide (06/04) Magnum 6K16V Managed Fiber Switch Hardware Installation and User Guide Part #: 84-00125 (Rev.
Magnum 6K16V Managed Fiber Switch Installation and User Guide (06/04) Contacting GarrettCom, Inc Please use the mailing address, phone and fax numbers and email address listed below: GarrettCom, Inc. 213 Hammond Ave. Fremont, CA 94539 Phone (510) 438-9071 Fax (510) 438-9072 Website: http ://www.
Magnum 6K16V Managed Fiber Switch Installation and User Guide (06/04) Table of Conten ts ................................................................................. Page 1.0 SPECIFICATIONS ........................................................
Magnum 6K16V Managed Fiber Switch Installation and User Guide (06/04) 5.0 Introduction - Magnum 6K16V Managed Fiber Switch PM ........... 37 5.1 Inspecting the Package and Product .................................................. 37 5.2 6KPM Module Description .
Magnum 6K16V Managed Fiber Switch Installation and User Guide (06/04) THE MAGNUM LINE Ethernet connect ivity products "Designed and Manufactured i n the USA" Overview GARRETTCOM, INC. OFFERS THE PREMIUM-QUALITY MAGNUM LINE OF ETHERNET LAN CONNECTIVITY PRODUCTS WITH INDUSTRY-STANDARD FUNCTIONAL ITY AND BUILT-IN FIBER CONFIGURABILITY.
Magnum 6K16V Managed Fiber Switch Installation and User Guide (06/04) 8 OR 9-PORT AND 4 OR 5-PORT PE RSONAL HUBS, W/ MAN. UP-LINK SW . MEDIA CONVERTERS, 10MB AND 100MB SERIES ALL MEDIA COMBINATIONS, INCL .
Magnum 6K16V Managed Fiber Switch Installation and User Guide (06/04) 1.0 SPECIFICATIONS 1.1 Technical Specifications Performance Filtering / Forwarding Rate: Ethernet:14,880 pps Fast Ethernet: 148,800 pps Gigabit Ethernet: 1, 488,000 pps Switching Processing Type: Store and Forward with IEEE 802.
Magnum 6K16V Managed Fiber Switch Installation and User Guide (06/04) Fiber Single-mode conn ector types: Fiber Port, SC-type: Fiber optic single-mode, 100BASE-FX Fiber Port, LC-type Fiber SFF single-.
Magnum 6K16V Managed Fiber Switch Installation and User Guide (06/04) For DC internal power supplie s at –48VDC, 24VDC and 125VDC, including Dual Source options ( for continuity of operation when either of the DC input sources are interrupted) , see Appendices B and C.
Magnum 6K16V Managed Fiber Switch Installation and User Guide (06/04) 1.2 Ordering Information Magnum Managed Fiber Switch (16 ports max) MODEL DESCRIPTION Magnum 6K16V -Magnum 6K16V Managed Fiber Sw .
Magnum 6K16V Managed Fiber Switch Installation and User Guide (06/04) fiber ports connector GBPM-2OTX Two-port Gigabit 6K module for 6K 16V Switches, provides two GBIC open transceiver port for a user.
Magnum 6K16V Managed Fiber Switch Installation and User Guide (06/04) 2.0 Introduction 2.1 Inspecting the Package and Product Examine the shipping container for obvious damage prior to installing this product; notify the carrier of any damage that you believe occurred during shipment or delivery.
Magnum 6K16V Managed Fiber Switch Installation and User Guide (06/04) 2.2 Product Description - Mag num 6K16V Managed Fiber Switch M agnum 6K16V Managed Fiber Switches pr ovide modularity of fiber and copper ports, 10Mb 100Mb and Gigabit speed ports, and comprehensive management software in a compact industrial-grade packag e.
Magnum 6K16V Managed Fiber Switch Installation and User Guide (06/04) all of these, and is available now. Magnum 6K16V Managed Fiber Switche s have heavy duty metal cases and auto-ranging power supplies for operation with standard AC power worldwide. Internal DC power supplies are optional.
Magnum 6K16V Managed Fiber Switch Installation and User Guide (06/04) operation” on that port when lit, the F/H LE D indicates operation in full-duplex mode when ON (half-duplex when OFF), and the blinking ACT LED indicates receiving Activity on the port.
Magnum 6K16V Managed Fiber Switch Installation and User Guide (06/04) available as four 10/100 switched RJ-45 copper ports and two 100Mb switched multi- mode fiber ST, SC or single mode SC or Long Reach SC ports. For ports numbering, ports 1,3,5,7 are copper, ports 2 and 6 are fibe r, ports 4 and 8 are not present.
