Benutzeranleitung / Produktwartung RELIABILITY D1859 des Produzenten Fujitsu
Zur Seite of 42
Technical manual System board D1859 (Econel 50) English reliabilit y 2.
Are there ... ... any technical problems or ot her questions y ou need clarified? Please contact: ● your sales partner ● your sales outlet ● our hotline for customers who have purchased the system board as a single delivery unit: +49(0) 180 3777 005 The latest information and updates (e.
Intel, Pentium and Celeron are register ed trademarks of Intel Corporation, USA. Microsoft, MS, MS-DOS and Windows are regist ered trademarks of Microsoft Corporation. PS/2 and OS/2 Warp are registered trademarks of International Business Machines, Inc.
.
D1859 (Econel 50) Contents System board D1859 ............................................................................................................. ............. 1 Notational conventions ........................................................
.
D1859 (Econel 50) 1 System board D1859 Your sy stem board is available in different c onfiguration levels. Depending on the configuration chosen, some of the hardware components descri bed may not be available on y our system board.
Important notes 2 D1859 (Econel 50) Important notes With the system board installed y ou must open t he system to access the system board. How to dismantle and reassemble the system is descr ibed in the operating manual accompany ing the system. Connecting cables for peripherals must be adequately shielded to avoid interference.
List of features List of features Onboard features D1859-A Chipset Intel 925 Board size ATX VGA Audio / 8-channel / S/PDIF 5.1 / - / Buzzer / int. Speaker Support - / LAN 1 Gbit / 100 Mbit / 10 Mbit / / LAN ASF / AOL / WOL / Boot / - / / Serial ATA / ATA / RAID / / FireWire TM - USB 2.
List of features 4 D1859 (Econel 50) Internal ports (continued) D1859-A S/PDIF 5.1 (digital Audio)* OUT / IN - / - Audio Input - Front panel Audio (headphone, microphone, AC97) - IEEE 1394 connector* (FireWire TM )- USB Ports* (2.
Brief instructions on installing system board Brief instructions on installing system board If you have purchased a separate sy stem board, you c an install the system board in y our system in accordance with the following brief instructions.
Brief instructions on installing system board 6 D1859 (Econel 50) ► Should no suitable connection field be provided in the case, then you must install the connection field (1) provided. Ensure the plate is aligned properly so that the connections are suitable for the system board later.
D1859 (Econel 50) 7 Interfaces and connectors PCI 2 PCI 3 PCI 5 PCI 4 PCI Ex pr ess x1 PCI Ex pr ess x8 PCI 1 slot 1 slot 3 slot 4 slot 2 Chan nel B Channel A 1 2 3 4 5 6 7 8 16 14 13 12 11 10 9 BI O .
External ports 8 D1859 (Econel 50) External ports 13 4 5 2 6 7 8 1 PS/2 mouse port 5 VGA port 2 Parallel port/printer 6 S erial interface COM1 3 LAN connector (10/100/1000 Mbit/s) 7 USB1 connector 4 USB0 connector 8 PS/2 keyboard board LAN connector The system board is optionally equipped with t he Broadcom BCM5751 LAN controller.
Internal ports and connectors D1859 (Econel 50) 9 Internal ports and connectors The positions of the internal por ts and connectors are shown on the Cover.
Pin assignment of internal ports 10 D1859 (Econel 50) Pin assignment of internal ports The pin assignment of some internal connecti ons is shown in English in the following. i Some of the following connectors may be optional! Front panel Watch the poling of the LEDs.
Pin assignment of internal ports D1859 (Econel 50) 11 IDE/ATA interface 1 2 Pin Signal Pin Signal 1 Reset drive (low asserted) 2 GND 3 Data 7 (high asserted) 4 Data 8 (high asserted) 5 Data 6 (high as.
Pin assignment of internal ports 12 D1859 (Econel 50) USB - dual channel 1 2 11 12 Pin Signal Pin Signal 1 Key 2 Chipcardreader on or not connected 3 VCC 1 or 3 4 VCC 2 or 4 5 Data negative 1 or 3 6 D.
Pin assignment of internal ports D1859 (Econel 50) 13 Floppy interface 1 Pin Signal Pin Signal 1 GND 18 Step DIR (low asserted) 2 FDHDIN (low asserted) 19 GND 3 GND 20 Step Pulse (low asserted) 4 not .
Pin assignment of internal ports 14 D1859 (Econel 50) LCD display 2 1 Pin Signal Pin Signal 1 SMB CLK 8 LAN Link Icon 2 GND 9 Harddisk Action Icon 3 SMB DATA 10 BMC Alert Icon 4 GND 11 Message Icon 5 .
Pin assignment of internal ports D1859 (Econel 50) 15 Pow er supply BTX (ATX compatible) 1 13 Pin Signal Pin Signal 1 +3.3 V (P3V3P) 13 +3.3 V (P3V3P) 2 +3.
Pin assignment of internal ports 16 D1859 (Econel 50) Pow er supply control (System monitoring) 1 Pin Signal 1 Pow er Guard Control 2 PS FAN Control 4 PS FAN Sense.
17 D1859 (Econel 50) Jumper settings The positions of the jumpers are shown on page "Cover". Setting via control-panel plug connector A C 1 2 1 2 B 1 2 Pin pair A inserted = Skipping system .
