Micro Motion ® Series 3000 MVD T ransmitters Net Oil Computer Supplement Instruction Manual P/N MMI-2001 1276, Rev . A March 2008.
©2008, Micro Motion, Inc . All rights reserved. ELITE and Pr oLink are regist ered trademarks, and MVD and MVD Direct Connect are trademarks o f Micro Motion, Inc., Boulder , Colorado. Micro Moti on is a registe red trade name of Micro Motion, Inc., Boulder , Colorado.
Net Oil Computer Supplement i Contents Chapter 1 Before Y o u Begin . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 1.1 About this m anual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
ii Micro Motion ® Series 3000 MVD Transmit ters Contents Chapter 4 Configuring the NOC Application . . . . . . . . . . . . . . . . . . . . . . . . . 23 4.1 About this ch apter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Net Oil Computer Supplement 1 NOC Overview NOC Configuration Using the Display Before Y ou Begin Chapter 1 Before Y ou Begin 1.1 About this manual This manual explain s ho w to conf igure and use the Net Oil Computer applicat ion on the Micro Motion ® Series 3000 MVD platform (a Mode l 3500 or Model 3700 MVD t ransmitter).
2 Micro Motion ® Series 3000 MVD Transmit ters Before Y ou Begin 1.4 Micro Motion customer service For customer service, phone the supp ort center nearest you: • In the U.
Net Oil Computer Supplement 3 NOC Overview NOC Configuration Using the Display Before Y ou Begin Chapter 2 NOC Over view 2.1 Overvie w This chapter discusses various topics that should be revie wed and considered before beginning configuration of the Series 3000 platform with the NOC application.
4 Micro Motion ® Series 3000 MVD Transmit ters NOC Overview 2.2.1 NOC system components The Series 3000 MVD NOC system requires: • One Series 3000 MVD transmitter with the Net Oil Computer softw are option • One Micro Motion sensor installed on the oil/w ater or oil le g Optional comp onents include : • A meter on the gas le g.
Net Oil Computer Supplement 5 NOC Overview NOC Overview NOC Configuration Using the Display Before Y ou Begin In Figure 2-1: • The NOC system is implemente d with a two-phase separator . • An optional gas meter is installe d, and gas data is sent to th e Series 3000 de vice via the frequenc y input.
6 Micro Motion ® Series 3000 MVD Transmit ters NOC Overview In Figure 2-2: • The NOC system is implemente d with a three-phase separator . • An optional gas meter is installed, and gas flo w rate data is sent to the Series 3000 de vice via the frequency input.
Net Oil Computer Supplement 7 NOC Overview NOC Overview NOC Configuration Using the Display Before Y ou Begin In Figure 2-3: • The NOC system is implemented with a Gas-Liquid Cylindrical Cyclone™ (GLCC). • A gas meter is installed on the gas le g.
8 Micro Motion ® Series 3000 MVD Transmit ters NOC Overview 2.2.3 Operation mod es The NOC system operates in either W ell T est mode or Continuous mod e: • In W ell T est mode, well tests can be performe d on up to 48 wells.
Net Oil Computer Supplement 9 NOC Overview NOC Overview NOC Configuration Using the Display Before Y ou Begin 2.2.4 Required well data The follo wing information is requ ired for each well t hat will be tested or measured b y the NOC system: • Density of dry oil from this well, at referenc e temperature and reference pressure.
10 Micro Motion ® Series 3000 MVD Transmit ters NOC Overview 2.3 NOC applicat ion features and o ptions This section describes sev eral features and options of the NOC application.
Net Oil Computer Supplement 11 NOC Overview NOC Overview NOC Configuration Using the Display Before Y ou Begin 2.3.3 Shrinkage fa ctors “Shrinkage” is a decrease in volume caused by the e v aporation of solution gas, b y the flashing of vo latile natural gas, or b y lo wered temperature during the crude oil stabilization process.
12 Micro Motion ® Series 3000 MVD Transmit ters NOC Overview T o determine the v alue to use for the driv e gain thre shold, ob serve dri ve gain values for this system during v arious flo w conditions.
