DE
Emerson logo
Offizielle Bedienungsanleitung

Emerson ATCA-7150

122 Seiten·3.3 MB·Netzteil·PDF·ENFRITNLJA
Emerson ATCA-7150
Inhaltsverzeichnis 157 Abschnitte ATCA-7150 and RTM-ATCA-7150 · Contents · About this Manual · Overview of Contents · … AnzeigenAusblenden
ATCA-7150 and RTM-ATCA-7150p.1Contentsp.3About this Manualp.11Overview of Contentsp.11Abbreviationsp.12Conventionsp.13Summary of Changesp.14Comments and Suggestionsp.15Safety Notesp.17EMCp.17Operationp.18Configuration Jumpersp.18Installationp.19Cabling and Connectorsp.20Laserp.20Environmentp.20Batteryp.21Introductionp.231.1 Featuresp.23Figure 1-1 Connection Between the ATCA-7150 and the RTMp.24Table 1-1 Functions of the ATCA-7150 and the RTMp.251.2 Standard Compliancesp.26Table 1-2 Standard Compliancesp.261.3 Ordering Informationp.261.3.1 Supported Board Modelsp.27Table 1-3 Product Nomenclaturep.271.3.2 Board Accessoriesp.27Table 1-4 Available Board Accessoriesp.27Installation of the RTM-ATCA-7150p.292.1 Overviewp.292.2 Unpacking and Inspecting RTM-ATCA-7150p.292.3 Environmental and Power Requirementsp.302.3.1 Environmental Requirementsp.30Table 2-1 Environmental Requirements RTM-ATCA-7150p.302.3.2 Power Requirementsp.31Table 2-2 Power Requirements RTM-ATCA-7150p.312.4 Module Installation and Removalp.322.4.1 Ejector Handlesp.332.4.2 ESD Preventionp.332.5 Installation Preparationsp.342.5.1 Wearing the ESD-Preventive Wrist Strapp.34Figure 2-1 Wearing the ESD-Preventive Wrist Strapp.352.5.2 Removing Filler Bladesp.36Figure 2-2 Removing the Filler Bladep.372.6 Installing and Replacing Daughter Cardsp.372.6.1 Precautionsp.382.6.2 Preparationsp.392.6.3 GE Daughter Cardp.402.6.3.1 Installation Positionsp.41Figure 2-3 Structure of RTM-ATCA-7150p.412.6.3.2 Installing the GE Daughter Cardp.42Figure 2-4 Installing the GE Daughter Cardp.442.6.3.3 Replacing the GE Daughter Cardp.45Figure 2-5 Replacing the GE Daughter Card.p.462.6.4 FC Daughter Cardp.472.6.4.1 Installation Positionsp.472.6.4.2 Installing the FC Daughter Cardp.47Figure 2-6 Installing the FC Daughter Cardp.502.6.4.3 Replacing the FC Daughter Cardp.51Figure 2-7 Replacing the FC Daughter Card.p.522.7 Installing and Removing the RTM-ATCA-7150p.532.7.1 Installing RTM-ATCA-7150p.53Figure 2-8 Installing RTM-ATCA-7150p.552.7.2 Removing RTM-ATCA-7150p.56Figure 2-9 Removing RTM-ATCA-7150p.572.8 Connecting External Cablesp.572.8.1 Connecting KVM Cablesp.58Figure 2-10 Connecting the KVM Cables to RTM-ATCA-7150p.592.8.2 Connecting Network Cablesp.59Figure 2-11 Connecting the Network Cables to RTM-ATCA-7150p.602.8.3 Connecting Optical Fibersp.60Figure 2-12 Connecting the Optical Fibers to RTM-ATCA-7150p.61Hardware Installation of ATCA-7150p.633.1 Overviewp.633.2 Unpacking and Inspecting the Bladep.63Table 3-1 List of Packing Itemsp.643.3 Environmental and Power Requirementsp.653.3.1 Environmental Requirementsp.65Table 3-2 Environmental Requirementsp.653.3.2 Power Requirementsp.66Table 3-3 Power Requirementsp.663.4 Precautionsp.673.4.1 ESD Preventionp.683.5 Checking the Installation Environmentp.69Table 3-4 Environment for Installing the ATCA-7150 Suitep.693.5.1 Wearing the ESD-Preventive Wrist Strapp.69Figure 3-1 Wearing the ESD-Preventive Wrist Strapp.703.5.2 Removing Blank Filler Bladesp.71Figure 3-2 Removing the Blank filler bladep.723.6 Installing Blade Accessoriesp.723.6.1 Precautionsp.733.6.2 Optional Components Supported by the ATCA-7150p.73Table 3-5 Optional Components Supported by the ATCA-7150 Suitep.743.6.3 Preparationsp.743.6.4 DIMMp.75Figure 3-3 Positions of the DIMM Interfacesp.76Table 3-6 DIMM Configuration on the ATCA-7150p.763.6.4.1 Installing the DIMMp.76Figure 3-4 Installing the DIMMp.783.6.4.2 Replacing the DIMMp.78Figure 3-5 Removing the DIMMp.803.6.5 Hard Diskp.803.6.5.1 Installing the Hard Diskp.80Figure 3-6 Installing the Hard Diskp.823.6.5.2 Replacing the Hard Diskp.83Figure 3-7 Removing the Hard Diskp.843.7 Installing and Removing the Bladep.853.7.1 Installationp.853.7.1.1 Installing the ATCA-7150 in a Powered Shelfp.85Figure 3-8 Installing the ATCA-7150p.863.7.1.2 Checking the Installationp.863.7.1.3 Power-Onp.873.7.2 Removalp.883.7.2.1 Power Offp.883.7.2.2 Removing the ATCA-7150p.89Figure 3-9 Removing the ATCA-7150p.903.8 Ejector Handlesp.90Table 3-7 Insertion and Removal of the ATCA-7150p.91Table 3-8 Power-On and Power-Off of the ATCA-7150p.91A Troubleshootingp.93A.1 Overviewp.93A.2 Precautionsp.93A.3 Principlesp.93A.4 Resourcesp.94A.5 Contacting Emerson Network Power for Technical Supportp.94A.6 LED Display Exceptionsp.95A.6.1 LEDs Are Offp.95A.6.2 In Service (IS) LED Blinksp.95A.7 Power-On Startup Exceptionsp.96A.8 Component Exceptionsp.97A.8.1 Component Is Unavailablep.97A.8.2 Number of DIMMs Is Inconsistentp.97A.9 Power Exceptionsp.98A.9.1 ATCA-7150 Cannot Be Startedp.98A.9.2 ATCA-7150 Automatically Shuts Downp.99A.10 Peripheral Exceptionsp.99A.10.1 Keyboard Cannot Be Usedp.99A.10.2 Mouse Cannot Be Usedp.100A.10.3 Monitor Remains Darkp.100A.10.4 Monitor Display Is Abnormalp.101A.10.5 No Information Is Displayed on the Monitorp.101A.11 Other Exceptionsp.102A.11.1 USB Interface Cannot Be Usedp.102A.11.2 Network Connection Is Faultyp.102A.11.3 A Fault Occurs in Softwarep.103A.12 Uncertain Exceptionsp.103A.13 POST Code Checkpointsp.105Table A-1 POST code checkpointsp.105A.14 DIM Code Checkpointsp.109Table A-2 DIM code checkpointsp.111A.15 ACPI Code Checkpointsp.112Table A-3 ACPI code checkpointsp.112B Related Documentationp.113B.1 Emerson Network Power - Embedded Computing Documentsp.113Table B-1 Emerson Network Power - Embedded Computing Publicationsp.113B.2 Related Specificationsp.113Table B-2 Related Specificationsp.113
Page 1 of the Emerson ATCA-7150 user manual — ATCA-7150 and RTM-ATCA-7150 Getting Started Document: 6806800G42B December 2008
Seite 1 · Zum Vergrößern klicken
Seite 1

Embedded Computing for Business-Critical ContinuityTM

ATCA-7150 and RTM-ATCA-7150 Getting Started Document: 6806800G42B December 2008

Emerson ATCA-7150 — ATCA-7150 and RTM-ATCA-7150 Getting Started Document: 6806800G42B December 2008 diagram (page 1)
Abb. 1 · ATCA-7150 and RTM-ATCA-7150 Getting Started Document…
Page 2 of the Emerson ATCA-7150 user manual — Contact Address
Seite 2 · Zum Vergrößern klicken
Seite 2

All rights reserved.

Trademarks

Emerson, Business-Critical Continuity, Emerson Network Power and the Emerson Network Power logo are trademarks and service marks of Emerson Electric Co. © 2008 Emerson Electric Co. All other product or service names are the property of their respective owners.

Intel® is a trademark or registered trademark of Intel Corporation or its subsidiaries in the United States and other countries.

Java™ and all other Java-based marks are trademarks or registered trademarks of Sun Microsystems, Inc. in the U.S. and other countries.

Microsoft®, Windows® and Windows Me® are registered trademarks of Microsoft Corporation; and Windows XP™ is a trademark of Microsoft Corporation.

PICMG®, CompactPCI®, AdvancedTCA™ and the PICMG, CompactPCI and AdvancedTCA logos are registered trademarks of the PCI Industrial Computer Manufacturers Group.

UNIX® is a registered trademark of The Open Group in the United States and other countries.

Notice

While reasonable efforts have been made to assure the accuracy of this document, Emerson assumes no liability resulting from any omissions in this document, or from the use of the information obtained therein. Emerson reserves the right to revise this document and to make changes from time to time in the content hereof without obligation of Emerson to notify any person of such revision or changes.

Electronic versions of this material may be read online, downloaded for personal use, or referenced in another document as a URL to a Emerson website. The text itself may not be published commercially in print or electronic form, edited, translated, or otherwise altered without the permission of Emerson,

It is possible that this publication may contain reference to or information about Emerson products (machines and programs), programming, or services that are not available in your country. Such references or information must not be construed to mean that Emerson intends to announce such Emerson products, programming, or services in your country.

Limited and Restricted Rights Legend

If the documentation contained herein is supplied, directly or indirectly, to the U.S. Government, the following notice shall apply unless otherwise agreed to in writing by Emerson.

Use, duplication, or disclosure by the Government is subject to restrictions as set forth in subparagraph (b)(3) of the Rights in Technical Data clause at DFARS 252.227-7013 (Nov. 1995) and of the Rights in Noncommercial Computer Software and Documentation clause at DFARS 252.227-7014 (Jun. 1995).

Contact Address

Emerson Network Power - Embedded Computing

Lilienthalstr. 15

© 2008 Emerson · 85579 Neubiberg/Munich · Germany

Page 3 of the Emerson ATCA-7150 user manual — Inhaltsverzeichnis
Seite 3 · Inhalt
Inhalt

Inhalt

ATCA-7150 and RTM-ATCA-7150p.1Contentsp.3About this Manualp.11Overview of Contentsp.11Abbreviationsp.12Conventionsp.13Summary of Changesp.14Comments and Suggestionsp.15Safety Notesp.17EMCp.17Operationp.18Configuration Jumpersp.18Installationp.19Cabling and Connectorsp.20Laserp.20Environmentp.20Batteryp.21Introductionp.231.1 Featuresp.23Figure 1-1 Connection Between the ATCA-7150 and the RTMp.24Table 1-1 Functions of the ATCA-7150 and the RTMp.251.2 Standard Compliancesp.26Table 1-2 Standard Compliancesp.261.3 Ordering Informationp.261.3.1 Supported Board Modelsp.27Table 1-3 Product Nomenclaturep.271.3.2 Board Accessoriesp.27Table 1-4 Available Board Accessoriesp.27Installation of the RTM-ATCA-7150p.292.1 Overviewp.292.2 Unpacking and Inspecting RTM-ATCA-7150p.292.3 Environmental and Power Requirementsp.302.3.1 Environmental Requirementsp.30Table 2-1 Environmental Requirements RTM-ATCA-7150p.302.3.2 Power Requirementsp.31Table 2-2 Power Requirements RTM-ATCA-7150p.312.4 Module Installation and Removalp.322.4.1 Ejector Handlesp.332.4.2 ESD Preventionp.332.5 Installation Preparationsp.342.5.1 Wearing the ESD-Preventive Wrist Strapp.34Figure 2-1 Wearing the ESD-Preventive Wrist Strapp.352.5.2 Removing Filler Bladesp.36Figure 2-2 Removing the Filler Bladep.372.6 Installing and Replacing Daughter Cardsp.372.6.1 Precautionsp.382.6.2 Preparationsp.392.6.3 GE Daughter Cardp.402.6.3.1 Installation Positionsp.41Figure 2-3 Structure of RTM-ATCA-7150p.412.6.3.2 Installing the GE Daughter Cardp.42Figure 2-4 Installing the GE Daughter Cardp.442.6.3.3 Replacing the GE Daughter Cardp.45Figure 2-5 Replacing the GE Daughter Card.p.462.6.4 FC Daughter Cardp.472.6.4.1 Installation Positionsp.472.6.4.2 Installing the FC Daughter Cardp.47Figure 2-6 Installing the FC Daughter Cardp.502.6.4.3 Replacing the FC Daughter Cardp.51Figure 2-7 Replacing the FC Daughter Card.p.522.7 Installing and Removing the RTM-ATCA-7150p.532.7.1 Installing RTM-ATCA-7150p.53Figure 2-8 Installing RTM-ATCA-7150p.552.7.2 Removing RTM-ATCA-7150p.56Figure 2-9 Removing RTM-ATCA-7150p.572.8 Connecting External Cablesp.572.8.1 Connecting KVM Cablesp.58Figure 2-10 Connecting the KVM Cables to RTM-ATCA-7150p.592.8.2 Connecting Network Cablesp.59Figure 2-11 Connecting the Network Cables to RTM-ATCA-7150p.602.8.3 Connecting Optical Fibersp.60Figure 2-12 Connecting the Optical Fibers to RTM-ATCA-7150p.61Hardware Installation of ATCA-7150p.633.1 Overviewp.633.2 Unpacking and Inspecting the Bladep.63Table 3-1 List of Packing Itemsp.643.3 Environmental and Power Requirementsp.653.3.1 Environmental Requirementsp.65Table 3-2 Environmental Requirementsp.653.3.2 Power Requirementsp.66Table 3-3 Power Requirementsp.663.4 Precautionsp.673.4.1 ESD Preventionp.683.5 Checking the Installation Environmentp.69Table 3-4 Environment for Installing the ATCA-7150 Suitep.693.5.1 Wearing the ESD-Preventive Wrist Strapp.69Figure 3-1 Wearing the ESD-Preventive Wrist Strapp.703.5.2 Removing Blank Filler Bladesp.71Figure 3-2 Removing the Blank filler bladep.723.6 Installing Blade Accessoriesp.723.6.1 Precautionsp.733.6.2 Optional Components Supported by the ATCA-7150p.73Table 3-5 Optional Components Supported by the ATCA-7150 Suitep.743.6.3 Preparationsp.743.6.4 DIMMp.75Figure 3-3 Positions of the DIMM Interfacesp.76Table 3-6 DIMM Configuration on the ATCA-7150p.763.6.4.1 Installing the DIMMp.76Figure 3-4 Installing the DIMMp.783.6.4.2 Replacing the DIMMp.78Figure 3-5 Removing the DIMMp.803.6.5 Hard Diskp.803.6.5.1 Installing the Hard Diskp.80Figure 3-6 Installing the Hard Diskp.823.6.5.2 Replacing the Hard Diskp.83Figure 3-7 Removing the Hard Diskp.843.7 Installing and Removing the Bladep.853.7.1 Installationp.853.7.1.1 Installing the ATCA-7150 in a Powered Shelfp.85Figure 3-8 Installing the ATCA-7150p.863.7.1.2 Checking the Installationp.863.7.1.3 Power-Onp.873.7.2 Removalp.883.7.2.1 Power Offp.883.7.2.2 Removing the ATCA-7150p.89Figure 3-9 Removing the ATCA-7150p.903.8 Ejector Handlesp.90Table 3-7 Insertion and Removal of the ATCA-7150p.91Table 3-8 Power-On and Power-Off of the ATCA-7150p.91A Troubleshootingp.93A.1 Overviewp.93A.2 Precautionsp.93A.3 Principlesp.93A.4 Resourcesp.94A.5 Contacting Emerson Network Power for Technical Supportp.94A.6 LED Display Exceptionsp.95A.6.1 LEDs Are Offp.95A.6.2 In Service (IS) LED Blinksp.95A.7 Power-On Startup Exceptionsp.96A.8 Component Exceptionsp.97A.8.1 Component Is Unavailablep.97A.8.2 Number of DIMMs Is Inconsistentp.97A.9 Power Exceptionsp.98A.9.1 ATCA-7150 Cannot Be Startedp.98A.9.2 ATCA-7150 Automatically Shuts Downp.99A.10 Peripheral Exceptionsp.99A.10.1 Keyboard Cannot Be Usedp.99A.10.2 Mouse Cannot Be Usedp.100A.10.3 Monitor Remains Darkp.100A.10.4 Monitor Display Is Abnormalp.101A.10.5 No Information Is Displayed on the Monitorp.101A.11 Other Exceptionsp.102A.11.1 USB Interface Cannot Be Usedp.102A.11.2 Network Connection Is Faultyp.102A.11.3 A Fault Occurs in Softwarep.103A.12 Uncertain Exceptionsp.103A.13 POST Code Checkpointsp.105Table A-1 POST code checkpointsp.105A.14 DIM Code Checkpointsp.109Table A-2 DIM code checkpointsp.111A.15 ACPI Code Checkpointsp.112Table A-3 ACPI code checkpointsp.112B Related Documentationp.113B.1 Emerson Network Power - Embedded Computing Documentsp.113Table B-1 Emerson Network Power - Embedded Computing Publicationsp.113B.2 Related Specificationsp.113Table B-2 Related Specificationsp.113
Page 11 of the Emerson ATCA-7150 user manual — Overview of Contents
Seite 11 · Zum Vergrößern klicken
Seite 11
Emerson ATCA-7150 — About this Manual diagram (page 11)
Abb. 2 · About this Manual

Overview of Contents

This document describes the ATCA-7150 and RTM-ATCA-7150 server suite (hereinafter referred to as the ATCA-7150 and RTM-ATCA-7150 suite) in the following aspects:

z Functions, features, and appearance of the ATCA-7150 and RTM-ATCA-7150

z How to install, deploy, and maintain the ATCA-7150 and RTM-ATCA-7150

The user must be a professional engineer in the server device field, who has been trained and is able to identify danger levels when operating the device.

