Benutzeranleitung / Produktwartung QSNAP des Produzenten Eaton Electrical
Zur Seite of 30
Publication No. MN05001001E February 2002 New Intelligent T echnologies QCPort Starter Network Adapter Product (QSNAP) Installation and User Manual.
Intelligent Technologies ( IT. ) QSNAP Pub. No. MN05001001E February 2002 Important Notice – Please Read The product discussed in this literature is subject to terms and conditions outlined in appropriate Eaton’ s Cutler -Hammer selling policies.
Intelligent Technologies ( IT. ) QSNAP Pub. No. MN05001001E i February 2002 T able of Contents PRODUCT OVERVIEW Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Features and Benefits .
Intelligent Technologies ( IT. ) QSNAP ii Pub. No. MN05001001E February 2002 List of Figures Figure 1: QSNAP Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Figure 2: QSNAP Dimensions, mm [in] . . .
Intelligent Technologies ( IT. ) QSNAP Pub. No. MN05001001E 1 February 2002 Product Overview Description Cutler -Hammer Intelligent T echnologies ( IT . ) QSNAP (QCPort Starter Network Adapter Product) by Eaton Corporation is the result of a substantive engineering and marketing effort, involving extensive customer input.
Intelligent Technologies ( IT. ) QSNAP 2 Pub. No. MN05001001E February 2002 Features and Benefits The IT . QSNAP includes the following significant features: ● Communication to QCPort consuming a single QCPort ID ● Control of non-reversing and reversing Eaton’ s Cutler -Hammer Intelligent T echnologies ( IT .
Intelligent Technologies ( IT. ) QSNAP Pub. No. MN05001001E 3 February 2002 Safety The following safety statements relate to the installation, setup and operation of Eaton’ s Cutler -Hammer IT .
Intelligent Technologies ( IT. ) QSNAP 4 Pub. No. MN05001001E February 2002 Environmental Ratings The following environmental ratings apply to the QSNAP . T able 3: Environmental Ratings Approvals/Certifications The following approvals and certifications apply to the QSNAP .
Intelligent Technologies ( IT. ) QSNAP Pub. No. MN05001001E 5 February 2002 Physical Features Physical Description Figure 1 illustrates the front and back of the IT . QSNAP and its various features. Figure 1: QSNAP Features Dimensions Figure 2 illustrates the dimensions of the IT .
Intelligent Technologies ( IT. ) QSNAP 6 Pub. No. MN05001001E February 2002 Power Source The IT . QSNAP is designed for use with 24V DC power . The QSNAP uses power from two sources when operating properly; these sources are the QCPort subnet and the Eaton ’ s Cutler -Hammer Intelligent T echnologies ( IT .
Intelligent Technologies ( IT. ) QSNAP Pub. No. MN05001001E 7 February 2002 CAUTION Only apply 24V DC to the QSNAP . Use of any other voltage may result in personal injury , property damage and damage to the QSNAP .
Intelligent Technologies ( IT. ) QSNAP 8 Pub. No. MN05001001E February 2002 Operation This section provides details about the following features and aspects of QSNAP operation: ● “ Out of box ” .
Intelligent Technologies ( IT. ) QSNAP Pub. No. MN05001001E 9 February 2002 T ypical Application The following fi gure illustrates a typical QSNAP application, where a single QSNAP is connected to one motor controller and where the motor controllers are distributed throughout QCPort.
Intelligent Technologies ( IT. ) QSNAP 10 Pub. No. MN05001001E February 2002 Enhanced Features The QSNAP offers a variety of enhanced features, including: settable warnings, current threshold warning, underload warning and reset. T o help diagnose an application, a fault queue is provided to view the last fi ve faults.
Intelligent Technologies ( IT. ) QSNAP Pub. No. MN05001001E 11 February 2002 Input/Output Data The QSNAP offers a standard data list (shown below) for default operation. The list is con fi gurable with data contained within T able 21 in Appendix A: QSNAP Parameters , using the CH Studio application.