Net Oil Computer Supplement 13 NOC Overview NOC Overview NOC Configuration Using the Display Before Y ou Begin Figure 2-8 Hold L ast Valu e effect on de nsity measurement 2.
14 Micro Motion ® Series 3000 MVD Transmit ters NOC Overview When a transient mist interv al is detected: • The mass flo w rate ove r the previous n seconds is av eraged and stored as the TMR M1 v alue, where n is the v alue conf igured for T i me Period.
Net Oil Computer Supplement 15 NOC Overview NOC Overview NOC Configuration Using the Display Before Y ou Begin Note the fo llowing: • Only the most recent 24 hours of data can be recalculated. • Recalculation is based on 15 -minute “snapshot” a verage v alues.
16 Micro Motion ® Series 3000 MVD Transmit ters NOC Overview 2.5 NOC measurement terminology The terms used in NOC measurement are listed and defined in T able 2-1. These terms are used in a v ariety of process va riables and loca tions throughout the NOC application.
Net Oil Computer Supplement 17 NOC Overview NOC Configuration Using the Display Before Y ou Begin Chapter 3 Using the Display and Menu System 3.1 About this chapter This chapter explains ho w to use the Series 3000 di splay and menu system.
18 Micro Motion ® Series 3000 MVD Transmit ters Using the Display and Menu Syst em 3.3 Menu systems Most Series 3000 display fun ctions are or ganized into two menu sy stems: • The Management menu allows you to perform configuration and maintenance task s.
Net Oil Computer Supplement 19 Using the Display and Menu Syst em NOC Overview NOC Configuration Using the Display Before Y ou Begin T o enter the menus: • T o enter the Management menu system, press the Security butt on. The Security b utton is in the lo wer right corner of the display , marked with a pad lock icon (see Figure 3-1).
20 Micro Motion ® Series 3000 MVD Transmit ters Using the Display and Menu Syst em Figure 3-4 Function buttons ALARMS DEVICE 1 Configuration Maintenance Security Language SEL HELP EXIT F3 function b .
Net Oil Computer Supplement 21 Using the Display and Menu Syst em NOC Overview NOC Configuration Using the Display Before Y ou Begin 3.5 Using the cursor control bu ttons The cursor control butto ns mov e the cu rsor around the display menus. In menus, the cursor is a re verse-vide o highlight bar .
22 Micro Motion ® Series 3000 MVD Transmit ters Using the Display and Menu Syst em Figure 3-5 Cursor control buttons Density ↓ Density Units g/cm3 Density Damping 1.7 sec Density Cutoff 0.005 000 g/cm3 Slug Low Limit 0.005000 g/cm3 SA VE HELP EXIT Density ↓ Density Units g/cm3 Density Damping 1.
Net Oil Computer Supplement 23 NOC Overview NOC Configuration Using the Display Before Y ou Begin Chapter 4 Configuring the NOC Application 4.1 About this chapter This chapter expl ains ho w to configure the NO C application and perform density determination procedures.
24 Micro Motion ® Series 3000 MVD Transmit ters Configuring the NOC Applica tion Figure 4-1 W ell Performance Measurement menu 4.3 Basic configuratio n procedure T o configure the NOC application, the following general steps are required: 1. Set Mode of Operation to Contin uous or W ell T est .
Net Oil Computer Supplement 25 Configuring the NOC Applica tion NOC Overview NOC Configuration Using the Display Before Y ou Begin NOC Overview NOC Configuration Using the Display Before Y ou Begin NOC Overview NOC Configuration Using the Display Before Y ou Begin NOC Overview NOC Configuration Using the Display Before Y ou Begin 4.
26 Micro Motion ® Series 3000 MVD Transmit ters Configuring the NOC Applica tion 7. Set the parameters in the Compensations menu as desired. •F o r T ransient Bubble Remedi ation , see Section 2.3.4 for a disc ussion of this feature, and see Section 4.