The body part focuses on the operation process, while the appendix part contains a lot of supporting information. This helps you to get the required information quickly and accurately.

This manual is divided into the following chapters and appendices.

z Safety Notes on page 17 lists safety notes applicable to the blade.

z Sicherheitshinweise on page 23 is the German translation of the previous English safety notes (this had to be included for legal reasons).

z Chapter 1, Introduction, on page 29 describes the main features of the ATCA-7150 and RTM-ATCA-7150.

z Chapter 2, Installation of the RTM-ATCA-7150, on page 35 describes the installation of the RTM.

z Chapter 3, Hardware Installation of ATCA-7150, on page 69 describes installation prerequisites including the blade installation itself of the front blade.

z Troubleshooting on page 99 provides troubleshooting information.

z Related Documentation on page 119 provides links to further ATCA-7150 and RTM-ATCA- 7150-related documentation.

Page 12 of the Emerson ATCA-7150 user manual — Abbreviations
Seite 12 · Zum Vergrößern klicken
Seite 12
Emerson ATCA-7150 — Abbreviations diagram (page 12)
Abb. 3 · Abbreviations

Abbreviations

This document uses the following abbreviations:

AbbreviationDefinition ACAAustralian Communications Authority BIOSBasic Input/Output System BMCBaseboard Management Controller CMOSComplementary Metal Oxide Semiconductor CPUCentral Processing Unit DCDirect Current DIMMDual Inline Memory Module ECCError Checking and Correcting EIAElectronics Industries Association EMCElectromagnetic Compatibility ESDElectro-Static Discharge FBDFully Buffer DIMM FCFiber Channel FCCFederal Communications Commission FRUField Replaceable Unit GEGigabit Ethernet IECInternational Electrotechnical Commission IPMBIntelligent Platform Management BUS IPMIIntelligent Platform Management Interface KVMKeyboard, Video, and Mouse OOSOut of Service PCIPeripheral Component Interconnect PEMPower Entry Module POSTPower-On Self Test RAIDRedundant Arrays of Independent Disks
Emerson ATCA-7150 — Abbreviations diagram (page 12)
Abb. 4 · Abbreviations
Page 13 of the Emerson ATCA-7150 user manual — Conventions
Seite 13 · Zum Vergrößern klicken
Seite 13
Emerson ATCA-7150 — Conventions diagram (page 13)
Abb. 5 · Conventions

Conventions

The following table describes the conventions used throughout this manual.

Emerson ATCA-7150 — Conventions diagram (page 13)
Abb. 6 · Conventions

0x00000000 Typical notation for hexadecimal numbers (digits are 0 through F), for example used for addresses and offsets

0b0000 Same for binary numbers (digits are 0 and 1)

Screen Used for on-screen output and code related elements or commands in body text

Courier + Bold Used to characterize user input and to separate it from system output

Reference Used for references and for table and figure descriptions

[text] Notation for software buttons to click on the screen and parameter description

Page 14 of the Emerson ATCA-7150 user manual — Summary of Changes
Seite 14 · Zum Vergrößern klicken
Seite 14
Emerson ATCA-7150 — Summary of Changes diagram (page 14)
Abb. 7 · Summary of Changes
Emerson ATCA-7150 — Summary of Changes diagram (page 14)
Abb. 8 · Summary of Changes

... Repeated item for example node 1, node 2, ..., node 12

Omission of information from example/command that is not necessary at the time being

.. Ranges, for example0..4 means one of the integers 0,1,2,3, and 4 (used in registers)

Indicates a hazardous situation which, if not avoided, could result in death or serious injury

Indicates a hazardous situation which, if not avoided, may result in minor or moderate injury

Summary of Changes

This manual has been revised and replaces all prior editions.

Emerson ATCA-7150 — Summary of Changes diagram (page 14)
Abb. 9 · Summary of Changes

6806800G42B December 2008 Updated to Emerson layout, editorial changes

Page 15 of the Emerson ATCA-7150 user manual — Comments and Suggestions
Seite 15 · Zum Vergrößern klicken
Seite 15
Emerson ATCA-7150 — Comments and Suggestions diagram (page 15)
Abb. 10 · Comments and Suggestions

Comments and Suggestions

We welcome and appreciate your comments on our documentation. We want to know what you think about our manuals and how we can make them better.

Mail comments to us by filling out the following online form: http://www.emersonnetworkpowerembeddedcomputing.com/ > Contact Us > Online Form

In "Area of Interest" select "Technical Documentation". Be sure to include the title, part number, and revision of the manual and tell us how you used it.

Page 16 of the Emerson ATCA-7150 user manual — Comments and Suggestions
Seite 16 · Zum Vergrößern klicken
Seite 16
Emerson ATCA-7150 — Comments and Suggestions diagram (page 16)
Abb. 11 · Comments and Suggestions
Page 17 of the Emerson ATCA-7150 user manual — EMC
Seite 17 · Zum Vergrößern klicken
Seite 17
Emerson ATCA-7150 — Safety Notes diagram (page 17)
Abb. 12 · Safety Notes

This section provides warnings that precede potentially dangerous procedures throughout this manual. Instructions contained in the warnings must be followed during all phases of operation, service, and repair of this equipment. You should also employ all other safety precautions necessary for the operation of the equipment in your operating environment. Failure to comply with these precautions or with specific warnings elsewhere in this manual could result in personal injury or damage to the equipment.

Emerson Network Power intends to provide all necessary information to install and handle the product in this manual. Because of the complexity of this product and its various uses, we do not guarantee that the given information is complete. If you need additional information, ask your Emerson Network Power representative.

The product has been designed to meet the standard industrial safety requirements. It must not be used except in its specific area of office telecommunication industry and industrial control.

Only personnel trained by Emerson Network Power or persons qualified in electronics or electrical engineering are authorized to install, remove or maintain the product.

The information given in this manual is meant to complete the knowledge of a specialist and must not be used as replacement for qualified personnel.

Keep away from live circuits inside the equipment. Operating personnel must not remove equipment covers. Only Factory Authorized Service Personnel or other qualified service personnel may remove equipment covers for internal subassembly or component replacement or any internal adjustment.

Do not install substitute parts or perform any unauthorized modification of the equipment or the warranty may be voided. Contact your local Emerson Network Power representative for service and repair to make sure that all safety features are maintained.

EMC

This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications.

Page 18 of the Emerson ATCA-7150 user manual — Configuration Jumpers
Seite 18 · Zum Vergrößern klicken
Seite 18
Emerson ATCA-7150 — Operation diagram (page 18)
Abb. 13 · Operation

Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. Changes or modifications not expressly approved by Emerson Network Power Embedded Computing could void the user's authority to operate the equipment. Board products are tested in a representative system to show compliance with the above mentioned requirements. A proper installation in a compliant system will maintain the required performance. Use only shielded cables when connecting peripherals to assure that appropriate radio frequency emissions compliance is maintained.

Operation

Damage of the Product Surface of the Product High humidity and condensation on the product surface causes short circuits. Do not operate the product outside the specified environmental limits. Make sure the product is completely dry and there is no moisture on any surface before applying power. Do not operate the product below -5°C.

Overheating and Damage of the Product Operating the product without forced air cooling may lead to overheating and thus damage of the product. When operating the product, make sure that forced air cooling is available in the shelf.

Configuration Jumpers

Malfunction of the Product Reserved jumpers might carry production-related functions and can cause the product to malfunction if their setting is changed. Therefore, do not change settings of jumpers marked as "Reserved".

Page 19 of the Emerson ATCA-7150 user manual — Installation
Seite 19 · Zum Vergrößern klicken
Seite 19
Emerson ATCA-7150 — Installation diagram (page 19)
Abb. 14 · Installation

Installation

Damage of the Product and Additional Devices and Modules Incorrect installation or removal of additional devices or modules may damage the product or the additional devices or modules. Before installing or removing additional devices or modules, read the respective documentation.

Damage of Circuits Electrostatic discharge and incorrect installation and removal of the product can damage circuits or shorten their life. Before touching the product or electronic components, make sure that your are working in an ESD-safe environment.

Damage of the Product Incorrect installation of the product can cause damage of the product. Only use handles when installing/removing the product to avoid damage/deformation to the face plate and/or PCB.

Damage to the Product/Backplane or System Components Bent pins or loose components can cause damage to the product, the backplane, or other system components. Therefore, carefully inspect the product and the backplane for both pin and component integrity before installation.

Page 20 of the Emerson ATCA-7150 user manual — Environment
Seite 20 · Zum Vergrößern klicken
Seite 20
Emerson ATCA-7150 — Cabling and Connectors diagram (page 20)
Abb. 15 · Cabling and Connectors

Emerson Network Power Embedded Computing (ENPEC) and our suppliers take significant steps to ensure there are no bent pins on the backplane or connector damage to the boards prior to leaving the factory. Bent pins caused by improper installation or by inserting boards with damaged connectors could void the ECC warranty for the backplane or boards.

Incorrect installation of the product can cause blade damage. Only use handles for when installing/removing the product to avoid damage/deformation to the face plate and/or PCB

Cabling and Connectors

Damage of the Product The RJ-45 connector(s) on the face plate are either twisted-pair Ethernet (TPE) or E1/T1/J1 interfaces. Connecting an E1/T1/J1 line to an Ethernet connector may damage the product.

z Make sure that TPE connectors near your working area are clearly marked as network connectors.

z Verify that the length of an electric cable connected to a TPE bushing does not exceed 100 meters.

z Make sure the TPE bushing of the product is connected only to safety extra low voltage circuits (SELV circuits). If in doubt, ask your system administrator.

Laser

This product is a Class 1 laser product. The use of controls or adjustments or performance of procedures other than those specified herein may result in hazardous radiation exposure.

Environment

Always dispose of used blades, system components and RTMs according to your country’s legislation and manufacturer’s instructions.

Page 21 of the Emerson ATCA-7150 user manual — Battery
Seite 21 · Zum Vergrößern klicken
Seite 21
Emerson ATCA-7150 — Battery diagram (page 21)
Abb. 16 · Battery

Battery

Board/System damage Incorrect exchange of lithium batteries can result in a hazardous explosion. When exchanging the on-board lithium battery, make sure that the new and the old battery are exactly the same battery models. If the respective battery model is not available, contact your local Emerson Network Power sales representative for the availablity of alternative officially approved battery models.

Page 22 of the Emerson ATCA-7150 user manual — Battery
Seite 22 · Zum Vergrößern klicken
Seite 22
Emerson ATCA-7150 — Battery diagram (page 22)
Abb. 17 · Battery
Page 23 of the Emerson ATCA-7150 user manual — 1.1 Features
Seite 23 · Zum Vergrößern klicken
Seite 23
Emerson ATCA-7150 — Introduction diagram (page 23)
Abb. 18 · Introduction

1.1 Features

The ATCA-7150 and RTM-ATCA-7150 server blade suite features the capabilities of high speed calculation and mass data processing.

The ATCA-7150 and RTM-ATCA-7150 suite consists of:

z ATCA-7150 and RTM-ATCA-7150

z RTM-ATCA-7150 The RTM-ATCA-7150 is the rear transition module (RTM) of the server blade.

A server blade must work with an RTM of the server blade. For example, the ATCA-7150 works with the RTM-ATCA-7150.

You can install the ATCA-7150 in any node slot of your shelf. The RTM-ATCA-7150 is installed in the slot that is paired with the ATCA-7150 slot.

Page 24 of the Emerson ATCA-7150 user manual — Figure 1-1 Connection Between the ATCA-7150 and the RTM
Seite 24 · Zum Vergrößern klicken
Seite 24
Emerson ATCA-7150 — Figure 1-1 Connection Between the ATCA-7150 and the RTM diagram (page 24)
Abb. 19 · Figure 1-1 Connection Between the ATCA-7150 and the…

Figure 1-1 shows the connection between the ATCA-7150 and the RTM of the server blade.

Figure 1-1 Connection Between the ATCA-7150 and the RTM

Emerson ATCA-7150 — Figure 1-1 Connection Between the ATCA-7150 and the RTM diagram (page 24)
Abb. 20 · Figure 1-1 Connection Between the ATCA-7150 and the…

You can choose to use the RTM-ATCA-7150 according to the actual application.

The backplane is one part of the shelf. For details on the backplane and shelf, refer to the respective system documentation.

Page 25 of the Emerson ATCA-7150 user manual — Table 1-1 Functions of the ATCA-7150 and the RTM
Seite 25 · Zum Vergrößern klicken
Seite 25
Emerson ATCA-7150 — Table 1-1 Functions of the ATCA-7150 and the RTM diagram (page 25)
Abb. 21 · Table 1-1 Functions of the ATCA-7150 and the RTM

Table 1-1 lists the functions of the ATCA-7150 and the RTM.

Table 1-1 Functions of the ATCA-7150 and the RTM

Processing functions z Supports two dual-core LV Intel Xeon 5138 (2.13 GHz) processors

z Supports 4 MB L2 cache

z Supports up to four FB-DIMMs

z Supports the DIMM with a capacity of 512 MB, 1 GB, 2 GB, or 4 GB. The maximum capacity is 16 GB

Interface functions z 10/100/1000Base-T

z Provides two USB 2.0 interfaces (compatible with USB 1.1)

z Provides one IPMC serial port (also used as the system serial port, the serial port standards are RS232 and RJ-45)

z Provides serial port to access CPU and IPMC serial console

z Provides two SAS hard disks

z The RTM-ATCA-7150 that works with the ATCA-7150 provides a monitor interface and a USB 2.0 interface (compatible with USB1.1). Through optional daughter cards, the RTM-ATCA-7150 can also provide external GE interfaces, and FC interfaces.

Management functions The ATCA-7150 provides the IPMC that is powered independently. The IPMC is connected to the ShMC through the redundant IPMB.

The IPMC provides the following functions:

z Environmental sensors temperature, voltage

z System Event Logs

z Power-on, power-off, cold reset

z SOL(Serial Over LAN)

z FRU Hot-swap management

Integrity functions z Dual-channel GE controller

z SAS storage controller

Show 7 more labels / short text on this page
Function Description · z 1000Base-BX · z 1000Base-BX · z Watchdog timer · z E-Keying control · z IPMI · z Video controller
Page 26 of the Emerson ATCA-7150 user manual — 1.3 Ordering Information
Seite 26 · Zum Vergrößern klicken
Seite 26
Emerson ATCA-7150 — 1.2 Standard Compliances diagram (page 26)
Abb. 22 · 1.2 Standard Compliances

1.2 Standard Compliances

This product meets the following standards.

Table 1-2 Standard Compliances

Emerson ATCA-7150 — 1.2 Standard Compliances diagram (page 26)
Abb. 23 · 1.2 Standard Compliances

EMC requirements (legal) on system level (predefined Emerson Network Power system)

PICMG 3.0 Defines mechanics, blade dimensions, power distribution, power and data connectors, and system management

1.3 Ordering Information

When ordering board variants or board accessories, use the order numbers given on the following pages.

Page 27 of the Emerson ATCA-7150 user manual — 1.3.2 Board Accessories
Seite 27 · Zum Vergrößern klicken
Seite 27
Emerson ATCA-7150 — 1.3.1 Supported Board Models diagram (page 27)
Abb. 24 · 1.3.1 Supported Board Models

1.3.1 Supported Board Models

The following table explains the product nomenclature used for the available board variants.

Table 1-3 Product Nomenclature

Emerson ATCA-7150 — 1.3.1 Supported Board Models diagram (page 27)
Abb. 25 · 1.3.1 Supported Board Models

ATCA-7150-0GB ATCA Processor Blade with Dual Core Intel® Xeon® Processor LV5138.

Can be equipped with up to 16GB DDR2 memory.

ATCA-7X50-MEM-2G 2G Memory Module (min 1, max 4 modules of the same type per blade)

ATCA-7X50-MEM-4G 4G Memory Module (min 1, max 4 modules of the same type per blade)

RTM-ATCA-7150-GE Rear Transition Module for ATCA-7150, 2x 1G Ethernet

RTM-ATCA-7150-GE-FC Rear Transition Module for ATCA-7150, 2x 1G Eth, 2x FC

ATCA-7150-8GB-1HDD1 ATCA Processor Blade with Dual Core Intel® Xeon® Processor LV5138, 8GB (4x 2GB) Memory, 1x Enterprise Class HDD, SAS, 72GB

1.3.2 Board Accessories

As of the printing date of this manual, the following board accessories were available.

