T echnical Guide DAN-LIQ-T urbine Meter-TG-0807 August 2007 www .daniel.com Daniel ® Liquid T urbine Flow Meter T echnical Guide Liquid T urbine Flow Met ers.
.
T echnical Guide DAN-LIQ-T urbine Meter-TG-0807 August 2007 T ABLE OF CONTENTS T urbine Meter Parameters ............................................................................................................................. 1 The Daniel Series 1200 and 1500 Liquid T urbine Flow Meter Systems .
T echnical Guide DAN-LIQ-T urbine Meter-TG-0807 August 2007 Page 1 +0.15% –0.15% +0.02% –0.02% TURBINE METER P ARAMETERS These ve terms are the most widely discussed parameters of turbine meter applications. Linearity is the measure of variation in signal output across the nominal ow range of the meter .
T echnical Guide DAN-LIQ-T urbine Meter-TG-0807 August 2007 Page 2 THE DANIEL ® SERIES 1200 AND 1500 LIQUID TURBINE FLOW METER SYSTEMS The Daniel Series 1200 and 1500 Liquid T urbine Flow Meter Systems combine turbine meters and electronic instrumentation to measure volumetric total ow and/or ow rate.
T echnical Guide DAN-LIQ-T urbine Meter-TG-0807 August 2007 Page 3 Daniel ® V alves In Load Rack Duty TURBINE METER THEOR Y The basic theory behind Daniel’s electronic liquid turbine meters is relatively simple.
T echnical Guide DAN-LIQ-T urbine Meter-TG-0807 August 2007 Page 4 P A TENTED* FLOA TING ROT OR Flowing uid enters the turbine through the forward suspension. When it encounters the sharp angle of the cone, the stream is deected outward, increasing in velocity and causing a slight static pressure drop.
T echnical Guide DAN-LIQ-T urbine Meter-TG-0807 August 2007 Page 5 Surge And Pressure Relief V alves MAGNETIC PICKOFF OF ROTOR VELOCITY The angular velocity of the turbine rotor is taken through the turbine meter wall by means of a magnetic pickoff.
T echnical Guide DAN-LIQ-T urbine Meter-TG-0807 August 2007 Page 6 TURBINE METER ROTOR AND BEARING DESIGN The primary differences in turbine meter technology are in the design of the rotor and bearings. The rotor is an assembly of up to twelve (in some designs this number is greater) blades locked into a hub, which rotates on a bearing or bearings.
T echnical Guide DAN-LIQ-T urbine Meter-TG-0807 August 2007 Page 7 RIMMED ROTORS FOR HIGHER RESOLUTION In the larger diameter Daniel Series 1500 Liquid T urbine Flow Meter (normally above 6” in line size), the resolution provided by a blade-type motor may be improved by the use of a rimmed (or shrouded) rotor .
T echnical Guide DAN-LIQ-T urbine Meter-TG-0807 August 2007 Page 8 DANIEL ® SERIES 1200 LIQUID TURBINE FLOW METER Daniel Series 1200 Liquid T urbine Flow Meters are designed specically for load rack service where a vital characteristic is repeatability .
T echnical Guide DAN-LIQ-T urbine Meter-TG-0807 August 2007 Page 9 DANIEL ® SERIES 1200 LIQUID TURBINE FLOW METER DESIGN FEA TURES The following data is applicable for Daniel Series 1200 Liquid T urbine Flow Meter calibrated on mineral spirits.
T echnical Guide DAN-LIQ-T urbine Meter-TG-0807 August 2007 Page 10 DANIEL ® SERIES 1200 LIQUID TURBINE FLOW METER MA TERIALS OF CONSTRUCTION Standard Optional Body/Flanges 1” and 1.
T echnical Guide DAN-LIQ-T urbine Meter-TG-0807 August 2007 Page 1 1 DANIEL ® SERIES 1500 LIQUID TURBINE FLOW METER The Daniel Series 1500 Liquid T urbine Flow Meter is designed for applications requiring rugged dependability with high accuracy and throughput.
T echnical Guide DAN-LIQ-T urbine Meter-TG-0807 August 2007 Page 12 The deployment of this high resolution rotor in each of the sizes available gives a nominal K-factor twice that of the standard meter and allows for proving with a smaller size prover .
T echnical Guide DAN-LIQ-T urbine Meter-TG-0807 August 2007 Page 13 Item Standard Optional Optional Meter body and anges 304 Standard 1” and 1.5” NA 316 SS CS Standard 2” and up 304 SS 316 SS.
T echnical Guide DAN-LIQ-T urbine Meter-TG-0807 August 2007 Page 14 RANGEABILITY OF LIQUID TURBINE FLOW METERS The ow ranges indicated in the previous tables show a nominal ow range -- with a tu.
T echnical Guide DAN-LIQ-T urbine Meter-TG-0807 August 2007 Page 15 DANIEL ® SERIES 1500 LIQUID TURBINE FLOW METER SPECIFIC GRA VITY ADJUSTMENTS S.G. = 1 ( .7 to 1 ) Meter Size Minimum Linear Maximum Linear BBL/Hr M 3 /Hr USGPM BBL/Hr M 3 /Hr USGPM 1 10 1.
T echnical Guide DAN-LIQ-T urbine Meter-TG-0807 August 2007 Page 16 METER PERFORMANCE IN HIGH VISCOSITY LIQUIDS Increases in viscosity of the measured liquid will reduce the rangeability of the ow meter . Generally , the minimum ow rate of the meter will have to be increased to maintain the linearity rating of the meter .
T echnical Guide DAN-LIQ-T urbine Meter-TG-0807 August 2007 Page 17 INST ALLA TION AND OPERA TING RECOMMENDA TIONS For a turbine meter to perform without increased uncertainty and in a repeatable and accurate manner , the owing stream must be free of rotational components.
T echnical Guide DAN-LIQ-T urbine Meter-TG-0807 August 2007 Page 18 Figure 14 - Effects of Back Pressure In some circumstances, the use of a Flow Conditioning Plate (FCP) is possible.
T echnical Guide DAN-LIQ-T urbine Meter-TG-0807 August 2007 Page 19 DUAL CHANNEL PREAMP TERMINAL IDENTIFICA TION CUSTOMER CONNECTIONS BLACK OR RED PICKOFF PICKOFF WHITE WHITE CHANNEL B CHANNEL A BLACK OR RED T U P T U O B .
.
Emerson Process Management Daniel Measurement and Control, Inc. World Area Headquarters Houston, T exas, USA T : 713 -46 7-6 00 0, F : 71 3-8 27- 38 80 US A T oll Fre e 1- 888 -F LOW -0 01 ww w .d an iel .co m Calgary , Alberta, Canada T : 403 -27 9-1 87 9, F : 40 3-2 36- 13 37 Al ber ta T o ll F ree 1-8 00- 24 2-3 197 Sa les @Da ni eli nd- ca n.
Ein wichtiger Punkt beim Kauf des Geräts Emerson TG-0807 (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Emerson TG-0807 noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Emerson TG-0807 - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Emerson TG-0807 reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Emerson TG-0807 erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Emerson TG-0807 besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Emerson TG-0807 verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Emerson TG-0807. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Emerson TG-0807 gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.