Benutzeranleitung / Produktwartung 05 FOCUS SPOT 250R des Produzenten Elation Professional
Zur Seite of 48
Rev 10/28/05 FOCUS SPOT 250R Elation Professional 4295 Charter Street Los Angeles, Ca 90058 www.elationlighting.com.
Focus Spot 250R™ ©Elation Professional® 2 Focus Spot 250R™.
Focus Spot 250R™ ©Elation Professional® 3 Focus Spot 250R™ Contents 1. General Information……………………………………………………… 3 a. Introduction…………………………………………………………. 3 b. Unpacking……………………………………………………….
Focus Spot 250R™ ©Elation Professional® 4 Focus Spot 250R™ 1. General Information INTRODUCTION : Congratulations, you have just purchased one of the most innovative and reliable lighting fixtures on the market today! The Focus Spot 250R™, has been designed to perform reliably for years when the guidelines in this booklet are followed.
Focus Spot 250R™ ©Elation Professional® 5 Focus Spot 250R™ WARRANTY REGISTRATION : The Focus Spot 250R™ carries a two year (730 days) limited warranty.
Focus Spot 250R™ ©Elation Professional® 6 Focus Spot 250R™ Extreme caution should be used when operated this or any fixture fitted with a gas discharge lamp. Never open this fixture while in use! During the initial operation of this fixture, a light smoke or smell may emit from the interior of the fixture.
Focus Spot 250R™ ©Elation Professional® 7 Focus Spot 250R™ 2. Safety Instructions The Focus Spot 250™ is an extremely sophisticated piece of electronic equipment. To guarantee a smooth operation, it is important to follow the guidelines in this manual.
Focus Spot 250R™ ©Elation Professional® 8 Focus Spot 250R™ 11. Do not attempt to operate this fixture if the power cord has become damaged or frayed. Important Notice: Damages resulting from the disregard of safety and general user instructions found in this user manual are not subject to any warranty claims.
Focus Spot 250R™ ©Elation Professional® 9 Focus Spot 250R™ 3. Features • Pan 630° or 540˚ (User selectable) / Tilt 265° • 18° Beam Angle • 8 Dichroic color plus spot, for a total of 9 .
Focus Spot 250R™ ©Elation Professional® 10 Focus Spot 250R™ 4. GENERAL GUIDELINES This fixture is a professional lighting effect for designed for use on stage, in nightclubs, in theatres, etc. Do not attempt operation or installation without a proper knowledge on how to so.
Focus Spot 250R™ ©Elation Professional® 11 Focus Spot 250R™ 5. LAMP INSTALLATION INSTRUCTIONS Installing or replacing the lamp Only install the lamp with the device unplugged from the mains. The lamp has to be replaced when it is damaged or deformed.
Focus Spot 250R™ ©Elation Professional® 12 Focus Spot 250R™ Lamp Optimization The lamp orientation and optimization must be adjusted after every lamp change. This procedure centers the lamp in the reflector. Proper optimization will increase lamp life and ensure a bright crisp output.
Focus Spot 250R™ ©Elation Professional® 13 Focus Spot 250R™ 6. Mounting and Installation Mounting The FOCUS SPOT 250R™ is fully operational in three different mounting positions, hanging upside-down from a ceiling, side mounted, or set on a flat level surface (see illustration below).
Focus Spot 250R™ ©Elation Professional® 14 Focus Spot 250R™ installation. Never use the carrying handles for secondary attachment. a) Cam lock System: This system allows a quick and efficient means to secure a clamp to the unit. To secure a clamp to the unit, attach a clamp that is rated to handle the weight of the unit to your cam lock.
Focus Spot 250R™ ©Elation Professional® 15 Focus Spot 250R™ 7. Understanding DMX Data Cable (DMX Cable) Requirements (For DMX and Master/Slave Operation): Your fixture and your DMX controller require a standard 3-pin XLR connector for data input and data output (see figure below).
Focus Spot 250R™ ©Elation Professional® 16 Focus Spot 250R™ DMX-512 connection with DMX terminator When longer runs of cable are used, you may need to use a terminator on the last fixture to avoid erratic behavior.
Focus Spot 250R™ ©Elation Professional® 17 Focus Spot 250R™ Fixture DMX address; All fixtures should be given a DMX starting address when using a DMX signal, so the correct fixture responds to the correct control signal.
