Powerware 5130 Rack/Tower UPS 1250–3000 VA User’s Guide ®.
Requesting a Declaration of Conformity Units that are labeled with a CE mark comply with the following harmonized standa rds and EU directives: S Harmonized Standards: EN 62040 - 1 - 1 and EN 62040 - .
Class A EMC Statements (Low-Voltage Models) FCC Part 15 NOTE This equipment has been tested and found to comply with th e limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environm ent.
Special Symbols The following are examples of symbols used on the UPS or accessories to alert you to important information: RISK OF ELECTRIC SHOCK - Observe the warning associated with the risk of electric shock symbol.
EATON Powerware ® 5130 Rack/Tower UPS (1250–3000 VA) User’s Guide S 164201730 Rev 2 www.powerware.com i Table of Contents 1 Introduction 1 ......................................................... 2 Safety Warnings 3 .............................
TABLE OF CONTENTS EATON Powerware ® 5130 Rack/Tower UPS (1250–3000 VA) User’s Guide S 164201730 Rev 2 www.powerware.com ii Replacing Batteries 46 .................................................................... How to Replace Internal Batteries 47 .
EATON Powerware ® 5130 Rack/Tower UPS (1250–3000 VA) User’s Guide S 164201730 Rev 2 www.powerware.com 1 Chapter 1 Introduction Eaton’s Powerware ® 5130 uninterruptible power system (UPS) protects your sensitive electronic equipment from basic power problems such as power failures, power sags, power surges, brownouts, and line noise.
INTRODUCTION EATON Powerware ® 5130 Rack/Tower UPS (1250–3000 VA) User’s Guide S 164201730 Rev 2 www.powerware.com 2 Providing outstanding performance and reliability, the Powerware 5130’s unique benefits include: S Hours of extended runtime with up to four EBMs.
EATON Powerware ® 5130 Rack/Tower UPS (1250–3000 VA) User’s Guide S 164201730 Rev 2 www.powerware.com 3 Chapter 2 Safety Warnings IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS This manual contains important instructions t hat you should follow during installation and maintenance of the UPS and batteries.
SAFETY WARNINGS EATON Powerware ® 5130 Rack/Tower UPS (1250–3000 VA) User’s Guide S 164201730 Rev 2 www.powerware.com 4 CAUTION S Batteries can present a risk of electrical s hock or burn from high short-circuit current. Observe proper precautions.
SAFETY WARNINGS EATON Powerware ® 5130 Rack/Tower UPS (1250–3000 VA) User’s Guide S 164201730 Rev 2 www.powerware.com 5 ADVARSEL S Batterierne kan give risiko for elektri sk stød eller brandsår forårsaget af høj kortslutningsstrøm. Overhold gældende forsig tighedsregler.
SAFETY WARNINGS EATON Powerware ® 5130 Rack/Tower UPS (1250–3000 VA) User’s Guide S 164201730 Rev 2 www.powerware.com 6 S Teneinde de kans op brand of elektrische sc hok te verminderen dient deze UPS in een gebouw met temperatuur- en vochtigheidrege ling te worden geïnstalleerd, waar geen geleidende verontreinigingen aanwezig zijn.
SAFETY WARNINGS EATON Powerware ® 5130 Rack/Tower UPS (1250–3000 VA) User’s Guide S 164201730 Rev 2 www.powerware.com 7 Tarkeita Turvaohjeita TÄRKEITÄ TURVAOHJEITA - SUOMI SÄILYTÄ NÄMÄ OHJEET Tämä käyttöohje sisältää tärkeit ä ohjeita, joita on noudatettava UPS-virtalähteen ja akkujen asennuksen ja huollon yhteydessä.
SAFETY WARNINGS EATON Powerware ® 5130 Rack/Tower UPS (1250–3000 VA) User’s Guide S 164201730 Rev 2 www.powerware.com 8 Consignes de sécurité CONSIGNES DE SÉCURITÉ IMPORTANTES CONSERVER CES I.
SAFETY WARNINGS EATON Powerware ® 5130 Rack/Tower UPS (1250–3000 VA) User’s Guide S 164201730 Rev 2 www.powerware.com 9 ATTENTION! S Les batteries peuvent présenter un risque de choc électrique ou de brûlure provenant d’un courant de court-circuit haute intensit é.
SAFETY WARNINGS EATON Powerware ® 5130 Rack/Tower UPS (1250–3000 VA) User’s Guide S 164201730 Rev 2 www.powerware.com 10 S Um die Brand- oder Elektroschockgefahr zu verringern, diese USV nur in Gebäuden mit kontrollierter Temperatur und Luftfeuchtig keit installieren, in denen keine leitenden Schmutzstoffen vorhanden sind.
