Benutzeranleitung / Produktwartung AT-9400 des Produzenten Allied Telesis
Zur Seite of 82
613-001273 Rev. A AT-9400 Series Gigabit Ethernet Switches Layer 2+ AT-9408LC/SP AT-9424T/GB AT-9424T/SP Basic Layer 3 AT-9424T AT-9424T/POE AT-9424Ts AT-9424Ts/XP AT-9448T/SP AT-9448Ts/XP ◆ Install.
Copyright © 2009 Allied Telesis, Inc. All rights reserved. No part o f this pub lication may be repro duced without prior wr itten permission from Al lied Telesis, Inc. Allied Telesis and the Allied Telesis logo are trademarks of Allied Tele sis, Incorporated.
3 Electrical Safety and Emissions S tandards This product meets the following standards. RFI Emissions FCC Class A, EN55022 Cl ass A, EN61000-3-2, EN61000-3-3, VCCI Class A, C-TICK, CE EMC (Immunity) EN55024 Electrical Safety EN60950 (TUV), UL 60950 ( C UL US ) U.
4 T ranslated Safety S tatements Important: The indicates that a translation of th e safety statement is available in a PDF document titled “Translated Safety St atements” ( 613-000990) poste d on the Allied Telesis website at www.alliedtelesis.
5 Preface .............. .............. ............ ........... ........... ........... ........... ............ .............. ........... ..... .............. ............ ........... ........... .... 7 Product Documentation8 Where to Go F irst ...
Contents 6 Implementation ......... ........... ........... .............. ............ ........... ........... ........... ........... ............ ............... .......... ........... .........40 AT-RPS3204 Redundant Power Su pply ... ............
7 Pr eface This guide contains the installat ion instructions for the AT-9400 Layer 2 + and Basic Layer 3 Gig abit Ethernet Sw itches. This preface contains the following sections: “Product Docu.
Preface 8 Product Documentation For overview information on the feat ures of the AT-9 400 Switches and the AT-S63 Management Sof tware, refer to: A T-S63 Management Sof tware Features Guide (PN 61.
AT-9400 Series Gigabi t Ethernet Switches Instal lation Guide 9 Where to Go First Allied Telesis recommends that you rea d Chapter 1, “Overview,” in the AT-S63 Management Software Features Guide before you b egin to manage the switch for the first time.
Preface 10 Safety Symbols Used in this Document This document uses the safety symbols defined in Table 1. T able 1. Safety Symbols Symbol Meaning Description Caution Performing or omi tting a specific action may result in equipment damage or loss of data.
AT-9400 Series Gigabi t Ethernet Switches Instal lation Guide 11 Contacting Allied Telesis This section provides Allied Telesis contact information for technica l support and for sales and corporate information. Online Support You can request technical support onli ne by accessing the Allie d Telesis Knowledge Base: www.
Preface 12.
13 Chapter 1 Overview The AT-9400 Switches are managed Gigab it Ethernet switches for Ethernet, Fast Ethernet, and Gigabit Ethernet networks. Th e AT-9400 Switches are divided into two groups: Lay.
Chapter 1: Ove rview 14 “Power Over Ethernet” on p age 39 “A T -RPS3204 Redundant Power Supply” on p age 41 “AC Power Connector” on p age 42.
AT-9400 Series Gigabi t Ethernet Switches Instal lation Guide 15 Descriptions The following sections des cribe the AT-9400 Swit ches. AT-9408LC/SP Switch The AT-9408LC/SP Layer 2 + Switch has the foll.
Chapter 1: Ove rview 16 AT-9424T/GB Switch The AT-9424T/GB Layer 2+ Switch has the following hardware fea tures: 24 10/100/1000Base-T port s T wo gigabit interface connector (GBIC) transceiver.
AT-9400 Series Gigabi t Ethernet Switches Instal lation Guide 17 AT-9424T/SP Switch The hardware features of the AT-942 4T/SP Layer 2+ Switch include: 24 10/100/1000Base-T ports T wo Gigabit E.
Chapter 1: Ove rview 18 AT-9424T Switch The AT-94 24T Basic Layer 3 Switch has these hardware featu res: 24 10/100/1000Base-T port s Four Gigabit Ethernet small form -factor pluggable (SFP) tr.
AT-9400 Series Gigabi t Ethernet Switches Instal lation Guide 19 AT-9424T/POE Switch The AT-9424T/POE Basic Layer 3 Switch has these hardware feature s: 24 10/100/1000Base-T p orts with Po wer ove.
