Embedded Computing for Business-Critical ContinuityTM


All rights reserved.
Emerson, Business-Critical Continuity, Emerson Network Power and the Emerson Network Power logo are trademarks and service marks of Emerson Electric Co. © 2008 Emerson Electric Co. All other product or service names are the property of their respective owners.
Intel® is a trademark or registered trademark of Intel Corporation or its subsidiaries in the United States and other countries.
Java™ and all other Java-based marks are trademarks or registered trademarks of Sun Microsystems, Inc. in the U.S. and other countries.
Microsoft®, Windows® and Windows Me® are registered trademarks of Microsoft Corporation; and Windows XP™ is a trademark of Microsoft Corporation.
PICMG®, CompactPCI®, AdvancedTCA™ and the PICMG, CompactPCI and AdvancedTCA logos are registered trademarks of the PCI Industrial Computer Manufacturers Group.
UNIX® is a registered trademark of The Open Group in the United States and other countries.
While reasonable efforts have been made to assure the accuracy of this document, Emerson assumes no liability resulting from any omissions in this document, or from the use of the information obtained therein. Emerson reserves the right to revise this document and to make changes from time to time in the content hereof without obligation of Emerson to notify any person of such revision or changes.
Electronic versions of this material may be read online, downloaded for personal use, or referenced in another document as a URL to a Emerson website. The text itself may not be published commercially in print or electronic form, edited, translated, or otherwise altered without the permission of Emerson,
It is possible that this publication may contain reference to or information about Emerson products (machines and programs), programming, or services that are not available in your country. Such references or information must not be construed to mean that Emerson intends to announce such Emerson products, programming, or services in your country.
If the documentation contained herein is supplied, directly or indirectly, to the U.S. Government, the following notice shall apply unless otherwise agreed to in writing by Emerson.
Use, duplication, or disclosure by the Government is subject to restrictions as set forth in subparagraph (b)(3) of the Rights in Technical Data clause at DFARS 252.227-7013 (Nov. 1995) and of the Rights in Noncommercial Computer Software and Documentation clause at DFARS 252.227-7014 (Jun. 1995).
Emerson Network Power - Embedded Computing
Lilienthalstr. 15
© 2008 Emerson · 85579 Neubiberg/Munich · Germany



This document describes the ATCA-7150 and RTM-ATCA-7150 server suite (hereinafter referred to as the ATCA-7150 and RTM-ATCA-7150 suite) in the following aspects:
z Functions, features, and appearance of the ATCA-7150 and RTM-ATCA-7150
z How to install, deploy, and maintain the ATCA-7150 and RTM-ATCA-7150
The user must be a professional engineer in the server device field, who has been trained and is able to identify danger levels when operating the device.
The body part focuses on the operation process, while the appendix part contains a lot of supporting information. This helps you to get the required information quickly and accurately.
This manual is divided into the following chapters and appendices.
z Safety Notes on page 17 lists safety notes applicable to the blade.
z Sicherheitshinweise on page 23 is the German translation of the previous English safety notes (this had to be included for legal reasons).
z Chapter 1, Introduction, on page 29 describes the main features of the ATCA-7150 and RTM-ATCA-7150.
z Chapter 2, Installation of the RTM-ATCA-7150, on page 35 describes the installation of the RTM.
z Chapter 3, Hardware Installation of ATCA-7150, on page 69 describes installation prerequisites including the blade installation itself of the front blade.
z Troubleshooting on page 99 provides troubleshooting information.
z Related Documentation on page 119 provides links to further ATCA-7150 and RTM-ATCA- 7150-related documentation.


This document uses the following abbreviations:



The following table describes the conventions used throughout this manual.

0x00000000 Typical notation for hexadecimal numbers (digits are 0 through F), for example used for addresses and offsets
0b0000 Same for binary numbers (digits are 0 and 1)
Screen Used for on-screen output and code related elements or commands in body text
Courier + Bold Used to characterize user input and to separate it from system output
Reference Used for references and for table and figure descriptions
[text] Notation for software buttons to click on the screen and parameter description



... Repeated item for example node 1, node 2, ..., node 12
Omission of information from example/command that is not necessary at the time being
Indicates a hazardous situation which, if not avoided, could result in death or serious injury
Indicates a hazardous situation which, if not avoided, may result in minor or moderate injury
This manual has been revised and replaces all prior editions.

6806800G42B December 2008 Updated to Emerson layout, editorial changes


We welcome and appreciate your comments on our documentation. We want to know what you think about our manuals and how we can make them better.
Mail comments to us by filling out the following online form: http://www.emersonnetworkpowerembeddedcomputing.com/ > Contact Us > Online Form
In "Area of Interest" select "Technical Documentation". Be sure to include the title, part number, and revision of the manual and tell us how you used it.




This section provides warnings that precede potentially dangerous procedures throughout this manual. Instructions contained in the warnings must be followed during all phases of operation, service, and repair of this equipment. You should also employ all other safety precautions necessary for the operation of the equipment in your operating environment. Failure to comply with these precautions or with specific warnings elsewhere in this manual could result in personal injury or damage to the equipment.
Emerson Network Power intends to provide all necessary information to install and handle the product in this manual. Because of the complexity of this product and its various uses, we do not guarantee that the given information is complete. If you need additional information, ask your Emerson Network Power representative.
The product has been designed to meet the standard industrial safety requirements. It must not be used except in its specific area of office telecommunication industry and industrial control.
Only personnel trained by Emerson Network Power or persons qualified in electronics or electrical engineering are authorized to install, remove or maintain the product.
The information given in this manual is meant to complete the knowledge of a specialist and must not be used as replacement for qualified personnel.
Keep away from live circuits inside the equipment. Operating personnel must not remove equipment covers. Only Factory Authorized Service Personnel or other qualified service personnel may remove equipment covers for internal subassembly or component replacement or any internal adjustment.
Do not install substitute parts or perform any unauthorized modification of the equipment or the warranty may be voided. Contact your local Emerson Network Power representative for service and repair to make sure that all safety features are maintained.
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications.


Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. Changes or modifications not expressly approved by Emerson Network Power Embedded Computing could void the user's authority to operate the equipment. Board products are tested in a representative system to show compliance with the above mentioned requirements. A proper installation in a compliant system will maintain the required performance. Use only shielded cables when connecting peripherals to assure that appropriate radio frequency emissions compliance is maintained.
Damage of the Product Surface of the Product High humidity and condensation on the product surface causes short circuits. Do not operate the product outside the specified environmental limits. Make sure the product is completely dry and there is no moisture on any surface before applying power. Do not operate the product below -5°C.
Overheating and Damage of the Product Operating the product without forced air cooling may lead to overheating and thus damage of the product. When operating the product, make sure that forced air cooling is available in the shelf.
Malfunction of the Product Reserved jumpers might carry production-related functions and can cause the product to malfunction if their setting is changed. Therefore, do not change settings of jumpers marked as "Reserved".