SAFETY WARNINGS EATON Powerware ® 5130 Rack/Tower UPS (1250–3000 VA) User’s Guide S 164201730 Rev 2 www.powerware.com 11 AVVERTENZA S L’UPS contiene la propria fonte di energia (ba tterie). Le prese d’uscita possono essere sotto tensione anche quando l’UPS non è coll egato all’alimentazione elettrica CA.
SAFETY WARNINGS EATON Powerware ® 5130 Rack/Tower UPS (1250–3000 VA) User’s Guide S 164201730 Rev 2 www.powerware.com 12 Viktig Sikkerhetsinformasion VIKTIGE SIKKERHETSINSTRUKSJONER GJEM DISSE INSTRUKSJONENE Denne håndboken inneholder viktige instruksjoner som du bør overholde ved montering og vedlikehold av UPS-enheten og batteriene.
SAFETY WARNINGS EATON Powerware ® 5130 Rack/Tower UPS (1250–3000 VA) User’s Guide S 164201730 Rev 2 www.powerware.com 13 FORSIKTIG S Batterier kan utgjøre en fare for elektrisk støt eller brannsår pga. høy kortsluttingsstrøm. Treff passende forholdsregler.
SAFETY WARNINGS EATON Powerware ® 5130 Rack/Tower UPS (1250–3000 VA) User’s Guide S 164201730 Rev 2 www.powerware.com 14 S Para reduzir o risco de incêndios ou choques elétricos, instale a UPS em ambiente interno com temperatura e umidade control adas e livres de contaminadores condutíveis.
SAFETY WARNINGS EATON Powerware ® 5130 Rack/Tower UPS (1250–3000 VA) User’s Guide S 164201730 Rev 2 www.powerware.com 15 ПРЕДУПРЕЖДЕНИЕ S В данном ИБП установлены собственны е источники энергии (батареи).
SAFETY WARNINGS EATON Powerware ® 5130 Rack/Tower UPS (1250–3000 VA) User’s Guide S 164201730 Rev 2 www.powerware.com 16 Advertencias de Seguridad INSTRUCCIONES DE SEGURIDAD IMPORTANTES GUARDE ES.
SAFETY WARNINGS EATON Powerware ® 5130 Rack/Tower UPS (1250–3000 VA) User’s Guide S 164201730 Rev 2 www.powerware.com 17 PRECAUCIÓN S Las baterías pueden constituir un ries go de descarga eléctrica o quemaduras por corriente alta de corto circuito.
SAFETY WARNINGS EATON Powerware ® 5130 Rack/Tower UPS (1250–3000 VA) User’s Guide S 164201730 Rev 2 www.powerware.com 18 S Minska risken för brand eller elektriska stötar genom att installera denna UPS-enhet inomhus, där temperatur och luftfukti ghet är kontrollerade och där inga ledande föroreningar förekommer.
EATON Powerware ® 5130 Rack/Tower UPS (1250–3000 VA) User’s Guide S 164201730 Rev 2 www.powerware.com 19 Chapter 3 Installation This section explains: S Equipment inspection S UPS internal batter.
INSTALLATION EATON Powerware ® 5130 Rack/Tower UPS (1250–3000 VA) User’s Guide S 164201730 Rev 2 www.powerware.com 20 Checking the Accessory Kit Verify that the following additional items are included with the UPS: Table 1.
INSTALLATION EATON Powerware ® 5130 Rack/Tower UPS (1250–3000 VA) User’s Guide S 164201730 Rev 2 www.powerware.com 21 The high - voltage models include the following additional items: Table 2. Additional High-Voltage Model Accessory Items Item Description Two cord-retention brackets Two equipment power cords 2500–3000 VA models only.
INSTALLATION EATON Powerware ® 5130 Rack/Tower UPS (1250–3000 VA) User’s Guide S 164201730 Rev 2 www.powerware.com 22 Connecting the UPS Internal Battery To ensure proper battery operation: 1. Verify that the UPS is off and unplugged. 2. Connect the internal battery connectors by firmly pressing the connectors together (see Figure 2).
INSTALLATION EATON Powerware ® 5130 Rack/Tower UPS (1250–3000 VA) User’s Guide S 164201730 Rev 2 www.powerware.com 23 UPS Setup The Powerware 5130 UPS is designed for flexible configurations and can be installed in a rack or as a standalone cabinet.
INSTALLATION EATON Powerware ® 5130 Rack/Tower UPS (1250–3000 VA) User’s Guide S 164201730 Rev 2 www.powerware.com 24 Installing the Rail Kit CAUTION The UPS and EBM are heavy (see page 52). A mini mum of two people are required to lift the cabinets into the rack.