Chapter 1: Ove rview 20 AT-9424Ts Switch The AT-9424Ts Basic Layer 3 Switch has these h ardware features: 24 10/100/1000Base-T port s Four Gigabit Ethernet small form -factor pluggable (SFP) t.
AT-9400 Series Gigabi t Ethernet Switches Instal lation Guide 21 AT-9424Ts/XP Switch The AT-9424Ts/XP Basic Layer 3 Switch has these hardware feature s: 24 10/100/1000Base-T ports Four Gigabit.
Chapter 1: Ove rview 22 AT-9448T/SP Switch The hardware features of the AT-9448T/ SP Basic Layer 3 Switch include: 48 10/100/1000Base-T port s Four Gigabit Ethernet SFP transceive r slots An RJ-45 style serial terminal port for local (out-of-ban d) management.
AT-9400 Series Gigabi t Ethernet Switches Instal lation Guide 23 AT-9448Ts/XP Switch The AT-9448Ts/XP Basic Layer 3 Switch has the following hardware features: 48 10/100/1000Base-T ports T wo .
Chapter 1: Ove rview 24 10/100/1000Base-T Twisted Pair Ports This section describes the twisted pair ports on the switches. (This section does not apply to the AT-9408LC/SP Switch.) Connector Type The ports are 8-pin RJ-45 connecto rs that use four pins at 10 or 100 Mbps and all eight pins at 1000 Mbps.
AT-9400 Series Gigabi t Ethernet Switches Instal lation Guide 25 Maximum Distance The ports have a maximum operating distance of 100 meters (328 feet).
Chapter 1: Ove rview 26 Fiber Optic Ports This section applies to ports 1 through 8 on t he AT-9408LC/SP Switch. Connector Type The ports feature L C-duplex connectors. Speed The ports have fixed speed of 1 000 Mbps (1000Base-SX). Maximum Distance and Cabling The ports have a maximum distance o f 275 meters (m) with 62.
AT-9400 Series Gigabi t Ethernet Switches Instal lation Guide 27 GBIC Transceiver Slots For interconnecting devices over large distances using fiber op tic cable, the AT-9424T/GB Switch has two slots on the front panel labe led 23 and 24 for optional fiber optic Gigabit Interface Converter (GBIC) Ethernet transceivers.
Chapter 1: Ove rview 28 SFP Transceiver Slots Several of the AT-9400 Switch es feature slots for optional Gigabit Ethernet SFP t ransceivers for interconnecting network devices ove r large distances using fiber optic cable. Wi th the exception o f the AT-9408LC/SP Switch, each SFP slot is paired with a twisted pair port.
AT-9400 Series Gigabi t Ethernet Switches Instal lation Guide 29 XFP Transceiver Slots Several AT-9400 Switches have slots for optiona l XFP 10 Gigabit Ethernet transceivers to conn ect high speed, 10 gigabit devices to the switch or create high speed backbone networks betwe en switches.
Chapter 1: Ove rview 30 Redundant Twisted Pair Ports Some AT-9400 Switches have two or four twisted pair ports t hat are paired with GBIC or SFP slots. The twisted pair ports ar e identified with the letter “R” for “Redundant” as part of their number on the front faceplate of the unit.
AT-9400 Series Gigabi t Ethernet Switches Instal lation Guide 31 Note These guidelines do not app ly to the SFP slots on the AT-9408LC/SP Switch and the XFP slots on the A T-9424T s/XP and AT-9448Ts/XP Switches.
Chapter 1: Ove rview 32 Compact Flash Card Slot The compact flash card slot featu red on many of the AT-9400 Switche s and shown in Figure 13 is used to store con figuration files and AT-S63 Management Software image files on a compact f lash card.
AT-9400 Series Gigabi t Ethernet Switches Instal lation Guide 33 Port LEDs The following sections describe the twisted pair and fiber optic port LEDs. 10/100/1000Base- T Twisted Pair Port LEDs A twisted pair port has two LEDs labeled L/A (link/activity) and D/C (duplex mode/collisions).
Chapter 1: Ove rview 34 Fiber Optic Port and Transceiver Slot LEDs The 1000Base-SX fiber optic ports on th e AT-9408LC/SP Switch and the GBIC and SFP transceiver slots have one LED. The LED is defined in Table 4. Each 10 Gigabit Ethernet transceiver slot on the AT-9424Ts/XP and AT-9448Ts/XP Switches has on e LED, defined in Table 5.