Table 1-4 Available Board Accessories

Emerson ATCA-7150 — 1.3.2 Board Accessories diagram (page 27)
Abb. 26 · 1.3.2 Board Accessories
Page 28 of the Emerson ATCA-7150 user manual — 1.3.1 Supported Board Models
Seite 28 · Zum Vergrößern klicken
Seite 28
Emerson ATCA-7150 — 1.3.1 Supported Board Models diagram (page 28)
Abb. 27 · 1.3.1 Supported Board Models

Table 1-4 Available Board Accessories (continued)

Emerson ATCA-7150 — 1.3.1 Supported Board Models diagram (page 28)
Abb. 28 · 1.3.1 Supported Board Models
Page 29 of the Emerson ATCA-7150 user manual — Shipment Inspection
Seite 29 · Zum Vergrößern klicken
Seite 29
Emerson ATCA-7150 — Installation of the RTM-ATCA-7150 diagram (page 29)
Abb. 29 · Installation of the RTM-ATCA-7150

2.1 Overview

This chapter describes:

z Unpacking and inspecting RTM-ATCA-7150

z Precautions during the operation

z Preparations before installation

z Installing and replacing daughter cards

z Connection of external cables

2.2 Unpacking and Inspecting RTM-ATCA-7150

Emerson ATCA-7150 — 2.2 Unpacking and Inspecting RTM-ATCA-7150 diagram (page 29)
Abb. 30 · 2.2 Unpacking and Inspecting RTM-ATCA-7150

Damage of Circuits Electrostatic discharge and incorrect installation and removal of the product can damage circuits or shorten their life. Before touching the product or electronic components, make sure that your are working in an ESD-safe environment.

Shipment Inspection

To inspect the shipment, perform the following steps.

1. Verify that you have received all items of your shipment: Printed "Getting Started" guide RTM-ATCA-7150 Any optional items ordered
2. Check for damage and report any damage or differences to the customer service.

z Installation procedure · z Removal procedure

Page 30 of the Emerson ATCA-7150 user manual — 2.3.1 Environmental Requirements
Seite 30 · Zum Vergrößern klicken
Seite 30
Emerson ATCA-7150 — 2.3 Environmental and Power Requirements diagram (page 30)
Abb. 31 · 2.3 Environmental and Power Requirements
3. Remove the desiccant bag shipped together with the blade and dispose of it according to your country’s legislation.

The product is thoroughly inspected before shipment. If any damage occurred during transportation or any items are missing, please contact our customer's service immediately.

2.3 Environmental and Power Requirements

The following environmental and power requirements are applicable to the board.

2.3.1 Environmental Requirements

Table 2-1 Environmental Requirements RTM-ATCA-7150

Temperature +5ºC (41ºF) to +40ºC (104ºF) (normal operation) according to NEBS Standard GR-63-CORE

-40ºC (-40ºF) to +70ºC (158ºF) (may be further limited by installed accessories)

-5ºC to +55ºC (short term operation) according to NEBS Standard GR-63-CORE

Temp. Change +/- 0.25ºC/min or 15ºC/h (59ºF/h) according to NEBS Standard GR-63-CORE

+/- 0.25ºC/min or 15ºC/h (59ºF/h)

Rel. Humidity 5% to 85% non-condensing according to Emerson Network Power Embedded Computing-internal environmental requirements

5% to 85% non-condensing according to Emerson Network Power Embedded Computing-internal environmental requirements

Requirement Operating Non-Operating · Altitude

Page 31 of the Emerson ATCA-7150 user manual — 2.3.2 Power Requirements
Seite 31 · Zum Vergrößern klicken
Seite 31
Emerson ATCA-7150 — 2.3.2 Power Requirements diagram (page 31)
Abb. 32 · 2.3.2 Power Requirements

Table 2-1 Environmental Requirements RTM-ATCA-7150 (continued)

Emerson ATCA-7150 — 2.3.2 Power Requirements diagram (page 31)
Abb. 33 · 2.3.2 Power Requirements

Vibration 1.0g from 5 to 100 Hz and back to 5 Hz at a rate of 0.1 octave/minute

Random 5-20 Hz @ 1 m2/Sec3

Shock Half-sine, 11 m/Sec, 30mSec/sec2 Blade level packaging

1.0m (Packaged) per ETSI 300 019-2-2 (Blade level packaging)

2.3.2 Power Requirements

Table 2-2 Power Requirements RTM-ATCA-7150

Emerson ATCA-7150 — 2.3.2 Power Requirements diagram (page 31)
Abb. 34 · 2.3.2 Power Requirements
Page 32 of the Emerson ATCA-7150 user manual — 2.4 Module Installation and Removal
Seite 32 · Zum Vergrößern klicken
Seite 32
Emerson ATCA-7150 — 2.4 Module Installation and Removal diagram (page 32)
Abb. 35 · 2.4 Module Installation and Removal

2.4 Module Installation and Removal

Emerson ATCA-7150 — 2.4 Module Installation and Removal diagram (page 32)
Abb. 36 · 2.4 Module Installation and Removal

Personal Damage through Electric Shock There is current in the power cords and communication cables. Touching the connectors of the power cords and communication cables may cause electric shock. Do not touch the connectors of power cords and communication cables

Emerson ATCA-7150 — 2.4 Module Installation and Removal diagram (page 32)
Abb. 37 · 2.4 Module Installation and Removal

Damage of Circuits Electrostatic discharge and incorrect installation and removal of the product can damage circuits or shorten their life. Before touching the product or electronic components, make sure that your are working in an ESD-safe environment.

Module Damage If the blade is not fully aligned with the interface in the backplane, too much force may twist the pins on the blade or backplane. Do not exert too much force when you insert the blade.

z Make sure that you wear an electrostatic discharge (ESD)-preventive wrist strap to prevent the static electricity from hurting you or damaging the device.

z Keep your personal objects such as your clothes away from RTM-ATCA-7150. To prevent the static electricity on clothing, you need to put on antistatic clothing.

z RTM-ATCA-7150 is installed in the slot paired with the server blade slot at the back side of the shelf. You should install RTM-ATCA-7150 before the server blade is installed. Otherwise, RTM-ATCA-7150 cannot be powered on normally.

Page 33 of the Emerson ATCA-7150 user manual — 2.4.2 ESD Prevention
Seite 33 · Zum Vergrößern klicken
Seite 33
Emerson ATCA-7150 — 2.4.1 Ejector Handles diagram (page 33)
Abb. 38 · 2.4.1 Ejector Handles

z Hold the ejector handles and the face plate when you insert or remove RTM-ATCA-7150. Do not touch the components inside of the blades.

z Keep the blade vertical when you install RTM-ATCA-7150. Align the blade with the slot and then insert it in the shelf.

2.4.1 Ejector Handles

RTM-ATCA-7150 is powered by the server blade in the slot paired with the RTM-ATCA-7150 slot. RTM-ATCA-7150 does not support hot swap. The face plate of ATCA-7150 and RTM-ATCA- 7150 provides an upper and a lower ejector handles. The ejector handles help to insert, remove, fasten, power on, and power off RTM-ATCA-7150.

2.4.2 ESD Prevention

Static electricity may hurt you or damage the device. To minimize the damage, pay attention to the following points:

z Before you operate the device, wear the ESD-preventive wrist strap. Both terminals of the ESD-preventive wrist strap must contact well. One terminal touches your bare skin, and the other is inserted in the jack at the front or back side of the shelf. For details on how to wear the ESD-preventive wrist strap, refer Wearing the ESD-Preventive Wrist Strap.

z Avoid moving your body as much as possible. Movement gathers static electricity around you.

z Do not touch the solder point, pin, or bare circuit.

z Do not leave the device in the place where others can operate it.

z Install the device at once after you take it out of the antistatic package. If you need to lay down the device, place it back in the antistatic package. Do not lay the device on the shelf or cabinet.

z Monitor the temperature and humidity of the equipment room. Warm air decreases the humidity and increases the static electricity in the room.

Page 34 of the Emerson ATCA-7150 user manual — 2.5.1 Wearing the ESD-Preventive Wrist Strap
Seite 34 · Zum Vergrößern klicken
Seite 34
Emerson ATCA-7150 — 2.5 Installation Preparations diagram (page 34)
Abb. 39 · 2.5 Installation Preparations

2.5 Installation Preparations

The installation preparations process includes:

z check the installation environment

z wear the ESD-preventive wrist strap

z remove the blank filler panels

z unpack and check the RTM-ATCA-7150 suite

2.5.1 Wearing the ESD-Preventive Wrist Strap

Emerson ATCA-7150 — 2.5.1 Wearing the ESD-Preventive Wrist Strap diagram (page 34)
Abb. 40 · 2.5.1 Wearing the ESD-Preventive Wrist Strap

z Electrostatic discharge can damage circuits or shorten their life.

z The ESD-preventive wrist strap prevents only the static electricity on your body from damaging the blade. To prevent the static electricity on your clothes, it is recommended to wear the antistatic clothes. Additionally, you have to make sure that the cabinet and shelf are properly grounded - for details, refer to the corresponding system documentation.

Page 35 of the Emerson ATCA-7150 user manual — Figure 2-1 Wearing the ESD-Preventive Wrist Strap
Seite 35 · Zum Vergrößern klicken
Seite 35
Emerson ATCA-7150 — Figure 2-1 Wearing the ESD-Preventive Wrist Strap diagram (page 35)
Abb. 41 · Figure 2-1 Wearing the ESD-Preventive Wrist Strap

To wear the ESD-preventive wrist strap, proceed as follows:

1. Wrap the ESD-preventive wrist strap around your wrist, as shown in the figure below.
2. Fasten the latch. Make sure that the ESD-preventive wrist strap well touches your bare wrist.
3. Insert the grounding terminal of the ESD-preventive wrist strap in the jack of the cabinet or shelf.

There is a jack for inserting the ESD-preventive wrist strap respectively in the lower right corners at both front and back sides of the shelf.

Figure 2-1 Wearing the ESD-Preventive Wrist Strap

Emerson ATCA-7150 — Figure 2-1 Wearing the ESD-Preventive Wrist Strap diagram (page 35)
Abb. 42 · Figure 2-1 Wearing the ESD-Preventive Wrist Strap
Page 36 of the Emerson ATCA-7150 user manual — 2.5.2 Removing Filler Blades
Seite 36 · Zum Vergrößern klicken
Seite 36
Emerson ATCA-7150 — 2.5.2 Removing Filler Blades diagram (page 36)
Abb. 43 · 2.5.2 Removing Filler Blades

2.5.2 Removing Filler Blades

After a filler blade is removed, place it in the equipment room or other moisture-proof and dust-proof places.

You should install a blank filler blade in the slot after removing the blade. Otherwise, it may effect the ventilation, heat dissipation, electromagnetic shielding and dust prevention of the shelf.

If this is the first installation for the shelf, the blade is fully configured and the shelf is not powered on, you can remove all the filler blades. Then, install blades in the slots in order. This document takes the first installation as an example.

If you want to install multiple blades in the shelf that is powered on shelf, you can remove a filler blade and then install a blade one by one.

If the slot is occupied with a filler blade you have to remove it first.

Page 37 of the Emerson ATCA-7150 user manual — 2.6 Installing and Replacing Daughter Cards
Seite 37 · Zum Vergrößern klicken
Seite 37
Emerson ATCA-7150 — Figure 2-2 Removing the Filler Blade diagram (page 37)
Abb. 44 · Figure 2-2 Removing the Filler Blade

To remove the filler blade, proceed as follows:

1. As shown in step 1 of the figure below, use a screwdriver to anticlockwise loosen the two captive screws on a filler blade.
2. As shown in step 2 of the figure below, remove the filler blade.

Figure 2-2 Removing the Filler Blade

Emerson ATCA-7150 — Figure 2-2 Removing the Filler Blade diagram (page 37)
Abb. 45 · Figure 2-2 Removing the Filler Blade

2.6 Installing and Replacing Daughter Cards

Page 38 of the Emerson ATCA-7150 user manual — 2.6.1 Precautions
Seite 38 · Zum Vergrößern klicken
Seite 38
Emerson ATCA-7150 — 2.6.1 Precautions diagram (page 38)
Abb. 46 · 2.6.1 Precautions

2.6.1 Precautions

Incorrect installation or removal of additional devices or modules may damage the product or the additional devices or modules. Before installing or removing additional devices or modules, read the respective documentation.

Electrostatic discharge and incorrect installation and removal of the product can damage circuits or shorten their life. Before touching the product or electronic components, make sure that your are working in an ESD-safe environment.

Do not exert too much force when you insert the blade. If the blade is not fully aligned with the interface in the backplane, too much force may twist the pins on the blade or backplane.

Emerson ATCA-7150 — 2.6.1 Precautions diagram (page 38)
Abb. 47 · 2.6.1 Precautions

Do not touch the connectors of power cords and communication cables. There is current in the power cords and communication cables. Touch on the connectors of the power cords and communication cables may cause electric shock.

z Make sure that you wear an electrostatic discharge (ESD)-preventive wrist strap to prevent the static electricity from hurting you or damaging the device.

z Keep the area where the components reside clean and keep the components away from the heat-generating devices, such as radiators.

Page 39 of the Emerson ATCA-7150 user manual — 2.6.2 Preparations
Seite 39 · Zum Vergrößern klicken
Seite 39
Emerson ATCA-7150 — 2.6.2 Preparations diagram (page 39)
Abb. 48 · 2.6.2 Preparations

z Ensure that your sleeves are tightened or rolled up above the elbow. For safety purpose, it is not recommended to wear jewelry, watch, glasses with metal frame, or clothes with metal buttons.

z Do not exert too much force, or insert or remove the components forcibly. Avoid damage to the components or plug-ins, for example, the pins are bent or get short circuit.

2.6.2 Preparations

Before you install or replace a component, make the following preparations

z Confirming the feasibility of the operation

— There are available spare parts of the component to be installed or replaced in the equipment warehouse. When the available spare parts are in short supply, contact Emerson Network Power Embedded Computing for help in time.

— Make sure that the new component is in good condition, without defects such as oxidation, chemical corrosion, missing component, or transportation damage.

— By reading this document, you are familiar with how to install and replace the component and master the skills required by the operation.

z Checking the environment Make sure that the shelf, power supply, temperature, and humidity meet the operating requirements of the blades and components. For details, refer to ATCA-7150 Installation and Use Manual and other related documents.

z Preparing spare parts and tools

— Prepare the component to be installed or replaced. When you hold or transport the component, use the special antistatic package. In addition, you need to tidy, record, and repair the component during routine maintenance.

— Prepare the cross screwdriver, screws, plastic supports, cooling gel, and ESD- preventive wrist strap. The supplier provides a list of tools and negotiates with you to decide the tool provider.

z Confirming installation or changing positions Confirm the positions of the cabinet, the shelf, and the slot where RTM-ATCA-7150 is installed. Then, stick a label on the face plate of RTM-ATCA-7150 to avoid wrong operation.

Page 40 of the Emerson ATCA-7150 user manual — 2.6.3 GE Daughter Card
Seite 40 · Zum Vergrößern klicken
Seite 40
Emerson ATCA-7150 — 2.6.3 GE Daughter Card diagram (page 40)
Abb. 49 · 2.6.3 GE Daughter Card

z Others If a serious problem occurs and cannot be solved when you install or replace the component, contact Emerson Network Power Embedded Computing for technical support.

2.6.3 GE Daughter Card

This manual considers the GE daughter card providing two external Ethernet interfaces as an example, and describes how to install the daughter card on and remove it from RTM-ATCA- 7150.

Page 41 of the Emerson ATCA-7150 user manual — 2.6.3.1 Installation Positions
Seite 41 · Zum Vergrößern klicken
Seite 41
Emerson ATCA-7150 — 2.6.3.1 Installation Positions diagram (page 41)
Abb. 50 · 2.6.3.1 Installation Positions

2.6.3.1 Installation Positions

When the GE daughter card is used with the RTM-ATCA-7150 it can be installed on the daughter card connector J1, J2, J3, J4. The default position as used on the RTM-ATCA-7150-GE is position J4. The default position as used on the RTM-ATCA-7150-GE-FC is position J1.

Figure 2-3 Structure of RTM-ATCA-7150

Emerson ATCA-7150 — 2.6.3.1 Installation Positions diagram (page 41)
Abb. 51 · 2.6.3.1 Installation Positions
Page 42 of the Emerson ATCA-7150 user manual — 2.6.3.2 Installing the GE Daughter Card
Seite 42 · Zum Vergrößern klicken
Seite 42
Emerson ATCA-7150 — 2.6.3.2 Installing the GE Daughter Card diagram (page 42)
Abb. 52 · 2.6.3.2 Installing the GE Daughter Card

2.6.3.2 Installing the GE Daughter Card

To install the GE daughter card, proceed as follows.

1. Wear the ESD-preventive wrist strap. For more information refer, Wearing the ESDPreventive Wrist Strap .
2. Lay RTM-ATCA-7150 where the GE daughter card is to be installed on the antistatic desktop.
3. As shown in step 1 of the figure below, insert two plastic supports vertically in the holes used to fasten the GE daughter card.
4. As shown in step 2 of the figure below, at the back side of RTM-ATCA-7150, use a screwdriver to clockwise fasten the two screws used to fix the plastic supports.
5. Take the GE daughter card out of the antistatic package.
Page 43 of the Emerson ATCA-7150 user manual — 2.6.3.2 Installing the GE Daughter Card
Seite 43 · Zum Vergrößern klicken
Seite 43
Emerson ATCA-7150 — 2.6.3.2 Installing the GE Daughter Card diagram (page 43)
Abb. 53 · 2.6.3.2 Installing the GE Daughter Card
6. Insert the GE daughter card in RTM-ATCA-7150 by facing the daughter card at an angle of 45° to the RTM. Align the daughter card connector with the connector on RTM-ATCA-7150, and the daughter card positioning holes with the plastic supports on RTM-ATCA-7150. Exert even power downwards until the daughter card connector is fully inserted into the connector on RTM-ATCA-7150 and the daughter
Page 44 of the Emerson ATCA-7150 user manual — Figure 2-4 Installing the GE Daughter Card
Seite 44 · Zum Vergrößern klicken
Seite 44
Emerson ATCA-7150 — Figure 2-4 Installing the GE Daughter Card diagram (page 44)
Abb. 54 · Figure 2-4 Installing the GE Daughter Card

card is fastened by the plastic latches. See step 3 in the figure below.

