Benutzeranleitung / Produktwartung BF33ST/DX des Produzenten Dimplex
Zur Seite of 24
INSTALLATION GUIDE FOR THE ELECTRIC FIREPLACE MODEL NUMBERS: BF33ST/DX BF39ST/DX BF45ST/DX 7206350200REV06.
CONTENTS PAGE 1 Listings and Code Approvals PAGE 1 Model Specifications PAGE 1 Step-by-Step Installation Section A P A G E 2 F r a m i n g Section B PAGE 2 Recommended Power Supply Wire Specifications.
LISTINGS AND CODE APPROVALS The BF series fireplaces have been tested in acco rdance with the UL 2021 and CSA C22.2 No. 46 standards for fixed and location-dedicated ele ctric ro om heaters.
WARNING Ensure method of installation does NOT obscure the air intake slots on bottom front of unit in any manner. (see diagram in Section A) SECTION A: FRAMING Dimensions This firepl ace is a zer o clear ance des ign. No comb ustibl es can be placed on the top surface of the fireplace.
VOLTAGE SELECTOR SWITCH LOCATION IMPORTANT: Ensure that the incoming power supply voltage matches the setting of the voltage selector switch. NOTE: The voltage selector switch is located inside the exhaust panel on the top right hand corner.
SECTION C: FACTORY SETTING WIRING (WITHOUT MAIN POWER WALL SWITCH) IMPORTANT: The unit is factory confi gured for 208/240 volt operation NOTE: Use 3 conductor wire with ground (4 wires total) from the power supply (breaker panel) to the junction box on the unit.
SECTION C: FACTORY SETTING WIRING (WITHOUT MAIN PO WER WALL SWITCH) IMPORTANT: The unit is factory confi gured for 208/240 volt operation NOTE: Use 2 conductor wire with ground (3 wires total) from the power supply (breaker panel) to the junction box on the unit.
SECTION C: FACTORY SETTING WIRING (WITHOUT MAIN PO WER WALL SWITCH) (NO HEAT INSTALLATION) IMPORTANT: The unit is factory confi gured for 208/240 volt operation NOTE: Use 2 conductor wire with ground (3 wires total) from the power supply (breaker panel) to the junction box on the unit.
SECTION D: MAIN POWER WALL SWITCH WIRING OPTI ONS MAIN POWER WALL SWITCH WIRING FOR 240 VOLT NOTE: This option should not be used with the remote control kit. NOTE: Before installing the unit you must have the following wires installed: 1. A 3 conductor wire with ground (4 wires to tal) from the power supply panel to the main switch wall box.
240 VOLT MAIN WALL SWITCH WIRING DIAGRAM 8 FIREPLACE JUNCTION BO X 240 V POWER SUPPLY (BREAKER PANEL) WHITE - N RED – L2 BLACK – L1 WHITE – N BLACK – L1 GROUND - G WALL SWITCH RED – L2 GROUN.
MAIN POWER WALL SWITCH WIRING FOR 120 VOLT NOTE: This option should not be used with the remote control kit. NOTE: Before installing the unit have the following wires installed: 1. A 2 conductor wire with ground (3 wires tota l) from the power supply panel to the main switch wall box.
120 VOLT MAIN WALL SWITCH WIRING DIAGRAM 10 FIREPLACE JUNCTION BO X 120 V POWER SUPPLY (BREAKER PANEL) WHITE - N RED – L2 BLACK – L1 WHITE – N BLACK – L1 GROUND - G WALL SWITCH GROUND - G.
MAIN POWER WALL SWITCH WIRING FOR 120 VOLT NO HEAT INSTALLATION NOTE: This option should not be used with the remote control kit. NOTE: Before installing the unit have the following wires installed: 3. A 2 conductor wire with ground (3 wires total) from the power supply panel to the main switch wall box.
120 VOLT MAIN WALL SWITCH WIRING DIAGRAM NO HEAT INSTALLATION FIREPLACE JUNCTION BO X 120 V POWER SUPPLY (BREAKER PANEL) WHITE - N RED – L2 BLACK – L1 WHITE – N BLACK – L1 GROUND - G WALL SWIT.
SECTION E: HEATER WALL SWITCH AND WALL THERMOSTAT WIRING OPTIONS HEATER WALL SWITCH WIRING FOR 120/240 VOLT NOTE: Before installing the unit complete the following: 1. Install main power connection with appr opriate voltage as per Section C or Section D.
HEATER WALL SWITCH WIRING DIAGRAM FOR 120/240 VOLT (SEE SECTION C OR SECTION D FOR MAIN POWER CONNECTION) 14 FIREPLACE JUNCTION BOX RED – 2 WALL SWITCH RED – 1 GROUND - G.
WALL MOUNTED THERMOSTAT WIRING FOR 120/240 VOLT NOTE: Before installing the unit complete the following: 1. Install main power connection with appr opriate voltage as per Section C or Section D. 2. Install a 2 conductor wire with ground (3 wires total) from the thermo stat wall box to the junction box on the unit.
WALL MOUNTED THERMOSTAT WIRING DIAGRAM FOR 120/240 VOLT (SEE SECTION C OR SECTION D FOR MAIN POWER CONNECTION) 16 FIREPLACE JUNCTION BOX WALL THERMOSTAT RED – 1 GROUND - G RED – 2 CONNECT GROUND T.
FLAME OVERRIDE SWITCH WIRI NG FOR 120/240 VOLT NOT AVAILABLE WITH NO HEAT INSTALLATION NOTE: The fireplace can be wired to have a wall switch operate the heater indepen dent of the flame . NOTE: Before installing the unit complete the following: 1. Install main power connection with appr opriate voltage as per Section C or Section D.
FLAME OVERRIDE WALL SWITCH WIRING DIAGRAM FOR 120/240 VOLT (SEE SECTION C OR SECTION D FOR MAIN POWER C0NNECTION) NOT AVAILABLE WITH NO HEAT INSTALLATION FIREPLACE JUNCTION BOX BLUE – 4 WALL SWITCH .
WIRING DIAGRAM LOWER SECTION 19 BLACK WHITE BROWN CITOR BYPASS HARNESS LOWER HARNESS WHITE ORANGE FROM TOP BROWN FROM TOP RED FROM TOP BLUE (3) MOTOR FLICKER TWIST-TIE RED RED 2 1 RED (L2) HEATER SWIT.
WIRING DIAGRAM UPPER SECTION 20 CUT-OUT M ELEMENT #2 ELEMENT #1 2 6 4 1 5 3 BLOW ER WH EEL BLW. MOTOR BROWN ORANGE RED (CUT-OUT LONG WIRE) BLK YLW BLK BLK YLW BLK BLK BLK YLW RED (CUT-OUT SHORT WIRE).
WIRING SCHEMATIC 21.
1367 Industrial Road Cambridge, Ontario Canada, N1R 7G8 1-888-DIMPLEX 1-888-346-7539 Approved for use in the United States an d Can ada.
Ein wichtiger Punkt beim Kauf des Geräts Dimplex BF33ST/DX (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Dimplex BF33ST/DX noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Dimplex BF33ST/DX - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Dimplex BF33ST/DX reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Dimplex BF33ST/DX erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Dimplex BF33ST/DX besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Dimplex BF33ST/DX verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Dimplex BF33ST/DX. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Dimplex BF33ST/DX gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.