AT-9400 Series Gigabi t Ethernet Switches Instal lation Guide 35 System LEDs The system LEDs on the front panel display general status information, as described in Table 6. Table 6 System LEDs LED State Description FAULT or FLT Off Normal operation. Solid Red The switch or management so ftware has malfunctioned.
Chapter 1: Ove rview 36 Stack LEDs The Stack LEDs reflect the status of the two Sta ck ports on the optional AT-StackXG Stacking Module for the AT-9424Ts, AT-9424Ts/XP, and AT-9448Ts/XP Switches. The module, which does not have LEDs, is used to build a stack of up to five o r eight devices.
AT-9400 Series Gigabi t Ethernet Switches Instal lation Guide 37 Expansion Slot The expansion slot on the AT-9424 Ts, AT-9424Ts/XP, and AT-9 448Ts/XP Switches accommodates the optional AT -StackXG Stacking Module . The module is used to create stacks of up to five or eight switch es, depending on the model.
Chapter 1: Ove rview 38 Terminal Port The terminal port is used to establish a local (out-of-band) management session with the switch and configure the switch’s operating parameters. You establish a local management session with the switch by connecting a terminal or a personal computer wi th a terminal emulation pro gram to the port.
AT-9400 Series Gigabi t Ethernet Switches Instal lation Guide 39 Power Over Ethernet The following discussion applies only to the AT-9424T/POE Giga bit Ethernet Switch. The twisted pair ports on the AT-9424T/POE Switch fea ture Power over Ethernet (PoE).
Chapter 1: Ove rview 40 ports in any combination. A port connected to a network node that is not a powered device (that is, a device that receives its power from anot her power source) functions as a regular Ethernet port, without PoE. The PoE feature remain s enabled on the port but no power is delivered to the d evice.
AT-9400 Series Gigabi t Ethernet Switches Instal lation Guide 41 AT-RPS3204 Redundant Power Supply The RPS connector on the back pane l of the switch connects to the optional AT-RPS3204 redundan t power supply unit, shown in Figure 14. The unit can provide powe r to the switch in the event that the switch’s internal power supply fails.
Chapter 1: Ove rview 42 AC Power Connector The AT-9400 Switches have a single AC p ower supply socket with autoswitch AC inputs, on the back panel. To po wer the switch on or off, connect or disconnect the po wer cord. For the inp ut voltage range, refer to “Technical Specifications” on page 75.
43 Chapter 2 Installing the Switch This chapter contains the installation procedures for the switch. The chapter contains the following sections: “Reviewing Safety Precautions” on p age 44 .
Chapter 2: Inst alling the Switch 44 Reviewing Safety Precautions Please review the following safety pr ecautions before you begin to install the switch or any of its components.
AT-9400 Series Gigabi t Ethernet Switches Instal lation Guide 45 W arning: Opera ting T emperature. This product is designed for a maximum ambient temperature of 40° deg rees C. E7 All Countries: Install produ ct in accordance with local and National Electrical Codes.
Chapter 2: Inst alling the Switch 46 W arning: Reliable earthing of rack -mounted equipment should be maintained. Particular atte ntion should be given to supp ly connections other than direct conn ections to the branch circuits (e.g., use of power strip s).
AT-9400 Series Gigabi t Ethernet Switches Instal lation Guide 47 Selecting a Site Observe the following requirements when choo sing a site for the switch. If you plan to install th e switch in an equipment rack, che ck to be sure the rack is safely secured and will not tip over .
Chapter 2: Inst alling the Switch 48 Twisted Pair and Fiber Op tic Cable Specifications Twisted Pair Cable Specifications Table 9 lists the cabling specificati ons for the 10/100/1000Base-T twisted pair ports.
AT-9400 Series Gigabi t Ethernet Switches Instal lation Guide 49 Note The speed of a 10/100/1000 Base-T twisted pair port on the switch must be set to Auto -Negotiation, the default setting, if the port is to operate at 1000 Mbps. A 10/100/1000Base- T twisted pair port cannot be manually set to 1000 Mbps.
Chapter 2: Inst alling the Switch 50 Unpacking the Switch To unpack the switch, perform the following p rocedure: 1. Remove all components from the shipping pa ckage. Note Store the packaging material in a sa fe location. You must use the original shipping material if you need to re turn the unit to Allied Telesis.
