Benutzeranleitung / Produktwartung CP05C10 des Produzenten Friedrich
Zur Seite of 24
Room Air Conditioner Ser vice and P ar ts Man ual C P05 .Svc (0 5 /0 6 ) CP05C10.
—2— CONTENTS 1. PREF A CE ...................................................................................................................................................3 1.1 FEA TURES...........................................................
1. PREF A CE This ser vice manual provides v ar ious ser vice inf or mation, including the mechanical and electrical par ts, etc. This room air conditioner was manuf actured and assembled under a strict quality control system. The refrigerant is charged at the factory .
—4— 1.3 LOCA TIONS OF CONTR OLS 1 2 3 4 6 5 MONEY SAVER 2 The fan stops when the compressor stops cooling. • Approximately every 3 minutes the fan will turn on and sample the room air to determine if more cooling is needed. TEMPERATURE SETTING 1 • These buttons control the temperature of the room.
— 5 — 2. DISASSEMBL Y INSTR UCTIONS 2.1 MECHANICAL P AR TS 2.1.1 FRONT GRILLE 1. Pull the inlet grille forw ard. 2. Remov e the screw securing the F ront Gr ille. (Fig. 3) 3. Push the grille up from the bottom and pull the top of the grille aw ay from the case to lift the top tabs out of their slots.
— 6 — 2.2 AIR HANDLING P AR TS 2.2.1 AIR GUIDE UPPER 1. Disconnect the unit from the pow er source . 2. Remov e the front grille. (Ref er to Section 2.1.1) 3. Remov e the cabinet. (Refer to Section 2.1.2) 4. Rem o v e the control panel. (Ref er to Section 2.
— 7 — 2.2.3 MO T OR 1. Disconnect the unit from the pow er source . 2. Remov e the front grille. (Ref er to Section 2.1.1) 3. Remov e the cabinet. (Refer to Section 2.1.2) 4. Rem o v e the control panel. (Ref er to Section 2.1.3) 5. Rem o v e the uppe r air guide .
— 8 — 2.3.2 COMPRESSOR 1. Remov e the front grille and cabinet. (Ref er to Section 2.1) 2. Discharge the refrigerant by using a refrigerant recov er y system. 3. Remov e the ov erload protector . (Ref er to Section 2.3.1) 4. After discharging the unit completely , unbrace the suction and discharge pipes at the compressor connections.
— 9 — 2.3.6 PO WER CORD 1. Disconnect the unit from source of power . 2. Remov e the front grille. (Ref er to Section 2.1.1) 3. Remov e the cabinet. (Refer to Section 2.1.2) 4. Rem o v e a scr e w that secures control panel to base pan. (Ref er to Section 2.
2.4.2 EV APORA T OR 1. Remov e the cabinet. 2. Discharge the refrigerant by using a refrigerant recov er y system. 3. Rem o v e the uppe r air guide . (Re f er to Section 2.2.1) 4. After discharging the refrigerant completely , unbraze the interconnecting tube at the condenser connections.
— 11 — Equipment needed: V acuum pump , charging cylinder , manifold gauge , brazing equipment, pinch-off tool capable of making a vapor proof seal, leak detector , tubing cutter , hand tools to remov e components and ser vice valv e.
— 12 — 2 . 4.4 ELECTRICAL D AT A USE OF EXTENSION CORDS Because of potential saf ety hazards, w e strongly discourage the use of an e xtension cord. Howe ver , if you wish to use an e xtension cord, use a CSA cer tified/UL-listed 3-wire (grounding) e xtension cord, rated 15A, 125V .
— 13 — 3 .2 PIPING SYSTEM F ollowing is a brief descr iption of the impor tant components and their function in what is called the refr igeration system. Ref erence should be made to Figure 32 to follow the refrigerating cycle and the flo w of the refr igerant in the cooling cycle.
— 14 — 3 .3 T R OUBLESHO O TING GUIDE In general, possib le trouble is classified in two kinds. The one is called Starting Failure which is caused b y an electrical defect. The other is Ineffective Air Con- ditioning caused by a def ect in the refrigeration circuit and improper application.
— 15 — Fails to Start Improper ther mostat setting Loose terminal connection Improper wiring Che c k voltage power source. Drop of power v oltage. Capacitor check. Replacement. Che c k control s witch setting. Compressor f ails to star t. De f ect of compressor or capacitor .
COMPLAINT CA USE REMED Y F an motor will not run. No power Check v oltage at outlet. Correct if none. P o w er supply cord Che c k v oltage to electronic control board. If non e , check p o w er supply cord. Replace cord if circuit is open. Wire disconnected or Connect wire.
— 17 — COMPLAINT CA USE REMED Y F an motor noise. F an blade If crac ked, out of balance , or par tially missing, replace it. Bl o w er wheel If c r a c k ed, out of balanc e , or pa r tially missing, replace it. Loose set screw Tighten it. W o r n bea r ings If kno c king sounds cont i n ue when r unning replace the moto r .
— 18 — COMPLAINT CA USE REMED Y Compressor cycles on F an motor If not r unning, deter mine the cause. Replace if ov er load. required. Condenser air flow Remov e the cabinet, inspect the inter ior surf ace restriction of the condenser . If restricted, clean carefully with a vacuum cleaner (do not damage fins) or brush.
— 19 — 4 . CIRCUIT DI A GRAM WH(BL) POWER INPUT BK(BR) (Ribbed) (Plain) GN/YL (GN) GN/YL(GN) THERMIST OR BK BK BL RD BL RD CN-TH1 YL YL OR(BR) OR(BR) OR SYNC M OTOR R Y -LO R Y -HI CN-WORK CN-SYNC CN-DISP DISPLA Y P .W.B ASM R Y -SYNC 250V/T2A (115V/T2A) TRANS FORMER ZNR 43 R Y -COMP MAIN P .
— 20 — 5 . EXPLODED VIEW 352390 130410 359012 W48602 354210 349480 352390-1 149980 559011 346811 554030 W48602 130910 550140 554160 567502 352115 552102 352111 352113 35211A 135313 135303 152302 1.
LocNo FRIEDRICH DESCRIPTION 130410 67302921 Base Assy Single 130910 67303709 Cabinet Assy Single 135312 67306003 Grille Assy Front 135313 67304200 Grille Assy Inlet 14758 1 67304600 Link 147582- 1 67304501 Louver Vertical 2 ea.
— 22 — MEMO.
— 23 — MEMO.
Post Office Box 1540 • 4200 N. Pan Am Expressway • San Antonio, Texas 78295-1540 • (210) 357-4400 • FAX (210) 357-4490 FRIEDRICH AIR CONDITIONING CO.
Ein wichtiger Punkt beim Kauf des Geräts Friedrich CP05C10 (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Friedrich CP05C10 noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Friedrich CP05C10 - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Friedrich CP05C10 reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Friedrich CP05C10 erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Friedrich CP05C10 besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Friedrich CP05C10 verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Friedrich CP05C10. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Friedrich CP05C10 gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.