Benutzeranleitung / Produktwartung 8922H des Produzenten Alfred Dunhill
Zur Seite of 19
1 Projector C Models: 8755K, 8922H, 8923H C User's Manual (detailed) Operating Guide – T echnical Resolution (H x V) H. frequency (kHz) V . frequency (Hz) Rating Signal mode 720 x 400 37.9 85.0 VESA TEXT 640 x 480 31.5 59.9 VESA VGA (60Hz) 640 x 480 37.
2 Initial set signals Initial set signals The following signals are used for the initial settings. The signal timing of some PC models may be different.
3 A COMPUTER IN1, B COMPUTER IN2, C MONITOR OUT D-sub 15pin mini shrink jack <Computer signal> • Video signal: RGB separate, Analog, 0.7Vp-p, 75Ω terminated (positive) • H/V . sync. signal: TTL level (positive/negative) • Composite sync. signal: TTL level <Component video signal> • Video signal: - Y , Analog, 1.
4 G S-VIDEO Mini DIN 4pin jack • System: NTSC, P AL, SECAM, P AL-M, P AL-N, NTSC4.43, P AL (60Hz) Pin Signal 1 Color signal 0.286Vp-p (NTSC, burst), 75Ω terminator Color signal 0.
5 Connection to the por ts (continued) I AUDIO IN1, J AUDIO IN2 Ø3.5 stereo mini jack • 200 mV rms 47kΩ terminator AUDIO IN3 K R, L L RCA jack x2 • 200 mV rms 47kΩ terminator AUDIO OUT M R, N.
6 Connection to the por ts (continued) O USB USB B type jack Pin Signal 1 +5V 2 - Data 3 + Data 4 Ground 4 3 1 2 P CONTROL D-sub 9pin plug • About the details of RS-232C communication, please refer to the following page.
7 T o input component video signal to COMPUTER IN ports ex. 㪭㫀㪻㪼㫆 㪩 㪙 㪞 㪘㫌㪻㫀㫆㩷㪣 㪘㫌㪻㫀㫆㩷㪩 Y C B /P B C R /P R COMPONEN T VIDEO OUT Connection to the por ts (continued) T o input SCART RGB signal; ex. T o input SCART RGB signal to the projector , use a SCART to RCA cable.
8 CD (1) (1) − RD(2) (2) RD TD (3) (3) TD DTR (4) (4) − GND (5) (5) GND DSR (6) (6) − RTS (7) (7) R TS DTS (8) (8) CTS RI (9) (9) − RS-232C Communication RS-232C Communication When the projector connects to the computer by RS-232C communication, the projector can be controlled with RS-232C commands from the computer .
9 RS-232C Communication (continued) Communication settings 1. Protocol 19200bps,8N1 2. Command for mat ("h" shows hexadecimal) Byte Number 0 1 2 3 4 5 6 7 8 9 10 11 12 Command Action Header .
10 Names Operation T ype Header Command Data CRC Action T ype Setting Code Power Set T urn off BE EF 03 06 00 2A D3 01 00 00 60 00 00 Turn on BE EF 03 06 00 BA D2 01 00 00 60 01 00 Get BE EF 03 06 00 .
11 Names Operation T ype Header Command Data CRC Action T ype Setting Code GAMMA Set 1 DEFAUL T BE EF 03 06 00 07 E9 01 00 A1 30 20 00 1 CUSTOM BE EF 03 06 00 07 FD 01 00 A1 30 10 00 2 DEF AULT BE EF .
12 Names Operation T ype Header Command Data CRC Action T ype Setting Code User Gamma Point 8 Get BE EF 03 06 00 7C FF 02 00 97 30 00 00 Increment BE EF 03 06 00 1A FF 04 00 97 30 00 00 Decrement BE E.
13 Names Operation T ype Header Command Data CRC Action T ype Setting Code COLOR Get BE EF 03 06 00 B5 72 02 00 02 22 00 00 Increment BE EF 03 06 00 D3 72 04 00 02 22 00 00 Decrement BE EF 03 06 00 02.
14 Names Operation Type Header Command Data CRC Action T ype Setting Code H SIZE Get BE EF 03 06 00 B5 82 02 00 02 21 00 00 Increment BE EF 03 06 00 D3 82 04 00 02 21 00 00 Decrement BE EF 03 06 00 02.
15 Names Operation Type Header Command Data CRC Action T ype Setting Code FRAME LOCK – COMPUTER IN1 Set OFF BE EF 03 06 00 3B C2 01 00 50 30 00 00 ON BE EF 03 06 00 AB C3 01 00 50 30 01 00 Get BE EF.
16 Names Operation T ype Header Command Data CRC Action T ype Setting Code VOLUME - COMPUTER IN2 Get BE EF 03 06 00 FD CD 02 00 64 20 00 00 Increment BE EF 03 06 00 9B CD 04 00 64 20 00 00 Decrement B.
17 Names Operation T ype Header Command Data CRC Action T ype Setting Code AUDIO OUT ST ANDBY Set AUDIO IN1 BE EF 03 06 00 7A DF 01 00 3F 20 01 00 AUDIO IN2 BE EF 03 06 00 8A DF 01 00 3F 20 02 00 AUDI.
18 Names Operation T ype Header Command Data CRC Action T ype Setting Code BLANK Set MyScreen BE EF 03 06 00 FB CA 01 00 00 30 20 00 ORIGINAL BE EF 03 06 00 FB E2 01 00 00 30 40 00 BLUE BE EF 03 06 00.
19 Names Operation T ype Header Command Data CRC Action T ype Setting Code AUTO OFF Get BE EF 03 06 00 08 86 02 00 10 31 00 00 Increment BE EF 03 06 00 6E 86 04 00 10 31 00 00 Decrement BE EF 03 06 00.
Ein wichtiger Punkt beim Kauf des Geräts Alfred Dunhill 8922H (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Alfred Dunhill 8922H noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Alfred Dunhill 8922H - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Alfred Dunhill 8922H reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Alfred Dunhill 8922H erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Alfred Dunhill 8922H besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Alfred Dunhill 8922H verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Alfred Dunhill 8922H. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Alfred Dunhill 8922H gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.