Damage of the Product and Additional Devices and Modules Incorrect installation or removal of additional devices or modules may damage the product or the additional devices or modules. Before installing or removing additional devices or modules, read the respective documentation.
Damage of Circuits Electrostatic discharge and incorrect installation and removal of the product can damage circuits or shorten their life. Before touching the product or electronic components, make sure that your are working in an ESD-safe environment.
Damage of the Product Incorrect installation of the product can cause damage of the product. Only use handles when installing/removing the product to avoid damage/deformation to the face plate and/or PCB.
Damage to the Product/Backplane or System Components Bent pins or loose components can cause damage to the product, the backplane, or other system components. Therefore, carefully inspect the product and the backplane for both pin and component integrity before installation.


Emerson Network Power Embedded Computing (ENPEC) and our suppliers take significant steps to ensure there are no bent pins on the backplane or connector damage to the boards prior to leaving the factory. Bent pins caused by improper installation or by inserting boards with damaged connectors could void the ECC warranty for the backplane or boards.
Incorrect installation of the product can cause blade damage. Only use handles for when installing/removing the product to avoid damage/deformation to the face plate and/or PCB
Damage of the Product The RJ-45 connector(s) on the face plate are either twisted-pair Ethernet (TPE) or E1/T1/J1 interfaces. Connecting an E1/T1/J1 line to an Ethernet connector may damage the product.
z Make sure that TPE connectors near your working area are clearly marked as network connectors.
z Verify that the length of an electric cable connected to a TPE bushing does not exceed 100 meters.
z Make sure the TPE bushing of the product is connected only to safety extra low voltage circuits (SELV circuits). If in doubt, ask your system administrator.
This product is a Class 1 laser product. The use of controls or adjustments or performance of procedures other than those specified herein may result in hazardous radiation exposure.
Always dispose of used blades, system components and RTMs according to your country’s legislation and manufacturer’s instructions.


Board/System damage Incorrect exchange of lithium batteries can result in a hazardous explosion. When exchanging the on-board lithium battery, make sure that the new and the old battery are exactly the same battery models. If the respective battery model is not available, contact your local Emerson Network Power sales representative for the availablity of alternative officially approved battery models.




The ATCA-7150 and RTM-ATCA-7150 server blade suite features the capabilities of high speed calculation and mass data processing.
The ATCA-7150 and RTM-ATCA-7150 suite consists of:
z ATCA-7150 and RTM-ATCA-7150
z RTM-ATCA-7150 The RTM-ATCA-7150 is the rear transition module (RTM) of the server blade.
A server blade must work with an RTM of the server blade. For example, the ATCA-7150 works with the RTM-ATCA-7150.
You can install the ATCA-7150 in any node slot of your shelf. The RTM-ATCA-7150 is installed in the slot that is paired with the ATCA-7150 slot.


Figure 1-1 shows the connection between the ATCA-7150 and the RTM of the server blade.
Figure 1-1 Connection Between the ATCA-7150 and the RTM

You can choose to use the RTM-ATCA-7150 according to the actual application.
The backplane is one part of the shelf. For details on the backplane and shelf, refer to the respective system documentation.


Table 1-1 lists the functions of the ATCA-7150 and the RTM.
Table 1-1 Functions of the ATCA-7150 and the RTM
Processing functions z Supports two dual-core LV Intel Xeon 5138 (2.13 GHz) processors
z Supports 4 MB L2 cache
z Supports up to four FB-DIMMs
z Supports the DIMM with a capacity of 512 MB, 1 GB, 2 GB, or 4 GB. The maximum capacity is 16 GB
Interface functions z 10/100/1000Base-T
z Provides two USB 2.0 interfaces (compatible with USB 1.1)
z Provides one IPMC serial port (also used as the system serial port, the serial port standards are RS232 and RJ-45)
z Provides serial port to access CPU and IPMC serial console
z Provides two SAS hard disks
z The RTM-ATCA-7150 that works with the ATCA-7150 provides a monitor interface and a USB 2.0 interface (compatible with USB1.1). Through optional daughter cards, the RTM-ATCA-7150 can also provide external GE interfaces, and FC interfaces.
Management functions The ATCA-7150 provides the IPMC that is powered independently. The IPMC is connected to the ShMC through the redundant IPMB.
The IPMC provides the following functions:
z Environmental sensors temperature, voltage
z System Event Logs
z Power-on, power-off, cold reset
z SOL(Serial Over LAN)
z FRU Hot-swap management
Integrity functions z Dual-channel GE controller
z SAS storage controller


This product meets the following standards.
Table 1-2 Standard Compliances

EMC requirements (legal) on system level (predefined Emerson Network Power system)
PICMG 3.0 Defines mechanics, blade dimensions, power distribution, power and data connectors, and system management
When ordering board variants or board accessories, use the order numbers given on the following pages.


The following table explains the product nomenclature used for the available board variants.
Table 1-3 Product Nomenclature

ATCA-7150-0GB ATCA Processor Blade with Dual Core Intel® Xeon® Processor LV5138.
Can be equipped with up to 16GB DDR2 memory.
ATCA-7X50-MEM-2G 2G Memory Module (min 1, max 4 modules of the same type per blade)
ATCA-7X50-MEM-4G 4G Memory Module (min 1, max 4 modules of the same type per blade)
RTM-ATCA-7150-GE Rear Transition Module for ATCA-7150, 2x 1G Ethernet
RTM-ATCA-7150-GE-FC Rear Transition Module for ATCA-7150, 2x 1G Eth, 2x FC
ATCA-7150-8GB-1HDD1 ATCA Processor Blade with Dual Core Intel® Xeon® Processor LV5138, 8GB (4x 2GB) Memory, 1x Enterprise Class HDD, SAS, 72GB
As of the printing date of this manual, the following board accessories were available.
Table 1-4 Available Board Accessories



Table 1-4 Available Board Accessories (continued)



This chapter describes:
z Unpacking and inspecting RTM-ATCA-7150
z Precautions during the operation
z Preparations before installation
z Installing and replacing daughter cards
z Connection of external cables

Damage of Circuits Electrostatic discharge and incorrect installation and removal of the product can damage circuits or shorten their life. Before touching the product or electronic components, make sure that your are working in an ESD-safe environment.
To inspect the shipment, perform the following steps.
z Installation procedure · z Removal procedure