18 D1859 (Econel 50) Add-on modules / Upgrading ! Exit energy-saving mode, switch off the sy stem and remove the power plug from the mains outlet, before carrying out any of the procedures described in this chapter! Even when you have run dow n the device, parts of the device (e.
Add-on modules / Upgrading D1859 (Econel 50) 19 a ► Insert the new processor in the socket so that the marking of the processor is aligned with the marking on the socket (a). 1 2 3 ► Fold down the frame (1). ► Press the lever downward (2) until it is hooked in again (3).
Add-on modules / Upgrading 20 D1859 (Econel 50) Mounting heat sink i Use only the heat sink supplied with y our system! Be sure to use heat conducting material bet ween the processor and the heat sink. If a heat conducting pad (rubber-like foil) is al ready applied to the heat sink, then use it.
Add-on modules / Upgrading D1859 (Econel 50) 21 Upgrading main memory Technical data Technology: DDR2 400 / DDR2 533 unbuffered DIMM modules 184-Pin; 1.
Add-on modules / Upgrading 22 D1859 (Econel 50) Installing a memory module 2 2 ► Push the holders on each side of the memory slot outwards. ► Insert the memory module into the location (1). ► At the same time flip the lateral holders upw ards until the memory module snaps in place (2).
Add-on modules / Upgrading D1859 (Econel 50) 23 Adding PCI Express cards The PCI Express x8 slot is intended for graphi cs cards, and the PCI Express x1 slot for PCI Express x1 cards. Adding PCI cards Technical data: 32 bit / 33 MHz PCI slots 3.3 V supply voltage (PCI 2.
Add-on modules / Upgrading 24 D1859 (Econel 50) Multifunctional expansion cards or expansion cards w ith integrated PCI-PCI bridge: These expansion cards require up to four PCI interrupts: INT A, INT B, INT C, INT D. How many and which of these interrupts are used is specifi ed in the documentation provided with the card.
Add-on modules / Upgrading D1859 (Econel 50) 25 Replacing the lithium battery In order to permanently save the sy stem informati on, a lithium battery is installed to provide the CMOS-memory with a current. A corresponding erro r message notifies the user w hen the charge is too low or the battery is empty .
Add-on modules / Upgrading 26 D1859 (Econel 50) BIOS update When should a BIOS update be carried out? Fujitsu Siemens Computers makes new BIOS ver sions available to ensure compatibility to new operating systems, new softw are or new hardware. In addition, new BIOS functions can also be integrated.
Add-on modules / Upgrading D1859 (Econel 50) 27 BIOS Recovery - Recovering Sy stem BIOS i All BIOS settings are reset to the default values. ► Open the casing as described in the operating manual. ► On the system board set the jumper to the appropriate setting to restore the system BIOS (see chapter "Jumper settings").
Add-on modules / Upgrading 28 D1859 (Econel 50) Microcode Update What is a microcode update? As there are no drivers for processors, Intel offer s the possibility from the P6 family ( Pentium Pro) on to update the command set (microcode) of the processor.
Annex D1859 (Econel 50) 29 Annex System board Revision and BIOS Version System board Rev ision The revision status of the system board exactl y identifies w hich system board y ou have.
Annex 30 D1859 (Econel 50) Electrical Properties Loadability for connections and fuses i Make sure that the connected devices do not overload the connections.
Error messages D1859 (Econel 50) 31 Error messages This chapter contains error me ssages generated by the system board. Available CPUs do not support the same bus frequency - System halted! Memory typ.
Error messages 32 D1859 (Econel 50) DMA test failed EISA CMOS not writable Extended RAM Failed at offset: nnnn Extended RAM Failed at address line: nnnn Failing Bits: nnnn Fail-Safe Timer NMI failed M.
Error messages D1859 (Econel 50) 33 Keyboard error nn nn Stuck Key Release the key on the key board ( nn is the hexadecimal code for the key). Missing or invalid NVRAM token Switch the device off and on again. If the message is still displayed, please contact y our sales outlet or customer service centre.
Error messages 34 D1859 (Econel 50) System Management Configuration changed or Problem occurred A system fan or sy stem sensor has failed. Check the hardware operation. System timer error Switch the device off and on again. If the message is still displayed, please contact y our sales outlet or customer service centre.
35 D1859 (Econel 50) Glossary The technical terms and abbreviations given below represent only a selection of the full list of common technical terms and abbreviations. Not all technical terms and abbreviations listed here are valid for the described system board.
Inf orma tion on this doc umen t On Ap ril 1, 2009 , Fuj itsu be came the so le owner o f Fuj itsu Si emens Comp u- ters. This new subsi diar y of Fujitsu h as b een renam ed Fuj itsu T echnol og y So- lution s.
Ein wichtiger Punkt beim Kauf des Geräts Fujitsu RELIABILITY D1859 (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Fujitsu RELIABILITY D1859 noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Fujitsu RELIABILITY D1859 - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Fujitsu RELIABILITY D1859 reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Fujitsu RELIABILITY D1859 erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Fujitsu RELIABILITY D1859 besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Fujitsu RELIABILITY D1859 verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Fujitsu RELIABILITY D1859. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Fujitsu RELIABILITY D1859 gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.