SHERWOOD INDUSTRIES IS AN ENVI RONMENTALLY RESPO NSIBLE COMPANY THIS MANUAL IS PRINTED ON RECYCLED PAPER EG 40 B Vented By SHERWOOD INDUSTRIES LTD. OWNERS MANUAL WHAT TO DO IF YOU SMELL GAS • Open windows • Do not try to light any appliance. • Do not touch any electrical switch; do not use any phone in your building.
SAFETY PRECAUTIONS FOR SAFE INSTALLATION AND OPERATION OF YOUR "ENVIROGAS" STOVE, PLEASE, CAREFULLY READ THE FOLLOWING INFORMATION: GENERAL • Installation and repair should be do ne by a qualified service person. The appliance should be inspected before u se and at once least annually by a qualified service person.
3 TABLE OF CONTENTS Safety Precautions 2 Code Approvals 3 Deciding where to locate y our stove 4 Venting 6 Installation of Log Sets and Embers 8 Operating Instructions 9 Maintenance and Technica l 10 .
DECIDING WHERE TO LOCATE YOUR STOVE DIMENSIONS: FIG. 1 Front Width: 25"/ 63 cm Rear Width: 25"/ 63 cm Height: 29"/ 74 cm* Depth 21"/ 53 cm ( *not including vent coupling ) Shipping Weight: 256 lbs/116 kg CLEARANCES: A. Side wall to stove 12"/ 30cm B.
VENT TERMINAL CLEARANCES A= Clearance above grade, verandah, porch, deck, or [balcony (*12 inches (30cm ) minimum] B= Clearance to window or door that ma y be opened [*12 inches (30cm) minimu m] C= Cl.
VENTING This model must have a vent opening in the r ear of the unit. C onfirm this and als o check that the label on the right side pa nel door states "Vented Room Heater". WARNING: THIS APPLIANCE HAS BEEN DESIGNED TO OPERATE BY DRAWING COMBUSTION AIR AND DILUTION AI R FROM THE ROOM.
A. USING AN EXISTING CHIMNEY • Measure the height of the chimney beforehand and purchase the appropriate kit. Never attempt to over stretch a flexible liner to accommodate the height of the chimney. • Any flue damper must be removed or locked perman ently in the open position.
INSTALLATION OF LOG SET and EMBERS INSTALLING THE GLOWING EMBE RS A bag of ceramic fiber embers is provide d for use on the front burner ember tray. CAUTION: Use only the type of ember material supp lied wi th this appliance. Due to the irregular size of the ember material there may be more than requi red.
OPERATING INSTRUCTIONS FOR YOUR SAFETY READ BEFORE OPERATIN G WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCT IONS EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE , PERSONAL INJURY OR LOSS OF LIFE. A) This applianc e is equipped with a pilot, which must be lit by hand by following these instructions exactly.
MAINTENANCE AND TECHNICAL Annually check to ensure that your Vent system is clear. Periodically check the pilot and burner. Che ck to see that all the burner port s are clean and clear. Check the pilot head for blockag e. Check to ensure the pilot flame is blue with small yellow tips.
TROUBLE SHOOTING Problem Possible Cause Solution Spark will not light the pilot after repeated pressing of sp ark igniter Defective piezo igniter Check connection s to igniter -If igniter connections .
GAS LINE CONNECTION ORIFICE SIZES, PRESSURE AND BTU’S NATURAL GAS PROPANE GAS FRONT BURNER #48 (1.93mm) #55 (1.32mm) REAR BURNER #41 (2.49 mm) #54 (1.40 mm) Manifold pressure. 3.8” wc (.95 kPa) 11” wc (2.74 kPa) Min. Manifold pressure. 1.1” wc (.
ELECTRICAL The ENVIROGAS EG 40.FS.BV. will operate with no external po wer supply. These models have a Milli volt gas control which uses the pilot flame to generate enoug h electricity to operate the main burner.
PARTS AND ACCESSORIES Service Parts available from your local Envirogas Dealer Burner Control Assembly Natural Gas Pilot Assembly Propane Pilot Assembly Door Bolt Relief Door Gasket Regulating Valve P.
• There is a separate air shutter for each burner. • Remove one screw from the cover pl ate located below the ash shelf. Loosen the other scre w (do not remove) swing the cover plate out of the way and tighten screw do wn to hold it in place. • With along screwdriver rotate spring clips to open or close the shutter to the desired setting.
16 WARRANTY Sherwood Industries Ltd. offers a *Lifetime Wa rranty on this gas produc t. The lifetime warranty covers the appliance for a period of seven years fro m the date of installation.
17 PARTS LIST EC-001 120 ° F CERAMIC TEMP SENSOR EG40-081 UPPER GOLD BARS (SET of 2) EC-003 300 ° F CERAMIC SPILL SWITCH EG40-084 FS LOWER GOLD BAR EC-006 S.
18 EG 40 DOOR AND BURNER ASSEMBLIES EXPLODED Page 1 of 2 JULY 2001 GLASS EXTRUSIONS DOOR LATCH STRIP HINGE SET OF 2 EG40-302 PAINTED DOOR ASSEMBLY WITH GLASS (A + B) EG40-073 GOLD DOOR ASSEMBLY WITH G.
19 FS UPPER BAR SET EG40-081 EG 40 FREESTANDING BODY (chassis) EXPLODED. Page 2 of 2 JULY 2001 EG 40 EMBLEM FS PEDESTAL DOOR EG40-135 FS ASH SILL EG40-213 FS LOWER BAR EG40-084 CONVECTION AIR DEFLECTO.
INSTALLATION DATA SHEET The following information must be recorded by the in staller for wa rranty purposes and future reference. Model: EG 40 20 Name of Dealer: _______________ ____________ _________.
Ein wichtiger Punkt beim Kauf des Geräts Enviro EG 40 B (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Enviro EG 40 B noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Enviro EG 40 B - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Enviro EG 40 B reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Enviro EG 40 B erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Enviro EG 40 B besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Enviro EG 40 B verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Enviro EG 40 B. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Enviro EG 40 B gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.