AT-9400 Series Gigabi t Ethernet Switches Instal lation Guide 51 Installing the Power Cord R eta ining Clip (AC Switches Only) Perform the following procedure to inst all the power cord retaining clip on the AT-9400 Switch: 1. Locate the power cord retain ing clip, as shown in Figure 15.
Chapter 2: Inst alling the Switch 52 Installing the Switch in a Rack Perform the following procedure to install the switch in a standard 19-inch rack: Note Steps 1, 2, and 3 are optional. T hey remove the snap-on plastic feet from the bottom of a switch.
AT-9400 Series Gigabi t Ethernet Switches Instal lation Guide 53 5. Install the second rack-mount bracket on the other side of the switch using the four remaining screws. 6. Mount the switch in the 19-inch rack usin g standard screws (not provided), as shown in Figure 19.
Chapter 2: Inst alling the Switch 54 Installing Optional Transceivers Review the following guidelines before installing an option al GBIC, SFP or XFP transceiver in the switch: A transceiver can be hot-swapped. The switch can be powered on when you inst all a transceiver .
AT-9400 Series Gigabi t Ethernet Switches Instal lation Guide 55 Figure 20. Installing a GBIC Transceiver 3. Repeat this procedure to install an other GBIC transceiver o r go to “Cabling the Twisted Pair or Fiber Optic Ports” on page 59. For GBIC optical and cabling specif ications, consult the documentation shipped with the module.
Chapter 2: Inst alling the Switch 56 3. Position the transce iver with the label facing up. 4. Slide the transceiver into the sl ot until it clicks int o place.
AT-9400 Series Gigabi t Ethernet Switches Instal lation Guide 57 Installing an XFP Transceiver To install an XFP transce iver in the AT-9424Ts/XP or AT-9448Ts/XP Switch, perform the following procedure: 1. Remove the dust plug from a transceiver slot on the switch.
Chapter 2: Inst alling the Switch 58 5. Repeat this procedure to install a second XFP transceiver or go to “Cabling the Twisted Pair or Fiber Optic Ports” on page 59. For XFP optical and cabling specific ations, consult the do cumentatio n shipped with the module.
AT-9400 Series Gigabi t Ethernet Switches Instal lation Guide 59 Cabling the Twisted Pair or Fiber Optic Ports Observe the following guidelines when connecting a twisted pair or fiber optic cable to a port on the switch: The connector on the cab le should fit snugly into the port on the switch.
Chapter 2: Inst alling the Switch 60 Applying AC Power To apply AC power to the switch, pe rform the following procedure: 1. Position the power cord retaining clip in the up position, as shown in Figure 26. Figure 26. Power Cord Retaining Clip in the Up Position 2.
AT-9400 Series Gigabi t Ethernet Switches Instal lation Guide 61 3. Lower the power cord retaining clip to secure the cord to the switch, as shown in Figure 28. Figure 28. Securing the Power Co rd with the Retaining Clip 4. Connect the other end of the po wer cord to an appropr iate AC power outlet.
Chapter 2: Inst alling the Switch 62 Starting a Local Management Session The procedure in this section exp lains how to start a lo cal (out-of-band) management session using the RJ-45 termina l port on the switch. You can use a local management session to configure the switch’s operating parameters and view performance and error stat istics.
AT-9400 Series Gigabi t Ethernet Switches Instal lation Guide 63 Stop bits: 1 Flow control: None Note The port settings are for a DEC VT100 or ANSI terminal, or an equivalent terminal emulator program. 4. Press Enter. Y ou are prompted for a user name and password.
Chapter 2: Inst alling the Switch 64 Warranty Registration For warranty information, go to “Warranty” on page 11 or the Allied Telesis web site at www.
65 Chapter 3 T r oubleshooting This chapter contains informat ion about how to troubleshoot th e switch in the event a problem occurs. Note If you are unable to resolve a problem after following the instructions in this chapter, contact Allied Telesis Tech nical Support for assistance.
Chapter 3: Tro ubleshooting 66 Power LED is Off Check the PWR LED on the front of the switch. If t he LED is off, indicating that the unit is not receiving power, do the following: Make sure the power cord is securely connected to the p ower source and to the AC connector on the back p anel of the switch.
AT-9400 Series Gigabi t Ethernet Switches Instal lation Guide 67 Twisted Pair Port Link LED is Off When a twisted pair port on the switch is connected to a properly operating end node, the Link LED for the p ort should be on.