Magnum 6K16V Managed Fiber Switch Installation and User Guide (06/04) 2.2.4 Four-Port 10 Mb and 100Mb mm Fiber ST Modules The 4-port @10Mb ST fiber modules be have the same as the 4@100Mb ST fiber modules except for the 10Mb speed. For ports numbering, ports 1, 2, 5, 6 are present, ports 3, 4.
Magnum 6K16V Managed Fiber Switch Installation and User Guide (06/04) The 1000Mb Gigabit fiber-port modules on the Magnum 6K16V are normally set (factory default) to operate in full- duplex mode for best fiber distance and performance.
Magnum 6K16V Managed Fiber Switch Installation and User Guide (06/04) load is greatest. When the Magnum 6K16V Switch detects that its free buffer queue space is low, the Switch sends industry standard (fu ll-duplex only) PAUSE packets out to the devices sending packets to cause “flow cont rol”.
Magnum 6K16V Managed Fiber Switch Installation and User Guide (06/04) 2.3 Features and Benefits Managed switching for high performance Ethernet LA Ns Magnum 6K16V Switches provide non-blocking (all ports can run at full speed at once) performance with standard Managed Networks Software (MNS-6K) included.
Magnum 6K16V Managed Fiber Switch Installation and User Guide (06/04) 2.4 Applications Magnum 6K16V Fiber Switches offe r high performance, modularity and availability. They provide the flexibility of 100Mbps fiber and copper ports as well as single or dual Gigabit(1000Mb) ports, with industry-standard LAN management software.
Magnum 6K16V Managed Fiber Switch Installation and User Guide (06/04) 10 or 100Mb fiber provide a very widespread option to the users to mix match their legacy and advance network needs.
Magnum 6K16V Managed Fiber Switch Installation and User Guide (06/04) 100Mbps full-duplex future-proof fiber medi a to provide secure long distance LAN connection. The entire network is sharing a higher bandwidth Gigabit-enabled data- mining server for the vital database located in a separate secured building.
Magnum 6K16V Managed Fiber Switch Installation and User Guide (06/04) 3.0 Installation Before installing the equipment, it is necessary to take the following precautions: 1.) If the equipment is mounted in an enclosed or multiple rack assembly, the environmental temperature around the equipment must be less than or equal to 50 0 C.
Magnum 6K16V Managed Fiber Switch Installation and User Guide (06/04) IEEE Standard Media Type Max. Dis tance Port Modu le Fiber: 100BASE-FX m m 1 Fiber 220m ( ft) GBIC-SXSC sgl.m 2 Fiber 5Km GBIC-LXSC 100BASE-FX m m 1 Fiber 2.0km (6,562 ft) 6K6-MSC, -MST sgl.
Magnum 6K16V Managed Fiber Switch Installation and User Guide (06/04) (9/125 microns for single-mode, 50/125 or 62.5/125 microns for multi-mode where xx/xx are the diameters of the core and the core plus the cladding respectively).
Magnum 6K16V Managed Fiber Switch Installation and User Guide (06/04) The following procedure describes how to connect a 1000BASE-T tw isted pair segment to the RJ-45 port. The procedure is the sa me for both unshielded and shielded twisted pair cables.
Magnum 6K16V Managed Fiber Switch Installation and User Guide (06/04) into holding position by moving the bottom of the 6K16V inwards to a vertical position. The DIN-Rail latches and brackets are heavy duty, and will hold the 6K16V securely in position, even with cabling attached to the unit.
Magnum 6K16V Managed Fiber Switch Installation and User Guide (06/04) Note that the back of the 6K16V unit is held out from the panel or wall behind it, creating a rear space of about ¼ inch or 1cm. This allows air circulation and cooling of the rear part of the case.
Magnum 6K16V Managed Fiber Switch Installation and User Guide (06/04) to the unit. Power supply options are available to suit the 6K16V Switches to special high- availability communications and/or hea.
Magnum 6K16V Managed Fiber Switch Installation and User Guide (06/04) 3.6 6K16V Port Module (6KPM) Installation Note: the modules used in the 6K16V vertical mount unit are similar to those used in rack-mount 6K units, except that the top LEDs are positioned for front viewing for the vertical-mount 6K16V model.
Magnum 6K16V Managed Fiber Switch Installation and User Guide (06/04) Step 2. Remove Chassis Cover The Magnum 6K16V chassis consists of top-bottom, front and rear parts and assembled together with the help of 18 Philip s-head screws.
Magnum 6K16V Managed Fiber Switch Installation and User Guide (06/04) Step 3. Remove front panel face p late retaining screws There are two PM slots (A, B) located on the front of the chassis cover.
