Net Weight: 30.0 Lbs. Part No. F40BP72800004 Form No. BP7280-4 U.L. Model No.: KF100 READ AND SA VE THESE INSTRUCTIONS KF100AP01 Antique P ewter with Natural Cher r y/Mahogany Blades KF100DBK01 Distre.
W ARNING: T o avoid fire, shock, and serious personal injury , follow these instructions. Safety Instructions 1. Read your owner ’s manual carefully and keep it for future reference.
T ools Needed for Assembly One Phillips head screwdriver One wire stripper One stepladder Three 60-watt (max.) candelabra base bulbs Six wire connectors (supplied) Materials Wiring, outlet box and box connectors must be of type required by the local code.
Preset Memory Feature Y our remote control receiver is equipped with a preset memory feature. The receiv- er will remember the light intensity and fan speed when the light and fan are turned off from the wall switch. When the wall switch is turned back on, the lights and fan will resume operation as they were prior to the switch being turned off.
2. Slide the four switch levers on the code switch to your choice of ON (up) or down positions. Use a ball-point pen or small screwdriver and slide the levers firmly up or down. 3. In the receiver (Figure 1), slide the four switch levers to the same positions as set in the transmitter .
5. Reinstall the hanger ball (Figure 5) on the downrod as follows. Route the three 80” motor leads through the hanger ball and slide the hanger ball over the downrod. Position the pin through the two holes in the downrod and align the hanger ball so the pin is captured in the groove in the top of the hanger ball.
11 . Engage the connector of the switch housing/light fitter assembly with the motor connector (Figure 8). The two connectors are color-coded and must be mated correctly (color-to-color) before they can be engaged. Make sure the connectors close properly .
2. Carefully lift the fan and seat the hang- er ball/downrod assembly on the hang- er bracket that was just attached to the outlet box (Figure 12). Be sure the groove in the ball is lined up with the tab on the hanger bracket (Figure 1 1).
9 1. Position the supply wires to the left side of the outlet box (Figure 13); position the fan wires to the right side. Partially insert the remote control receiver (flat side up) until one end rests on the hanger ball as shown in Figure 13. NOTE: Make all wiring connections using wire connectors (supplied).
7. Screw three 60-watt (maximum) cande- labra base bulbs into the light fitter sockets (Figure 16). 8. Place the lower glass in the lower ring assembly (Figure 16).
NOTE: Slightly loosen the four screws securing the lower ring brackets to the switch housing assembly . 9. Securely grasp one of the lower ring posts and raise the lower ring up to one of the lower ring brackets. Secure the lower ring post to the lower ring brack- et using a bracket mounting screw (Figure 16).
12 Do not use water when cleaning your ceiling fan. It could damage the motor or the blades and create the possibility of an electrical shock. ! W ARNING The use of any other control not specifically approved for this fan could result in fire, shock and per- sonal injury .
13 T rouble Shooting TROUBLE PROBABLE CAUSE SUGGESTED REMEDY 1. Fan will not 1. Fuse or circuit breaker 1. Check main and branch start. blown. circuit fuses or circuit breakers. 2. Loose power line 2. Check line power connections connections to the fan, or to fan and wire.
14 Repair Parts 16 17 3 2 1 5 4 7 6 14 18 19 15 23 25 24 22 21 9 8 11 10 12 13 26 FAN/OFF FOR/REV LIGHT DIMMER HI MED LOW ® 20 BP7280, Olympia, KF100 7/31/06 10:57 AM Page 14.
Part Numbers Key Model No. Model No. Model No. N o . Description KF100AP01 KF100DBK01 KF100OZ01 * Hanger Pack, Consisting of: 761655-34 761655-36 761655-35 1 Bracket, Hanger Assembly (1) — — — 2.
LIMITED WARRANTY What The War ranty Covers: This warranty covers the motor and the other components and accessories of your Emerson ceiling fan against all defects in workmanship and materials. Y ou must be the original purchaser or user of the product to be covered.
Ein wichtiger Punkt beim Kauf des Geräts Emerson KF100DBK01 (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Emerson KF100DBK01 noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Emerson KF100DBK01 - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Emerson KF100DBK01 reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Emerson KF100DBK01 erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Emerson KF100DBK01 besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Emerson KF100DBK01 verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Emerson KF100DBK01. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Emerson KF100DBK01 gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.