Benutzeranleitung / Produktwartung 50-1096 des Produzenten Enviro
Zur Seite of 31
SHERWOOD INDUSTRIES IS AN ENVIRONMENT ALL Y RESPONSIBLE COMP ANY . THIS MANUAL IS PRINTED ON RECYCLED P APER. BY: SHERWOOD INDUSTRIES LTD O WNER ’S MANU AL PLEASE KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE This appliance is only for use with the type of gas indicated on the rating plate.
FOR SAFE INST ALLA TION AND OPERA TION OF Y OUR “ENVIR O” HEA TER, PLEASE CAREFULL Y READ THE FOLLO WING INFORMA TION: • All ENVIRO gas-red appliances must be installed in accor dance with their instructions. Carefully read all the instructions in this manual rst.
T able of Contents 3 Safety Precautions.....................................................................................................2 T able of Contents...........................................................................................
DIRECT VENT: This type is identied by the sufx DV . This appliance draws all of its air for combustion from outside the dwelling, through a specially designed vent pipe system. This appliance has been tested and approved f or installations from 0 feet to 4500 feet (1372 m) abo ve sea level.
Specific a tions R ATING L ABEL L OCATION : The rating label is located under the control panel and is attached to a rectangular metal sheet that is chained to the replace.
6 Specific a tions 15 1 / 16 " (383 mm) 30 1 / 2 " (775 mm) With Trim 33 3 / 16 " (343 mm) Without Trim 33" (338 mm) 20 5 / 8 " (523 mm) 22 3 / 4 " (577 mm) 22 11 / 16 &q.
7 WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY A FIRE OR EXPLOSION MAY RESULT, CAUSING PROPERTY DAMAGE, PERSONAL INJURY OF LOSS OF LIFE. P ILOT L IGHTING I NSTRUCTIONS : Figure 3. Lighting instruction label. 1. STOP! Read the safety information above on this label.
8 Oper a ting Instructions For Your Safety, Read Safety Precautions And Lighting Instructions Before Operating A) Make sure the pilot is lit. B) T urn gas control knob COUNTER CLOCKWISE to ON. C) Flip the burner switch to ON. D) T urn HI/LO knob to the desired ame height.
9 Maintenance And Ser vice Warning: F ailure to position the parts in accordance with this manual, or f ailure to use only parts specically approved with this appliance, ma y result in property damage or personal injury . At least once a year , run through the following procedures to ensure the system is clean and working properly .
F UEL C ONVERSION : Warning: This conversion kit shall be installed by a qualied service agency in accordance with the manufacturer’s instructions and all applicable codes and requirements of the authority having jurisdiction.
Initial Inst alla tion WARNING: Operation of this heater when not connected to a properly installed and maintained venting system can result in carbon monoxide (CO) poisoning and possible death. C LEARANCES TO C OMBUSTIBLES : Maintain sufcient clearances f or operation, service and maintenance.
12 Initial Inst alla tion Check draft with a match or smoke in a " (6 mm) tube located here. M INIMUM F IREPLACE S IZE : Description of Fireplace Dimension Direct V ent B-V ent Width At Back 2.
Initial Inst alla tion QUALIFIED INST ALLERS ONL Y D IRECT V ENT M ODEL : WARNING: This appliance has been designed to draw room air for proper heat circulation from the sides of the unit. Blocking or modifying the louvers in any way can create hazardous situations.
14 In s t al l s e a le d t h ro a t c o nn e c to r o r flashing to prevent leakage of room air up through chimney . DV O n l y: B e f o re i n s t al l i n g ve n t liners, mark each liner on both ends to designate which is the intake and the exhaust.
15 Initial Inst alla tion QUALIFIED INST ALLERS ONL Y E LECTRICAL R EQUIREMENTS : F an Control Black White White Black Green/Y ellow Green Black Power Cord 120V AC F AN 120 o F (49 o C) T emperature Sensor CNT2 CNT3 CNT1 CNT4 The fan is thermostatically controlled and it will not oper ate if the appliance is cold.
