Benutzeranleitung / Produktwartung HCFU-42CF03 des Produzenten Frymaster
Zur Seite of 29
Operation & Installation Manual HCFU-42CF03 HCFU-42HF03 &EXPOSED CEILING/FLOOR MOUNTING AIR CONDITIONER CONVER TIBLE CEILING/FLOOR MOUNTING Please read this operation manual before using the air conditioner . Please keep this manual carefully and safely .
Contents Cautions ........................................................................... Safety Precautions ........................................................... Features and Functions ................................................... Name of Parts .
Cautions 1 Disposal of the old air conditioner Before disposing an old air conditioner that goes out of use, please make sure it's inoperative and safe. Unplug the air conditioner in order to avoid the risk of child entrapment. It must be noticed that air conditioner system contains refrigerants, which require specialized waste disposal.
2 Cautions For the purpose of safety , the air conditioner must be properly grounded in accordance with specifications. Always remember to unplug the air conditioner before opening inlet grill (page8). Never unplug your air conditioner by pulling on the power cord.
3 Safety Pr ecautions W ARNING! DANGER! Do not attempt to install this air conditioner by yourself. This unit contains no user-serviceable parts. Always consult authorized service personnel for repairs. When moving, consult authorized service personnel for disconnection and installation of the unit.
4 Safety Pr ecautions W ARNING! Provide occasional ventilation during use. Do not direct air flow at fire places or heating apparatuses. Do not climb on and place objects on the air conditioner . Do not hang objects from the indoor unit. Do not set flower vases or water containers on top of the air conditioner .
5 Featur es and Functions AUTOMA TIC OPERA TION SLEEP HEA T & COOL TYPE Merely press the ON/OFF button, and the unit will begin automatic operation in any of the Heating, Cooling and Blow modes as appropriate, in accordance with the thermostat setting and the actual temperature of the room.
6 Featur es and Functions VER TICAL AIR DIRECTION ADJUSTMENT Use the air direction adjustment within the ranges shown above. HORIZONT AL AIR DIRECTION ADJUSTMENT Each time the button is pressed, the air direction range will change as follows: Press the AIR FLOW DIRECTION VER TICAL SET button.
Each time the button is pressed, the air direction range will change as follows: Featur es and Functions 7 The swing range of up-down flap is as follow : air direction louvers RIGHT/LEFT 1 2 3 4 5 3 2.
Name of Parts 8 1 Operating Control Panel 2 Emergency switch 3 Power Indicator Lamp 4 OPERA TION Indicator Lamp 5 TIMER Indicator Lamp 6 Compressor Lamp 7 Remote receiver 8 Inlet Grill ( Filter inside.
9 1. Pull the filters upward to remove them from the Intake Grill. 2. Clean the air filter: Remove the dust from the filters by vacuum cleaner or washing them. After washing, allow the air filters to dry thoroughly in an area protected from sunlight. 3.
10 Operation and Performance *Heating Performance *Microcomputer-contr olled Automatic Defrosting Heat-pump air conditioners heat your entire room by recirculating air throughout the room, with the result that some time may be required after first starting the air conditioner until the room is heated.
11 W ARNING ! CAUTION ! Please ask the dealer or specialist to install, never try by the users themselves. After the installation please be sure of the following conditions. Incorrect installation may cause water leaking, shock and fire hazard. Please call dealer to install the air -conditioner .
1 . SELECTING THE MOUNTING POSITION For authorized service personnel only W ARNING W ARNING CAUTION Installation of Indoor Unit 12 Be careful not to scratch the room air conditioner when handing it. After installation, explain correct operation to the customer , according to the operating manual.
FOR HALF CONCEALED INST ALLA TION (1) Install the indoor unit level on a strong wall which is not subject to vibration. Installation of Indoor Unit 13 (2) The inlet and outlet ports should not be obstructed : the air should be able to blow all over the room.