Figure 2-4 Installing the GE Daughter Card

Emerson ATCA-7150 — Figure 2-4 Installing the GE Daughter Card diagram (page 44)
Abb. 55 · Figure 2-4 Installing the GE Daughter Card
Page 45 of the Emerson ATCA-7150 user manual — 2.6.3.3 Replacing the GE Daughter Card
Seite 45 · Zum Vergrößern klicken
Seite 45
Emerson ATCA-7150 — 2.6.3.3 Replacing the GE Daughter Card diagram (page 45)
Abb. 56 · 2.6.3.3 Replacing the GE Daughter Card
7. Insert RTM-ATCA-7150 with the GE daughter card installed in the shelf. For more information refer, Installing RTM-ATCA-7150 .

After installation, check if RTM-ATCA-7150 can be powered on and work normally. Use the network cable to connect RTM-ATCA-7150 to the external network. Check if the network is connected properly and monitor whether the network port indicator is normal.

2.6.3.3 Replacing the GE Daughter Card

To replace the GE daughter card, proceed as follows.

1. Wear the ESD-preventive wrist strap. For more information refer, Wearing the ESDPreventive Wrist Strap .
2. Remove the RTM-ATCA-7150 whose GE daughter card is to be replaced. For more information refer, Removing RTM-ATCA-7150 .
3. As shown in step 1 of the figure below, open the plastic latches fastening the GE daughter card.
4. Exert even force upwards until the daughter card connector is removed from the connector on RTM-ATCA-7150. As shown in step 2 of the figure below, remove the daughter card by facing the daughter card at an angle of 45° to the RTM.
5. Place the removed GE daughter card in an antistatic package.
Page 46 of the Emerson ATCA-7150 user manual — Figure 2-5 Replacing the GE Daughter Card.
Seite 46 · Zum Vergrößern klicken
Seite 46
Emerson ATCA-7150 — Figure 2-5 Replacing the GE Daughter Card. diagram (page 46)
Abb. 57 · Figure 2-5 Replacing the GE Daughter Card.
6. Take the new GE daughter card out of the antistatic package.

Figure 2-5 Replacing the GE Daughter Card.

Emerson ATCA-7150 — Figure 2-5 Replacing the GE Daughter Card. diagram (page 46)
Abb. 58 · Figure 2-5 Replacing the GE Daughter Card.
Page 47 of the Emerson ATCA-7150 user manual — 2.6.4.2 Installing the FC Daughter Card
Seite 47 · Zum Vergrößern klicken
Seite 47
Emerson ATCA-7150 — 2.6.4 FC Daughter Card diagram (page 47)
Abb. 59 · 2.6.4 FC Daughter Card
7. Insert the GE daughter card in RTM-ATCA-7150 by facing the daughter card at an angle of 45° to the RTM. Align the daughter card connector with the connector on RTM-ATCA-7150, and the daughter card positioning holes with the plastic supports on RTM-ATCA-7150. Exert even power downwards until the daughter card connector is fully inserted into the connector on RTM-ATCA-7150 and the daughter card is fastened by the plastic latches. See step 3 in the figure above.
8. Install RTM-ATCA-7150 whose GE daughter card is replaced. For more information refer, Installing RTM-ATCA-7150 .

After replacement, check if RTM-ATCA-7150 can be powered on and work normally. Use the network cable to connect RTM-ATCA-7150 to the external network. Check if the network is connected properly and monitor whether the network port indicator is normal.

2.6.4 FC Daughter Card

This manual considers the FC daughter card providing two external FC interfaces as an example, and describes how to install the daughter card on and remove it from RTM-ATCA- 7150.

2.6.4.1 Installation Positions

When the FC daughter card is used with the RTM-ATCA-7150 it can be installed on the daughter card connector J2, J4. The default position as used on the RTM-ATCA-7150-GE-FC is position J4 and J1.

2.6.4.2 Installing the FC Daughter Card

To install the FC daughter card, proceed as follows.

1. Wear the ESD-preventive wrist strap. For more information refer, Wearing the ESDPreventive Wrist Strap .
2. Lay RTM-ATCA-7150 where the FC daughter card is to be installed on the antistatic desktop.
Page 48 of the Emerson ATCA-7150 user manual — 2.6.4 FC Daughter Card
Seite 48 · Zum Vergrößern klicken
Seite 48
Emerson ATCA-7150 — 2.6.4 FC Daughter Card diagram (page 48)
Abb. 60 · 2.6.4 FC Daughter Card
3. As shown in step 1 of the figure below, insert two plastic supports vertically in the holes used to fasten the FC daughter card.
4. As shown in step 2 of the figure below, at the back side of RTM-ATCA-7150, use a screwdriver to clockwise fasten the two screws used to fix the plastic supports.
5. Take the FC daughter card out of the antistatic package.
Page 49 of the Emerson ATCA-7150 user manual — 2.6.4 FC Daughter Card
Seite 49 · Zum Vergrößern klicken
Seite 49
Emerson ATCA-7150 — 2.6.4 FC Daughter Card diagram (page 49)
Abb. 61 · 2.6.4 FC Daughter Card
6. Insert the GE daughter card in RTM-ATCA-7150 by facing the daughter card at an angle of 45° to the RTM. Align the daughter card connector with the connector on RTM-ATCA-7150, and the daughter card positioning holes with the plastic supports on RTM-ATCA-7150. Exert even power downwards until the daughter card connector is fully inserted into the connector on RTM-ATCA-7150 and the daughter
Page 50 of the Emerson ATCA-7150 user manual — Figure 2-6 Installing the FC Daughter Card
Seite 50 · Zum Vergrößern klicken
Seite 50
Emerson ATCA-7150 — Figure 2-6 Installing the FC Daughter Card diagram (page 50)
Abb. 62 · Figure 2-6 Installing the FC Daughter Card

card is fastened by the plastic latches. See step 3 in the figure below.

Figure 2-6 Installing the FC Daughter Card

Emerson ATCA-7150 — Figure 2-6 Installing the FC Daughter Card diagram (page 50)
Abb. 63 · Figure 2-6 Installing the FC Daughter Card
7. Insert RTM-ATCA-7150 with the FC daughter card installed in the shelf. For more
Page 51 of the Emerson ATCA-7150 user manual — 2.6.4.3 Replacing the FC Daughter Card
Seite 51 · Zum Vergrößern klicken
Seite 51
Emerson ATCA-7150 — 2.6.4.3 Replacing the FC Daughter Card diagram (page 51)
Abb. 64 · 2.6.4.3 Replacing the FC Daughter Card

information refer, Installing RTM-ATCA-7150.

After installation, check if RTM-ATCA-7150 can be powered on and work normally. Use the optical fiber to connect RTM-ATCA-7150 to the external storage system. Check if RTM-ATCA- 7150 can transmit data normally and monitor whether the FC status indicator is normal.

2.6.4.3 Replacing the FC Daughter Card

To replace the FC daughter card, proceed as follows.

1. Wear the ESD-preventive wrist strap. For more information refer, Wearing the ESDPreventive Wrist Strap .
2. Remove the RTM-ATCA-7150 whose FC daughter card is to be replaced. For more information refer, Removing RTM-ATCA-7150 .
3. As shown in step 1 of the figure below, open the plastic latches fastening the FC daughter card.
4. Exert even force upwards until the daughter card connector is removed from the connector on RTM-ATCA-7150. As shown in step 2 of the figure below, remove the daughter card by facing the daughter card at an angle of 45° to the RTM.
5. Place the removed FC daughter card in an antistatic package.
Page 52 of the Emerson ATCA-7150 user manual — Figure 2-7 Replacing the FC Daughter Card.
Seite 52 · Zum Vergrößern klicken
Seite 52
Emerson ATCA-7150 — Figure 2-7 Replacing the FC Daughter Card. diagram (page 52)
Abb. 65 · Figure 2-7 Replacing the FC Daughter Card.
6. Take the new FC daughter card out of the antistatic package.

Figure 2-7 Replacing the FC Daughter Card.

Emerson ATCA-7150 — Figure 2-7 Replacing the FC Daughter Card. diagram (page 52)
Abb. 66 · Figure 2-7 Replacing the FC Daughter Card.
Page 53 of the Emerson ATCA-7150 user manual — 2.7.1 Installing RTM-ATCA-7150
Seite 53 · Zum Vergrößern klicken
Seite 53
Emerson ATCA-7150 — 2.7 Installing and Removing the RTM-ATCA-7150 diagram (page 53)
Abb. 67 · 2.7 Installing and Removing the RTM-ATCA-7150
7. Insert the FC daughter card in RTM-ATCA-7150 by facing the daughter card at an angle of 45° to the RTM. Align the daughter card connector with the connector on RTM-ATCA-7150, and the daughter card positioning holes with the plastic supports on RTM-ATCA-7150. Exert even power downwards until the daughter card connector is fully inserted into the connector on RTM-ATCA-7150 and the daughter card is fastened by the plastic latches. See step 3 in the figure above.
8. Install RTM-ATCA-7150 whose FC daughter card is replaced. For more information refer, Installing RTM-ATCA-7150 .

After replacement, check if RTM-ATCA-7150 can be powered on and work normally. Use the optical fibre to connect RTM-ATCA-7150 to the external storage system. Check if RTM-ATCA- 7150 can transmit data normally and monitor whether the FC status indicator is normal.

2.7 Installing and Removing the RTM-ATCA-7150

2.7.1 Installing RTM-ATCA-7150

Emerson ATCA-7150 — 2.7.1 Installing RTM-ATCA-7150 diagram (page 53)
Abb. 68 · 2.7.1 Installing RTM-ATCA-7150

Product Damage You can install RTM-ATCA-7150 into a system if the front blade is already installed or if it is not installed. In case the front blade is already installed, its payload has to be powered down first.

Page 54 of the Emerson ATCA-7150 user manual — Installation Procedure with Installed Front Blade
Seite 54 · Zum Vergrößern klicken
Seite 54
Emerson ATCA-7150 — 2.7 Installing and Removing the RTM-ATCA-7150 diagram (page 54)
Abb. 69 · 2.7 Installing and Removing the RTM-ATCA-7150

Installation Procedure with Installed Front Blade

The following procedure describes the installation of RTM-ATCA-7150. It assumes that your system is powered on. If your system is powered off, you can disregard the blue LED and thus skip the respective step. In this case it is a purely mechanical installation. The same applies to an installation without an installed front blade. In this case disregard the LEDs and skip the respective step.

1. Wear the ESD-preventive wrist strap. For more information refer, Wearing the ESDPreventive Wrist Strap .
2. Fully open the ejector handles of the front blade.
3. Take RTM-ATCA-7150 out of the antistatic package.
4. Fully open the upper and lower ejector handles of the RTM.
Page 55 of the Emerson ATCA-7150 user manual — Figure 2-8 Installing RTM-ATCA-7150
Seite 55 · Zum Vergrößern klicken
Seite 55
Emerson ATCA-7150 — Figure 2-8 Installing RTM-ATCA-7150 diagram (page 55)
Abb. 70 · Figure 2-8 Installing RTM-ATCA-7150
5. As shown in step 1 of the figure below, align the upper and lower sides of RTMATCA-7150 with the guide rails (the edges of the slot). Slide RTM-ATCA-7150 along the guide rails until the positioning pins of RTM-ATCA-7150 are inserted in the positioning holes in the shelf. The LEDs; OOS LED, Blue LED, and healthy LED are on.

Figure 2-8 Installing RTM-ATCA-7150

Emerson ATCA-7150 — Figure 2-8 Installing RTM-ATCA-7150 diagram (page 55)
Abb. 71 · Figure 2-8 Installing RTM-ATCA-7150
6. As shown in step 2 of the figure above, make sure that the ejector handles are fastened to the beam. Close the upper and lower ejector handles inwards until the inner sides of the ejector handles are attached to the face plate.
7. As shown in step 3 of the figure above, use the screwdriver to fasten the captive screws clockwise to fix RTM-ATCA-7150. The LEDs of the RTM are off now.
8. Close the handles of the front blades
Page 56 of the Emerson ATCA-7150 user manual — 2.7.2 Removing RTM-ATCA-7150
Seite 56 · Zum Vergrößern klicken
Seite 56
Emerson ATCA-7150 — 2.7.2 Removing RTM-ATCA-7150 diagram (page 56)
Abb. 72 · 2.7.2 Removing RTM-ATCA-7150

2.7.2 Removing RTM-ATCA-7150

Emerson ATCA-7150 — 2.7.2 Removing RTM-ATCA-7150 diagram (page 56)
Abb. 73 · 2.7.2 Removing RTM-ATCA-7150

Product Damage You should power off the front blade before removing RTM-ATCA-7150.

To remove RTM-ATCA-7150, proceed as follows:

1. Wear the ESD-preventive wrist strap. For more information refer, Wearing the ESDPreventive Wrist Strap .
2. The OOS, blue, and the healthy LEDs of the RTM are on. Open the ejector handles of the front blade to power it down.
3. As shown in step 2 of the figure below, use the screwdriver to unfasten the captive screws of the RTM anticlockwise.
4. As shown in step 1 of the figure below, fully open the upper and lower ejector handles.
Page 57 of the Emerson ATCA-7150 user manual — 2.8 Connecting External Cables
Seite 57 · Zum Vergrößern klicken
Seite 57
Emerson ATCA-7150 — Figure 2-9 Removing RTM-ATCA-7150 diagram (page 57)
Abb. 74 · Figure 2-9 Removing RTM-ATCA-7150
5. As shown in step 3 of the figure below, remove RTM-ATCA-7150 along the guide rails.
6. Place RTM-ATCA-7150 in the antistatic package.

Figure 2-9 Removing RTM-ATCA-7150

Emerson ATCA-7150 — Figure 2-9 Removing RTM-ATCA-7150 diagram (page 57)
Abb. 75 · Figure 2-9 Removing RTM-ATCA-7150

2.8 Connecting External Cables

After RTM-ATCA-7150 is installed in the shelf, you can connect the keyboard, video, and mouse (KVM) cables.

Page 58 of the Emerson ATCA-7150 user manual — 2.8.1 Connecting KVM Cables
Seite 58 · Zum Vergrößern klicken
Seite 58
Emerson ATCA-7150 — 2.8.1 Connecting KVM Cables diagram (page 58)
Abb. 76 · 2.8.1 Connecting KVM Cables

If RTM-ATCA-7150 is configured with the GE daughter card and FC daughter card, it provides the external GE network ports and external FC interfaces. Network cables and optical fibers can be connected to RTM-ATCA-7150. You can choose to use one or more daughter cards according to actual applications.

Emerson ATCA-7150 — 2.8.1 Connecting KVM Cables diagram (page 58)
Abb. 77 · 2.8.1 Connecting KVM Cables

z There is a back cable trough at the back side of the shelf. You need to arrange and identify all cables and then bind and fasten them in the back cable through after connecting them.

z If you use excessive force when installing cables, the cables may be damaged.

z Do not exert too much force when you insert or remove the cables. Do not twist or tear the cables in any condition.

2.8.1 Connecting KVM Cables

The figure below shows the method of connecting the Keyboard, Video, Mouse (KVM) cables to RTM-ATCA-7150. Please refer to your local Emerson sales representative to obtain the cable.

Emerson ATCA-7150 — 2.8.1 Connecting KVM Cables diagram (page 58)
Abb. 78 · 2.8.1 Connecting KVM Cables

Product Damage You have to use matching interfaces for the KVM cables. Use a PS/2-USB converter when connecting the KVM cables.

Page 59 of the Emerson ATCA-7150 user manual — 2.8.2 Connecting Network Cables
Seite 59 · Zum Vergrößern klicken
Seite 59
Emerson ATCA-7150 — Figure 2-10 Connecting the KVM Cables to RTM-ATCA-7150 diagram (page 59)
Abb. 79 · Figure 2-10 Connecting the KVM Cables to RTM-ATCA-71…

Figure 2-10 Connecting the KVM Cables to RTM-ATCA-7150

Emerson ATCA-7150 — Figure 2-10 Connecting the KVM Cables to RTM-ATCA-7150 diagram (page 59)
Abb. 80 · Figure 2-10 Connecting the KVM Cables to RTM-ATCA-71…

2.8.2 Connecting Network Cables

Emerson ATCA-7150 — 2.8.2 Connecting Network Cables diagram (page 59)
Abb. 81 · 2.8.2 Connecting Network Cables

Electromagnetic Radiation Make sure that the cable and connectors of the network cable are with shielding function and that both ends of the shielded layer of the network cable are grounded. It is recommended that the network cable is grounded through the metal cover of the network port connector.

When RTM-ATCA-7150 is configured with the GE daughter card, it provides two external Ethernet interfaces with 10/100/1000M Base-T auto-negotiation. Network cables are used to connect RTM-ATCA-7150 to the external network. Please refer to your local Emerson sales representative to obtain the cable.

