Benutzeranleitung / Produktwartung Self-Contained Package Air Conditioner des Produzenten Franklin
Zur Seite of 12
P RODUCT S PECIFICA TIONS SS-PCB50 www .goodmanmfg.com 6/06 Supersedes 12/05 S ELF -C ONT AINED P ACKAGE A IR C ONDITIONER The PCB Commercial 50 Hz self-contained packaged air conditioner is designed for ground-level or rooftop application. PCB C OMMERCIAL S ERIES 50 Hz C OOLING C AP ACITY : 90,000 TO 180,000 BTU/ H 7½, 10, AND 15 T ON [26.
2 SS-PCB50 P RODUCT S PECIFICA TIONS S PECIFICA TIONS PCB090-5 PCB120-5 PCB180-5 T otal Cooling - BTU/h (kW) 88,400 (25.9) 118,600 (34.8) 172,000 (50.4) Sensible Cooling - BTU/h¹ (kW) 67,100 (19.7) 89,200 (26.1) 131,000 (38.4) EER² 8.9 9.7 8.5 Indoor Blower (Qty .
SS-PCB50 3 P RODUCT S PECIFICA TIONS UNIT SIZE A - HEIGHT B - SUPPL Y AIR C - RETURN AIR 090 36” (914 mm) 12½” (318 mm) 179/16” (446 mm) 120,180 52” (1321 mm) 20¼” (514 mm) 2513/16” (656 mm) D IMENSIONS All dimensions in inches and millimeters.
4 SS-PCB50 P RODUCT S PECIFICA TIONS E LECTRICAL C ONNECTIONS Main power entrance location (with electric heat installed) Control wiring entrance location Main power entrance location (without electric heat installed) Note: Single-point wiring is available at location #1 when heat kit is installed.
SS-PCB50 5 P RODUCT S PECIFICA TIONS CFM EXTERNAL ST A TIC PRESSURE (INCHES W .C.) SEE NOTE (3) 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP 2600 669 0.44 816 0.59 916 0.75 1004 0.92 1084 1.09 1157 1.
6 SS-PCB50 P RODUCT S PECIFICA TIONS Motor Sheave - Adjustable Factory Setting F an Sheave - Fixed T wo T urns Opens Motor Sheave T urns Open 0 1 2 3 4 5 F an RPM 3.0 HP Motor 1242 1186 1129 1073 1016 960 Note: Allow ±5% variation in blower RPM due to pulley manufacturing tolerances.
SS-PCB50 7 P RODUCT S PECIFICA TIONS Motor Sheave - Adjustable Factory Setting F an Sheave - Fixed 2 T urns Opens Motor Sheave T urns Open 012345 F an RPM 5.0 HP Motor 1400 1446 1273 1209 1146 1082 Note: Allow ±5% variation in blower RPM due to pulley manufacturing tolerances.
8 SS-PCB50 P RODUCT S PECIFICA TIONS INDOOR AIR CONDENSER AIR TEMPERA TURE 75°F 85°F 95°F 105°F 115°F SCFM WB To t a l Kbtuh Sens Kbtuh Kw To t a l Kbtuh Sens Kbtuh Kw To t a l Kbtuh Sens Kbtuh Kw To t a l Kbtuh Sens Kbtuh Kw To t a l Kbtuh Sens Kbtuh Kw 2550 72 111.
SS-PCB50 9 P RODUCT S PECIFICA TIONS INDOOR AIR CONDENSER AIR TEMPERA TURE 23.9°C 29.4°C 35.0°C 40.6°C 46.1°C L/S WB T otal Cap. Sens Cap. Kw T otal Cap. Sens Cap. Kw T otal Cap. Sens Cap. Kw T otal Cap. Sens Cap. Kw T otal Cap. Sens Cap. Kw 2246 22.
10 SS-PCB50 P RODUCT S PECIFICA TIONS INDOOR AIR CONDENSER AIR TEMPERA TURE 75°F 85°F 95°F 105°F 115°F SCFM WB To t a l Kbtuh Sens Kbtuh Kw To t a l Kbtuh Sens Kbtuh Kw To t a l Kbtuh Sens Kbtuh Kw To t a l Kbtuh Sens Kbtuh Kw To t a l Kbtuh Sens Kbtuh Kw 4760 72 219.
SS-PCB50 11 P RODUCT S PECIFICA TIONS F ACT OR Y S UPPLIED A CCESSORIES T HERMOST A T (CHT90-120) T wo-stage cool and two-stage heat thermostat with subbase, Manual changeover , Fan ON or AUT O. Note: A variety of thermostat con fi gurations can be used on this equipment based on the application needs.
12 SS-PCB50 P RODUCT S PECIFICA TIONS Q UALITY M AKES THE D IFFERENCE ! All of our systems are designed and manufactured with the same high-quality standards, regardless of size or ef fi ciency . W e have designed these units to signi fi cantly reduce the most frequent causes of product failure.
Ein wichtiger Punkt beim Kauf des Geräts Franklin Self-Contained Package Air Conditioner (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Franklin Self-Contained Package Air Conditioner noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Franklin Self-Contained Package Air Conditioner - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Franklin Self-Contained Package Air Conditioner reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Franklin Self-Contained Package Air Conditioner erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Franklin Self-Contained Package Air Conditioner besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Franklin Self-Contained Package Air Conditioner verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Franklin Self-Contained Package Air Conditioner. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Franklin Self-Contained Package Air Conditioner gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.