INST ALLA TION PROCEDURE Install the room air conditioner as follows: CONNECTION PIPE REQUIREMENT T able 1 Model Diameter Liquid side Gas side Maximum length Maximum height (between indoor and outdoor) 9.52 mm 19.05mm 50 m 30 m HCFU-42CF03 HCFU-42HF03 14 Installation of Indoor Unit 1.
15 Installation of Indoor Unit 3. DRILLING THE HOLES AND A TT ACHING THE SUAPENSION BOL TS IF USING ANCHOR BOL TS (1) Drill holes for anchor bolts at the locations at which you will set the suspension bolts. Note that anchor bolts (to be obtained locally).
FOR HALF-CONCESLED INST ALLA TION In order to check the drainage, be sur e to use a level during installation of the indoor unit. If the installation site of the indoor unit is not level, water leskag.
INST ALLING THE COUPLER HEA T INSULA TION After checking for gas leaks, insulate by wrapping insulation around the two parts (large and small) of the indoor unit coupling, using the coupler hest insulation. After installling the coupler heat insulation, wrap both ends with vinyl tape so that there is no gap.
18 Installation of Indoor Unit DRAIN PIPING Install the drain pipe with downward gradient (1/50 to 1/100) and so there are no rises or traps in the pipe. Use general hard polyvinyl chloride pipe (VP25)[outside diameter 38 mm.] During installation of the drain pipe,be careful to avoid applying pressure to the drain point of the unit.
19 Installation of Indoor Unit (1) Install insulation for the drain pipe.(See Fig.12 and 13) Cut the included insulation material to an appropriate size and adhere it to the pipe. Insulation for Drain pipe (T o be obtained locally .Length shoud be at least 8mm.
20 Installation of Indoor Unit ELECTRICAL WIRING HOW TO CONNECT WIRING TO THE TERMINALS (1)Cut the wire and with a wire cutter or wire-cutting pliers,then strip the insulation to about 15/16"(25mm) of expose the solid wire. (2)Using a screwdriver ,remove the terminal screw(s) on the terminal board.
21 Installation of Indoor Unit Insulation tube Cord clamp Use VW-1, 0.5 to 1.0 mm thick, PVC tube as the insulation tube. CAUTION (1) Match the terminal block numbers and connection cord colors with those of the outdoor unit. Erroneous wiring may cause burning of the electric parts.
22 Installation of Indoor Unit FRESH-AIR INT AKE (1)Open up the knockout hole for the fresh-air intake,as shown in Fig.16 (If using half-concealed installation ,open up the top knockout hole instead) CAUTION (1)When removing the cabinet(iron plate),be careful not to damage the indoor unit internal parts and surrounding area(outer case).
W ARNING (1) Remove the cord clamp. (2) Process the end of the connection cords to the dimensions shown in Fig.19. (3) Connect the end of the connection cord fully into theterminal block. (4) Fasten the connection cord with a cord clamp. (5) Fasten the end of the connection cord with the screw .
TEST RUNNING 1. CHECK ITEMS (1) INDOOR UNIT (1) Is operation of each button on the remote control unit normal? (2) Does each lamp light normally? (3) Do not air flow direction louvers operate normally.
25 T r ouble Shooting Followings are not problems Sound of water flowing is not a problem. Sound of cracking is heard. Smell are generated. During operation, white fog or steam comes out from the indoor unit. No outlet air or fan speed can't be changed in dry mode.
26 Before ask for services, please first check your unit against the following. Air conditioner won't start. Poor cooling or heating Is power supply switch turned on? Power supply switch is not set at ON.
HAIER GROUP Qingdao Haier Air Conditioner Electric Co., Ltd. Address: Haier Garden ,Qianwangang Road , Economic Development Zone, Qingdao ,Shandong 266500, P .
Ein wichtiger Punkt beim Kauf des Geräts Frymaster HCFU-42CF03 (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Frymaster HCFU-42CF03 noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Frymaster HCFU-42CF03 - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Frymaster HCFU-42CF03 reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Frymaster HCFU-42CF03 erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Frymaster HCFU-42CF03 besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Frymaster HCFU-42CF03 verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Frymaster HCFU-42CF03. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Frymaster HCFU-42CF03 gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.