The product is thoroughly inspected before shipment. If any damage occurred during transportation or any items are missing, please contact our customer's service immediately.
The following environmental and power requirements are applicable to the board.
Table 2-1 Environmental Requirements RTM-ATCA-7150
Temperature +5ºC (41ºF) to +40ºC (104ºF) (normal operation) according to NEBS Standard GR-63-CORE
-40ºC (-40ºF) to +70ºC (158ºF) (may be further limited by installed accessories)
-5ºC to +55ºC (short term operation) according to NEBS Standard GR-63-CORE
Temp. Change +/- 0.25ºC/min or 15ºC/h (59ºF/h) according to NEBS Standard GR-63-CORE
+/- 0.25ºC/min or 15ºC/h (59ºF/h)
Rel. Humidity 5% to 85% non-condensing according to Emerson Network Power Embedded Computing-internal environmental requirements
5% to 85% non-condensing according to Emerson Network Power Embedded Computing-internal environmental requirements
Requirement Operating Non-Operating · Altitude


Table 2-1 Environmental Requirements RTM-ATCA-7150 (continued)

Vibration 1.0g from 5 to 100 Hz and back to 5 Hz at a rate of 0.1 octave/minute
Random 5-20 Hz @ 1 m2/Sec3
Shock Half-sine, 11 m/Sec, 30mSec/sec2 Blade level packaging
1.0m (Packaged) per ETSI 300 019-2-2 (Blade level packaging)
Table 2-2 Power Requirements RTM-ATCA-7150




Personal Damage through Electric Shock There is current in the power cords and communication cables. Touching the connectors of the power cords and communication cables may cause electric shock. Do not touch the connectors of power cords and communication cables

Damage of Circuits Electrostatic discharge and incorrect installation and removal of the product can damage circuits or shorten their life. Before touching the product or electronic components, make sure that your are working in an ESD-safe environment.
Module Damage If the blade is not fully aligned with the interface in the backplane, too much force may twist the pins on the blade or backplane. Do not exert too much force when you insert the blade.
z Make sure that you wear an electrostatic discharge (ESD)-preventive wrist strap to prevent the static electricity from hurting you or damaging the device.
z Keep your personal objects such as your clothes away from RTM-ATCA-7150. To prevent the static electricity on clothing, you need to put on antistatic clothing.
z RTM-ATCA-7150 is installed in the slot paired with the server blade slot at the back side of the shelf. You should install RTM-ATCA-7150 before the server blade is installed. Otherwise, RTM-ATCA-7150 cannot be powered on normally.


z Hold the ejector handles and the face plate when you insert or remove RTM-ATCA-7150. Do not touch the components inside of the blades.
z Keep the blade vertical when you install RTM-ATCA-7150. Align the blade with the slot and then insert it in the shelf.
RTM-ATCA-7150 is powered by the server blade in the slot paired with the RTM-ATCA-7150 slot. RTM-ATCA-7150 does not support hot swap. The face plate of ATCA-7150 and RTM-ATCA- 7150 provides an upper and a lower ejector handles. The ejector handles help to insert, remove, fasten, power on, and power off RTM-ATCA-7150.
Static electricity may hurt you or damage the device. To minimize the damage, pay attention to the following points:
z Before you operate the device, wear the ESD-preventive wrist strap. Both terminals of the ESD-preventive wrist strap must contact well. One terminal touches your bare skin, and the other is inserted in the jack at the front or back side of the shelf. For details on how to wear the ESD-preventive wrist strap, refer Wearing the ESD-Preventive Wrist Strap.
z Avoid moving your body as much as possible. Movement gathers static electricity around you.
z Do not touch the solder point, pin, or bare circuit.
z Do not leave the device in the place where others can operate it.
z Install the device at once after you take it out of the antistatic package. If you need to lay down the device, place it back in the antistatic package. Do not lay the device on the shelf or cabinet.
z Monitor the temperature and humidity of the equipment room. Warm air decreases the humidity and increases the static electricity in the room.


The installation preparations process includes:
z check the installation environment
z wear the ESD-preventive wrist strap
z remove the blank filler panels
z unpack and check the RTM-ATCA-7150 suite

z Electrostatic discharge can damage circuits or shorten their life.
z The ESD-preventive wrist strap prevents only the static electricity on your body from damaging the blade. To prevent the static electricity on your clothes, it is recommended to wear the antistatic clothes. Additionally, you have to make sure that the cabinet and shelf are properly grounded - for details, refer to the corresponding system documentation.


To wear the ESD-preventive wrist strap, proceed as follows:
There is a jack for inserting the ESD-preventive wrist strap respectively in the lower right corners at both front and back sides of the shelf.
Figure 2-1 Wearing the ESD-Preventive Wrist Strap



After a filler blade is removed, place it in the equipment room or other moisture-proof and dust-proof places.
You should install a blank filler blade in the slot after removing the blade. Otherwise, it may effect the ventilation, heat dissipation, electromagnetic shielding and dust prevention of the shelf.
If this is the first installation for the shelf, the blade is fully configured and the shelf is not powered on, you can remove all the filler blades. Then, install blades in the slots in order. This document takes the first installation as an example.
If you want to install multiple blades in the shelf that is powered on shelf, you can remove a filler blade and then install a blade one by one.
If the slot is occupied with a filler blade you have to remove it first.


To remove the filler blade, proceed as follows:
Figure 2-2 Removing the Filler Blade



Incorrect installation or removal of additional devices or modules may damage the product or the additional devices or modules. Before installing or removing additional devices or modules, read the respective documentation.
Electrostatic discharge and incorrect installation and removal of the product can damage circuits or shorten their life. Before touching the product or electronic components, make sure that your are working in an ESD-safe environment.
Do not exert too much force when you insert the blade. If the blade is not fully aligned with the interface in the backplane, too much force may twist the pins on the blade or backplane.

Do not touch the connectors of power cords and communication cables. There is current in the power cords and communication cables. Touch on the connectors of the power cords and communication cables may cause electric shock.
z Make sure that you wear an electrostatic discharge (ESD)-preventive wrist strap to prevent the static electricity from hurting you or damaging the device.
z Keep the area where the components reside clean and keep the components away from the heat-generating devices, such as radiators.


z Ensure that your sleeves are tightened or rolled up above the elbow. For safety purpose, it is not recommended to wear jewelry, watch, glasses with metal frame, or clothes with metal buttons.
z Do not exert too much force, or insert or remove the components forcibly. Avoid damage to the components or plug-ins, for example, the pins are bent or get short circuit.
Before you install or replace a component, make the following preparations
z Confirming the feasibility of the operation
— There are available spare parts of the component to be installed or replaced in the equipment warehouse. When the available spare parts are in short supply, contact Emerson Network Power Embedded Computing for help in time.
— Make sure that the new component is in good condition, without defects such as oxidation, chemical corrosion, missing component, or transportation damage.
— By reading this document, you are familiar with how to install and replace the component and master the skills required by the operation.
z Checking the environment Make sure that the shelf, power supply, temperature, and humidity meet the operating requirements of the blades and components. For details, refer to ATCA-7150 Installation and Use Manual and other related documents.
z Preparing spare parts and tools
— Prepare the component to be installed or replaced. When you hold or transport the component, use the special antistatic package. In addition, you need to tidy, record, and repair the component during routine maintenance.
— Prepare the cross screwdriver, screws, plastic supports, cooling gel, and ESD- preventive wrist strap. The supplier provides a list of tools and negotiates with you to decide the tool provider.
z Confirming installation or changing positions Confirm the positions of the cabinet, the shelf, and the slot where RTM-ATCA-7150 is installed. Then, stick a label on the face plate of RTM-ATCA-7150 to avoid wrong operation.


z Others If a serious problem occurs and cannot be solved when you install or replace the component, contact Emerson Network Power Embedded Computing for technical support.
This manual considers the GE daughter card providing two external Ethernet interfaces as an example, and describes how to install the daughter card on and remove it from RTM-ATCA- 7150.