Page 60 of the Emerson ATCA-7150 user manual — 2.8.3 Connecting Optical Fibers
Seite 60 · Zum Vergrößern klicken
Seite 60
Emerson ATCA-7150 — Figure 2-11 Connecting the Network Cables to RTM-ATCA-7150 diagram (page 60)
Abb. 82 · Figure 2-11 Connecting the Network Cables to RTM-ATC…

The figure below shows the method of connecting the network cables to RTM-ATCA-7150.

Figure 2-11 Connecting the Network Cables to RTM-ATCA-7150

Emerson ATCA-7150 — Figure 2-11 Connecting the Network Cables to RTM-ATCA-7150 diagram (page 60)
Abb. 83 · Figure 2-11 Connecting the Network Cables to RTM-ATC…

2.8.3 Connecting Optical Fibers

When RTM-ATCA-7150 is configured with the FC daughter card, it provides two external 2G FC interfaces. Optical fibers are used to connect RTM-ATCA-7150 to the external Storage Area Network (SAN) storage system. Please refer to your local Emerson sales representative to obtain the cable.

Page 61 of the Emerson ATCA-7150 user manual — Figure 2-12 Connecting the Optical Fibers to RTM-ATCA-7150
Seite 61 · Zum Vergrößern klicken
Seite 61
Emerson ATCA-7150 — Figure 2-12 Connecting the Optical Fibers to RTM-ATCA-7150 diagram (page 61)
Abb. 84 · Figure 2-12 Connecting the Optical Fibers to RTM-ATC…

As shown in steps 1 and 2 in the figure below, insert the optical module in the FC interface and then insert the optical fibers in the optical module.

Figure 2-12 Connecting the Optical Fibers to RTM-ATCA-7150

Emerson ATCA-7150 — Figure 2-12 Connecting the Optical Fibers to RTM-ATCA-7150 diagram (page 61)
Abb. 85 · Figure 2-12 Connecting the Optical Fibers to RTM-ATC…
Page 62 of the Emerson ATCA-7150 user manual — Figure 2-12 Connecting the Optical Fibers to RTM-ATCA-7150
Seite 62 · Zum Vergrößern klicken
Seite 62
Emerson ATCA-7150 — Figure 2-12 Connecting the Optical Fibers to RTM-ATCA-7150 diagram (page 62)
Abb. 86 · Figure 2-12 Connecting the Optical Fibers to RTM-ATC…
Page 63 of the Emerson ATCA-7150 user manual — 3.2 Unpacking and Inspecting the Blade
Seite 63 · Zum Vergrößern klicken
Seite 63
Emerson ATCA-7150 — Hardware Installation of ATCA-7150 diagram (page 63)
Abb. 87 · Hardware Installation of ATCA-7150

3.1 Overview

This chapter describes:

z Unpacking and inspecting the blade

z Environmental and power requirements

z Precautions during the operation

z Checking the installation environment

z Installation and removal procedures

3.2 Unpacking and Inspecting the Blade

Emerson ATCA-7150 — 3.2 Unpacking and Inspecting the Blade diagram (page 63)
Abb. 88 · 3.2 Unpacking and Inspecting the Blade

Damage of Circuits Electrostatic discharge and incorrect installation and removal of the blade can damage circuits or shorten their life. Before touching the blade or electronic components, make sure that you are working in an ESD-safe environment.

To inspect the shipment, perform the following steps.

1. Verify that you have received all items of your shipment: Printed "Getting Started" guide ATCA-7150 blade Any optional items ordered
2. Check for damage and report any damage or differences to the customer service.

z Installing accessories · z Ejector handles · Shipment Inspection

Page 64 of the Emerson ATCA-7150 user manual — Table 3-1 List of Packing Items
Seite 64 · Zum Vergrößern klicken
Seite 64
Emerson ATCA-7150 — Table 3-1 List of Packing Items diagram (page 64)
Abb. 89 · Table 3-1 List of Packing Items
3. Remove the desiccant bag shipped together with the blade and dispose of it

according to your country’s legislation.

The blade is thoroughly inspected before shipment. If any damage occurred during transportation or any items are missing, please contact our customer's service immediately.

To unpack and check the ATCA-7150 suite, proceed as follows:

1. Wear the ESD-preventive wrist strap. For more details, see Wearing the ESD-Preventive Wrist Strap on page 75 .
2. Lay the packing carton according to the arrow direction on the cover.
3. Cut the tape to open the packing carton.
4. According to Table 3-1 , check that the components are complete and in good condition, without defects such as oxidation, chemical corrosion, missing component, or transportation damage.

Table 3-1 List of Packing Items

Emerson ATCA-7150 — Table 3-1 List of Packing Items diagram (page 64)
Abb. 90 · Table 3-1 List of Packing Items

1 Packing materials, such as packing carton, plastic package, and foam

2 Documentation bag, containing documents shipped with the product

3 ATCa-7150, which can be used with an RTM-ATCA-7150

4 RTM-ATCA-7150, which must be used with an ATCA-7150

z The actual items in the packing carton are decided by the contract.

z If you do not order an RTM of the server blade, all functions provided by the RTM are not available.

Unpacking the Blade

Page 65 of the Emerson ATCA-7150 user manual — 3.3.1 Environmental Requirements
Seite 65 · Zum Vergrößern klicken
Seite 65
Emerson ATCA-7150 — 3.3 Environmental and Power Requirements diagram (page 65)
Abb. 91 · 3.3 Environmental and Power Requirements

3.3 Environmental and Power Requirements

The following environmental and power rewuirements are applicable to the blade.

3.3.1 Environmental Requirements

Table 3-2 Environmental Requirements

Emerson ATCA-7150 — 3.3.1 Environmental Requirements diagram (page 65)
Abb. 92 · 3.3.1 Environmental Requirements

Temperature +5ºC (41ºF) to +40ºC (105ºF) (normal operation) according to NEBS Standard GR- 63-CORE

The SAS drives can meet this max temperature range of non-operating.

-5ºC to +55ºC (exceptional operation) according to NEBS Standard GR-63-CORE

Temp. Change +/- 0.25ºC/min according to NEBS Standard GR-63-CORE

Rel. Humidity 5% to 85% non-condensing according to Emerson Network Power-internal environmental requirements

5% to 95% non-condensing according to Emerson Network Power-internal environmental requirements

Vibration 0.1g from 5 to 100 Hz and back to 5 Hz at a rate of 0.1 octave/minute

Random 5-20 Hz at 1 m2/Sec3

Shock Half-sine, 11 m/Sec, 30mSec/sec2 Blade level packaging

Page 66 of the Emerson ATCA-7150 user manual — 3.3.2 Power Requirements
Seite 66 · Zum Vergrößern klicken
Seite 66
Emerson ATCA-7150 — 3.3.2 Power Requirements diagram (page 66)
Abb. 93 · 3.3.2 Power Requirements

Table 3-2 Environmental Requirements (continued)

Emerson ATCA-7150 — 3.3.2 Power Requirements diagram (page 66)
Abb. 94 · 3.3.2 Power Requirements

Free Fall 1,200 mm (Packaged) /all edges and corners

1.0m (Packaged) per ETSI 300 019-2-2 (Blade level packaging)

3.3.2 Power Requirements

Make sure that the blade is used in an AdvancedTCA shelf connected to -48VDC up to -60VDC, according to Telecommunication Network Voltage (TNV-2). A TNV-2 circuit is a circuit whose normal operating voltages exceed the limits for a safety-extra-low-voltage (SELV) under normal operating conditions, and which is not subject to overvoltages from telecommunication networks.

Table 3-3 lists the power requirements for the ATCA-7150.

Table 3-3 Power Requirements

Emerson ATCA-7150 — 3.3.2 Power Requirements diagram (page 66)
Abb. 95 · 3.3.2 Power Requirements

The blade provides two independent power inputs according to the AdvancedTCA specification.

Page 67 of the Emerson ATCA-7150 user manual — 3.4 Precautions
Seite 67 · Zum Vergrößern klicken
Seite 67
Emerson ATCA-7150 — 3.4 Precautions diagram (page 67)
Abb. 96 · 3.4 Precautions

3.4 Precautions

Electric Shock There is current in the power cords and communication cables. Touching the connectors of the power cords and communication cables may cause electric shock. Do not touch the connectors of power cords and communication cables.

Electrostatic Discharge Do not touch the circuit board with bare hands. The static electricity of the human body may damage the electrostatic sensitive devices (ESSDs) on the circuit board. Make sure that you wear an electrostatic discharge (ESD)-preventive wrist strap or antistatic glove to prevent the static electricity from hurting you or damaging the device. Keep your personal objects such as your clothes away from the ATCA-7150 suite. To prevent the static electricity from damaging the device, it is recommended to wear antistatic clothes.

Pin Damage If the blade is not fully aligned with the interface in the backplane, too much force may twist the pins on the blade or backplane. Do not exert too much force when you insert the blade.

z If an RTM is planned to be used, you must install the RTM in the slot before installing the ATCA-7150 in the paired slot. If the ATCA-7150 is installed first and shelf power is turned on the RTM must not be installed in the paired slot.

z To take the ATCA-7150 suite, hold the captive screw on the top of the face plate with one hand and the lower edge of the blade with the other hand. Do not touch the components of the blade.

Page 68 of the Emerson ATCA-7150 user manual — 3.4.1 ESD Prevention
Seite 68 · Zum Vergrößern klicken
Seite 68
Emerson ATCA-7150 — 3.4.1 ESD Prevention diagram (page 68)
Abb. 97 · 3.4.1 ESD Prevention

3.4.1 ESD Prevention

Static electricity may hurt you or damage the device. To minimize the damage, pay attention to the following points:

z Before you operate the device, wear the ESD-preventive wrist strap. Both terminals of the ESD-preventive wrist strap must contact well. One terminal touches your bare skin, and the other is inserted in the jack at the front or back side of the shelf. For details on how to wear the ESD-preventive wrist strap, see Wearing the ESD-Preventive Wrist Strap on page 75.

z Avoid moving as much as possible. Movement gathers static electricity around you.

z Do not touch the solder point, pin, or bare circuit.

z Do not leave the device in the place where others can operate it.

z Install the device at once after you take it out of the antistatic package. If you need to lay down the device, place it back in the antistatic package. Do not lay the device on the shelf or cabinet.

z Monitor the temperature and humidity of the equipment room. Warm air decreases the humidity but increases the static electricity in the room.

Emerson ATCA-7150 — 3.4.1 ESD Prevention diagram (page 68)
Abb. 98 · 3.4.1 ESD Prevention

Damage of Circuits Electrostatic discharge and incorrect module installation and removal can damage circuits or shorten their life. Before touching the module or electronic components, make sure that you are working in an ESD-safe environment.

Page 69 of the Emerson ATCA-7150 user manual — 3.5.1 Wearing the ESD-Preventive Wrist Strap
Seite 69 · Zum Vergrößern klicken
Seite 69
Emerson ATCA-7150 — 3.5 Checking the Installation Environment diagram (page 69)
Abb. 99 · 3.5 Checking the Installation Environment

3.5 Checking the Installation Environment

Table 3-4 lists the environment for installing the ATCA-7150 suite.

Table 3-4 Environment for Installing the ATCA-7150 Suite

Emerson ATCA-7150 — 3.5 Checking the Installation Environment diagram (page 69)
Abb. 100 · 3.5 Checking the Installation Environment

Leave enough space around the cabinet. Nothing blocks the fans and air conditioner to ensure airflow and heat dissipation.

Consider heat dissipation when you choose slots to install blades. If the shelf is not fully configured, install the blades in scattered slots.

3.5.1 Wearing the ESD-Preventive Wrist Strap

Emerson ATCA-7150 — 3.5.1 Wearing the ESD-Preventive Wrist Strap diagram (page 69)
Abb. 101 · 3.5.1 Wearing the ESD-Preventive Wrist Strap

Product Damage Electrostatic discharge can damage circuits or shorten their life. The ESD-preventive wrist strap prevents only the static electricity on your body from damaging the blade. To prevent the static electricity on your clothes, it is recommended to wear the antistatic clothes. Additionally, you have to make sure that the cabinet and shelf are properly grounded - for details, refer to the respective system documentation.

The cable of an ESD-preventive wrist strap is limited. In this case, before you wear the ESD- preventive wrist strap, place the device within 0.5 m away from the shelf.

Page 70 of the Emerson ATCA-7150 user manual — Figure 3-1 Wearing the ESD-Preventive Wrist Strap
Seite 70 · Zum Vergrößern klicken
Seite 70
Emerson ATCA-7150 — Figure 3-1 Wearing the ESD-Preventive Wrist Strap diagram (page 70)
Abb. 102 · Figure 3-1 Wearing the ESD-Preventive Wrist Strap

To wear the ESD-preventive wrist strap, proceed as follows:

1. Wrap the ESD-preventive wrist strap around your wrist, as shown in Figure 3-1 .
2. Fasten the latch. Make sure that the ESD-preventive wrist strap well touches your bare wrist.
3. Insert the grounding terminal of the ESD-preventive wrist strap in the jack of the cabinet or shelf.

Figure 3-1 Wearing the ESD-Preventive Wrist Strap

Emerson ATCA-7150 — Figure 3-1 Wearing the ESD-Preventive Wrist Strap diagram (page 70)
Abb. 103 · Figure 3-1 Wearing the ESD-Preventive Wrist Strap
Page 71 of the Emerson ATCA-7150 user manual — 3.5.2 Removing Blank Filler Blades
Seite 71 · Zum Vergrößern klicken
Seite 71
Emerson ATCA-7150 — 3.5.2 Removing Blank Filler Blades diagram (page 71)
Abb. 104 · 3.5.2 Removing Blank Filler Blades

3.5.2 Removing Blank Filler Blades

z After you remove a blank filler blade, store it in the equipment room or a damp-proof and dust-proof place.

z After you remove a blade from the shelf, install a blank filler blade in vacant slot. Otherwise, the functions such as ventilation, heat dissipation, electromagnetic shield, and dust proof may be affected.

z For a newly-delivered shelf, you can remove all blank filler blades and then install blades in all slots when the shelf is not powered on.

z If a shelf is powered on, you can remove a blank filler blade and then install a blade. In this way, install multiple blades one by one.

Page 72 of the Emerson ATCA-7150 user manual — 3.6 Installing Blade Accessories
Seite 72 · Zum Vergrößern klicken
Seite 72
Emerson ATCA-7150 — Figure 3-2 Removing the Blank filler blade diagram (page 72)
Abb. 105 · Figure 3-2 Removing the Blank filler blade

Before you install the ATCA-7150 suite, remove blank filler blades from installation slots as follows:

1. Use a screwdriver to anticlockwise loosen the two captive screws on a blank filler blade, as shown in Figure 3-2 .
2. Pull the blank filler blade out of the slot, as shown in Figure 3-2 .

Figure 3-2 Removing the Blank filler blade

Emerson ATCA-7150 — Figure 3-2 Removing the Blank filler blade diagram (page 72)
Abb. 106 · Figure 3-2 Removing the Blank filler blade

3.6 Installing Blade Accessories

Page 73 of the Emerson ATCA-7150 user manual — 3.6.2 Optional Components Supported by the ATCA-7150
Seite 73 · Zum Vergrößern klicken
Seite 73
Emerson ATCA-7150 — 3.6.1 Precautions diagram (page 73)
Abb. 107 · 3.6.1 Precautions

3.6.1 Precautions

Emerson ATCA-7150 — 3.6.1 Precautions diagram (page 73)
Abb. 108 · 3.6.1 Precautions

Electric Shock There is current in the power cords and communication cables. Touching the connectors of the power cords and communication cables may cause electric shock. Do not touch the connectors of power cords and communication cables.

When you install or replace components, pay attention to the following points:

z Wear the ESD-preventive wrist strap to prevent the static electricity from damaging the device.

z Keep the area where the components reside clean and keep the components away from the heat generating devices, such as radiator.

z Ensure that your sleeves are tightened or rolled up above the elbow. For safety purpose, it is not recommended to wear jewelry, watch, glasses with metal frame, or clothes with metal buttons.

z Do not exert too much force, or insert or remove the components forcibly. Avoid damage to the components or plug-ins.

3.6.2 Optional Components Supported by the ATCA-7150

Emerson ATCA-7150 — 3.6.2 Optional Components Supported by the ATCA-7150 diagram (page 73)
Abb. 109 · 3.6.2 Optional Components Supported by the ATCA-7150

Only those who are certificated or authorized by Emerson Network Power can replace or change the components.

Page 74 of the Emerson ATCA-7150 user manual — 3.6.3 Preparations
Seite 74 · Zum Vergrößern klicken
Seite 74
Emerson ATCA-7150 — Table 3-5 Optional Components Supported by the ATCA-7150 Suite diagram (page 74)
Abb. 110 · Table 3-5 Optional Components Supported by the ATCA-…

Table 3-5 lists the optional components supported by the ATCA-7150.

Table 3-5 Optional Components Supported by the ATCA-7150 Suite

Emerson ATCA-7150 — Table 3-5 Optional Components Supported by the ATCA-7150 Suite diagram (page 74)
Abb. 111 · Table 3-5 Optional Components Supported by the ATCA-…

For more information on the daughter cards, refer to RTM-ATCA-7150 Installation and Use Manual, MESC-RTM-7150-FC Installation Information, and MESC-RTM-7150-GE Installation Information.

3.6.3 Preparations

Before you install or replace the component, make the following preparations:

z Confirming the feasibility of the operation

— There are available spare parts of the component to be installed or replaced in the equipment warehouse. When the available spare parts are lacking, contact Emerson Network Power for help in time. For details on how to get help from Emerson Network Power, see Contacting Emerson Network Power for Technical Support on page 100.