Magnum 6K16V Managed Fiber Switch Installation and User Guide (06/04) Fig 3.6.2b Granddaughter Board placed in slot A and secured with three 5/16 stand- off’s Step 3. The figure here illustrates the basic layout of an individual PM card. Each 6KPM card fits into the space provided on the m ain board.
Magnum 6K16V Managed Fiber Switch Installation and User Guide (06/04) Step 5. Once the latching connectors are aligned properly and the mounting holes are aligned with stand offs then press slowly and firmly with two fingers (as shown below in Fig. 3.
Magnum 6K16V Managed Fiber Switch Installation and User Guide (06/04) installed inside of the top cover. Step 8. Once all 6KP M cards have been installed (including faceplates for empty slots), the chassis cover should be repl aced. Make sure the chassis cover is aligned properly before securing the enclosure.
Magnum 6K16V Managed Fiber Switch Installation and User Guide (06/04) 3.7 Connecting a Management Console Terminal to Magnum 6K16V Use a DB-9 “null modem” cable (use on any serial port)or “one D.
Magnum 6K16V Managed Fiber Switch Installation and User Guide (06/04) 4.0 OPERATION This chapter describes the functions and operation of the Magnum 6K16V Switch. 4.1 Switching Functionality A Magnum 6K16V provides switched connec tivity at Ethernet wire-speed among all of its ports.
Magnum 6K16V Managed Fiber Switch Installation and User Guide (06/04) 4.2 Status LEDs For all Magnum 6K16V models : PWR : Power LED, O N when external power is applied to the unit. LK : Steady ON, Link status for 10 Mbps and 100Mbps operation. ACT : ON with port activity for 10 Mbps and 100Mbps operation.
Magnum 6K16V Managed Fiber Switch Installation and User Guide (06/04) When Magnum 6K16V RJ-45 copper ports are set for auto-negotiation and are connected to another auto-negotiating device, there are 4 different speed and F/H modes possible depending on what the other device supports.
Magnum 6K16V Managed Fiber Switch Installation and User Guide (06/04) 4.5 Flow-control, IEEE 802.3x standard Magnum 6K16V Switches incorporate a flow-control mechanism for Full- Duplex mode. The purpose of fl ow-control is to reduce the risk of data loss if a long burst of activity causes the switch to save fra mes until its buffer memory is full.
Magnum 6K16V Managed Fiber Switch Installation and User Guide (06/04) Fiber Port Module Speed, Std. Mode Std. km fdx (hdx) Wave - length nm Cable Size m X’mitr Output P T , dB R’cvr Sens. P R , dB Worst OPB, dB Worst* distance Km, fdx typical OPB, dB typical* distance Km, fdx 6KP4V- F10ST 10Mb FL Multi- Mode 2 (2) 850 62.
Magnum 6K16V Managed Fiber Switch Installation and User Guide (06/04) 5.0 Introduction - Magnum 6K16V Managed Fiber Switch Port Modules This chapter describes each Port Module (PM), including appearance, functionality, and status displays. 5.1 Inspecting the Package and Product This section applies only to PMs shippe d as separate items, i.
Magnum 6K16V Managed Fiber Switch Installation and User Guide (06/04) 5.2.1 6KP6-RJMST, 4@10/100Mbps RJ-45 and 2@100Mb multi-mode FX-ST “twist lock” Combo Module The Magnum 6KP6-RJMST is a co mbo 6 port module of RJ-45’s at 10/100Mbps and fiber optic ports at 100MB.
Magnum 6K16V Managed Fiber Switch Installation and User Guide (06/04) 39 www Garre t t C om c om .. RJ10MST, 6KP4- 4 Port@ 10Mb ST Fiber Port 2 2 6 T LK RX ACT H F/ TX RX LK ACT H F/ TX R X LK ACT H F/ TX RX LK ACT H F/ 1 5 3 1 FULL/HALF 1 ACTIVITY LINK 2 3 The Magnum 6KP4-F10ST is a 10Mb multi-mode fiber module with 4 ST- Fiber ports.
Magnum 6K16V Managed Fiber Switch Installation and User Guide (06/04) module allow to connect the 100Mb demand of Switch devices. It supports distances according to the 10Base-FL standard i.e, 2Km distance for multi-m ode fiber. (Single- mode for 10Km distance m ay be available as a special order).
Magnum 6K16V Managed Fiber Switch Installation and User Guide (06/04) as 25+ Km (see Power Budget, Section 4.5) Each port has an Activity (ACT) LED indicating packets being received, a Link (LK) LED that indicates proper connectivity with the remote device when lit, and a FDX/HDX LED to indicate full-duplex mode wh en lit (or half-duplex when off).