When the GE daughter card is used with the RTM-ATCA-7150 it can be installed on the daughter card connector J1, J2, J3, J4. The default position as used on the RTM-ATCA-7150-GE is position J4. The default position as used on the RTM-ATCA-7150-GE-FC is position J1.
Figure 2-3 Structure of RTM-ATCA-7150



To install the GE daughter card, proceed as follows.




card is fastened by the plastic latches. See step 3 in the figure below.
Figure 2-4 Installing the GE Daughter Card



After installation, check if RTM-ATCA-7150 can be powered on and work normally. Use the network cable to connect RTM-ATCA-7150 to the external network. Check if the network is connected properly and monitor whether the network port indicator is normal.
To replace the GE daughter card, proceed as follows.


Figure 2-5 Replacing the GE Daughter Card.



After replacement, check if RTM-ATCA-7150 can be powered on and work normally. Use the network cable to connect RTM-ATCA-7150 to the external network. Check if the network is connected properly and monitor whether the network port indicator is normal.
This manual considers the FC daughter card providing two external FC interfaces as an example, and describes how to install the daughter card on and remove it from RTM-ATCA- 7150.
When the FC daughter card is used with the RTM-ATCA-7150 it can be installed on the daughter card connector J2, J4. The default position as used on the RTM-ATCA-7150-GE-FC is position J4 and J1.
To install the FC daughter card, proceed as follows.






card is fastened by the plastic latches. See step 3 in the figure below.
Figure 2-6 Installing the FC Daughter Card



information refer, Installing RTM-ATCA-7150.
After installation, check if RTM-ATCA-7150 can be powered on and work normally. Use the optical fiber to connect RTM-ATCA-7150 to the external storage system. Check if RTM-ATCA- 7150 can transmit data normally and monitor whether the FC status indicator is normal.
To replace the FC daughter card, proceed as follows.


Figure 2-7 Replacing the FC Daughter Card.



After replacement, check if RTM-ATCA-7150 can be powered on and work normally. Use the optical fibre to connect RTM-ATCA-7150 to the external storage system. Check if RTM-ATCA- 7150 can transmit data normally and monitor whether the FC status indicator is normal.

Product Damage You can install RTM-ATCA-7150 into a system if the front blade is already installed or if it is not installed. In case the front blade is already installed, its payload has to be powered down first.


The following procedure describes the installation of RTM-ATCA-7150. It assumes that your system is powered on. If your system is powered off, you can disregard the blue LED and thus skip the respective step. In this case it is a purely mechanical installation. The same applies to an installation without an installed front blade. In this case disregard the LEDs and skip the respective step.


Figure 2-8 Installing RTM-ATCA-7150




Product Damage You should power off the front blade before removing RTM-ATCA-7150.
To remove RTM-ATCA-7150, proceed as follows:


Figure 2-9 Removing RTM-ATCA-7150

After RTM-ATCA-7150 is installed in the shelf, you can connect the keyboard, video, and mouse (KVM) cables.


If RTM-ATCA-7150 is configured with the GE daughter card and FC daughter card, it provides the external GE network ports and external FC interfaces. Network cables and optical fibers can be connected to RTM-ATCA-7150. You can choose to use one or more daughter cards according to actual applications.

z There is a back cable trough at the back side of the shelf. You need to arrange and identify all cables and then bind and fasten them in the back cable through after connecting them.
z If you use excessive force when installing cables, the cables may be damaged.
z Do not exert too much force when you insert or remove the cables. Do not twist or tear the cables in any condition.
The figure below shows the method of connecting the Keyboard, Video, Mouse (KVM) cables to RTM-ATCA-7150. Please refer to your local Emerson sales representative to obtain the cable.

Product Damage You have to use matching interfaces for the KVM cables. Use a PS/2-USB converter when connecting the KVM cables.


Figure 2-10 Connecting the KVM Cables to RTM-ATCA-7150


Electromagnetic Radiation Make sure that the cable and connectors of the network cable are with shielding function and that both ends of the shielded layer of the network cable are grounded. It is recommended that the network cable is grounded through the metal cover of the network port connector.
When RTM-ATCA-7150 is configured with the GE daughter card, it provides two external Ethernet interfaces with 10/100/1000M Base-T auto-negotiation. Network cables are used to connect RTM-ATCA-7150 to the external network. Please refer to your local Emerson sales representative to obtain the cable.


The figure below shows the method of connecting the network cables to RTM-ATCA-7150.
Figure 2-11 Connecting the Network Cables to RTM-ATCA-7150

When RTM-ATCA-7150 is configured with the FC daughter card, it provides two external 2G FC interfaces. Optical fibers are used to connect RTM-ATCA-7150 to the external Storage Area Network (SAN) storage system. Please refer to your local Emerson sales representative to obtain the cable.


As shown in steps 1 and 2 in the figure below, insert the optical module in the FC interface and then insert the optical fibers in the optical module.
Figure 2-12 Connecting the Optical Fibers to RTM-ATCA-7150





This chapter describes:
z Unpacking and inspecting the blade
z Environmental and power requirements
z Precautions during the operation
z Checking the installation environment
z Installation and removal procedures

Damage of Circuits Electrostatic discharge and incorrect installation and removal of the blade can damage circuits or shorten their life. Before touching the blade or electronic components, make sure that you are working in an ESD-safe environment.
To inspect the shipment, perform the following steps.
z Installing accessories · z Ejector handles · Shipment Inspection


according to your country’s legislation.
The blade is thoroughly inspected before shipment. If any damage occurred during transportation or any items are missing, please contact our customer's service immediately.
To unpack and check the ATCA-7150 suite, proceed as follows:
Table 3-1 List of Packing Items

1 Packing materials, such as packing carton, plastic package, and foam
2 Documentation bag, containing documents shipped with the product
3 ATCa-7150, which can be used with an RTM-ATCA-7150
4 RTM-ATCA-7150, which must be used with an ATCA-7150
z The actual items in the packing carton are decided by the contract.
z If you do not order an RTM of the server blade, all functions provided by the RTM are not available.
Unpacking the Blade


The following environmental and power rewuirements are applicable to the blade.
Table 3-2 Environmental Requirements