— Make sure that the new component is in good condition, without defects such as oxidation, chemical corrosion, missing component, or transportation damage.

— By reading this document, you are familiar with how to install and replace the component and master the skills required by the operation.

z Checking the environment Make sure that the shelf, power supply, temperature, and humidity meet the operating requirement for the blades and components. For details, refer to the respective system documentation.

Page 75 of the Emerson ATCA-7150 user manual — 3.6.4 DIMM
Seite 75 · Zum Vergrößern klicken
Seite 75
Emerson ATCA-7150 — 3.6.4 DIMM diagram (page 75)
Abb. 112

z Preparing spare parts and tools

— Prepare the component to be installed or replaced. When you hold or transport the component, use the special antistatic package. Also, you need to tidy, record, and repair the component during routine maintenance.

— Prepare the cross screwdriver, screws, plastic supports, cooling gel, and ESD- preventive wrist strap. The supplier provides a list of tools and negotiates with to decide the tool provider.

z Confirming installation or changing position Confirm the positions of the cabinet, the shelf, and the slot where the ATCA-7150 is installed. Then, stick a label on the face plate of the ATCA-7150 to avoid wrong operation.

z Others If a serious problem occurs and cannot be solved when you install or replace the component, contact Emerson Network Power for technical support. For details on contact methods, see Contacting Emerson Network Power for Technical Support on page 100.

3.6.4 DIMM

When you install or replace the DIMM, pay attention to the following points:

z The ATCA-7150 provides four DIMM interfaces and supports the DIMM with a capacity of 512 MB, 1 GB, 2 GB or 4 GB.

z The DIMMs must have the same size, frequency, type, and technology, physical design and manufacturer.

z DIMMs must be of single or dual rank type. Quad rank types are not supported.

z If the DIMMs are not fully configured, you need to install the required DIMMs in the related interfaces.

— If one DIMM is configured, install it in DIMM slot 0.

— If two DIMMs are configured, install them in DIMM slots 0 and 1.

— Configuring three DIMMs is not supported.

Page 76 of the Emerson ATCA-7150 user manual — 3.6.4.1 Installing the DIMM
Seite 76 · Zum Vergrößern klicken
Seite 76
Emerson ATCA-7150 — Figure 3-3 Positions of the DIMM Interfaces diagram (page 76)
Abb. 113 · Figure 3-3 Positions of the DIMM Interfaces

Figure 3-3 shows the positions of the DIMM interfaces on the ATCA-7150.

Figure 3-3 Positions of the DIMM Interfaces

Emerson ATCA-7150 — Figure 3-3 Positions of the DIMM Interfaces diagram (page 76)
Abb. 114 · Figure 3-3 Positions of the DIMM Interfaces

Table 3-6 DIMM Configuration on the ATCA-7150

Emerson ATCA-7150 — Figure 3-3 Positions of the DIMM Interfaces diagram (page 76)
Abb. 115 · Figure 3-3 Positions of the DIMM Interfaces

3.6.4.1 Installing the DIMM

To install the DIMM, proceed as follows:

1. Wear the ESD-preventive wrist strap. For details, see Wearing the ESD-Preventive Wrist Strap on page 75 .
Page 77 of the Emerson ATCA-7150 user manual — Figure 3-3 Positions of the DIMM Interfaces
Seite 77 · Zum Vergrößern klicken
Seite 77
Emerson ATCA-7150 — Figure 3-3 Positions of the DIMM Interfaces diagram (page 77)
Abb. 116 · Figure 3-3 Positions of the DIMM Interfaces
2. Lay the ATCA-7150 where the DIMM is to be installed on the antistatic desktop.
3. Take the DIMM out of the antistatic package.
4. Make sure that two interface fixing clips are fully open. Adjust the DIMM to align it with the DIMM interface.
Emerson ATCA-7150 — Figure 3-3 Positions of the DIMM Interfaces diagram (page 77)
Abb. 117 · Figure 3-3 Positions of the DIMM Interfaces

Product Damage Operate the fixing clips slightly to avoid breaking them or damaging the DIMM interface.

5. Insert the DIMM in the interface along the guide rails, as shown in Figure 3-4 .

If there is a gap between the DIMM and the fixing clips, the DIMM is not installed properly. In this case, open the fixing clips and remove the DIMM. Then, insert the DIMM again.

6. Make sure that the fixing clips are fastened or closed firmly as shown in Figure 3-4 .
Page 78 of the Emerson ATCA-7150 user manual — 3.6.4.2 Replacing the DIMM
Seite 78 · Zum Vergrößern klicken
Seite 78
Emerson ATCA-7150 — Figure 3-4 Installing the DIMM diagram (page 78)
Abb. 118 · Figure 3-4 Installing the DIMM
7. Insert the ATCA-7150 with the DIMM installed in the shelf. For details, see Installing the ATCA-7150 in a Powered Shelf on page 91 .

Figure 3-4 Installing the DIMM

Emerson ATCA-7150 — Figure 3-4 Installing the DIMM diagram (page 78)
Abb. 119 · Figure 3-4 Installing the DIMM

You can install the DIMMs in other DIMM interfaces in the same way.

After installation, insert the ATCA-7150 in the shelf and power on the ATCA-7150. Check whether the OS can be loaded properly. If it can be, in the OS, check whether the displayed memory capacity is consistent with the actual one.

3.6.4.2 Replacing the DIMM

To replace the DIMM, proceed as follows:

1. Wear the ESD-preventive wrist strap. For details, see Wearing the ESD-Preventive Wrist Strap on page 75 .
2. Remove the ATCA-7150 whose DIMM is to be replaced.
Page 79 of the Emerson ATCA-7150 user manual — Figure 3-4 Installing the DIMM
Seite 79 · Zum Vergrößern klicken
Seite 79
Emerson ATCA-7150 — Figure 3-4 Installing the DIMM diagram (page 79)
Abb. 120 · Figure 3-4 Installing the DIMM

For details, see Removing the ATCA-7150 on page 95.

Emerson ATCA-7150 — Figure 3-4 Installing the DIMM diagram (page 79)
Abb. 121 · Figure 3-4 Installing the DIMM

z To avoid breaking them or damaging the DIMM interface, do not exert too much power to operate the fixing clips.

z If you open the two fixing clips of the DIMM at the same time, the DIMM bounces from the interface. Operate the fixing clips carefully to avoid damaging the DIMM.

3. Open one fixing clip of the DIMM carefully until the DIMM rises from the interface. Hold the top edge of the DIMM and open the other fixing clip carefully until the DIMM is removed from the interface, as shown in Figure 3-5 .
4. Take the DIMM out of the interface carefully, as shown in Figure 3-5 .
5. Place the faulty DIMM in the antistatic package.
6. Take the new DIMM out of the antistatic package.
7. Install the new DIMM. For details, see Installing the DIMM on page 82 .
Page 80 of the Emerson ATCA-7150 user manual — 3.6.5.1 Installing the Hard Disk
Seite 80 · Zum Vergrößern klicken
Seite 80
Emerson ATCA-7150 — Figure 3-5 Removing the DIMM diagram (page 80)
Abb. 122 · Figure 3-5 Removing the DIMM
8. Install the ATCA-7150 with the DIMM replaced. For details, see Installing the ATCA-7150 in a Powered Shelf on page 91 .

Figure 3-5 Removing the DIMM

Emerson ATCA-7150 — Figure 3-5 Removing the DIMM diagram (page 80)
Abb. 123 · Figure 3-5 Removing the DIMM

After replacement, check whether the OS can be loaded properly. If it can be, in the OS, check whether the displayed memory capacity is consistent with the actual one.

3.6.5 Hard Disk

This section describes how to install and replace the hard disk on the ATCA-7150.

3.6.5.1 Installing the Hard Disk

For more information on the installation of the hard disk, refer to the HDD Installation Sheet.

To install the hard disk, proceed as follows:

1. Wear the ESD-preventive wrist strap. For details, see Wearing the ESD-Preventive Wrist Strap on page 75 .
2. Take the hard disk to be installed out of the antistatic package.
Page 81 of the Emerson ATCA-7150 user manual — Figure 3-5 Removing the DIMM
Seite 81 · Zum Vergrößern klicken
Seite 81
Emerson ATCA-7150 — Figure 3-5 Removing the DIMM diagram (page 81)
Abb. 124 · Figure 3-5 Removing the DIMM
3. Exert even force to push the hard disk smoothly in the hard disk holder. Align the screw holes at the sides of the hard disk with those at the sides of the holder, as shown in Figure 3-6 .
4. Use the screwdriver to fasten the four screws clockwise to fix the hard disk, as shown in Figure 3-6 .
5. Exert even force to push the hard disk in the fixing bracket on the ATCA-7150, as shown in Figure 3-6 .
6. Insert the ATCA-7150 with the hard disk installed in the shelf. For details, see Installing the ATCA-7150 in a Powered Shelf on page 91 .

You can install the other hard disk in the same way.

Page 82 of the Emerson ATCA-7150 user manual — Figure 3-6 Installing the Hard Disk
Seite 82 · Zum Vergrößern klicken
Seite 82
Emerson ATCA-7150 — Figure 3-6 Installing the Hard Disk diagram (page 82)
Abb. 125 · Figure 3-6 Installing the Hard Disk

After installation, check whether the ATCA-7150 can be powered on and work normally and whether the data in the hard disk can be read and written normally.

Figure 3-6 Installing the Hard Disk

Emerson ATCA-7150 — Figure 3-6 Installing the Hard Disk diagram (page 82)
Abb. 126 · Figure 3-6 Installing the Hard Disk
Page 83 of the Emerson ATCA-7150 user manual — 3.6.5.2 Replacing the Hard Disk
Seite 83 · Zum Vergrößern klicken
Seite 83
Emerson ATCA-7150 — 3.6.5.2 Replacing the Hard Disk diagram (page 83)
Abb. 127 · 3.6.5.2 Replacing the Hard Disk

3.6.5.2 Replacing the Hard Disk

To replace the hard disk, proceed as follows:

1. Wear the ESD-preventive wrist strap. For details, see Wearing the ESD-Preventive Wrist Strap on page 75 .
2. Remove the ATCA-7150 whose hard disk is to be replaced. For details, see Removing the ATCA-7150 on page 95 .
3. Remove the finger on the hard disk holder in a direction as shown in Figure 3-7 to unlock the hard disk.
4. Exert even force to pull the hard disk holder from the fixing bracket, as shown in Figure 3-7 .
5. Unfasten the four screws used to fasten the hard disk anticlockwise, as shown in Figure 3-7 .
6. Exert even force to pull the hard disk from the holder, as shown in Figure 3-7 .
7. Place the faulty hard disk in the antistatic package.
8. Take the new hard disk out of the antistatic package.
9. Install the new hard disk. For details, see Installing the Hard Disk on page 86 .
10. Install the ATCA-7150 with the hard disk replaced. For details, see Installing the ATCA-7150 in a Powered Shelf on page 91 .
Page 84 of the Emerson ATCA-7150 user manual — Figure 3-7 Removing the Hard Disk
Seite 84 · Zum Vergrößern klicken
Seite 84
Emerson ATCA-7150 — Figure 3-7 Removing the Hard Disk diagram (page 84)
Abb. 128 · Figure 3-7 Removing the Hard Disk

After replacement, check whether the ATCA-7150 can be powered on and work normally and whether the data in the hard disk can be read and written normally.

Figure 3-7 Removing the Hard Disk

Emerson ATCA-7150 — Figure 3-7 Removing the Hard Disk diagram (page 84)
Abb. 129 · Figure 3-7 Removing the Hard Disk
Page 85 of the Emerson ATCA-7150 user manual — 3.7.1.1 Installing the ATCA-7150 in a Powered Shelf
Seite 85 · Zum Vergrößern klicken
Seite 85
Emerson ATCA-7150 — 3.7 Installing and Removing the Blade diagram (page 85)
Abb. 130 · 3.7 Installing and Removing the Blade

3.7 Installing and Removing the Blade

3.7.1 Installation

RTM-ATCA-7150 must be installed before the ATCA-7150 to avoid product damage. For information on how to install the RTM-ATCA-7150, refer to Chapter 2, Installation of the RTM- ATCA-7150, on page 35

3.7.1.1 Installing the ATCA-7150 in a Powered Shelf

The following procedure describes the installation of the blade. It assumes that your system is powered and if applicable the RTM is installed. If your system is unpowered, you can disregard the blue LED and thus skip the respective step. In this case it is a purely mechanical installation.

1. Wear the ESD-preventive wrist strap. For details, see Wearing the ESD-Preventive Wrist Strap on page 75
2. Take the ATCA-7150 out of the antistatic package.
3. Fully open the upper and lower ejector handles.
4. Slide the ATCA-7150 along the guide rails until the positioning pins of the ATCA-7150 are inserted in the positioning holes in the shelf, as shown in Figure 3-8 .
5. Make sure that the upper and lower ejector handles are attached to the beam properly. Close the upper and lower ejector handles until the inner sides of the ejector handles are attached to the face plate, as shown in Figure 3-8 . After closing the handles, the blue LED, OOS and HEALTHY LEDs blink. When payload is powered on, the blue LED is continously illuminated, and the OOS and HEALTHY LEDs are out.
Page 86 of the Emerson ATCA-7150 user manual — 3.7.1.2 Checking the Installation
Seite 86 · Zum Vergrößern klicken
Seite 86
Emerson ATCA-7150 — Figure 3-8 Installing the ATCA-7150 diagram (page 86)
Abb. 131 · Figure 3-8 Installing the ATCA-7150
6. User the screwdriver to clockwise fasten the screws to fix the ATCA-7150, as shown in Figure 3-8 .
7. Fully open the ejector handles and the ATCA-7150 is ready for power-on. Before you power on the ATCA-7150, connect the required external cables and check that the ATCA-7150 is installed properly.

Figure 3-8 Installing the ATCA-7150

Emerson ATCA-7150 — Figure 3-8 Installing the ATCA-7150 diagram (page 86)
Abb. 132 · Figure 3-8 Installing the ATCA-7150

3.7.1.2 Checking the Installation

After you install the RTM of the server blade and the ATCA-7150, and connect and bind cables, check whether:

z The ATCA-7150 and RTM are installed in the paired slots.

z The upper and lower ejector handles of the RTM are fully closed.

Page 87 of the Emerson ATCA-7150 user manual — 3.7.1.3.2 Procedure
Seite 87 · Zum Vergrößern klicken
Seite 87
Emerson ATCA-7150 — 3.7.1.3 Power-On diagram (page 87)
Abb. 133 · 3.7.1.3 Power-On

z The cables are properly connected.

z The cables are well bound.

3.7.1.3 Power-On

Emerson ATCA-7150 — 3.7.1.3 Power-On diagram (page 87)
Abb. 134 · 3.7.1.3 Power-On

The RTM of the server blade is powered by the ATCA-7150 in the slot paired with the RTM slot. The RTM of the server blade does not support hot swap. Therefore, the RTM must be installed in the slot before the ATCA-7150 is installed in the paired slot.

3.7.1.3.1 Checks Before Power-On

Before power-on, you need to confirm that:

z The RTM of the server blade and SMM are installed properly.

z The shelf and SMM are powered on properly.

z The required external cables are connected.

z The upper and lower ejector handles of the ATCA-7150 are opened.

3.7.1.3.2 Procedure

To power on the ATCA-7150, proceed as follows:

1. Wear the ESD-preventive wrist strap. For details, see Wearing the ESD-Preventive Wrist Strap on page 75 .
Page 88 of the Emerson ATCA-7150 user manual — 3.7.2.1 Power Off
Seite 88 · Zum Vergrößern klicken
Seite 88
Emerson ATCA-7150 — 3.7.2 Removal diagram (page 88)
Abb. 135 · 3.7.2 Removal
2. Close the upper and lower ejector handles. The HOTSWAP LED blinks at the short blink rate. The OOS and HEALTHY LEDs blink for 10 times at the same time. When the OOS and HOTSWAP LEDs are off and the HEALTHY LED is on (green), the ATCA-7150 is powered on properly.

During power-on, if the HEALTHY LED blinks (red), an alarm occurs to the ATCA-7150.

3.7.2 Removal

Emerson ATCA-7150 — 3.7.2 Removal diagram (page 88)
Abb. 136 · 3.7.2 Removal

z Before you remove an ATCA-7150 or RTM of the server blade, prepare packing materials, such as an antistatic package.

z Before you remove an ATCA-7150 or RTM of the server blade, power off the ATCA-7150. For details on how to power off the ATCA-7150, see Power Off on page 94.

3.7.2.1 Power Off

Emerson ATCA-7150 — 3.7.2.1 Power Off diagram (page 88)
Abb. 137 · 3.7.2.1 Power Off

The RTM of the server blade is powered by the ATCA-7150 in the slot paired with the RTM slot. The RTM of the server blade does not support hot swap. You can remove the RTM only when the ATCA-7150 is powered off and removed from the slot.

Page 89 of the Emerson ATCA-7150 user manual — 3.7.2.2 Removing the ATCA-7150
Seite 89 · Zum Vergrößern klicken
Seite 89
Emerson ATCA-7150 — 3.7.2.2 Removing the ATCA-7150 diagram (page 89)
Abb. 138 · 3.7.2.2 Removing the ATCA-7150

3.7.2.1.1 Checks Before Power-Off

Before power-off, you need to confirm that:

z Data has been saved on the ATCA-7150.

z No application runs on the ATCA-7150.

z The ATCA-7150 has quitted the operating system (OS).