Magnum 6K16V Managed Fiber Switch Installation and User Guide (06/04) LED is OFF. 5.2.5 6KP8-MTRJ, 8 @100Mb multi-mode FX , MTRJ Small-Form-factor Magnum 6KP8-MTRJ is a multi-mode fiber optic 8-port module equipped with a small-form-factor MTRJ-type connector.
Magnum 6K16V Managed Fiber Switch Installation and User Guide (06/04) essentially the same as the ST and SC -types. It has the same LEDs per port indicating port activity (ACT), Li nk (LK), and FDX or HDX operation 5.
Magnum 6K16V Managed Fiber Switch Installation and User Guide (06/04) the remote device when lit, and a FDX/HDX LED indicating full-duplex mode when lit (or half-duplex when off).
Magnum 6K16V Managed Fiber Switch Installation and User Guide (06/04) connecting to a hub or another switch. The switch is configured as (=) position by de fault settings from the factory, the left-most RJ-45 port is used for segments going to workstations and other user node device connections as other ports of the module.
Magnum 6K16V Managed Fiber Switch Installation and User Guide (06/04) 5.2.10a 6KP8-45-2LC, 6@ 10/100Mbps RJ-45 and 2@100Mb single-mode FX , LC Small-Form-Factor The Magnum 6KP8-45SLC eight port M odule is a combo m odule with copper and fiber (Small Form Factor) LC type fiber ports.
Magnum 6K16V Managed Fiber Switch Installation and User Guide (06/04) removing the transceiver, press the clips on eith er side of the transceiver at the same tim e and pull the transceiver out. Each port has an Activity (ACT) LED indicating packets being received and a Link (LK) LED indicating proper connectivity with the remote device when lit.
Magnum 6K16V Managed Fiber Switch Installation and User Guide (06/04) 6.0 TROUBLESHOOTING All Magnum Ethernet products are designed to provide reliability and consistently high performance in all network environments . The installation of a Magnum 6K16V Switch is a st raightforward procedure (see INSTALLATION, Section 2.
Magnum 6K16V Managed Fiber Switch Installation and User Guide (06/04) 6.2 When Calling for Assistance Please be prepared to provide the following information. 1. A complete description of the problem, including the following points: a. The nature and duration of the problem; b.
Magnum 6K16V Managed Fiber Switch Installation and User Guide (06/04) GarrettCom will carefully test and evaluate all returned products, will repair products that are under warranty at no charge, and w ill return the warranty-repaired units to the sender with shipping charges prepaid (see Warranty Information, Appendix A, for complete details).
Magnum 6K16V Managed Fiber Switch Installation and User Guide (06/04) APPENDIX B : Internal DC Power Supply Options B1.0 SPECIFICATIONS FOR MAG NUM 6K16V SWITCHES, DC POWER Power Magnum 6K16V models, .
Magnum 6K16V Managed Fiber Switch Installation and User Guide (06/04) applied to the two inputs. It protects the Switch from incorrect DC input connections. An incorrect polarity connection, for example, w ill neither affect the Switch, its internal power supply, nor will it blow the fuse in the internal power supply.
Magnum 6K16V Managed Fiber Switch Installation and User Guide (06/04) hooked up at the last. When power is applied, the green PWR LED will illuminate. Note: The GND should be hooked up first. The 6K16V unit has a floating ground, so the user may elect to Gr ound either + or = terminal to suit th e customer’s us e.
Magnum 6K16V Managed Fiber Switch Installation and User Guide (06/04) APPENDIX C: Internal DC Dual-Source Power Option C1.0 SPECIFICATIONS - FOR MAGNUM 6K16V FIBER SWITCH Power Supply (Internal, -48VD.
Magnum 6K16V Managed Fiber Switch Installation and User Guide (06/04) C4.0 FEATURES AND BENEFITS OF THE DUAL-SOURCE DESIGN a) The Switch unit can receive power from either input, “A” or “B”. The hub will normally draw its power from the DC source with the highest voltage at a given tim e.
Magnum 6K16V Managed Fiber Switch Installation and User Guide (06/04) C5.1 UL Require me nts The following must be adhered to in or der to conform to UL requirements: 1. Minimum 18 AWG cable for connection to a Centralized DC power source. 2. Minimum 14 AWG cable for conn ection to earthing wiring.
Ein wichtiger Punkt beim Kauf des Geräts GarrettCom 6K16V (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie GarrettCom 6K16V noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für GarrettCom 6K16V - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von GarrettCom 6K16V reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über GarrettCom 6K16V erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon GarrettCom 6K16V besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von GarrettCom 6K16V verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit GarrettCom 6K16V. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei GarrettCom 6K16V gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.