Temperature +5ºC (41ºF) to +40ºC (105ºF) (normal operation) according to NEBS Standard GR- 63-CORE
The SAS drives can meet this max temperature range of non-operating.
-5ºC to +55ºC (exceptional operation) according to NEBS Standard GR-63-CORE
Temp. Change +/- 0.25ºC/min according to NEBS Standard GR-63-CORE
Rel. Humidity 5% to 85% non-condensing according to Emerson Network Power-internal environmental requirements
5% to 95% non-condensing according to Emerson Network Power-internal environmental requirements
Vibration 0.1g from 5 to 100 Hz and back to 5 Hz at a rate of 0.1 octave/minute
Random 5-20 Hz at 1 m2/Sec3
Shock Half-sine, 11 m/Sec, 30mSec/sec2 Blade level packaging


Table 3-2 Environmental Requirements (continued)

Free Fall 1,200 mm (Packaged) /all edges and corners
1.0m (Packaged) per ETSI 300 019-2-2 (Blade level packaging)
Make sure that the blade is used in an AdvancedTCA shelf connected to -48VDC up to -60VDC, according to Telecommunication Network Voltage (TNV-2). A TNV-2 circuit is a circuit whose normal operating voltages exceed the limits for a safety-extra-low-voltage (SELV) under normal operating conditions, and which is not subject to overvoltages from telecommunication networks.
Table 3-3 lists the power requirements for the ATCA-7150.
Table 3-3 Power Requirements

The blade provides two independent power inputs according to the AdvancedTCA specification.


Electric Shock There is current in the power cords and communication cables. Touching the connectors of the power cords and communication cables may cause electric shock. Do not touch the connectors of power cords and communication cables.
Electrostatic Discharge Do not touch the circuit board with bare hands. The static electricity of the human body may damage the electrostatic sensitive devices (ESSDs) on the circuit board. Make sure that you wear an electrostatic discharge (ESD)-preventive wrist strap or antistatic glove to prevent the static electricity from hurting you or damaging the device. Keep your personal objects such as your clothes away from the ATCA-7150 suite. To prevent the static electricity from damaging the device, it is recommended to wear antistatic clothes.
Pin Damage If the blade is not fully aligned with the interface in the backplane, too much force may twist the pins on the blade or backplane. Do not exert too much force when you insert the blade.
z If an RTM is planned to be used, you must install the RTM in the slot before installing the ATCA-7150 in the paired slot. If the ATCA-7150 is installed first and shelf power is turned on the RTM must not be installed in the paired slot.
z To take the ATCA-7150 suite, hold the captive screw on the top of the face plate with one hand and the lower edge of the blade with the other hand. Do not touch the components of the blade.


Static electricity may hurt you or damage the device. To minimize the damage, pay attention to the following points:
z Before you operate the device, wear the ESD-preventive wrist strap. Both terminals of the ESD-preventive wrist strap must contact well. One terminal touches your bare skin, and the other is inserted in the jack at the front or back side of the shelf. For details on how to wear the ESD-preventive wrist strap, see Wearing the ESD-Preventive Wrist Strap on page 75.
z Avoid moving as much as possible. Movement gathers static electricity around you.
z Do not touch the solder point, pin, or bare circuit.
z Do not leave the device in the place where others can operate it.
z Install the device at once after you take it out of the antistatic package. If you need to lay down the device, place it back in the antistatic package. Do not lay the device on the shelf or cabinet.
z Monitor the temperature and humidity of the equipment room. Warm air decreases the humidity but increases the static electricity in the room.

Damage of Circuits Electrostatic discharge and incorrect module installation and removal can damage circuits or shorten their life. Before touching the module or electronic components, make sure that you are working in an ESD-safe environment.


Table 3-4 lists the environment for installing the ATCA-7150 suite.
Table 3-4 Environment for Installing the ATCA-7150 Suite

Leave enough space around the cabinet. Nothing blocks the fans and air conditioner to ensure airflow and heat dissipation.
Consider heat dissipation when you choose slots to install blades. If the shelf is not fully configured, install the blades in scattered slots.

Product Damage Electrostatic discharge can damage circuits or shorten their life. The ESD-preventive wrist strap prevents only the static electricity on your body from damaging the blade. To prevent the static electricity on your clothes, it is recommended to wear the antistatic clothes. Additionally, you have to make sure that the cabinet and shelf are properly grounded - for details, refer to the respective system documentation.
The cable of an ESD-preventive wrist strap is limited. In this case, before you wear the ESD- preventive wrist strap, place the device within 0.5 m away from the shelf.


To wear the ESD-preventive wrist strap, proceed as follows:
Figure 3-1 Wearing the ESD-Preventive Wrist Strap



z After you remove a blank filler blade, store it in the equipment room or a damp-proof and dust-proof place.
z After you remove a blade from the shelf, install a blank filler blade in vacant slot. Otherwise, the functions such as ventilation, heat dissipation, electromagnetic shield, and dust proof may be affected.
z For a newly-delivered shelf, you can remove all blank filler blades and then install blades in all slots when the shelf is not powered on.
z If a shelf is powered on, you can remove a blank filler blade and then install a blade. In this way, install multiple blades one by one.


Before you install the ATCA-7150 suite, remove blank filler blades from installation slots as follows:
Figure 3-2 Removing the Blank filler blade




Electric Shock There is current in the power cords and communication cables. Touching the connectors of the power cords and communication cables may cause electric shock. Do not touch the connectors of power cords and communication cables.
When you install or replace components, pay attention to the following points:
z Wear the ESD-preventive wrist strap to prevent the static electricity from damaging the device.
z Keep the area where the components reside clean and keep the components away from the heat generating devices, such as radiator.
z Ensure that your sleeves are tightened or rolled up above the elbow. For safety purpose, it is not recommended to wear jewelry, watch, glasses with metal frame, or clothes with metal buttons.
z Do not exert too much force, or insert or remove the components forcibly. Avoid damage to the components or plug-ins.

Only those who are certificated or authorized by Emerson Network Power can replace or change the components.