3.7.2.1.2 Procedure

To power off the ATCA-7150, proceed as follows:

1. Wear the ESD-preventive wrist strap. For details, see Wearing the ESD-Preventive Wrist Strap on page 75 .
2. Open the upper and lower ejector handles. The ATCA-7150 is powered off properly when:

z The HOTSWAP LED blinks at the short blink rate and then is on (blue).

z The OOS LED is on (red or amber).

z The HEALTHY LED is off.

3.7.2.2 Removing the ATCA-7150

To remove the ATCA-7150, proceed as follows:

1. Wear the ESD-preventive wrist strap. For details, see Wearing the ESD-Preventive Wrist Strap on page 75 .
2. Open the upper and lower ejector handles to power off the ATCA-7150, as shown in Figure 3-9 . For details, see Power Off on page 94 .
3. Use the screwdriver to unfasten the captive screws anticlockwise, as shown in Figure 3-9 .
Page 90 of the Emerson ATCA-7150 user manual — 3.8 Ejector Handles
Seite 90 · Zum Vergrößern klicken
Seite 90
Emerson ATCA-7150 — Figure 3-9 Removing the ATCA-7150 diagram (page 90)
Abb. 139 · Figure 3-9 Removing the ATCA-7150
4. Remove the ATCA-7150 along the guide rails, as shown in Figure 3-9 .
5. Place the ATCA-7150 in the antistatic package.

Figure 3-9 Removing the ATCA-7150

Emerson ATCA-7150 — Figure 3-9 Removing the ATCA-7150 diagram (page 90)
Abb. 140 · Figure 3-9 Removing the ATCA-7150

3.8 Ejector Handles

The ATCA-7150 supports hot swap. As shown in Figure 3-3, the face plate of the ATCA-7150 provides an upper and a lower ejector handles. The ejector handles help to insert, remove, power on, and power off the ATCA-7150.

Insertion and Removal

Page 91 of the Emerson ATCA-7150 user manual — Table 3-7 Insertion and Removal of the ATCA-7150
Seite 91 · Zum Vergrößern klicken
Seite 91
Emerson ATCA-7150 — Table 3-7 Insertion and Removal of the ATCA-7150 diagram (page 91)
Abb. 141 · Table 3-7 Insertion and Removal of the ATCA-7150

Table 3-7 describes the insertion and removal of the ATCA-7150 by using the ejector handles.

Table 3-7 Insertion and Removal of the ATCA-7150

Insert the ATCA-7150 The process for inserting the ATCA-7150 is as follows:

z When the ejector handles are not closed, the HOTSWAP LED is on and the ATCA-7150 is not powered on.

z After the ejector handles are closed, the HOTSWAP LED blinks at the long blink rate and the ATCA-7150 requests for activation.

z After activation, the ATCA-7150 is powered on and the HOTSWAP LED is off.

Remove the ATCA-7150 The process for removing the ATCA-7150 is as follows:

z When you open the ejector handles, the HOTSWAP LED blinks at the short blink rate and the ATCA-7150 requests for deactivation.

z After deactivation, the ATCA-7150 is ready for power-off.

z When the HOTSWAP LED is on, the ATCA-7150 is powered off. At this time, you can remove the ATCA-7150 by holding the ejector handles.

Table 3-8 describes the power-on and power-off of the ATCA-7150 by using the ejector handles.

Table 3-8 Power-On and Power-Off of the ATCA-7150

Emerson ATCA-7150 — Table 3-7 Insertion and Removal of the ATCA-7150 diagram (page 91)
Abb. 142 · Table 3-7 Insertion and Removal of the ATCA-7150

Power on theATCA-7150 Whether you close one ejector handle or both ejector handles, the ATCA- 7150 can be powered on and work well.

Power off the ATCA-7150 When both ejector handles are opened, you can power off the ATCA- 7150.

Operation Description · Power-On and Power-Off

Page 92 of the Emerson ATCA-7150 user manual — Table 3-7 Insertion and Removal of the ATCA-7150
Seite 92 · Zum Vergrößern klicken
Seite 92
Emerson ATCA-7150 — Table 3-7 Insertion and Removal of the ATCA-7150 diagram (page 92)
Abb. 143 · Table 3-7 Insertion and Removal of the ATCA-7150
Page 93 of the Emerson ATCA-7150 user manual — A.3 Principles
Seite 93 · Zum Vergrößern klicken
Seite 93
Emerson ATCA-7150 — A Troubleshooting diagram (page 93)
Abb. 144 · A Troubleshooting

A.1 Overview

This chapter describes:

z LED Display Exceptions

z Power-On Startup Exceptions

A.2 Precautions

Emerson ATCA-7150 — A.2 Precautions diagram (page 93)
Abb. 145 · A.2 Precautions

Before you remove the faults of the ATCA-7150 and RTM-ATCA-7150 suite, be familiar with the Server System Safety Information shipped with the shelf.

A.3 Principles

During troubleshooting, follow the principles:

z Diagnose the outside and then the inside. In troubleshooting, remove the outside faults, such as power interruption and the faults of the peer device.

z Diagnose the network and then the NEs (network Elements). According to the network topology, analyze whether the network environment is normal and the interconnected device is faulty. Locate the NE to which the fault occurs.

z Diagnose the high speed part and then the low speed part. From the alarm signal stream, the alarm of the high speed signal often causes the alarm of the low speed signal. Therefore, remove the fault of the high speed part first.

Show 4 more labels / short text on this page
z Precautions · z Principles · z Resources · z OS Exceptions
Page 94 of the Emerson ATCA-7150 user manual — A.5 Contacting Emerson Network Power for Technical Support
Seite 94 · Zum Vergrößern klicken
Seite 94
Emerson ATCA-7150 — A.4 Resources diagram (page 94)
Abb. 146 · A.4 Resources

z Analyze the alarm of high level and then that of low level. Analyze the alarm of high level, such as critical alarm or major alarm. Then, analyze the alarm of low level, such as minor alarm or warning alarm.

A.4 Resources

You can use the following resources for troubleshooting:

z LEDs The ATCA-7150 suite provides the following LEDs:

— Out of Service (OOS) LED

— In Service (IS) LED

— Attention (ATN) LED

— Hotswap (H/S) LED

— Hard Disk (HDD) LED In addition, the external GE daughter card provides network port LEDs (for two Ethernet interfaces). The external FC daughter card provides FC status LEDs (for two FC interfaces). You can monitor the LEDs to diagnose the current status of the ATCA-7150 suite. For details on the LEDs of the ATCA-7150 suite, see the LED section in the ATCA-7150 Installation and Use manual.

z Generating error codes and alarm signals Error codes and alarm signals help you to further locate and remove the faults.

A.5 Contacting Emerson Network Power for Technical Support

If a problem persists after you handle it under the guidance of this document, contact the local office or Customer Service Center of Emerson Network Power to obtain timely technical support. Before you report the problem to Emerson Network Power engineer, collect the following information:

z Detailed name and address of the customer

z Contact person and telephone number

z Time when the fault occurred

Page 95 of the Emerson ATCA-7150 user manual — A.6.2 In Service (IS) LED Blinks
Seite 95 · Zum Vergrößern klicken
Seite 95
Emerson ATCA-7150 — A.6 LED Display Exceptions diagram (page 95)
Abb. 147 · A.6 LED Display Exceptions

z Detailed description on the fault

z Device type and software version

z Measures taken after the fault occurred and related results

z Problem level and required solution time

The contact address of Emerson Network Power is:

Emerson Network Power - Embedded Computing GmbH

Lilienthalstr. 15

A.6 LED Display Exceptions

A.6.1 LEDs Are Off

All LEDs on the ATCA-7150 face plate are off, including the OOS, IS, ATN, H/S, and HDD LEDs. At the same time, no information is displayed on the KVM.

To solve the problem, proceed as follows:

1. Check that the ATCA-7150 is properly inserted in the shelf.
2. Check whether the -48 V DC inputs to the shelf are normal.
3. If the PEM of the ATCA-7150 is damaged, replace the ATCA-7150.
4. Contact Emerson Network Power technical support engineer to load the BMC software again.

A.6.2 In Service (IS) LED Blinks

Show 4 more labels / short text on this page
85579 Neubiberg-Munich/Germany · Description · Solution · Description
Page 96 of the Emerson ATCA-7150 user manual — A.7 Power-On Startup Exceptions
Seite 96 · Zum Vergrößern klicken
Seite 96
Emerson ATCA-7150 — A.7 Power-On Startup Exceptions diagram (page 96)
Abb. 148 · A.7 Power-On Startup Exceptions

The IS LED of the ATCA-7150 blinks (red). The alarm severity varies with the blinking frequency. The higher the blinking frequency, the more serious the alarm.

The IS LED can be green or red. The working state of the ATCA-7150 decides the color of the LED.

The blinking frequency of the IS LED indicates the alarm level:

z For a minor alarm, the IS LED blinks at a frequency of 0.5 Hz.

z For a major alarm, the IS LED blinks at a frequency of 1 Hz.

z For a critical alarm, the IS LED blinks at a frequency of 4 Hz.

By using the SMM command, query the status and logs of the blade where the alarm occurs.

If an alarm occurs due to over high temperature, confirm that:

1. The temperature in the equipment room meets the operating requirements for the product.
2. The air intake vents and exhaust vents of the shelf are not blocked.
3. Blank filler blades are installed in the vacant slots of the shelf.
4. The fans are adjusted to the required speed.

A.7 Power-On Startup Exceptions

After you close the upper and lower ejector handles of the ATCA-7150, the HOTSWAP LED blinks (blue) and no information is displayed on the KVM.

To solve the problem, proceed as follows:

1. Check that the ATCA-7150 is properly inserted in the shelf and that its ejector handles are fully closed.
2. Check that the pointers of the ATCA-7150 rear part that is connected to the backplane are not damaged or deformed.

Solution · Description · Solution

Page 97 of the Emerson ATCA-7150 user manual — A.8.2 Number of DIMMs Is Inconsistent
Seite 97 · Zum Vergrößern klicken
Seite 97
Emerson ATCA-7150 — A.8 Component Exceptions diagram (page 97)
Abb. 149 · A.8 Component Exceptions
3. Check the power supply of the shelf. If the power is low, the ATCA-7150 cannot be powered on through the SMM.
4. Check whether the SMM is firmly inserted in the proper position and works well. Make sure that at least one SMM is present in the shelf and works well.
5. Contact Emerson Network Power technical support engineer to check the IPMC software.

A.8 Component Exceptions

A.8.1 Component Is Unavailable

The optional component that is newly installed cannot be used.

To solve the problem, proceed as follows:

1. Make sure that this optional component is suitable for the ATCA-7150 suite. For details, see Optional Components Supported by the ATCA-7150 on page 79 .
2. Make sure that the optional component is installed properly.
3. Make sure that any installed device or cable is not loose.
4. Re-install the optional component that is installed just now.
5. Replace the optional component that is installed just now. For details, see Installing Blade Accessories on page 78 .

A.8.2 Number of DIMMs Is Inconsistent

The number of the displayed system DIMMs is less than that of the installed physical DIMMs.

Show 4 more labels / short text on this page
Description · Solution · Description · Solution
Page 98 of the Emerson ATCA-7150 user manual — A.9.1 ATCA-7150 Cannot Be Started
Seite 98 · Zum Vergrößern klicken
Seite 98
Emerson ATCA-7150 — A.9 Power Exceptions diagram (page 98)
Abb. 150 · A.9 Power Exceptions

To solve the problem, proceed as follows:

1. Make sure that all DIMMs of correct type are installed in the slots properly.
2. Check for consistency of the size and frequency of the installed DIMMs.
3. Re-install the DIMMs. For details, see Installing the DIMM on page 82 .
4. Replace the DIMM. For details, see Replacing the DIMM on page 84 .
5. If the problem persists, replace the ATCA-7150. For details, see Installing and Removing the Blade on page 91 .

A.9 Power Exceptions

A.9.1 ATCA-7150 Cannot Be Started

The ATCA-7150 cannot be started.

To solve the problem, proceed as follows:

1. Make sure that the shelf is powered on properly. For details, refer to the respective system documentation.
2. If you install an optional component on the ATCA-7150, remove the optional component and then restart the ATCA-7150.
3. Start another ATCA-7150 in the shelf. If it can be started normally, replace the faulty ATCA7150.
4. If the problem persists, see Uncertain Exceptions on page 109 .

Description · Solution

Page 99 of the Emerson ATCA-7150 user manual — A.10.1 Keyboard Cannot Be Used
Seite 99 · Zum Vergrößern klicken
Seite 99
Emerson ATCA-7150 — A.9.2 ATCA-7150 Automatically Shuts Down diagram (page 99)
Abb. 151 · A.9.2 ATCA-7150 Automatically Shuts Down

A.9.2 ATCA-7150 Automatically Shuts Down

The ATCA-7150 automatically shuts down without any explicit reason.

To solve the problem, proceed as follows:

1. Make sure that each component of the shelf is installed properly. For details, refer to the respective system documentation. If some components are not installed or are installed improperly, the ATCA-7150 may automatically shut down.
2. Replace the ATCA-7150.

A.10 Peripheral Exceptions

A.10.1 Keyboard Cannot Be Used

All keys or part keys on the keyboard cannot be used.

To solve the problem, proceed as follows:

1. Make sure that the cable of the keyboard is connected properly and firmly and that the cable of the keyboard and that of the mouse are not connected reversely.
2. Make sure that the ATCA-7150 is powered on. For details, see Power-On on page 93 .
3. Replace the keyboard. For details, refer to the document shipped with the keyboard that you use.
4. Replace the RTM of the server blade that works with the ATCA-7150.
Show 4 more labels / short text on this page
Description · Solution · Description · Solution
Page 100 of the Emerson ATCA-7150 user manual — A.10.3 Monitor Remains Dark
Seite 100 · Zum Vergrößern klicken
Seite 100
Emerson ATCA-7150 — A.10.2 Mouse Cannot Be Used diagram (page 100)
Abb. 152 · A.10.2 Mouse Cannot Be Used

A.10.2 Mouse Cannot Be Used

The mouse cannot be used.

To solve the problem, proceed as follows:

1. Make sure that the cable of the mouse is connected properly and firmly and that the cable of the mouse and that of the keyboard are not connected reversely.
2. Make sure that the mouse works well on other ATCA-7150s.
3. Make sure that the mouse has been properly installed with drivers.
4. Make sure that the ATCA-7150 is powered on and started normally.
5. Replace the mouse. For details, refer to the document shipped with the mouse that you use.

A.10.3 Monitor Remains Dark

When you connect the monitor to the running ATCA-7150 or start some applications of the ATCA-7150, the monitor remains dark.

To solve the problem, proceed as follows:

1. Make sure that the power cable of the monitor is connected properly.
2. Make sure that the monitor is connected to the RTM of the server blade properly and firmly.
3. Make sure that you have turned on the monitor and properly adjusted the luminance and contrast control.
4. Power off the ATCA-7150 and then power it on again.
Show 4 more labels / short text on this page
Description · Solution · Description · Solution
Page 101 of the Emerson ATCA-7150 user manual — A.10.5 No Information Is Displayed on the Monitor
Seite 101 · Zum Vergrößern klicken
Seite 101
Emerson ATCA-7150 — A.10.4 Monitor Display Is Abnormal diagram (page 101)
Abb. 153 · A.10.4 Monitor Display Is Abnormal
5. Replace the monitor or ATCA-7150. For details on how to replace the monitor, refer to the document shipped with the monitor that you use. For details on how to replace the ATCA-7150, see Installing and Removing the Blade on page 91 .

A.10.4 Monitor Display Is Abnormal

Jittering, unreadable, rolling or twisted image is displayed on the monitor screen.

To solve the problem, proceed as follows:

1. If monitor self-test indicates that the monitor works normally, consider the position of the monitor. The magnetic field around other devices (such as transformers, electronic devices, fluorescent lights, and other monitors) may cause screen jitters, image fluctuation, or unreadable, rolling or twisted image.
2. Close the monitor if this condition happened. When you move a color monitor, the color of the screen may be distorted. Move the device and monitor. Make sure that the distance between them is at least 305 mm.
3. Turn on the monitor. If the problem persists, replace the monitor or ATCA-7150. For details on how to replace the monitor, refer to the document shipped with the monitor that you use. For details on how to replace the ATCA-7150, see Installing and Removing the Blade on page 91 .

A.10.5 No Information Is Displayed on the Monitor

The ATCA-7150 LED is normal and no alarm is generated. However, no information is displayed on the monitor.

Show 4 more labels / short text on this page
Description · Solution · Description · Solution
Page 102 of the Emerson ATCA-7150 user manual — A.11.2 Network Connection Is Faulty
Seite 102 · Zum Vergrößern klicken
Seite 102
Emerson ATCA-7150 — A.11 Other Exceptions diagram (page 102)
Abb. 154 · A.11 Other Exceptions

To solve the problem, proceed as follows:

1. Make sure that:

z The RTM of the server blade is inserted properly.

z The upper and lower ejector handles are fully closed.

z The LEDs are in normal state.

2. Make sure that the cable connectors of the monitor contact well.
3. Check whether the DIMM is inserted.
4. If the DIMM is inserted, check whether it is inserted in the memory slot firmly.
5. If the problem persists, replace the DIMM with a new one. For details, see Replacing the DIMM on page 84 .

A.11 Other Exceptions

A.11.1 USB Interface Cannot Be Used

The USB interface cannot be used.

To solve the problem, proceed as follows:

1. Make sure that the USB device drivers are installed properly.
2. Make sure that the OS that you use supports the USB device.

A.11.2 Network Connection Is Faulty

One or more ATCA-7150 cannot communicate with the external network.