Intelligent Technologies ( IT. ) QSNAP 12 Pub. No. MN05001001E February 2002 T able 11: Default Input Data Output Data Use T ables 12 and 13 when setting up the QSNAP output data.
Intelligent Technologies ( IT. ) QSNAP Pub. No. MN05001001E 13 February 2002 Status LED The status LED is located on the lower right of the QSNAP as pictured in Figure 1: QSNAP Features . The LED ’ s status changes depending on the state of the QSNAP .
Intelligent Technologies ( IT. ) QSNAP 14 Pub. No. MN05001001E February 2002 Configuration The only con fi guration that is necessary for normal operation of the QSNAP is setting the Group ID and SW1 positions A and B, as described in the “ Installation ” section.
Intelligent Technologies ( IT. ) QSNAP Pub. No. MN05001001E 15 February 2002 Installation Set the Group ID The Group ID refers to the logical QCPort group to which the QSNAP belongs. For further information on the explanation of Group ID and the system con fi guration, see the IT .
Intelligent Technologies ( IT. ) QSNAP 16 Pub. No. MN05001001E February 2002 SW1 Settings SW1 is used to set the existence of the second Aux contact and the external ground fault. T able 16: SW1 Settings Mount the IT . QSNAP to the Starter The IT . QSNAP is designed to be installed in the auxiliary contact locations of the IT .
Intelligent Technologies ( IT. ) QSNAP Pub. No. MN05001001E 17 February 2002 Use the following steps and the illustration in Figure 7 to mount the QSNAP . 1. Align both the QSNAP feet with the auxiliary contact mounting slots on the starter , as illustrated in the fi gure.
Intelligent Technologies ( IT. ) QSNAP 18 Pub. No. MN05001001E February 2002 Wire the IT . QSNAP to the Starter The QSNAP is connected to the IT . starter using a factory-provided jumper with an RJ-45 plug on one end and a pigtail on the other . The pigtail is color coded to facilitate accurate connection to the overload terminal block.
Intelligent Technologies ( IT. ) QSNAP Pub. No. MN05001001E 19 February 2002 2. T o lock the starter interface to the overload, rotate the orange locking tabs until the tab is locked into the slots in the overload. Use Figure 11 for information on which way to rotate the locking tabs.
Intelligent Technologies ( IT. ) QSNAP 20 Pub. No. MN05001001E February 2002 T roubleshooting and Maintenance Renewal Parts The renewal parts for the QSNAP are shown in the following table.
Intelligent Technologies ( IT. ) QSNAP Pub. No. MN05001001E 21 February 2002 Appendix A: QSNAP Parameters Refer to the following table when con fi guring the QSNAP .
Intelligent Technologies ( IT. ) QSNAP 22 Pub. No. MN05001001E February 2002 T able 22: Data Parameters Number Parameter Units Length 11 Motor Control 1 12 Motor Control Status 1 13 Motor Control Faul.
Intelligent Technologies ( IT. ) QSNAP Pub. No. MN05001001E 23 February 2002 Intelligent T echnologies ( IT . ) Publications and Support T able 23: IT . Publications For copies of these and other publications contact the Literature Ful fi llment Center at 1-800-957-7050.
Intelligent Technologies ( IT. ) QSNAP 24 Pub. No. MN05001001E February 2002.
.
© 2002 Eaton Corporation All Rights Reserved Publication No. MN05001001E February 2002 Printed in USA Eaton Corporation Cutler -Hammer business unit 1000 Cherrington Parkway Moon T ownship, P A 15108-4312 USA tel: 1-800-525-2000 www .cutler-hammer .eaton.
Ein wichtiger Punkt beim Kauf des Geräts Eaton Electrical QSNAP (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Eaton Electrical QSNAP noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Eaton Electrical QSNAP - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Eaton Electrical QSNAP reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Eaton Electrical QSNAP erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Eaton Electrical QSNAP besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Eaton Electrical QSNAP verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Eaton Electrical QSNAP. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Eaton Electrical QSNAP gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.