Table 3-5 lists the optional components supported by the ATCA-7150.
Table 3-5 Optional Components Supported by the ATCA-7150 Suite

For more information on the daughter cards, refer to RTM-ATCA-7150 Installation and Use Manual, MESC-RTM-7150-FC Installation Information, and MESC-RTM-7150-GE Installation Information.
Before you install or replace the component, make the following preparations:
z Confirming the feasibility of the operation
— There are available spare parts of the component to be installed or replaced in the equipment warehouse. When the available spare parts are lacking, contact Emerson Network Power for help in time. For details on how to get help from Emerson Network Power, see Contacting Emerson Network Power for Technical Support on page 100.
— Make sure that the new component is in good condition, without defects such as oxidation, chemical corrosion, missing component, or transportation damage.
— By reading this document, you are familiar with how to install and replace the component and master the skills required by the operation.
z Checking the environment Make sure that the shelf, power supply, temperature, and humidity meet the operating requirement for the blades and components. For details, refer to the respective system documentation.


z Preparing spare parts and tools
— Prepare the component to be installed or replaced. When you hold or transport the component, use the special antistatic package. Also, you need to tidy, record, and repair the component during routine maintenance.
— Prepare the cross screwdriver, screws, plastic supports, cooling gel, and ESD- preventive wrist strap. The supplier provides a list of tools and negotiates with to decide the tool provider.
z Confirming installation or changing position Confirm the positions of the cabinet, the shelf, and the slot where the ATCA-7150 is installed. Then, stick a label on the face plate of the ATCA-7150 to avoid wrong operation.
z Others If a serious problem occurs and cannot be solved when you install or replace the component, contact Emerson Network Power for technical support. For details on contact methods, see Contacting Emerson Network Power for Technical Support on page 100.
When you install or replace the DIMM, pay attention to the following points:
z The ATCA-7150 provides four DIMM interfaces and supports the DIMM with a capacity of 512 MB, 1 GB, 2 GB or 4 GB.
z The DIMMs must have the same size, frequency, type, and technology, physical design and manufacturer.
z DIMMs must be of single or dual rank type. Quad rank types are not supported.
z If the DIMMs are not fully configured, you need to install the required DIMMs in the related interfaces.
— If one DIMM is configured, install it in DIMM slot 0.
— If two DIMMs are configured, install them in DIMM slots 0 and 1.
— Configuring three DIMMs is not supported.


Figure 3-3 shows the positions of the DIMM interfaces on the ATCA-7150.
Figure 3-3 Positions of the DIMM Interfaces

Table 3-6 DIMM Configuration on the ATCA-7150

To install the DIMM, proceed as follows:



Product Damage Operate the fixing clips slightly to avoid breaking them or damaging the DIMM interface.
If there is a gap between the DIMM and the fixing clips, the DIMM is not installed properly. In this case, open the fixing clips and remove the DIMM. Then, insert the DIMM again.


Figure 3-4 Installing the DIMM

You can install the DIMMs in other DIMM interfaces in the same way.
After installation, insert the ATCA-7150 in the shelf and power on the ATCA-7150. Check whether the OS can be loaded properly. If it can be, in the OS, check whether the displayed memory capacity is consistent with the actual one.
To replace the DIMM, proceed as follows:


For details, see Removing the ATCA-7150 on page 95.

z To avoid breaking them or damaging the DIMM interface, do not exert too much power to operate the fixing clips.
z If you open the two fixing clips of the DIMM at the same time, the DIMM bounces from the interface. Operate the fixing clips carefully to avoid damaging the DIMM.


Figure 3-5 Removing the DIMM

After replacement, check whether the OS can be loaded properly. If it can be, in the OS, check whether the displayed memory capacity is consistent with the actual one.
This section describes how to install and replace the hard disk on the ATCA-7150.
For more information on the installation of the hard disk, refer to the HDD Installation Sheet.
To install the hard disk, proceed as follows:


You can install the other hard disk in the same way.


After installation, check whether the ATCA-7150 can be powered on and work normally and whether the data in the hard disk can be read and written normally.
Figure 3-6 Installing the Hard Disk



To replace the hard disk, proceed as follows:


After replacement, check whether the ATCA-7150 can be powered on and work normally and whether the data in the hard disk can be read and written normally.
Figure 3-7 Removing the Hard Disk



RTM-ATCA-7150 must be installed before the ATCA-7150 to avoid product damage. For information on how to install the RTM-ATCA-7150, refer to Chapter 2, Installation of the RTM- ATCA-7150, on page 35
The following procedure describes the installation of the blade. It assumes that your system is powered and if applicable the RTM is installed. If your system is unpowered, you can disregard the blue LED and thus skip the respective step. In this case it is a purely mechanical installation.


Figure 3-8 Installing the ATCA-7150

After you install the RTM of the server blade and the ATCA-7150, and connect and bind cables, check whether:
z The ATCA-7150 and RTM are installed in the paired slots.
z The upper and lower ejector handles of the RTM are fully closed.


z The cables are properly connected.
z The cables are well bound.

The RTM of the server blade is powered by the ATCA-7150 in the slot paired with the RTM slot. The RTM of the server blade does not support hot swap. Therefore, the RTM must be installed in the slot before the ATCA-7150 is installed in the paired slot.
Before power-on, you need to confirm that:
z The RTM of the server blade and SMM are installed properly.
z The shelf and SMM are powered on properly.
z The required external cables are connected.
z The upper and lower ejector handles of the ATCA-7150 are opened.
To power on the ATCA-7150, proceed as follows:


During power-on, if the HEALTHY LED blinks (red), an alarm occurs to the ATCA-7150.

z Before you remove an ATCA-7150 or RTM of the server blade, prepare packing materials, such as an antistatic package.
z Before you remove an ATCA-7150 or RTM of the server blade, power off the ATCA-7150. For details on how to power off the ATCA-7150, see Power Off on page 94.

The RTM of the server blade is powered by the ATCA-7150 in the slot paired with the RTM slot. The RTM of the server blade does not support hot swap. You can remove the RTM only when the ATCA-7150 is powered off and removed from the slot.


Before power-off, you need to confirm that:
z Data has been saved on the ATCA-7150.
z No application runs on the ATCA-7150.
z The ATCA-7150 has quitted the operating system (OS).
To power off the ATCA-7150, proceed as follows:
z The HOTSWAP LED blinks at the short blink rate and then is on (blue).
z The OOS LED is on (red or amber).
z The HEALTHY LED is off.
To remove the ATCA-7150, proceed as follows:


Figure 3-9 Removing the ATCA-7150

The ATCA-7150 supports hot swap. As shown in Figure 3-3, the face plate of the ATCA-7150 provides an upper and a lower ejector handles. The ejector handles help to insert, remove, power on, and power off the ATCA-7150.
Insertion and Removal


Table 3-7 describes the insertion and removal of the ATCA-7150 by using the ejector handles.
Table 3-7 Insertion and Removal of the ATCA-7150
Insert the ATCA-7150 The process for inserting the ATCA-7150 is as follows:
z When the ejector handles are not closed, the HOTSWAP LED is on and the ATCA-7150 is not powered on.
z After the ejector handles are closed, the HOTSWAP LED blinks at the long blink rate and the ATCA-7150 requests for activation.
z After activation, the ATCA-7150 is powered on and the HOTSWAP LED is off.
Remove the ATCA-7150 The process for removing the ATCA-7150 is as follows:
z When you open the ejector handles, the HOTSWAP LED blinks at the short blink rate and the ATCA-7150 requests for deactivation.
z After deactivation, the ATCA-7150 is ready for power-off.
z When the HOTSWAP LED is on, the ATCA-7150 is powered off. At this time, you can remove the ATCA-7150 by holding the ejector handles.
Table 3-8 describes the power-on and power-off of the ATCA-7150 by using the ejector handles.
Table 3-8 Power-On and Power-Off of the ATCA-7150