Show 4 more labels / short text on this page
Description · Solution · Description · Solution
Page 103 of the Emerson ATCA-7150 user manual — A.12 Uncertain Exceptions
Seite 103 · Zum Vergrößern klicken
Seite 103
Emerson ATCA-7150 — A.11.3 A Fault Occurs in Software diagram (page 103)
Abb. 155 · A.11.3 A Fault Occurs in Software

To solve the problem, proceed as follows:

1. Make sure that the network module that you use is installed in the server system and works normally. For details, refer to the respective system documenation.
2. The setting in the network module is suitable for the ATCA-7150. For details, refer to the respective system documentation.
3. If the problem persists, see Uncertain Exceptions on page 109 .

A.11.3 A Fault Occurs in Software

A fault may occur in software.

To solve the problem, proceed as follows:

1. Check whether the problem is caused by software fault.
2. Check whether the ATCA-7150 has the minimum memory required by the software.
3. Check whether the design of the software is applied to the server.
4. Check whether other software can run on the ATCA-7150.
5. Check whether this software can run on other ATCA-7150s.
6. If an error message is generated when you use the software, refer to the document shipped with the software to get the details on the message and solution.
7. Contact Emerson Network Power technical support engineer to handle the problem.

A.12 Uncertain Exceptions

When you diagnose the faulty ATCA-7150, check whether the ATCA-7150 or the shelf has a fault.

z If all ATCA-7150s have the same symptom, it is very likely that a fault occurs in the shelf. For details, refer to the respective system documentation.

z If the shelf has multiple ATCA-7150s and one ATCA-7150 is faulty, troubleshoot the faulty ATCA-7150.

Description · Solution

Page 104 of the Emerson ATCA-7150 user manual — A.11.3 A Fault Occurs in Software
Seite 104 · Zum Vergrößern klicken
Seite 104
Emerson ATCA-7150 — A.11.3 A Fault Occurs in Software diagram (page 104)
Abb. 156 · A.11.3 A Fault Occurs in Software

If you think that the fault is caused by software, see A Fault Occurs in Software on page 109.

Damaged CMOS data or BIOS codes may cause some uncertain problems. To reset the CMOS data, contact Emerson Network Power for technical support. For detailed contact methods, see Contacting Emerson Network Power for Technical Support on page 100.

Check whether the PEM of the shelf works well. If the PEM works well but the problem persists after you install the ATCA-7150 again, proceed as follows:

1. Make sure that the ATCA-7150 is inserted in the proper slot of the shelf. The ATCA-7150 is installed in one of the slots 1-6 or 9-14 at the front side of the shelf.
2. Make sure that the external cables that the ATCA-7150 and its RTM use are properly connected.
3. Power off the ATCA-7150 and remove it from the shelf.
4. Remove or disconnect the following devices (one at a time) until you find the fault. Reinstall and power on the ATCA-7150.

a. SOL daughter card

b. Hard disk drive

c. DIMM The hardware configurations enough to start the ATCA-7150 include:

z One 512 MB DIMM

When the ATCA-7150 is configured with only one DIMM, the DIMM can be installed in DIMM interface 0 only. For the postion of the DIMM interface, see Figure 3-3.

z One hard disk

z Main board · z One CPU · z Available shelf

Page 105 of the Emerson ATCA-7150 user manual — A.13 POST Code Checkpoints
Seite 105 · Zum Vergrößern klicken
Seite 105
Emerson ATCA-7150 — A.13 POST Code Checkpoints diagram (page 105)
Abb. 157 · A.13 POST Code Checkpoints
5. Install and power on the ATCA-7150. If the problem persists, replace the following components in order:

a. Hard disk

b. DIMM

c. CPU

d. Main board

6. If the ATCA-7150 passes all system tests, a fault may occurs in the external network connection.

A.13 POST Code Checkpoints

POST code checkpoints are the largest set of checkpoints during the BIOS pre-boot process.

Table A-1 lists the types of checkpoints that may occur during the POST stage of the BIOS and related solutions.

To clear the CMOS RAM or upgrade the BIOS, contact Emerson Network Power for technical support.

Table A-1 POST code checkpoints

Emerson ATCA-7150 — A.13 POST Code Checkpoints diagram (page 105)
Abb. 158 · A.13 POST Code Checkpoints

03 Disable NMI, parity, video for EGA, and DMA controllers.

z BIOS modules on POST entry and GPNV area

Page 106 of the Emerson ATCA-7150 user manual — A.13 POST Code Checkpoints
Seite 106 · Zum Vergrößern klicken
Seite 106
Emerson ATCA-7150 — A.13 POST Code Checkpoints diagram (page 106)
Abb. 159 · A.13 POST Code Checkpoints

Table A-1 POST code checkpoints (continued)

04 Check the CMOS diagnostic byte to determine whether battery power is proper and whether the CMOS checksum is proper. Verify the CMOS checksum by reading the storage area. If the CMOS checksum is wrong, update CMOS with power-on default values and clear passwords. Initialize data variables that are based on CMOS setup questions.

1. Restart the ATCA-7150.
2. Clear CMOS and then restart the ATCA-7150.
3. Replace the ATCA-7150.

05 Initialize the interrupt controlling hardware and interrupt vector table.

1. Restart the ATCA-7150.
2. Replace the ATCA-7150.

06 Initialize the system timer. Initialize the handler for system timer interrupt.

08 Initialize the keyboard controller (KBC). 1. Restart the ATCA-7150

2. Replace the ATCA-7150. C0 Early CPU initialization starts.

C1 Set the boot processor initialization information.

C2 Set the boot processor initialization for POST.

C5 List and set application processors.

C6 Re-enable cache for the boot processor.

C7 Exit the early CPU initialization.

0A Initialize the 8042 compatible KBC. 1. Restart the ATCA-7150.

2. Replace the ATCA-7150.

0B Detect the presence of PS/2 mouse. 1. Restart the ATCA-7150

0C Detect the presence of the keyboard in KBC port.

2. Replace the PS/2 mouse and restart the ATCA-7150.
3. Replace the ATCA-7150.

0E Test and initialize different input devices. Also, update kernel variables. Disable handler for IRQ1 installation. Uncompress all available languages, BIOS logo, and silent logo modules.

1. Restart the ATCA-7150.
2. Upgrade the BIOS and restart the ATCA-7150.
3. Replace the ATCA-7150.

Checkpoint Description Solution

Page 107 of the Emerson ATCA-7150 user manual — A.13 POST Code Checkpoints
Seite 107 · Zum Vergrößern klicken
Seite 107
Emerson ATCA-7150 — A.13 POST Code Checkpoints diagram (page 107)
Abb. 160 · A.13 POST Code Checkpoints

Table A-1 POST code checkpoints (continued)

13 Initialize early POST chipset registers. 1. Restart the ATCA-7150.

2. Replace the ATCA-7150.

24 Uncompress and initialize the specific BIOS modules of any platform.

1. Restart the ATCA-7150.
2. Upgrade the BIOS and restart the ATCA-7150.
3. Replace the ATCA-7150.

30 Initialize system management interrupt. 1. Restart the ATCA-7150.

2. Replace the ATCA-7150. 2C Initialize different devices. Detect and initialize the video adapter that is installed in the system and has optional ROMs.

2E Initialize all output devices.

31 Allocate memory for the ADM module and uncompress it. Control the ADM module for initialization. Initialize the language and font modules for ADM. Activate the ADM module.

1. Restart the ATCA-7150.
2. Upgrade the BIOS and restart the ATCA-7150.
3. Replace the ATCA-7150.

33 Initialize the silent boot module. Set the window for displaying text information.

1. Restart the ATCA-7150.
2. Replace the ATCA-7150.

37 Display the sign-on message, CPU information, setup key message, and any OEM specific information.

39 Initializes DMA controller 1 and DMA controller 2.

3A Initialize RTC date and time. 1. Restart the ATCA-7150.

2. Clear CMOS RAM and then restart the ATCA-7150.
3. Replace the ATCA-7150.

Checkpoint Description Solution

Page 108 of the Emerson ATCA-7150 user manual — A.13 POST Code Checkpoints
Seite 108 · Zum Vergrößern klicken
Seite 108
Emerson ATCA-7150 — A.13 POST Code Checkpoints diagram (page 108)
Abb. 161 · A.13 POST Code Checkpoints

Table A-1 POST code checkpoints (continued)

3B Test for total memory installed in the system. Also, Check for the Delete or ESC key to limit memory test. Display total memory in the system.

1. Restart the ATCA-7150.
2. Replace the ATCA-7150.

3C Initialize Mid POST chipset registers.

40 Detect different devices (such as parallel ports, serial ports, and coprocessor in CPU) successfully installed in the system and update the BDA, EBDA, and so on.

50 Program the memory hole or any kind of implementation that needs an adjustment in system RAM size if needed.

52 Update CMOS RAM memory size from the memory found in memory test. Allocate memory for the extended BIOS data area from base memory.

60 Initialize NumLock status and program the keyboard typematic rate.

75 Initialize Int-13 and prepare for IPL detection.

78 Initialize IPL devices controlled by BIOS and optional ROMs.

7A Initialize remaining optional ROMs. 1. Restart the ATCA-7150.

2. Upgrade the BIOS and restart the ATCA-7150.
3. Replace the ATCA-7150.

7C Generate and write contents of ESCD in NVRam.

1. Restart the ATCA-7150.
2. Check whether the BIOS write protection is enabled. If it is enabled, disable it and restart the ATCA-7150.
3. Replace the ATCA-7150.

84 Record errors encountered during POST. 1. Restart the ATCA-7150.

2. Replace the ATCA-7150.

Checkpoint Description Solution

Page 109 of the Emerson ATCA-7150 user manual — A.14 DIM Code Checkpoints
Seite 109 · Zum Vergrößern klicken
Seite 109
Emerson ATCA-7150 — A.14 DIM Code Checkpoints diagram (page 109)
Abb. 162 · A.14 DIM Code Checkpoints

Table A-1 POST code checkpoints (continued)

85 Display errors to the user and get the user response for errors.

Handle the fault according to the prompts displayed on the terminal.

8C Initialize late POST chipset registers. 1. Restart the ATCA-7150.

2. Replace the ATCA-7150. 8D Build ACPI tables (if ACPI is supported).

8E Program peripheral parameters. Enable or disable NMI as selected.

90 Initialize late POST of system management terminal.

A1 Perform clean-up work needed before booting to the OS.

1. Restart the ATCA-7150.
2. Replace the ATCA-7150.

A2 Take care of runtime image preparation for different BIOS modules. Initialize the IRQ routing table. Prepare the runtime language module. Disable the system configuration display if needed.

A4 Prepare the runtime language module.

A7 Display the system configuration screen if enabled. Initialize the CPU's system configuration screen before booting, which includes the programming of the MTRR's.

A8 Prepare CPU for OS booting, including final MTRR values.

1. Restart the ATCA-7150.
2. Replace the CPU.
3. Replace the ATCA-7150.

AC End POST initialization of chipset registers.

1. Restart the ATCA-7150.
2. Replace the ATCA-7150.

A.14 DIM Code Checkpoints

The device initialization manager (DIM) gets control at various time during BIOS POST to initialize different system buses.

Checkpoint Description Solution

Page 110 of the Emerson ATCA-7150 user manual — A.14 DIM Code Checkpoints
Seite 110 · Zum Vergrößern klicken
Seite 110
Emerson ATCA-7150 — A.14 DIM Code Checkpoints diagram (page 110)
Abb. 163 · A.14 DIM Code Checkpoints

Table A-2 lists the checkpoints where the DIM module is accessed and solutions.

Page 111 of the Emerson ATCA-7150 user manual — Table A-2 DIM code checkpoints
Seite 111 · Zum Vergrößern klicken
Seite 111
Emerson ATCA-7150 — Table A-2 DIM code checkpoints diagram (page 111)
Abb. 164 · Table A-2 DIM code checkpoints

Table A-2 DIM code checkpoints

2A Initialize different buses and perform the following functions:

1. Restart the ATCA-7150.
2. Replace the ATCA-7150.

z Reset, Detect, and Disable (function 0)

z Static Device Initialization (function 1)

z Boot Output Device Initialization (function 2)

Function 0 disables all device nodes, PCI devices, and PnP ISA cards. It also assigns PCI bus numbers.

Function 1 initializes all static devices that include manually configured onboard peripherals, memory and I/O decode windows in PCI-PCI bridges, and noncompliant PCI devices. Static resources are also reserved.

Function 2 searches for and initializes any PnP, PCI, or AGP video devices.

38 Initialize different buses and perform the following functions:

z Boot Input Device Initialization (function 3)

z IPL Device Initialization (function 4)

z General Device Initialization (function 5)

Function 3 searches for and configures PCI input devices and detects whether the system has the standard keyboard controller.

Function 4 searches for and configures all PnP and PCI boot devices.

Function 5 configures all onboard peripherals that are set to an automatic configuration and configures all remaining PnP and PCI devices.

Checkpoint Description Solution

Page 112 of the Emerson ATCA-7150 user manual — A.15 ACPI Code Checkpoints
Seite 112 · Zum Vergrößern klicken
Seite 112
Emerson ATCA-7150 — A.15 ACPI Code Checkpoints diagram (page 112)
Abb. 165 · A.15 ACPI Code Checkpoints

A.15 ACPI Code Checkpoints

ACPI checkpoints are displayed when an ACPI capable OS either enters or leaves a sleep state.

Table A-3 lists the types of checkpoints that may occur during ACPI sleep or wake states and solutions.

Table A-3 ACPI code checkpoints

Emerson ATCA-7150 — A.15 ACPI Code Checkpoints diagram (page 112)
Abb. 166 · A.15 ACPI Code Checkpoints

AC First ASL check point. Indicate that the system is running in ACPI mode.

AA Indicate that the system is running in ACPI mode.

01, 02, 03, 04, 05 Enter sleep state S1, S2, S3, S4, or S5. 1. Restart the ATCA-7150.

10, 20, 30, 40, 50 Wake from sleep state S1, S2, S3, S4, or S5.

Page 113 of the Emerson ATCA-7150 user manual — B.2 Related Specifications
Seite 113 · Zum Vergrößern klicken
Seite 113
Emerson ATCA-7150 — B Related Documentation diagram (page 113)
Abb. 167 · B Related Documentation

B.1 Emerson Network Power - Embedded Computing Documents

The Emerson Network Power - Embedded Computing publications listed below are referenced in this manual. You can obtain electronic copies of Emerson Network Power - Embedded Computing publications by contacting your local Emerson sales office. For documentation of final released (GA) products, you can also visit the following website: http://www.emersonnetworkpowerembeddedcomputing.com > Solution Services > Technical Documentation Search. This site provides the most up-to-date copies of Emerson Network Power - Embedded Computing product documentation.

Table B-1 Emerson Network Power - Embedded Computing Publications

Emerson ATCA-7150 — B.1 Emerson Network Power - Embedded Computing Documents diagram (page 113)
Abb. 168 · B.1 Emerson Network Power - Embedded Computing Docum…

B.2 Related Specifications

For additional information, refer to the following table for related specifications. As an additional help, a source for the listed document is provided. Please note that, while these sources have been verified, the information is subject to change without notice.

Table B-2 Related Specifications

Emerson ATCA-7150 — B.2 Related Specifications diagram (page 113)
Abb. 169 · B.2 Related Specifications
Page 114 of the Emerson ATCA-7150 user manual — B Related Documentation
Seite 114 · Zum Vergrößern klicken
Seite 114
Emerson ATCA-7150 — B Related Documentation diagram (page 114)
Abb. 170 · B Related Documentation

Table B-2 Related Specifications (continued)

Emerson ATCA-7150 — B Related Documentation diagram (page 114)
Abb. 171 · B Related Documentation
Page 115 of the Emerson ATCA-7150 user manual — B Related Documentation
Seite 115 · Zum Vergrößern klicken
Seite 115
Page 115 of the Emerson ATCA-7150 user manual — B Related Documentation
Page 116 of the Emerson ATCA-7150 user manual — HOW TO REACH LITERATURE AND TECHNICAL SUPPORT:
Seite 116 · Zum Vergrößern klicken
Seite 116

HOW TO REACH LITERATURE AND TECHNICAL SUPPORT:

Tempe, Arizona, USA 1 800 759 1107 1 602 438 5720

Munich, Germany +49 89 9608 0

For literature, training, and technical assistance and support programs, visit www.emersonnetworkpowerembeddedcomputing.com

Emerson Network Power. The global leader in enabling Business-Critical Continuity™

www.emersonnetworkpowerembeddedcomputing.com

AC Power Systems Connectivity DC Power Systems

Embedded Computing Embedded Power Integrated Cabinet Solutions

Outside Plant Power Switching & Control Precision Cooling

Services Site Monitoring Surge & Signal Protection

Emerson, Business-Critical Continuity, Emerson Network Power and the Emerson Network Power logo are trademarks and service marks of Emerson Electric Co. All other product or service names are the property of their respective owners. © 2008 Emerson Electric Co.

Frage zu Emerson ATCA-7150 stellen

Besitzer und unser Team antworten in der Regel innerhalb eines Tages – und Ihre Frage hilft auch anderen weiter.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Noch keine Fragen zu Emerson ATCA-7150

Stellen Sie die erste Frage — andere Nutzer oder unser Team antworten Ihnen.

Originaldokument

Emerson ATCA-7150 PDF-Anleitung

122 Seiten·3.3 MB·Netzteil·PDF
Klicken Sie oben auf eine Seite, um sie hier zu öffnen
Seite 1 / …
100%
Seiten werden geladen…