Benutzeranleitung / Produktwartung CF943 des Produzenten Emerson
Zur Seite of 20
Part No. F40BP73350000 Form No. BP7335 ETL Model No.: CF943 READ AND SA VE THESE INSTRUCTIONS Net Weight: 37.9 Lbs. P ALAZZO ™ 54” Ceiling Fan Owner's Manual CF943AGW00 CF943BZH00 Model No.
DATE CODE: The date code of this fan may be found on the box, stamped in ink on a white label. You should record this data above and keep it in a safe place for future use. 2 W ARNING: T o avoid fire, shock, and serious personal injury , follow these instructions.
3 This Manual is Designed to Make it as Easy as Possible for Y ou to Assemble, Install, Operate and Maintain Y our Ceiling Fan Do not install or use fan if any part is damaged or missing.
4 2. Remove and discard the two cardboard shipping retainers securing the motor hub in the motor housing assembly . 3. Remove the fan motor assembly from the protective plastic bag. Place all carton contents on a protective surface. G. HANGER BRACKET D.
5 Setting Operating Frequency of Wall Control and Receiver (Figure 1) Y our wall control and receiver have code switches which must be set in one of 16 possible code combinations. The four levers (numbered 1, 2, 3, and 4) on the switches are factory-set in the ON (up) position.
Installation of Wall Control SINGLE-POLE INSTALLATION (Figure 2) 1. Disconnect power at circuit breaker or remove fuse. 2. Remove faceplate and screws from existing wall switch. Pull switch out from the wall box. Determine the “hot” wire and the “load” wire and disconnect these wires from switch.
4. Install a wall control in the wall box containing the “hot” wire first. Connect one black wire of the wall control to the “hot” wire. Securely connect wires with wire connectors supplied. 5. Connect the other black wire of the wall control to both remaining traveler wire(s) in the wall box and secure with wire connector supplied.
#10-32 x 5/16" OV AL HEAD FLANGE SCREW (2 per flange) BLADE ASSEMBL Y MOTOR HOUSING ASSEMBL Y FLANGE SLOT 4. Securely connect the black wire connector of the light fitter assembly to the black motor wire connector . Securely connect the white wire of the light fitter assembly to the white motor wire (Figure 9).
7. Carefully turn the fan motor assembly upside down in preparation for hanger ball/downrod installation. Place the partially assembled fan into the top half of the styrofoam as shown in Figure 1 1. Do not rest fan weight on the light fitter sockets. 8.
17. Y ou have now completed the initial assembly of your new ceiling fan. Y ou can now proceed with hanging and wiring your fan. 16. Reinstall the hanger ball on the downrod (Figure 16) as follows. Route the motor leads through the hanger ball and slide the hanger ball over the downrod.
1. Pull the wire leads, coming from the end of the downrod, and the supply wires through the open side of the hanger bracket. (Figure 20). a. Connect the white fan wire and the white supply wire to the white receiver wire (AC IN/ MOTOR N). b. Connect the black fan wire to the black receiver wire (TO MOT OR L).
WHITE SUPPL Y WIRE BLACK F AN WIRE SW105 RECEIVER TO 110V SUPPL Y SW113 FAN/LIGHT WALL CONTROL CAP THE YELLOW RECEIVER WIRE USING A WIRE CONNECTOR BLUE RECEIVER WIRE BLUE FAN WIRE BLACK SUPPL Y WIRE W.
OUTLET BOX RECEIVER CEILING COVER HANGER BRACKET 1-1/4" THREADED STUDS (2) Figure 22 7. Slide the receiver up and over the hanger bracket. Press the receiver against the ceiling, then slide the ceiling cover up to the threaded studs and turn until the studs protrude through the holes in the ceiling cover (Figure 23).
14 Operating Y our Ceiling Fan IMPORT ANT Fan installation must be completed, including the installation of the fan blades, before testing of the remote control. Y our Fan/Light Wall Control (Figure 26) has full control of your fan and light. However , airflow direction is controlled by a slide switch on the switch housing.
15 INSTRUCTION TO THE USER (if device contains a digital device) This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.
16 1. Downrod Extension Kits (see store or catalog). 2. Ceiling Fan Controls (see store or catalog). 3. Blades (see store or catalog). Do not use water when cleaning your ceiling fan. It could damage the motor or the blades and create the possibility of an electrical shock.
17 T rouble Shooting TROUBLE PROBABLE CAUSE SUGGESTED REMEDY 1. Fan will not 1. Fuse or circuit breaker 1. Check main and branch start. blown. circuit fuses or circuit breakers. W ARNING: Make sure main power is turned off. 2. Loose power line 2. Check line power connections connections to the fan.
Repair Parts 15 8 13 14 5 4 18 3 2 1 9 6 12 16 17 21 22 11 10 19 24 23 20 HI MED LOW FAN OFF REV LIGHT ON OFF 7 Before discarding packaging material, be certain all parts have been removed.
Part Numbers Key Model No. Model No. N o . Description CF943AGW00 CF943BZH00 * Hanger Pack, Consisting of: 761655-62 761655-61 1 Hanger Bracket — — 2 Hanger Ball — — 3 Downrod — — * Parts .
Part No. F40BP73350000 Printed in China 01/07 Form No. BP7335 Air Comfort Products DIVISION OF EMERSON ELECTRIC CO. 8100 W. Florissant ¥ St. Louis, MO 63136 LIMITED W ARRANTY What The W arranty Cover.
Ein wichtiger Punkt beim Kauf des Geräts Emerson CF943 (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Emerson CF943 noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Emerson CF943 - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Emerson CF943 reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Emerson CF943 erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Emerson CF943 besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Emerson CF943 verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Emerson CF943. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Emerson CF943 gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.