INSTALLATION EATON Powerware ® 5130 Rack/Tower UPS (1250–3000 VA) User’s Guide S 164201730 Rev 2 www.powerware.com 25 6. Place the UPS on a flat, stable surface with the front of the UPS facing you. 7. Attach the supplied mounting brackets to the cabinet and secure with four M4 screws on each side (see Figure 4).
INSTALLATION EATON Powerware ® 5130 Rack/Tower UPS (1250–3000 VA) User’s Guide S 164201730 Rev 2 www.powerware.com 26 2. For one 2U cabinet, the pedestals must be installed. Continue to Step 3. For one 3U cabinet, continue to “Installing the UPS” on page 28.
INSTALLATION EATON Powerware ® 5130 Rack/Tower UPS (1250–3000 VA) User’s Guide S 164201730 Rev 2 www.powerware.com 27 5. Align each joining bracket with the adjacent cabinet screw holes and secure with the supplied screws (see Figure 7). NOTE Joining brackets are required for inst allations with two or more cabinets.
INSTALLATION EATON Powerware ® 5130 Rack/Tower UPS (1250–3000 VA) User’s Guide S 164201730 Rev 2 www.powerware.com 28 Installing the UPS NOTE Do not make unauthorized changes to the UPS or accessories; otherwise, damage may occur to your equipment and void your warranty.
INSTALLATION EATON Powerware ® 5130 Rack/Tower UPS (1250–3000 VA) User’s Guide S 164201730 Rev 2 www.powerware.com 29 3. If you plan to install power management software, connect your computer to the USB port or RS - 232 communication port using the supplied communication cable.
INSTALLATION EATON Powerware ® 5130 Rack/Tower UPS (1250–3000 VA) User’s Guide S 164201730 Rev 2 www.powerware.com 30 5. Plug the equipment to be protected into the appropriate UPS output receptacles (see page 42 for more information on load segments).
INSTALLATION EATON Powerware ® 5130 Rack/Tower UPS (1250–3000 VA) User’s Guide S 164201730 Rev 2 www.powerware.com 31 RPO and ROO Installation The Powerware 5130 includes a two - position termina.
INSTALLATION EATON Powerware ® 5130 Rack/Tower UPS (1250–3000 VA) User’s Guide S 164201730 Rev 2 www.powerware.com 32 WARNING The RPO/ROO circuit is an IEC 60950 safety extra lo w voltage (SELV) circuit. This circuit must be separated from any hazardous voltage ci rcuits by reinforced insulation.
INSTALLATION EATON Powerware ® 5130 Rack/Tower UPS (1250–3000 VA) User’s Guide S 164201730 Rev 2 www.powerware.com 33 UPS Rear Panels This section shows the rear panels of the Powerware 5130 models.
INSTALLATION EATON Powerware ® 5130 Rack/Tower UPS (1250–3000 VA) User’s Guide S 164201730 Rev 2 www.powerware.com 34 USB Port RS-232 Port EBM Battery Connector Power Cord (20A, L6-20 plug) RPO/ROO Connector (1) L6-30 Receptacle Communication Bay Ground Bonding Screw EBM RJ-11 Connector (2) L6-20 Receptacles Figure 14.
EATON Powerware ® 5130 Rack/Tower UPS (1250–3000 VA) User’s Guide S 164201730 Rev 2 www.powerware.com 35 Chapter 4 Operation This section describes: S Turning the UPS on and off S Starting the UPS on battery S Initiating the self - test S Operating modes Turning the UPS On To turn the UPS on: 1.
OPERATION EATON Powerware ® 5130 Rack/Tower UPS (1250–3000 VA) User’s Guide S 164201730 Rev 2 www.powerware.com 36 Starting the UPS on Battery NOTE Before using this feature, the UPS must have been powered by utility power at least once. To turn on the UPS without using utility power, press and hold the button for two seconds.
OPERATION EATON Powerware ® 5130 Rack/Tower UPS (1250–3000 VA) User’s Guide S 164201730 Rev 2 www.powerware.com 37 Operating Modes The Powerware 5130 front panel indicates the UPS status through the UPS indicators. Figure 17 shows the UPS front panel indicators and controls.
OPERATION EATON Powerware ® 5130 Rack/Tower UPS (1250–3000 VA) User’s Guide S 164201730 Rev 2 www.powerware.com 38 Battery Mode When the UPS is operating during a power outage, the alarm beeps once every 10 seconds and the button, the μ ,a n d indicators are on.
