Setup Guide 68-1377-01 Rev . E 09 10 IPL T Series IP Link Ethernet Control Interfaces IP Link ® (IPL T S Series, IPL T SFI244, IPL T CR48) IMPORT ANT : Refer to www .
Safety Pr ecautions This symbol is intended to alert the user of important operating and maintenance (servicing) instructions in the literature provided with the equipment. This symbol is intended to alert the user of the pr esence of uninsulated dangerous voltage within the product’ s enclosure that may present a risk of electric shock.
FCC Class A Notice This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. Operation is subject to the following two conditions: 1. This device may not cause harmful interference.
.
IPL T Series • Contents v Contents Introduction ....................................... 1 About this Guide ................................ 1 IPL T Series Products .......................... 1 IPL T S Series ................................... 1 IPL T SFI244 .
IPL T Series • Contents vi.
IPL T Series • Introduction 1 Intr oduction This section gives an overview of the setup guide and describes the IPL T Series IP Link ® Ethernet Control Interfaces and the features of these products.
2 IPL T Series • Introduction IPL T S2 Features of the IPL T S2 include: 12 VDC, 1 A desktop power supply RJ-45 Ethernet receptacle T wo (2) 9-pin D RS-232, RS-422, or RS-485 serial ports - or - T wo (2) 3.
3 IPL T Series • Introduction COM 3 LAN UID# 093012052 POWER 12V .5A MAX COM 2 COM 1 COM 2 Lighting Control Ethernet RS-232 RS-232 D VD Laptop VCR Remote User Control & Administrator Monitoring .
4 IPL T Series • Introduction IPL T SFI244 Features of the IPL T SFI244 include: 12 VDC, 1 A desktop power supply RJ-45 Ethernet receptacle T wo (2) RS-232 serial ports .
5 IPL T Series • Introduction Blinds LAN POWER 12V 0.5A INPUT 2 1 3 4 5 6 7 8 1 2 3 4 Extron IPL T CR48 Ethernet Control Interface Projector Lighting System Screen Control Projector Lift Control TCP/IP Network GlobalView er ® A /V Resource Management and Re mote Con tro l Application Figure 3.
6 IPL T Series • Introduction Figure 4. Global Configurator Application Scr een Using GC you can configure a single room controller or create a Web-based remote monitoring system for hundreds of A/V devices in multiple locations. Y ou can configure an IPL T controller using GC without having the device physically connected to the A/V network.
7 IPL T Series • Introduction System Requirements The miminum system requirements for the PC on which you install Global Configurator include: Intel ® Pentium ® III, 1 GHz processor Microsoft ® Windows ® XP SP2, Windows Vista ® , or Windows 7 Microsoft Internet Explorer ® 6.
8 IPL T Series • Introduction T o install Global Configurator from an Extron Software Products Disk if Autorun is not enabled on your PC: 1. Insert the Extron Software Products Disk into the disk drive of your PC. 2. From the Windows desktop, open My Computer and select the appropriate disk drive.
IPL T Series • Setup 9 Setup This section describes the hardware setup and configuration of the IPL T Series controllers. T opics that are covered include: Front Panel Featur es Rea.
10 IPL T Series • Setup e LINK LED — A green LED lights to indicate that the unit is connected to an active network. f ACT LED — A yellow LED lights to indicate that data is being sent or received.
11 IPL T Series • Setup IPL T CR48 4 2 3 1 RELA Y 8 6 7 5 IPL T CR48 R 4 2 3 1 INPUT 100 LINK ACT 7 6 1 3 2 4 5 a Power LED — A green LED lights to indicate that the unit is receiving power . b Reset button — Recessed multiple function Reset button.
12 IPL T Series • Setup IPL T SFI244 COM1 COM2 LAN POWER 12V .5A MAX FLEX I/O 2 1 3 4 1 IR 2 3 4 TX RX TX RX G S G S G S G S MAC: 00-05-A6-XX-XX-XX S/N: IPL T SFI244 6 2 1 5 3 4 a Power connection — Connect the supplied 12 VDC power supply b LAN port — RJ-45 receptacle for network connection c COM ports — 3.
13 IPL T Series • Setup Resetting the Controller There are five reset modes (numbered 1, 2, 3, 4, 5 for the sake of comparison with other Extron IPL products) available by using the Reset button ( b ) on the front panel. The Reset button is recessed, so use of a pointed stylus, ballpoint pen, or Extron T weeker is suggested.
14 IPL T Series • Setup Connections and Wiring Power Connection T o connect the power supply: 1. Insert the 2-pole captive screw connector into the power supply receptacle on the rear panel of the controller . SECTION A–A Ridges Smooth Po wer Supply Output Cord A A 3/16” (5 mm) Max.
15 IPL T Series • Setup A cable that is wired as T568A at one end and T568B at the other (Tx and Rx pairs reversed) is a "crosso ver" cable. A cable wired the same at both ends is called a "straight-through" cable, because no pin/pair assignments are swapped.
16 IPL T Series • Setup Captive screw connector The IPL T S2, IPL T S6, and IPL T SFI244 have COM ports with captive screw connectors. The two COM ports with captive screw connectors on the IPL T S2 are common to the two 9-pin D connectors. Only one connector can be used for each COM port.
17 IPL T Series • Setup IR Ports The IPL T SFI244 has four IR ports for infrared device connection. Y ou can connect IR emitters or a wired IR control port of another device to send IR signals (with or without carrier frequencies) to display or source devices.
18 IPL T Series • Setup Flex I/O Ports The IPL T SFI244 has four Flex I/O ports that can be configured as digital inputs, digital outputs, or analog inputs. When configured as digital inputs, the Flex I/O ports can connect to switches and sensors.
19 IPL T Series • Setup Then, you must change the default settings of the controller (IP address, subnet mask, and [optional] administrator name and password) in order to use the controller on an intranet (LAN) or on the Internet.
20 IPL T Series • Setup 5. Execute a ping command by typing ping followed by a space and the new IP address at the command prompt. For example: ping 10.13.170.15 After issuing this command, the controller changes to the new address and starts responding to the ping requests, as described.
21 IPL T Series • Setup.
USA, Canada, South America, and Central America: Extron USA 1001 East Ball Road Anaheim, CA 92805 U.S.A. Europe, Africa, and the Middle East: Extron Europe Hanzeboulevard 10 3825 PH Amersfoort The Netherlands Asia: Extron Asia 135 Joo Seng Road #04-01 PM Industrial Bldg.
Extron USA - West Headquarters + 800.633.9876 Inside USA/Canada Only +1.714.491.1500 +1.714.491.1517 FAX Extron USA - East +800.633.9876 Inside USA/Canada Only +1.919.863.1794 +1.919.863.1797 FAX Extron Europe +800.3987.6673 Inside Europe Only +31.33.
Ein wichtiger Punkt beim Kauf des Geräts Extron electronic IPL T SFI244 (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Extron electronic IPL T SFI244 noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Extron electronic IPL T SFI244 - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Extron electronic IPL T SFI244 reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Extron electronic IPL T SFI244 erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Extron electronic IPL T SFI244 besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Extron electronic IPL T SFI244 verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Extron electronic IPL T SFI244. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Extron electronic IPL T SFI244 gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.