Net Oil Computer Supplement 27 Configuring the NOC Applica tion NOC Overview NOC Configuration Using the Display Before Y ou Begin NOC Overview NOC Configuration Using the Display Before Y ou Begin NOC Overview NOC Configuration Using the Display Before Y ou Begin NOC Overview NOC Configuration Using the Display Before Y ou Begin 9.
28 Micro Motion ® Series 3000 MVD Transmit ters Configuring the NOC Applica tion 10. If desired, configure the proc ess monitor to display NOC proce ss variables. Instructions for configuri ng the process monitor are in the manual entitl ed Series 3000 MVD T ransmitters and Contr ollers: Conf iguration an d Use Manual.
Net Oil Computer Supplement 29 Configuring the NOC Applica tion NOC Overview NOC Configuration Using the Display Before Y ou Begin NOC Overview NOC Configuration Using the Display Before Y ou Begin NOC Overview NOC Configuration Using the Display Before Y ou Begin NOC Overview NOC Configuration Using the Display Before Y ou Begin 4.
30 Micro Motion ® Series 3000 MVD Transmit ters Configuring the NOC Applica tion 4.5.2 Setting up pressure compensation fo r oil density an d water density T o set up pressure compensation for oil density and w ater density: 1.
Net Oil Computer Supplement 31 Configuring the NOC Applica tion NOC Overview NOC Configuration Using the Display Before Y ou Begin NOC Overview NOC Configuration Using the Display Before Y ou Begin NOC Overview NOC Configuration Using the Display Before Y ou Begin NOC Overview NOC Configuration Using the Display Before Y ou Begin 5.
32 Micro Motion ® Series 3000 MVD Transmit ters Configuring the NOC Applica tion Figure 4-2 Density determination – Last Dates screen Figure 4-3 Density determination – Pr ocedure Selection screen 4.9.1 Performing a density determination for water There are two density determination methods for water: in-line and manual.
Net Oil Computer Supplement 33 Configuring the NOC Applica tion NOC Overview NOC Configuration Using the Display Before Y ou Begin NOC Overview NOC Configuration Using the Display Before Y ou Begin NO.
34 Micro Motion ® Series 3000 MVD Transmit ters Configuring the NOC Applica tion During this period, the screen sho wn in Figure 4 -5 is displaye d. (The current pressure value may or may not be display ed.) Y ou can pres s ST OP to stop the av eraging.
Net Oil Computer Supplement 35 Configuring the NOC Applica tion NOC Overview NOC Configuration Using the Display Before Y ou Begin NOC Overview NOC Configuration Using the Display Before Y ou Begin NOC Overview NOC Configuration Using the Display Before Y ou Begin NOC Overview NOC Configuration Using the Display Before Y ou Begin 9.
36 Micro Motion ® Series 3000 MVD Transmit ters Configuring the NOC Applica tion 9. The NOC application con verts the observ ed water density to w ater density at reference temperature, and displays a screen similar to Fi gure 4-8.
Net Oil Computer Supplement 37 Configuring the NOC Applica tion NOC Overview NOC Configuration Using the Display Before Y ou Begin NOC Overview NOC Configuration Using the Display Before Y ou Begin NO.
38 Micro Motion ® Series 3000 MVD Transmit ters Configuring the NOC Applica tion Figure 4-10 Density determination for oil – In pr ocess 7. If you are using the density-based water cut, tak e a sample of the fluid in t he pipe during this a veraging period , then measure the water cut of the sample.
Net Oil Computer Supplement 39 Configuring the NOC Applica tion NOC Overview NOC Configuration Using the Display Before Y ou Begin NOC Overview NOC Configuration Using the Display Before Y ou Begin NO.
40 Micro Motion ® Series 3000 MVD Transmit ters Configuring the NOC Applica tion Figure 4-12 Density determina tion for oil – W ater cut entry screen 14. Enter the water cut measured in Step 7, then press SA VE . 15. Select Calculate at Ref , then press SEL .
Net Oil Computer Supplement 41 T roubleshooting Index Series 3000 Menus NOC Operation Chapter 5 Operation Mode – NOC 5.1 About this chapter This chapter expl ains ho w to us e the NOC application to run a we ll test or perform continuous measurement.