Chapter 3: Tro ubleshooting 68 Fiber Optic Port Link LED is Off When a fiber optic port on the switch is co nnected to a properly operating end node, the Link LED for the port should be on. If a Link LED is off, d o the following: V erify that the end node connected to the port is powered ON and is operating properly .
AT-9400 Series Gigabi t Ethernet Switches Instal lation Guide 69 Transceiver is Installed but the Status is “Not Present” If a GBIC, SFP, or XFP transceiver is installed in a transceiver slot but .
Chapter 3: Tro ubleshooting 70 System Fault LED is Blinking If the system FAULT LED is blinking, no action is requ ired. A blinkin g FAULT LED could indicate that a new version o f the management software is being downloaded to the swit ch or th e switch’s is updating the active boot configuration file.
AT-9400 Series Gigabi t Ethernet Switches Instal lation Guide 71 System Fault LED is Steadily On If the system FAULT LED is steadily on, a problem has occurred in the switch. Do the following: T ry resetting the switch by disconnecting and reconnecting the AC power cord.
Chapter 3: Tro ubleshooting 72 PoE Device is Not Receiving Power If a powered device is not receiving power fro m the AT-9424T/POE Switch, do the following: Check to be sure that the powered device is designed to rece ive power over pins 1, 2, 3, and 6 on the RJ-45 port.
AT-9400 Series Gigabi t Ethernet Switches Instal lation Guide 73 Cannot Establish a Local (Ou t-of-Band) Management Session If you are unable to establish a loca l (out-of-band) management session wit.
Chapter 3: Tro ubleshooting 74 Switch Functions Intermittently If the switch functions intermittently , check the system hardware status through the management interface : Note the current volt age for the power supp ly compared to th e optimum rating.
75 Appendix A T echnical Specifications Physical Specifications See Table 11 for information regarding the dimensions of the AT-9400 Series Switches. T able 1 1. A T -9400 Series Switch Dimensions A T -9400 Series Switch Dimensions (H x W x D) AT-9408LC/SP 4.
Appendix A: Technica l Specifications 76 See Table 12 for information re garding the weight of the AT-9 400 Series Switches. The recommended minimum clearance for ven tilation on all sides of an AT-9400 Series Switch is 10 cm (4.
AT-9400 Series Gigabi t Ethernet Switches Instal lation Guide 77 Power Specifications Input Voltage/Current.Freq (All Models e xcept AT-9424T/POE): AC100-240 VAC, 2.
Appendix A: Technica l Specifications 78 RJ-45 Twisted Pair Port Pinouts Figure 31 illustrates the pin layout of a n RJ-45 connector and port. Figure 31. RJ-45 Connector and Po rt Pin Layout Table 13 lists the pin signals when a p ort is operating in the MDI configuration at 10 or 100 Mbps.
AT-9400 Series Gigabi t Ethernet Switches Instal lation Guide 79 Table 15 lists the pin signals w hen a port operating at 1000 Mbps. T able 15. Pin Signals - 1000 Mbp s Pinout Pair 1 Pair 1 + 2 Pair 1.
Appendix A: Technica l Specifications 80 AT-9408LC/SP Switch 1000Bas e-SX Port Specifications Table 16 lists the operating specifications for ports 1 to 8 on the AT-9408LC/SP Switch. T able 16. 1000Base-SX Port S pecifications Property V alue T ransmitter Characteristics W avelength 850 nm Output Power Min: -9.
AT-9400 Series Gigabi t Ethernet Switches Instal lation Guide 81 RJ-45 Style Serial Terminal Port Pinouts Table 17 lists the pin signals on the RJ-45 style serial terminal port. RPS 21-pin D-combo Port and Connector Pinouts Figure 32 illustrates the pin layout of the RPS 21-p in D-combo port and connector.
Appendix A: Technica l Specifications 82 Table 18 lists the definitions fo r the RPS 21-pin D-combo port and connector pins. T able 18. RPS 21-pin D-combo Port and Connector Pin Definitions Pin Definition 1 Reserved 2 Fan 2 status 3 Fan 1 status 4R P S s t a t u s 5 Ground 6 Ground 7R P S s t a t u s 8 +12.
Ein wichtiger Punkt beim Kauf des Geräts Allied Telesis AT-9400 (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Allied Telesis AT-9400 noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Allied Telesis AT-9400 - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Allied Telesis AT-9400 reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Allied Telesis AT-9400 erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Allied Telesis AT-9400 besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Allied Telesis AT-9400 verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Allied Telesis AT-9400. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Allied Telesis AT-9400 gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.