Power on theATCA-7150 Whether you close one ejector handle or both ejector handles, the ATCA- 7150 can be powered on and work well.
Power off the ATCA-7150 When both ejector handles are opened, you can power off the ATCA- 7150.
Operation Description · Power-On and Power-Off




This chapter describes:
z LED Display Exceptions
z Power-On Startup Exceptions

Before you remove the faults of the ATCA-7150 and RTM-ATCA-7150 suite, be familiar with the Server System Safety Information shipped with the shelf.
During troubleshooting, follow the principles:
z Diagnose the outside and then the inside. In troubleshooting, remove the outside faults, such as power interruption and the faults of the peer device.
z Diagnose the network and then the NEs (network Elements). According to the network topology, analyze whether the network environment is normal and the interconnected device is faulty. Locate the NE to which the fault occurs.
z Diagnose the high speed part and then the low speed part. From the alarm signal stream, the alarm of the high speed signal often causes the alarm of the low speed signal. Therefore, remove the fault of the high speed part first.


z Analyze the alarm of high level and then that of low level. Analyze the alarm of high level, such as critical alarm or major alarm. Then, analyze the alarm of low level, such as minor alarm or warning alarm.
You can use the following resources for troubleshooting:
z LEDs The ATCA-7150 suite provides the following LEDs:
— Out of Service (OOS) LED
— In Service (IS) LED
— Attention (ATN) LED
— Hotswap (H/S) LED
— Hard Disk (HDD) LED In addition, the external GE daughter card provides network port LEDs (for two Ethernet interfaces). The external FC daughter card provides FC status LEDs (for two FC interfaces). You can monitor the LEDs to diagnose the current status of the ATCA-7150 suite. For details on the LEDs of the ATCA-7150 suite, see the LED section in the ATCA-7150 Installation and Use manual.
z Generating error codes and alarm signals Error codes and alarm signals help you to further locate and remove the faults.
If a problem persists after you handle it under the guidance of this document, contact the local office or Customer Service Center of Emerson Network Power to obtain timely technical support. Before you report the problem to Emerson Network Power engineer, collect the following information:
z Detailed name and address of the customer
z Contact person and telephone number
z Time when the fault occurred


z Detailed description on the fault
z Device type and software version
z Measures taken after the fault occurred and related results
z Problem level and required solution time
The contact address of Emerson Network Power is:
Emerson Network Power - Embedded Computing GmbH
Lilienthalstr. 15
All LEDs on the ATCA-7150 face plate are off, including the OOS, IS, ATN, H/S, and HDD LEDs. At the same time, no information is displayed on the KVM.
To solve the problem, proceed as follows:


The IS LED of the ATCA-7150 blinks (red). The alarm severity varies with the blinking frequency. The higher the blinking frequency, the more serious the alarm.
The IS LED can be green or red. The working state of the ATCA-7150 decides the color of the LED.
The blinking frequency of the IS LED indicates the alarm level:
z For a minor alarm, the IS LED blinks at a frequency of 0.5 Hz.
z For a major alarm, the IS LED blinks at a frequency of 1 Hz.
z For a critical alarm, the IS LED blinks at a frequency of 4 Hz.
By using the SMM command, query the status and logs of the blade where the alarm occurs.
If an alarm occurs due to over high temperature, confirm that:
After you close the upper and lower ejector handles of the ATCA-7150, the HOTSWAP LED blinks (blue) and no information is displayed on the KVM.
To solve the problem, proceed as follows:
Solution · Description · Solution


The optional component that is newly installed cannot be used.
To solve the problem, proceed as follows:
The number of the displayed system DIMMs is less than that of the installed physical DIMMs.


To solve the problem, proceed as follows:
The ATCA-7150 cannot be started.
To solve the problem, proceed as follows:
Description · Solution


The ATCA-7150 automatically shuts down without any explicit reason.
To solve the problem, proceed as follows:
All keys or part keys on the keyboard cannot be used.
To solve the problem, proceed as follows:


The mouse cannot be used.
To solve the problem, proceed as follows:
When you connect the monitor to the running ATCA-7150 or start some applications of the ATCA-7150, the monitor remains dark.
To solve the problem, proceed as follows:


Jittering, unreadable, rolling or twisted image is displayed on the monitor screen.
To solve the problem, proceed as follows:
The ATCA-7150 LED is normal and no alarm is generated. However, no information is displayed on the monitor.


To solve the problem, proceed as follows:
z The RTM of the server blade is inserted properly.
z The upper and lower ejector handles are fully closed.
z The LEDs are in normal state.
The USB interface cannot be used.
To solve the problem, proceed as follows:
One or more ATCA-7150 cannot communicate with the external network.


To solve the problem, proceed as follows:
A fault may occur in software.
To solve the problem, proceed as follows:
When you diagnose the faulty ATCA-7150, check whether the ATCA-7150 or the shelf has a fault.
z If all ATCA-7150s have the same symptom, it is very likely that a fault occurs in the shelf. For details, refer to the respective system documentation.
z If the shelf has multiple ATCA-7150s and one ATCA-7150 is faulty, troubleshoot the faulty ATCA-7150.
Description · Solution


If you think that the fault is caused by software, see A Fault Occurs in Software on page 109.
Damaged CMOS data or BIOS codes may cause some uncertain problems. To reset the CMOS data, contact Emerson Network Power for technical support. For detailed contact methods, see Contacting Emerson Network Power for Technical Support on page 100.
Check whether the PEM of the shelf works well. If the PEM works well but the problem persists after you install the ATCA-7150 again, proceed as follows:
a. SOL daughter card
b. Hard disk drive
c. DIMM The hardware configurations enough to start the ATCA-7150 include:
z One 512 MB DIMM
When the ATCA-7150 is configured with only one DIMM, the DIMM can be installed in DIMM interface 0 only. For the postion of the DIMM interface, see Figure 3-3.
z One hard disk
z Main board · z One CPU · z Available shelf


a. Hard disk
b. DIMM
c. CPU
d. Main board
POST code checkpoints are the largest set of checkpoints during the BIOS pre-boot process.
Table A-1 lists the types of checkpoints that may occur during the POST stage of the BIOS and related solutions.
To clear the CMOS RAM or upgrade the BIOS, contact Emerson Network Power for technical support.
Table A-1 POST code checkpoints