Focus Spot 250R™ ©Elation Professional® 18 Focus Spot 250R™ signal the display will flash "A.XXX" (XXX representing the actual DMX address).
Focus Spot 250R™ ©Elation Professional® 19 Focus Spot 250R™ 8. FIXTURE MENU On-Board System Menu: The FOCUS SPOT 250R™ comes with an easy to navigate system menu.
Focus Spot 250R™ ©Elation Professional® 20 Focus Spot 250R™ ALL Reset all motors and returns fixture to home SCAN Reset only motors for pan/tilt COLR Reset only motors for colors GOBO Reset only.
Focus Spot 250R™ ©Elation Professional® 21 Focus Spot 250R™ Main Menu Functions 1. ADDRESS MENU - AOO1 - A511 (Value) - This is where you set the fixtures DMX address. Setting/Changing the DMX Address After applying power to the FOCUS SPOT 250R™ the LED will display the fixture’s current DMX address immediately after the reset sequence.
Focus Spot 250R™ ©Elation Professional® 22 Focus Spot 250R™ channels. For example: If you press the up button until “ T-03 ” is displayed, the unit will test the color channel, changing the color one by one and show the rainbow effect with different speeds.
Focus Spot 250R™ ©Elation Professional® 23 Focus Spot 250R™ 5. Press Mode/Esc to return to the main menu. 4. LAMP MENU - ON/OFF Manually switches the lamp on and off. LAMP MENU - LAMP – This menu function will manually turn the lamp on and off.
Focus Spot 250R™ ©Elation Professional® 24 Focus Spot 250R™ mirror motor. 1. Access the main menu. 2. Tap the UP button until “ RESE ” is displayed, press ENTER. 3. Tap the UP button until “ SCAN ” is displayed, press ENTER to confirm. 4.
Focus Spot 250R™ ©Elation Professional® 25 Focus Spot 250R™ 6. TIME MENU - LIFE - Displays the fixtures total running time. LAMP - Displays the lamp running time. CLMP - Clears the lamp running time. TIME MAIN MENU LIFE - With this function you can display the total running time of the unit.
Focus Spot 250R™ ©Elation Professional® 26 Focus Spot 250R™ This menu setting reverses the Pan movements. RPAN MENU - RPAN – This menu function will reverse the mirror PAN movements. 1. Access the main menu. 2. Tap the UP button until “ RPAN ” is displayed, press ENTER.
Focus Spot 250R™ ©Elation Professional® 27 Focus Spot 250R™ 16bit mode the unit will have 11 DMX channels that includes two pan movement channels and two tilt movement channels. In 8bit mode the fixture will only have one pan and one tilt movement channel for a total of nine DMX channels.
Focus Spot 250R™ ©Elation Professional® 28 Focus Spot 250R™ 12. DISPLAY MENU - VALU (DMX-512 Value) - Display the DMX-512 value of each channel. D ON (Display On) – Turns the digital display on or off. FLIP - “ Flips ” the digital display 180 degrees.
Focus Spot 250R™ ©Elation Professional® 29 Focus Spot 250R™ 5. Press the UP button to select “ ON ” to activate this function, or “ OFF ” to deactivate this function. 6. Press ENTER to confirm. 7. Press MODE/ESC to return to the main menu.
Focus Spot 250R™ ©Elation Professional® 30 Focus Spot 250R™ 3. Tap the UP button until “RDMX ” is displayed, press ENTER. 4. The display will show “ON/OFF.” 5. Press the UP button to display “ON” to activate this function, or “OFF” to deactivate this function.
Focus Spot 250R™ ©Elation Professional® 31 Focus Spot 250R™ 2. Tap the UP button until “SPEC” is displayed, press ENTER. 3. Tap the UP button until “DLAY” is displayed, press ENTER. 4. The display will show “D-XX.” 5. Press the UP and DOWN buttons to adjust the delay time.
Focus Spot 250R™ ©Elation Professional® 32 Focus Spot 250R™ 2. Tap the UP button until “SPEC” is displayed, press ENTER. 3. Tap the UP button until “FEED ” is displayed, press ENTER. 4. The display will show “ON/OFF.” 5. Press the UP button to display “ON” to activate this function, or “OFF” to deactivate this function.
Focus Spot 250R™ ©Elation Professional® 33 Focus Spot 250R™ number of steps under Step (S-01- S-48). You can edit the individual scenes under Edit. 1. Access the main menu. 2. Tap the UP button until “ EDIT ” is displayed, press ENTER. 3. Tap the UP button until “ RUN ” is displayed, press ENTER.