42 Micro Motion ® Series 3000 MVD Transmit ters Operation Mode – NOC Figure 5-1 W ell Performance Measurement menu – S electing the well Well Selection screens Well Selection screens View menu We.
Net Oil Computer Supplement 43 Operation Mode – NOC T roubleshooting Index Series 3000 Menus NOC Operation Figure 5-2 W ell Performance Measurement menu – Ru nning the well test Stop Well Test? We.
44 Micro Motion ® Series 3000 MVD Transmit ters Operation Mode – NOC 5.2.1 Running a well test T o run a well test: 1. Ensure that the NOC application is set for W ell T est mode, and that all necessary data for the well has been conf igured. 2. As sho wn in Figu re 5-1: a.
Net Oil Computer Supplement 45 Operation Mode – NOC T roubleshooting Index Series 3000 Menus NOC Operation 5.2.2 Viewing well test data Y ou can access well tes t data at se ve ral points in the menu.
46 Micro Motion ® Series 3000 MVD Transmit ters Operation Mode – NOC Ta b l e 5 - 2 Quick View data – We ll T est mode Proc ess v ariab le Definition A v erage net oil rate Current net oil flow rate. Ma y or may not include oil carr y-over , depending on TMR configuration.
Net Oil Computer Supplement 47 Operation Mode – NOC T roubleshooting Index Series 3000 Menus NOC Operation 5.2.3 Time periods for average, minimum, m aximum, and total values For the current test, running av erage, minimum, ma ximum, and total v alues for each process v ariable are calculated from the be ginning of the test.
48 Micro Motion ® Series 3000 MVD Transmit ters Operation Mode – NOC 5.2.5 Recalculating well test data Y ou can recalculate well test da ta for any stored well test. Y ou can perform the recalc ulation during a well test or between well tests. T o recalculate well test data: 1.
Net Oil Computer Supplement 49 Operation Mode – NOC T roubleshooting Index Series 3000 Menus NOC Operation 5.3 Continuous mode me asurement over view In Continuous mode, measuremen t begin s as soon as the system is up and running, or as soon as the system is config ured for Continuous mode measuremen t.
50 Micro Motion ® Series 3000 MVD Transmit ters Operation Mode – NOC Figure 5-3 W ell Performance Measurement menu – C ontinuous mode measuremen t View menu Well Perform ance Mea s View Productio.
Net Oil Computer Supplement 51 Operation Mode – NOC T roubleshooting Index Series 3000 Menus NOC Operation 5.3.1 Viewing Contin uous mode measurement data T o vie w basic data from Con tinuous mode measurement, use the Quick V iew menu sho wn in Figure 5-3.
52 Micro Motion ® Series 3000 MVD Transmit ters Operation Mode – NOC 5.3.2 Pausing and resuming Continuous mode mea surement Use the Pa use / Resume option sho wn in Figure 5-3 to pause and resume Contin uous mode measurement.
Net Oil Computer Supplement 53 Operation Mode – NOC T roubleshooting Index Series 3000 Menus NOC Operation 5.3.3 Resetting, saving, and managing Continuous mode time periods Running a verage, minimum, maxi mum, and total v alues are calculated from the beginning of Continuous mode measurement.
54 Micro Motion ® Series 3000 MVD Transmit ters Operation Mode – NOC 5.3.4 Other activity during Continu ous mode measurement During continuo us measurement, you can use the EXIT button on the W e ll Performance Measurement screen to move between the continuous measurem ent screens and the V iew menu.
Net Oil Computer Supplement 55 Operation Mode – NOC T roubleshooting Index Series 3000 Menus NOC Operation Figure 5-5 Archive records – Continuous mode measu rement View menu Well Performanc e Mea.
56 Micro Motion ® Series 3000 MVD Transmit ters Operation Mode – NOC 5.3.6 Recalculating Continuous mode da ta T o recalculate Continuous mode data, refer to Figure 5-5 and: 1. Select Recalculate from the W ell Performance Measurement menu. 2. Specify the archiv e record you wa nt to recalculate.
