Benutzeranleitung / Produktwartung CF4600GLZ00 des Produzenten Emerson
Zur Seite of 20
LIMITED WARRANTY What The War ranty Covers: This warranty covers the motor and the other components and accessories of your Emerson ceiling fan against all defects in workmanship and materials. Y ou must be the original purchaser or user of the product to be covered.
2 W ARNING: T o avoid fire, shock, and serious personal injury , follow these instructions. Safety Instructions 1. Read your owner ’s manual carefully and keep it for future reference.
3 This Manual is Designed to Make it as Easy as Possible for Y ou to Assemble, Install, Operate and Maintain Y our Ceiling Fan Do not install or use fan if any part is damaged or missing.
4 m. One loose parts bag containing: 1. T wo 8-32 x 1-1/4” threaded studs 2. T wo 8-32 x 1” threaded studs 3. Four knurled knobs 4. Four lockwashers 5. Five wire connectors 6. One clevis pin/hairpin clip assembly 7. Eleven 5-32 x 9/16” pan head screws 8.
5 1. Mount the fan blades to the blade flanges using three 10-32 x 1/2” pan head screws and three #10 flat washers (screws and washers supplied) (Figure 1). How to Assemble Y our Ceiling Fan T o reduce the risk of personal injury , do not bend the blade flange when installing the blade flanges, balancing the blades or cleaning the fan.
3. Carefully rest the switch cup assembly on the fan blades, then engage the connector of the switch cup assembly with the motor connector (Figure 3). The two connectors are keyed and must be mated correctly before they can be engaged. Make sure the connectors are engaged properly .
7 HAIRPIN CLIP CLEVIS PIN DOWNROD MOTOR COUPLING 5/16-18 x 1/4" SETSCREW Figure 6 PIN HANGER BALL SETSCREW DOWNROD Figure 5 8. Separate, untwist and unkink the three motor leads. Route the motor lead wires through the downrod and seat the downrod in the motor coupling (Figure 6).
14. Carefully place the upper housing over the upper glass, making certain that the upper glass seats firmly in the upper housing flange. 15. Align the two holes in the housing trim with two threaded holes in the upper housing (Figure 8). Loosely install two 8-32 x 1/2” pan head screws (supplied) to secure the trim.
9 18. Position the ceiling cover over the downrod and rest it on the upper housing (Figure 10). NOTE: Be careful not to scratch the finish on the upper housing. PIN HANGER BALL DOWNROD SETSCREW CEILING COVER ! W ARNING It is critical that the pin in the hanger ball is properly installed and the setscrew securely tightened.
10 Failure to seat tab in groove could cause damage to electrical wires and possible shock or fire hazard. ! W ARNING T o avoid possible fire or shock, do not pinch wires between the hanger ball/downrod assembly and hanger bracket. ! W ARNING NOTE: CEILING COVER, SUPPL Y WIRES AND F AN WIRES OMITTED FOR CLARITY .
11 1. Position the supply wires to the left side of the outlet box (Figure 14); position the fan wires to the right side. Partially insert the remote control receiver (flat side up) until one end rests on the hanger ball as shown in Figure 14. NOTE: Make all wiring connections using wire connectors (supplied).
3. Push the wires and connectors up into the outlet box while inserting the receiver fully into the hanger bracket. Position the antenna wire on top of the receiver . 4. Screw the two 1-1/4” threaded studs (supplied) into the tapped holes in the hanger bracket (Figure 14).
13 Setting Operating Frequency of W all Control and Receiver (Figure 17) Y our wall control and receiver have code switches which must be set in one of 16 possible code combinations. The four levers (numbered 1, 2, 3, and 4) on the switches are factory-set in the ON (up) position.
14 6. Screw wall control into wall box and install decorator style faceplate (included). Leave wall control in “OFF” mode until fan installation is completed.
15 ST ANDARD WIRING FOR EXISTING 3-WA Y CONTROL HOT BLK F AN/LIGHT WALL CONTROL BLK TRA VELER WIRES BLK BLK BLACK LOAD BLACK LOAD TRA VELER WIRES HOT BLK EXISTING WALL CONTROL EMERSON ® EMERSON ® HI.
Replacing Light Bulbs SETSCREW UPPER HOUSING/GLASS HOUSING TRIM 7-WA TT (MAXIMUM) CANDELABRA BULB (6) LOWER HOUSING FLANGE Figure 24 T o replace a burned out light bulb, loosen the setscrew in the upper housing and raise the upper housing/glass enough to access the defective bulb, then tighten the setscrew (Figure 24).
The use of any other control not specifically approved for this fan could result in fire, shock and personal injury . ! W ARNING This product is designed to use only those parts supplied with this product and/or any accessories designated specifically for use with this product by Emerson Electric Co.
Repair Parts 1 17 2 3 18 20 6 7 10 11 12 21 22 25 13 15 24 23 16 19 26 14 30 29 6 7 5 4 28 27 HI MED LOW FAN OFF LIGHT ON OFF EMERSON 1 2 3 4 ON 8 9 Before discarding packaging material, be certain all parts have been removed.
19 Part Numbers Key Model No. Model No. N o . Description CF4600GLZ00 CF4600WB00 * Hanger Pack, Consisting of: 761655-51 761655-52 1 Hanger Bracket — — 2 Hanger Ball — — 3 Downrod — — * Pa.
T rouble Shooting TROUBLE PROBABLE CAUSE SUGGESTED REMEDY 1. Fan will not 1. Fuse or circuit breaker 1. Check main and branch circuit fuses start. blown. or circuit breakers. W ARNING: Make sure main power is turned off. 2. Loose power line 2. Check line power connections to fan.
Ein wichtiger Punkt beim Kauf des Geräts Emerson CF4600GLZ00 (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Emerson CF4600GLZ00 noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Emerson CF4600GLZ00 - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Emerson CF4600GLZ00 reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Emerson CF4600GLZ00 erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Emerson CF4600GLZ00 besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Emerson CF4600GLZ00 verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Emerson CF4600GLZ00. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Emerson CF4600GLZ00 gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.