Focus Spot 250R™ ©Elation Professional® 34 Focus Spot 250R™ 2. Tap the UP button until “EDIT” is displayed and press ENTER. 3. The display will show “ SC-01 ” , this stands for the scene number. For example, “SC-01” is displayed, it means you will be editing scene 1, press ENTER.
Focus Spot 250R™ ©Elation Professional® 35 Focus Spot 250R™ 3. Press [MODE/ESC], the display shows “SC01”. 4. Press [MODE/ESC], the display shows “C-01”. 5. Select " CEDT " by pressing [UP] or [DN]. 6. Press [MODE/ESC], the display shows "OFF".
Focus Spot 250R™ ©Elation Professional® 36 Focus Spot 250R™ 9. DMX Channel Traits: The chart below details the channel layout for 11 DMX channels (default). In 8bit mode the “Pan Fine” and “Tilt Fine” channels are not used, thus converting the fixture into a 9 channel DMX fixture.
Focus Spot 250R™ ©Elation Professional® 37 Focus Spot 250R™ DMX channel function and values: Channel 1 – PAN Coarse 8bit : Channel 2 – PAN Fine 16bit Channel 3 – TILT Coarse 8bit Channel 4.
Focus Spot 250R™ ©Elation Professional® 38 Focus Spot 250R™ Channel 8 - Shutter, Strobe: 0-31 Shutter Closed 32-63 Dimmer (close to open) 64-95 Strobe Effect (slow to fast) 96-127 No function (s.
Focus Spot 250R™ ©Elation Professional® 39 Focus Spot 250R™ 10. ERROR CODES: When power is applied, the unit will automatically enter a “reset/test” mode.
Focus Spot 250R™ ©Elation Professional® 40 Focus Spot 250R™ 05Er - Color-wheel error: The color wheel is not located in the default position after start-up or after a reset command.
Focus Spot 250R™ ©Elation Professional® 41 Focus Spot 250R™ 11. CLEANING AND MAINTENANCE The following points have to be considered during the inspection: 1. All screws for installing the devices or parts of the device have to be tightly connected and must not be corroded.
Focus Spot 250R™ ©Elation Professional® 42 Focus Spot 250R™ 12. 2-YEAR LIMITED WARRANTY A. Elation Professional ® hereby warrants, to the original purchaser, Elation Professional ® products to be free of manufacturing defects in material and workmanship for a period of two years, (730 days) from the date of purchase.
Focus Spot 250R™ ©Elation Professional® 43 Focus Spot 250R™ E. Elation Professional ® reserves the right to make changes in design and/or improvements upon its products without any obligation to include these changes in any products theretofore manufactured.
Focus Spot 250R™ ©Elation Professional® 44 Focus Spot 250R™ 13. TECHNICAL SPECIFICATIONS Power supply (user selectable) : _ 98VAC,50Hz; _ 120VAC,50Hz; _ 208 VAC,50Hz; _ 220VAC,50Hz; _ 230VAC,50Hz; _ 240VAC,50Hz; or _ 98VAC, 60Hz; _ 120VAC,60Hz; _ 208VAC,60Hz; _ 220VAC,60Hz; _ 230VAC,60Hz; _ 240VAC,60Hz; Power consumption : max.
Focus Spot 250R™ ©Elation Professional® 45 Focus Spot 250R™ Photometric Data: Gobos: Dimensional Drawings:.
Focus Spot 250R™ ©Elation Professional® 46 Focus Spot 250R™.
Focus Spot 250R™ ©Elation Professional® 47 Focus Spot 250R™.
Focus Spot 250R™ ©Elation Professional® 48 Focus Spot 250R™ Elation Professional 4295 Charter Street Los Angeles, CA. 90058 323-582-3322 / 323-582-3108 fax www.
Ein wichtiger Punkt beim Kauf des Geräts Elation Professional 05 FOCUS SPOT 250R (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Elation Professional 05 FOCUS SPOT 250R noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Elation Professional 05 FOCUS SPOT 250R - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Elation Professional 05 FOCUS SPOT 250R reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Elation Professional 05 FOCUS SPOT 250R erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Elation Professional 05 FOCUS SPOT 250R besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Elation Professional 05 FOCUS SPOT 250R verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Elation Professional 05 FOCUS SPOT 250R. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Elation Professional 05 FOCUS SPOT 250R gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.