Initial Inst alla tion QUALIFIED INST ALLERS ONL Y G AS L INE C ONNECTION : Warning: Only persons licensed to work with gas piping may make the necessary gas connections to this appliance.
17 Initial Inst alla tion QUALIFIED INST ALLERS ONL Y C ONVERTING A D IRECT V ENT F IREPLACE T O A B-V ENT F IREPLACE : Direct V ent Connector Assembly Fresh Air Inlet Covers 1. Remove the Direct V ent chimney connector assembly by taking out the two (2) T -20 screws at the front of the unit.
Second ar y Inst alla tion QUALIFIED INST ALLERS ONL Y R EPLACING THE B LOWER : 1. T urn the unit off and allow the unit to cool completely . 2. Remove the f ascia or louvers, open the door (see “ D OOR R EMO VAL ”) , and remo ve the log set. 3. Remove the log support tray by lifting the back of the tray up and pul l it out from under the lip.
19 Second ar y Inst alla tion Figure 23: Filler panel with trim installation. D OOR R EMOVAL : Figure 19: Top bolts for glass door. Figure 20: Bottom hooks for glass door. Open the door by removing the two (2) 5 / 16 ’’ bolts located at the top outside corners of the glass frame (see Figure 19).
Second ar y Inst alla tion L OG S ET AND E MBER I NSTALLATION : NOTE: The logs are fragile and should be handled gently. The placement of the logs is not arbitr ary . If they are positioned incorrectly , the ames can be “pinched” and will not burn correctly .
21 Second ar y Inst alla tion Figure 27. Third Stage Log Set Installation. Figure 29. Fifth Stage Log Set Installation. Figure 28. Fourth Stage Log Set Installation. Figure 28: Once the logs are in position the provided rock wool can be placed irregularly in front of the burner .
Second ar y Inst alla tion Figure 30. Sienna complete log set-up with embers burning. NO TE: While the glass is still removed, it is recommended that the gas line be purged by lighting the pilot. When lighting the replace for the rst time since the log set and embers have been installed/replaced, watch for ignition at ALL the burner ports.
23 Second ar y Inst alla tion R EMOVING T HE B RICK P ANEL : The brick panel set is fragile, handle with extreme care. The brick panel set comes pre-installed. The centre and top panel are the only panels that need to be removed if the complete gas and electrical tray assembly must be removed.
T rouble Shooting Problem Possible Cause Solution Spark will not arc to the pilot after repeatedly pressing the spark ignitor Defective piezo ignitor • Check connections to ignitor . • If ignitor connections are good but no spark, replace ignitor .
P ar ts List- Unit Components Reference Number Part Description Part Number 1 120°F Ceramic Fan T emperature Sensor EC-001 2 300°F (149°C) Manual Reset Spill Switch (Normally Closed) EC-003 3 S.
26 P ar ts Diagr am - Components SIENNA - Components October 2004 .
27 P ar ts Diagr am - Burner SIENNA - Burner October 2004 .
P ar ts List - Options Reference Number Option Description Part Number 1A The Cottage T rim Kit - Gold 50-548 1A The Cottage T rim Kit - Pewter 50-549 1A The Cottage T rim Kit - Antique Copper 50-550 .
29 P ar ts Diagr am - Options SIENNA - Options October 2004 .
30 W arr anty Sherwood Industries Ltd. offers a Limited Lifetime W arrant y on this gas product. This Limited Lifetime W arrant y covers the appliance for a period of seven years from the date of installation. This warrant y applies only to the original owner in the original location.
Inst alla tion Da t a Sheet The following information must be recorded by the installer for w arranty purposes and f uture reference. NAME OF OWNER: _________________________________________ ADDRESS: .
Ein wichtiger Punkt beim Kauf des Geräts Enviro 50-1096 (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Enviro 50-1096 noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Enviro 50-1096 - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Enviro 50-1096 reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Enviro 50-1096 erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Enviro 50-1096 besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Enviro 50-1096 verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Enviro 50-1096. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Enviro 50-1096 gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.