Part No. F40BP74470000 Form No. BP7447 U.L. Model No.: CF4801 and CF4501 READ AND SA VE THESE INSTRUCTIONS Ceiling F an Owner's Manual CF4801AB00 CF4801AP00 CF4801BS00 CF4801CK00 CF4801GBZ00 CF48.
WARNING: To avoid fire, shock, and serious personal injury, follow these instructions. Safety Instructions 1. Read your owner’s manual carefully and keep it for future reference. 2. Before servicing or cleaning unit, switch power off at service panel and lock service panel disconnecting means to prevent power from being switched on accidentally.
3 Unpac king Instr uctions 1. Check to see that you have received the following parts: NOTE: If you are uncertain of part description, refer to exploded view illustration. a. Fan motor and housing assembly b. One motor cover c. One ceiling cover d. Five blade flanges e.
4 U.L. Model No.: CF4801 and CF4501 Electrical R equir ements Ho w to Put Y our Ceiling F an T ogether SETSCREW CLEVIS PIN MOTOR COUPLING DOWNROD HAIRPIN CLIP MOTOR COUPLING HAIRPIN CLIP CLEVIS PIN DO.
5 U.L. Model No.: CF4801 and CF4501 Ho w to Put Y our Ceiling F an T ogether (continued) 6. Install the setscrew (supplied in loose parts bag) in the motor coupling and tighten using the 5/32" setscrew wrench (supplied) (Figure 3). 7. Screw two 1” threaded studs (provided) into the motor (Figure 4).
6 U.L. Model No.: CF4801 and CF4501 11. Use four #10-24 x 12mm pan head screws and flat washers (supplied) to secure flange to blade (Figure 6). Repeat for the remaining four blades.
7 U.L. Model No.: CF4801 and CF4501 Ho w to Hang Y our Ceiling F an The fan must be hung with at least 7' of clearance from floor to blades (Figure 9). CEILING FLOOR A T LEAST 7' Figure 9 WARNING ! The outlet box and joist must be securely mounted and capable of supporting at least 50 lbs.
8 U.L. Model No.: CF4801 and CF4501 Ho w to W ir e Y our Ceiling F an If you feel that you do not have enough electrical wiring knowledge or experience, have your fan installed by a licensed electrician. 1. For a wall control installation you will need a three- wire (with ground) conductor cable between the ceiling and wall outlet boxes.
9 Using Y our Ceiling F an 25-WA TT (Max.) CANDELABRA BASE LAMPS (3) UPLIGHT SOCKETS (3) Figure 14 SPEED CONTROL PULL CHAIN ACCENT LIGHT PULL CHAIN PENDANT COUPLING REVERSE SWITCH LARGE PENDANT COUPLING Figure 15 1.
Accessories This product is designed to use only those parts supplied with this product and/or any accessories designated specifically for use with this product by Emerson Electric Co. Substitution of parts or accessories not designated for use with this product by Emerson Electric Co.
11 U.L. Model No.: CF4801 and CF4501 T r ouble Shooting WARNING: For your own safety, turn off power at fuse box or circuit breaker before trouble shooting your fan. TROUBLE PROBABLE CAUSE SUGGESTED REMEDY 1. Fan will not start. 1. Fuse or circuit breaker blown.
12 R epair Par ts 6 13 1 2 3 16 14 15 7 10 20 19 24 18 17 5 4 23 27 12 11 29 30 25 26 31 18 28 32 11 12 33 22 8 21 9 U.L. Model No.: CF4801 and CF4501.
13 Cr o wn Select R epair Par ts Listing Before discarding packaging material, be certain all parts have been removed. HOW TO ORDER REP AIR P ARTS WHEN ORDERING REPAIR PARTS, ALWAYS GIVE THE FOLLOWING INFORMATION: • PART NUMBER • PART DESCRIPTION • NAME OF ITEM • MODEL NUMBER For repair parts, phone 1-800-654-3545.
14 U.L. Model No.: CF4801 and CF4501 Pr emium Select R epair Par ts Listing Ref. Premium Select Series No. Description CF4801AB00 CF4801AP00 CF4801BS00 CF4801CK00 CF4801GBZ Hanger Pack, 761655-3 76165.
15 U.L. Model No.: CF4801 and CF4501 Pr emium Select R epair Par ts Listing Ref. Premium Select Series No. Description CF4801GES00 CF4801ORB00 CF4801VNB00 CF4801WW00 Hanger Pack, 761655-35 761655-32 7.
Part No. F40BP74470000 Printed in China 01/12 Form No. BP7447 Air Comfort Products DIVISION OF EMERSON ELECTRIC CO. 8100 W. Florissant • St. Louis, MO 63136 U.
Ein wichtiger Punkt beim Kauf des Geräts Emerson CF4801VNB00 (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Emerson CF4801VNB00 noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Emerson CF4801VNB00 - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Emerson CF4801VNB00 reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Emerson CF4801VNB00 erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Emerson CF4801VNB00 besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Emerson CF4801VNB00 verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Emerson CF4801VNB00. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Emerson CF4801VNB00 gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.