03 Disable NMI, parity, video for EGA, and DMA controllers.
z BIOS modules on POST entry and GPNV area


Table A-1 POST code checkpoints (continued)
04 Check the CMOS diagnostic byte to determine whether battery power is proper and whether the CMOS checksum is proper. Verify the CMOS checksum by reading the storage area. If the CMOS checksum is wrong, update CMOS with power-on default values and clear passwords. Initialize data variables that are based on CMOS setup questions.
05 Initialize the interrupt controlling hardware and interrupt vector table.
06 Initialize the system timer. Initialize the handler for system timer interrupt.
08 Initialize the keyboard controller (KBC). 1. Restart the ATCA-7150
C1 Set the boot processor initialization information.
C2 Set the boot processor initialization for POST.
C5 List and set application processors.
C6 Re-enable cache for the boot processor.
C7 Exit the early CPU initialization.
0A Initialize the 8042 compatible KBC. 1. Restart the ATCA-7150.
0B Detect the presence of PS/2 mouse. 1. Restart the ATCA-7150
0C Detect the presence of the keyboard in KBC port.
0E Test and initialize different input devices. Also, update kernel variables. Disable handler for IRQ1 installation. Uncompress all available languages, BIOS logo, and silent logo modules.
Checkpoint Description Solution


Table A-1 POST code checkpoints (continued)
13 Initialize early POST chipset registers. 1. Restart the ATCA-7150.
24 Uncompress and initialize the specific BIOS modules of any platform.
30 Initialize system management interrupt. 1. Restart the ATCA-7150.
2E Initialize all output devices.
31 Allocate memory for the ADM module and uncompress it. Control the ADM module for initialization. Initialize the language and font modules for ADM. Activate the ADM module.
33 Initialize the silent boot module. Set the window for displaying text information.
37 Display the sign-on message, CPU information, setup key message, and any OEM specific information.
39 Initializes DMA controller 1 and DMA controller 2.
3A Initialize RTC date and time. 1. Restart the ATCA-7150.
Checkpoint Description Solution


Table A-1 POST code checkpoints (continued)
3B Test for total memory installed in the system. Also, Check for the Delete or ESC key to limit memory test. Display total memory in the system.
3C Initialize Mid POST chipset registers.
40 Detect different devices (such as parallel ports, serial ports, and coprocessor in CPU) successfully installed in the system and update the BDA, EBDA, and so on.
50 Program the memory hole or any kind of implementation that needs an adjustment in system RAM size if needed.
52 Update CMOS RAM memory size from the memory found in memory test. Allocate memory for the extended BIOS data area from base memory.
60 Initialize NumLock status and program the keyboard typematic rate.
75 Initialize Int-13 and prepare for IPL detection.
78 Initialize IPL devices controlled by BIOS and optional ROMs.
7A Initialize remaining optional ROMs. 1. Restart the ATCA-7150.
7C Generate and write contents of ESCD in NVRam.
84 Record errors encountered during POST. 1. Restart the ATCA-7150.
Checkpoint Description Solution


Table A-1 POST code checkpoints (continued)
85 Display errors to the user and get the user response for errors.
Handle the fault according to the prompts displayed on the terminal.
8C Initialize late POST chipset registers. 1. Restart the ATCA-7150.
8E Program peripheral parameters. Enable or disable NMI as selected.
90 Initialize late POST of system management terminal.
A1 Perform clean-up work needed before booting to the OS.
A2 Take care of runtime image preparation for different BIOS modules. Initialize the IRQ routing table. Prepare the runtime language module. Disable the system configuration display if needed.
A4 Prepare the runtime language module.
A7 Display the system configuration screen if enabled. Initialize the CPU's system configuration screen before booting, which includes the programming of the MTRR's.
A8 Prepare CPU for OS booting, including final MTRR values.
AC End POST initialization of chipset registers.
The device initialization manager (DIM) gets control at various time during BIOS POST to initialize different system buses.
Checkpoint Description Solution


Table A-2 lists the checkpoints where the DIM module is accessed and solutions.


Table A-2 DIM code checkpoints
2A Initialize different buses and perform the following functions:
z Reset, Detect, and Disable (function 0)
z Static Device Initialization (function 1)
z Boot Output Device Initialization (function 2)
Function 0 disables all device nodes, PCI devices, and PnP ISA cards. It also assigns PCI bus numbers.
Function 1 initializes all static devices that include manually configured onboard peripherals, memory and I/O decode windows in PCI-PCI bridges, and noncompliant PCI devices. Static resources are also reserved.
Function 2 searches for and initializes any PnP, PCI, or AGP video devices.
38 Initialize different buses and perform the following functions:
z Boot Input Device Initialization (function 3)
z IPL Device Initialization (function 4)
z General Device Initialization (function 5)
Function 3 searches for and configures PCI input devices and detects whether the system has the standard keyboard controller.
Function 4 searches for and configures all PnP and PCI boot devices.
Function 5 configures all onboard peripherals that are set to an automatic configuration and configures all remaining PnP and PCI devices.
Checkpoint Description Solution


ACPI checkpoints are displayed when an ACPI capable OS either enters or leaves a sleep state.
Table A-3 lists the types of checkpoints that may occur during ACPI sleep or wake states and solutions.
Table A-3 ACPI code checkpoints

AC First ASL check point. Indicate that the system is running in ACPI mode.
AA Indicate that the system is running in ACPI mode.
01, 02, 03, 04, 05 Enter sleep state S1, S2, S3, S4, or S5. 1. Restart the ATCA-7150.
10, 20, 30, 40, 50 Wake from sleep state S1, S2, S3, S4, or S5.


The Emerson Network Power - Embedded Computing publications listed below are referenced in this manual. You can obtain electronic copies of Emerson Network Power - Embedded Computing publications by contacting your local Emerson sales office. For documentation of final released (GA) products, you can also visit the following website: http://www.emersonnetworkpowerembeddedcomputing.com > Solution Services > Technical Documentation Search. This site provides the most up-to-date copies of Emerson Network Power - Embedded Computing product documentation.
Table B-1 Emerson Network Power - Embedded Computing Publications

For additional information, refer to the following table for related specifications. As an additional help, a source for the listed document is provided. Please note that, while these sources have been verified, the information is subject to change without notice.
Table B-2 Related Specifications



Table B-2 Related Specifications (continued)




Tempe, Arizona, USA 1 800 759 1107 1 602 438 5720
Munich, Germany +49 89 9608 0
For literature, training, and technical assistance and support programs, visit www.emersonnetworkpowerembeddedcomputing.com
Emerson Network Power. The global leader in enabling Business-Critical Continuity™
www.emersonnetworkpowerembeddedcomputing.com
AC Power Systems Connectivity DC Power Systems
Embedded Computing Embedded Power Integrated Cabinet Solutions
Outside Plant Power Switching & Control Precision Cooling
Services Site Monitoring Surge & Signal Protection
Emerson, Business-Critical Continuity, Emerson Network Power and the Emerson Network Power logo are trademarks and service marks of Emerson Electric Co. All other product or service names are the property of their respective owners. © 2008 Emerson Electric Co.
Besitzer und unser Team antworten in der Regel innerhalb eines Tages – und Ihre Frage hilft auch anderen weiter.
Stellen Sie die erste Frage — andere Nutzer oder unser Team antworten Ihnen.