EATON Powerware ® 5130 Rack/Tower UPS (1250–3000 VA) User’s Guide S 164201730 Rev 2 www.powerware.com 39 Chapter 5 Additional UPS Features This section describes: S USB port S RS - 232 communicat.
ADDITIONAL UPS FEATURES EATON Powerware ® 5130 Rack/Tower UPS (1250–3000 VA) User’s Guide S 164201730 Rev 2 www.powerware.com 40 Figure 20. The USB Port 2. Install the Powerware LanSafe Power Management Software and USB drivers according to the instructions provided at www.
ADDITIONAL UPS FEATURES EATON Powerware ® 5130 Rack/Tower UPS (1250–3000 VA) User’s Guide S 164201730 Rev 2 www.powerware.com 41 Contact Communication Port (optional) When a signal is activated, the contact is closed between the common (Pin 4) and the pin for the corresponding signal.
ADDITIONAL UPS FEATURES EATON Powerware ® 5130 Rack/Tower UPS (1250–3000 VA) User’s Guide S 164201730 Rev 2 www.powerware.com 42 Load Segments (PowerShare) Each UPS has programmable outlets as shown in Figure 22 through Figure 24. During a power outage, you can keep key pieces of equipment running while you turn off other equipment.
ADDITIONAL UPS FEATURES EATON Powerware ® 5130 Rack/Tower UPS (1250–3000 VA) User’s Guide S 164201730 Rev 2 www.powerware.com 43 Customizing the UPS with the UPS Configuration Tool To customize the UPS settings: 1. Download the UPS Configuration tool from www.
ADDITIONAL UPS FEATURES EATON Powerware ® 5130 Rack/Tower UPS (1250–3000 VA) User’s Guide S 164201730 Rev 2 www.powerware.com 44 Table 6. Voltage Threshold Options (continued) PW5130G3000-XL2U Fu.
EATON Powerware ® 5130 Rack/Tower UPS (1250–3000 VA) User’s Guide S 164201730 Rev 2 www.powerware.com 45 Chapter 6 UPS Maintenance This section explains how to: S Care for the UPS and batteries S.
UPS MAINTENANCE EATON Powerware ® 5130 Rack/Tower UPS (1250–3000 VA) User’s Guide S 164201730 Rev 2 www.powerware.com 46 Storing the UPS and Batteries If you store the UPS for a long period, recharge the battery every 6 months by plugging the UPS into a power outlet.
UPS MAINTENANCE EATON Powerware ® 5130 Rack/Tower UPS (1250–3000 VA) User’s Guide S 164201730 Rev 2 www.powerware.com 47 How to Replace Internal Batteries CAUTION S Pull the battery out onto a flat, stable surface. The battery is unsupported when you pull it out of the UPS.
UPS MAINTENANCE EATON Powerware ® 5130 Rack/Tower UPS (1250–3000 VA) User’s Guide S 164201730 Rev 2 www.powerware.com 48 3. Unscrew and remove the metal battery cover (see Figure 27). 1 2 Figure 27. Removing the Battery Cover 4. Pull the battery block out onto a flat, stable surface (see Figure 28).
UPS MAINTENANCE EATON Powerware ® 5130 Rack/Tower UPS (1250–3000 VA) User’s Guide S 164201730 Rev 2 www.powerware.com 49 How to Replace Extended Battery Modules To replace the Extended Battery Modules (EBMs): 1. Unplug the EBM cable from the UPS.
UPS MAINTENANCE EATON Powerware ® 5130 Rack/Tower UPS (1250–3000 VA) User’s Guide S 164201730 Rev 2 www.powerware.com 50 4. Replace the EBM. See “Recycling the Used Battery or UPS” on page 50 for proper disposal. 5. For tower models only. Install the joining bracket between cabinets.
EATON Powerware ® 5130 Rack/Tower UPS (1250–3000 VA) User’s Guide S 164201730 Rev 2 www.powerware.com 51 Chapter 7 Specifications Filter Transformer “AVR” Charger Inverter Battery Figure 30.
SPECIFICATIONS EATON Powerware ® 5130 Rack/Tower UPS (1250–3000 VA) User’s Guide S 164201730 Rev 2 www.powerware.com 52 Table 11. High-Voltage Model Specifications Model Number Power Levels (Rate.
SPECIFICATIONS EATON Powerware ® 5130 Rack/Tower UPS (1250–3000 VA) User’s Guide S 164201730 Rev 2 www.powerware.com 53 Table 12. Weights and Dimensions (continued) EBM Model Number Dimensions (WxHxD) Weight PW5130N1750-EBM2U 440 × 86 × 509 mm 17.
