Reference Manual 00809-0100-4952, Rev BA February 2014 R osemount Pipe C lamp Sensor.
.
i Reference Manu al 00809-0100-4952, Rev BA Title Page February 2014 The R osemount 0085 Pipe Clamp Sensor NO TICE Re ad this manual be fore w orkin g with the produc t. For pe rsonal and system sa fety , and for optimum product performance , make sure you thoroughly understand the conte nts befo re installing, using, or maintaining th is produc t.
.
iii Reference Manu al 00809-0100-4952, Rev BA Table of Contents February 2014 Ta b l e o f Co n t e n t s 1 Section 1: Introduction 1.1 Using this m anual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
.
1 Reference Manu al 00809-0100-4952, Rev BA Section 1: Introduction February 2014 Introduc tion Sec tion 1 Introduc tion Using this m anual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2 Reference Manu al 00809-0100-4952, Rev BA Section 1: Introduc tion February 2014 Introduction 1.2 R ece iving and inspection The 0085 Pipe Clamp Se nsor comes in sev eral diff eren t t ypes of ma terials and cl amp sizes so it's impor tant to inspect and verify that th e approp ri ate mode l was de livered be fore installa tion.
3 Reference Manu al 00809-0100-4952, Rev BA Section 2: Instal lation February 2014 Installa tion Sec tion 2 Installa tion Saf ety messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4 Reference Manu al 00809-0100-4952, Rev BA Section 2: Installation February 2014 Installa tion 2.2 Installation flowchar t and checklist Figure 2-1 is an install ation flowchart that provide s guidanc e through the installation proc ess.
5 Reference Manu al 00809-0100-4952, Rev BA Section 2: Instal lation February 2014 Installa tion The follo wing list is a summar y of the ste ps requ ired to compl ete a Pi pe Clamp Sensor installa tion. 1. Dete rmine where the Pipe Clamp Sensor is t o be placed within the pip ing system.
6 Reference Manu al 00809-0100-4952, Rev BA Section 2: Installation February 2014 Installa tion Figure 2-2. Sensor Lead Wire T ermi nation Pipe Clamp RTD Flying Leads an d Spring Loaded Single Element.
7 Reference Manu al 00809-0100-4952, Rev BA Section 3: Operation and mai ntenance February 2014 Operation and Mainte nance Sec tion 3 Ope ra tion and m ain te n anc e Saf ety messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
8 Reference Manu al 00809-0100-4952, Rev BA Section 3: Operation and mai ntenance February 2014 Ope rat ion a nd M aint ena nce 3.2 T roubleshooting If a malfunction is suspected despit e the absenc e.
9 Reference Manu al 00809-0100-4952, Rev AA Appendix A: Reference Data February 2014 Refe re nce Da t a A p p en d i x A R efer en ce dat a R ose mount Pipe Clamp Se nsor orde ring inf ormation . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 9 A .
10 Reference Manu al 00809-0100-4952, Rev AA Appendix A: Re ference Data February 2014 Ref ere n ce Da t a Code Pipe clamp material Stan dard Sta ndard P ASTM 304 SST (1 .4301) ★ Expanded B Duplex F51 (1.446 2) Code Inner diameter (D) Suitab le pipe size inch Suitab le pipe size DI N Clamp/bolt dimensions Stan dard Sta ndard 0022 22 mm 1 / 2 in.
11 Reference Manu al 00809-0100-4952, Rev AA Appendix A: Reference Data February 2014 Refe re nce Da t a Opti ons (inc lude with sele cted model number) Code Sensor o ptions Stan dard Sta ndard A1 Sin.
12 Reference Manu al 00809-0100-4952, Rev AA Appendix A: Re ference Data February 2014 Ref ere n ce Da t a A. 1. 1 D es i gn e x am p le dr a w in g s Figure A-1.
Reference Manual 00809-0100-4952, Rev BA Appendix B: Product Certifications February 2014 13 Produc t Cer tifications Appe ndix B Produc t Ce r tifications Approv ed manufacturing locations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
14 Reference Manu al 00809-0100-4952, Rev BA Appendix B: Product Ce rtifications February 2014 Produc t Cer tifications Eur o pe E1 AT E X F l a m e p r o o f Certificat e: FM12A TEX0065X Stand ards U sed: EN60079-0 :2012, EN60079-1:2007 Markings : II 2 G Ex d IIC T6…T1 Gb Special Conditions for Safe Use (X): 1.
15 Reference Manu al 00809-0100-4952, Rev BA Appendix B: Product Certifications February 2014 Produc t Cer tifications B.3 Installation drawings Figure B-1. FM Explosionproof T emperat ure Measur em ent Assembly (E5) Installation Drawing 00068-0013, Rev AG.
16 Reference Manu al 00809-0100-4952, Rev BA Appendix B: Product Ce rtifications February 2014 Produc t Cer tifications Figure B-2. CSA Explosionproof T emperature Measurem ent Assembly (E6) Installation Drawing 00068-0033, Rev AG.
.
Reference Manual 00809-0100-4952, Rev BA February 2014 St andard T erms and Cond itions of Sale can be found at www . rosem ount.com/te rms_of_sale The Emer son log o i s a tra dema rk a nd ser vi ce ma rk of E mer son Ele ct ric Co. Ro semount. the R ose mount logotype, and S MART F AM IL Y are registe red trademarks of R ose mount Inc.
Ein wichtiger Punkt beim Kauf des Geräts Emerson Process Management 00809-0100-4952 Rev BA (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Emerson Process Management 00809-0100-4952 Rev BA noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Emerson Process Management 00809-0100-4952 Rev BA - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Emerson Process Management 00809-0100-4952 Rev BA reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Emerson Process Management 00809-0100-4952 Rev BA erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Emerson Process Management 00809-0100-4952 Rev BA besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Emerson Process Management 00809-0100-4952 Rev BA verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Emerson Process Management 00809-0100-4952 Rev BA. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Emerson Process Management 00809-0100-4952 Rev BA gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.