MGP-4600 6/13/95 DeVilbiss Air Power Company • 213 Industrial Drive • Jackson, TN 38301-9615 OWNERS MANUAL FOR DeVILBISS GENERA TOR Model No. GBV4600 GBV4600 9 4600/5750 120/240 38.3A/19.2A SINGLE 60 Hz 3600 RPM 104° F 6 GALLON 13.3/6.5 HR MODEL HORSE POWER RA TED/SURGE WA TTS VOL T AGE AMPERAGE PHASE HERTZ ENGINE SPEED MAX.
2 T ABLE OF CONTENTS In the unlikely event you should have a problem with this product or if you are missing any parts, it is not necessary to return it to the store where you purchased it. Simply call our toll-free number and talk with our Service Representative.
3 LIMITED WARRANTY ONE YEAR FROM DA TE OF PURCHASE All merchandise manufactured by DeVilbiss Air Power Company is warranted to be free of defects in workmanship and material which occur during the first year from the date of purchase by the original purchaser (initial user).
4 SAFETY GUIDELINES - DEFINITIONS URGENT SAFETY INFORMATION - A HAZARD THAT WILL CAUSE SERIOUS INJURY OR LOSS OF LIFE Information that you should pay special attention to. Information for preventing damage to equipment. This manual contains information that is important for you to know and understand.
5 READ AND UNDERST AND ALL WARNINGS BEFORE A TTEMPTING TO OPERA TE GENERA TOR. Operation of generator in rain, wet, icy , or flooded conditons. Use of worn damaged, undersized or un- grounded extension cords. Placing generator on or against highly conductive surface, such as a steel walkway or metal roof.
6 READ AND UNDERST AND ALL WARNINGS BEFORE A TTEMPTING TO OPERA TE GENERA TOR. T urn engine of f and allow it to cool before adding fuel to the tank. Equip area of operation with a fire extin- guisher certified to handle gasoline or fuel fires. Add fuel to tank in well ventilated area.
7 READ AND UNDERST AND ALL WARNINGS BEFORE A TTEMPTING TO OPERA TE GENERA TOR. RISK OF BREA THING - INHALA TION HAZARD Operate generator in clean, dry , well ventilated area. Avoid enclosed ar- eas like garages, basements, stor- age sheds, etc., which lack a steady exchange of air .
8 READ AND UNDERST AND ALL WARNINGS BEFORE A TTEMPTING TO OPERA TE GENERA TOR. During operation, touch only the con- trol surfaces of the generator . Keep children away from the generator at all times. They may not be able to recognize the hazards of this prod- uct.
9 W A TT AGE CALCULA TING INSTRUCTIONS Never exceed the rated capacity of your generator . Serious damage to the generator or appliance could result from an overload. 1. Starting and running wattage requirements should always be calculated when matching a generators wattage capacity to the appliance or tool.
10 W A TT AGE CALCULA TING INSTRUCTIONS (cont'd) ST AR TING W A TT AGE REQUIREMENTS 1. Some appliances and tools will list on the motor name plate the starting and running voltage and amperage requirements.
11 GENERAL P AR TS IDENTIFICA TION 1. Frame assembly- Protects generator and engine as well as a means to handle complete unit. 2. Fuel T ank- Six (6) gallon capacity . 3. Fuel Cap- Remove to check/add fuel. 4. Cover Panel- Contains wiring for receptacles, circuit breakers, and control switches.
12 GROUNDING INSTRUCTIONS/EXTENSION CORDS Extension Cord Wire Gauge Chart Grounding Lug Amperage *Up to 20 amp draw Up to 30 amp draw Cord Length 0 to 100 ft. 0 to 100 ft. Wire Gauge Size 12 ga. 10 ga. GROUNDING INSTRUCTION This generator should be grounded to help prevent accidental electrical shock.
13 EVERY 5 HOURS OR DAIL Y X 100 HOURS OR EVER Y SEASON MAINTENANCE OPERA TION Check Oil Level Change Oil * Change Air Filter Change Fuel Filter Replace or Clean Spark Plug Clean exterior of generator 50 HOURS OR EVER Y SEASON X X X NOTE 1 X NOTE 2 25 HOURS OR EVER Y SEASON X NOTE 3 *Change oil after first 5 hours then after every 50 hours.
14 PROBLEM CAUSE C ORRECTION Engine will not start 1. Low on fuel or oil. 2. Ignition switch in "Off" position. 3. Faulty spark plug. 4. Choke in wrong position. 5. Fuel shut-of f valve in closed position. 6. Unit loaded during start-up. 7. Spark plug wire loose.
15 1. Place battery in rack with terminals facing towards generator head. 2. Place battery bracket (A) over battery as shown (opposite battery terminals).
OWNERS MANUAL FOR DeVILBISS GENERA TOR MODEL NO. GBV4600 W ARRANTY This product is covered by the DeVilbiss one year limited warranty (SP-100-E). The warranty can be found on page 3 or is available upon request. Attach Sales Receipt Here. Retain Original Sales Receipt as Proof of Purchase for W arranty Repair W ork.
Ein wichtiger Punkt beim Kauf des Geräts DeVillbiss Air Power Company MGP-4600 (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie DeVillbiss Air Power Company MGP-4600 noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für DeVillbiss Air Power Company MGP-4600 - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von DeVillbiss Air Power Company MGP-4600 reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über DeVillbiss Air Power Company MGP-4600 erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon DeVillbiss Air Power Company MGP-4600 besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von DeVillbiss Air Power Company MGP-4600 verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit DeVillbiss Air Power Company MGP-4600. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei DeVillbiss Air Power Company MGP-4600 gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.