Net Oil Computer Supplement 57 Operation Mode – NOC T roubleshooting Index Series 3000 Menus NOC Operation 5.4 Changing mo des Changing from W ell T est mode to Continuous mode, or fro m Continuous mode to W ell T est mode, affects current measurement and data collection.
58 Micro Motion ® Series 3000 MVD Transmit ters.
Net Oil Computer Supplement 59 T roubleshooting Index Series 3000 Menus NOC Operation Chapter 6 Diagnostics and T roubleshooting 6.1 About this chapter This chapter provides information on the status alarms associated with the NOC application.
60 Micro Motion ® Series 3000 MVD Transmit ters.
Net Oil Computer Supplement 61 T roubleshooting Index Series 3000 Menus NOC Operation Appendix A Series 3000 Menu Flowcharts A.1 Overview This appendix provides menu fl o wcharts for the Series 3000 d.
62 Micro Motion ® Series 3000 MVD Transmit ters Series 3000 Menu Flowch arts A.3 View menu Figure A-2 shows the V iew menu. Figure A-2 View menu: Special applications – Net Oil Computer Screen 5 Va.
Net Oil Computer Supplement 63 Series 3000 Menu Flowch arts T roubleshooting Index Series 3000 Menus NOC Operation A.4 Management me nus The Management menu system is illustrated in Figures A-3 through A-8: • Figure A-3 sho ws the top lev el of the Management menu, plus the S ecurity and Language menus.
64 Micro Motion ® Series 3000 MVD Transmit ters Series 3000 Menu Flowch arts Figure A-4 Configuration menu Management Menu Configuration Inputs System ·T a g · Time ·D a t e · Alarm Severity · E.
Net Oil Computer Supplement 65 Series 3000 Menu Flowch arts T roubleshooting Index Series 3000 Menus NOC Operation Figure A-5 Configuration menu continued Management Menu Configuration Well Performanc.
66 Micro Motion ® Series 3000 MVD Transmit ters Series 3000 Menu Flowch arts Figure A-6 Configuration menu continued Management Menu Configuration Measurements Discrete Events · Discrete Event 1–5.
Net Oil Computer Supplement 67 Series 3000 Menu Flowch arts T roubleshooting Index Series 3000 Menus NOC Operation Figure A-7 Configuration menu continued Configure RS-485 · Protocol ·H A R T · Mod.
68 Micro Motion ® Series 3000 MVD Transmit ters Series 3000 Menu Flowch arts Figure A-8 Mainte nance menu Management Menu Maintenance Alarm History Active Alarm Log Alarm Event Log Process Inventory .
Net Oil Computer Supplement 69 T roubleshooting Index Series 3000 Menus NOC Operation Index A Archive records 53 B Buttons cursor control buttons 21 function buttons 19 Security button 19 C Communicat.
70 Micro Motion ® Series 3000 MVD Transmitters Index M Management menu 18 Security button 19 Manuals 1 Menu system flowcharts 61 Management menu 18 Management menu flowcharts 63 shortcuts 19 using 17.
Net Oil Computer Supplement 71 Index T roubleshooting Index Series 3000 Menus NOC Operation T TBR configuration 26, 30 overview 11 Temperature correction 1 0 Terminology 16 TMR configuration 26, 31 ov.
72 Micro Motion ® Series 3000 MVD Transmitters.
.
Micro Motion Inc. USA Worldwide Headqu arters 7070 Winchester Circle Boulder , Colorado 80301 T +1 303-527-5200 +1 800-522-6277 F +1 303-530-8459 Micro Motion Europe Emerson Process Management Neonstr.
Ein wichtiger Punkt beim Kauf des Geräts Emerson MMI-20011276 (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Emerson MMI-20011276 noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Emerson MMI-20011276 - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Emerson MMI-20011276 reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Emerson MMI-20011276 erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Emerson MMI-20011276 besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Emerson MMI-20011276 verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Emerson MMI-20011276. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Emerson MMI-20011276 gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.