SPECIFICATIONS EATON Powerware ® 5130 Rack/Tower UPS (1250–3000 VA) User’s Guide S 164201730 Rev 2 www.powerware.com 54 Table 14. Environmental and Safety Low Voltage Models High Voltage Models O.
SPECIFICATIONS EATON Powerware ® 5130 Rack/Tower UPS (1250–3000 VA) User’s Guide S 164201730 Rev 2 www.powerware.com 55 Table 16. Battery Runtimes Half Load UPS Internal Batteries +1 EBM +2 EBMs .
SPECIFICATIONS EATON Powerware ® 5130 Rack/Tower UPS (1250–3000 VA) User’s Guide S 164201730 Rev 2 www.powerware.com 56.
EATON Powerware ® 5130 Rack/Tower UPS (1250–3000 VA) User’s Guide S 164201730 Rev 2 www.powerware.com 57 Chapter 8 Troubleshooting This section explains: S UPS alarms and conditions S Service and support Audible Alarms and UPS Conditions The UPS has an audible alarm feature to alert you of potential power problems.
TROUBLESHOOTING EATON Powerware ® 5130 Rack/Tower UPS (1250–3000 VA) User’s Guide S 164201730 Rev 2 www.powerware.com 58 Table 17. Troubleshooting Guide Alarm or Condition Possible Cause Action When starting the UPS with the button, all the indicators turn on once, the alarm beeps once, and then indicator remains on.
TROUBLESHOOTING EATON Powerware ® 5130 Rack/Tower UPS (1250–3000 VA) User’s Guide S 164201730 Rev 2 www.powerware.com 59 Service and Support If you have any questions or problems with the UPS, call your Local Distributor or the Help Desk at one of the following telephone numbers and ask for a UPS technical representative.
TROUBLESHOOTING EATON Powerware ® 5130 Rack/Tower UPS (1250–3000 VA) User’s Guide S 164201730 Rev 2 www.powerware.com 60.
EATON Powerware ® 5130 Rack/Tower UPS (1250–3000 VA) User’s Guide S 164201730 Rev 2 www.powerware.com 61 Chapter 9 Warranty Two-Year Limited Warranty (US and Canada) Powerware UPS Models: 5110, 5115, 5125, and 5130 WARRANTOR: The warrantor for the limited warranties set forth herein is Eaton Electrical, Inc.
WARRANTY EATON Powerware ® 5130 Rack/Tower UPS (1250–3000 VA) User’s Guide S 164201730 Rev 2 www.powerware.com 62 WHAT THIS LIMITED WARRANTY DOES NOT COVER: This Warranty does not cover any defec.
WARRANTY EATON Powerware ® 5130 Rack/Tower UPS (1250–3000 VA) User’s Guide S 164201730 Rev 2 www.powerware.com 63 COSTS NOT RELATED TO WARRANTY: The End-User shall be invoiced for , and shall pay.
WARRANTY EATON Powerware ® 5130 Rack/Tower UPS (1250–3000 VA) User’s Guide S 164201730 Rev 2 www.powerware.com 64 WHAT THIS LIMITED WARRANTY DOES NOT COVER: This Warranty does not cover any defec.
WARRANTY EATON Powerware ® 5130 Rack/Tower UPS (1250–3000 VA) User’s Guide S 164201730 Rev 2 www.powerware.com 65 OTHER LIMITATIONS: Company’s obligations under this Warranty are expressly conditioned upon receipt by Company of all payments due to it (including interest charges, if any).
WARRANTY EATON Powerware ® 5130 Rack/Tower UPS (1250–3000 VA) User’s Guide S 164201730 Rev 2 www.powerware.com 66 WHAT THIS GUARANTY DOES NOT COVER: Any reimbursement or repair to End -User’s equipment does not include reimbursement for or restoration of any data l oss.
.
MAU - 00070 AC *1642017302* 164201730 2.
Ein wichtiger Punkt beim Kauf des Geräts Eaton Powerware 5130 Rack/Tower UPS 1250-3000 VA (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Eaton Powerware 5130 Rack/Tower UPS 1250-3000 VA noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Eaton Powerware 5130 Rack/Tower UPS 1250-3000 VA - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Eaton Powerware 5130 Rack/Tower UPS 1250-3000 VA reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Eaton Powerware 5130 Rack/Tower UPS 1250-3000 VA erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Eaton Powerware 5130 Rack/Tower UPS 1250-3000 VA besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Eaton Powerware 5130 Rack/Tower UPS 1250-3000 VA verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Eaton Powerware 5130 Rack/Tower UPS 1250-3000 VA. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Eaton Powerware 5130 Rack/Tower UPS 1250-3000 VA gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.