200,000 Btu/Hr Model RM200T ARL LOGO G 004 ® IMPORTANT: Read and understand this manual before assembling, start- ing, or servicing heater. Improper use of heater can cause serious injury.
2 103607 POR T ABLE FORCED AIR HEA TER 200,000 BTU/HR • Use only kerosene or No. 1 fuel oil to avoid risk of fire or explosion. Never use gasoline, naphtha, paint thinners, alco- hol, or other highly flammable fuels.
3 103607 OWNER’S MANUAL 1. Remove all packing items applied to heater for shipment. 2. Remove all items from carton. 3. Check items for shipping damage.
4 103607 POR T ABLE FORCED AIR HEA TER 200,000 BTU/HR WARNING: Use only kero- sene or No. 1 fuel oil to avoid risk of fire or explosion. Never use gasoline, naphtha, paint thinners, alcohol, or other highly flammable fuels. Do not use heavy fuels such as No.
5 103607 OWNER’S MANUAL THEOR Y OF OPERA TION The Fuel System: The air pump forces air through the air line. The air is then pushed through the burner head nozzle. This air causes fuel to lift from the tank. A fine mist of fuel is sprayed into the combustion chamber.
6 103607 POR T ABLE FORCED AIR HEA TER 200,000 BTU/HR Item Fuel tank Air output and lint filters Air intake filter Fuel filter Spark plug Fan blades Motor WARNING: Never service heater while it is plugged in, op- erating, or hot. Severe burns and electrical shock can occur.
7 103607 OWNER’S MANUAL 1. Wrong pump pressure 2 . Dirty air output, air intake and lint filters 3. Dirty fuel filter 4. Dirt in nozzle 5. Dirty photocell lens 6.
8 103607 POR T ABLE FORCED AIR HEA TER 200,000 BTU/HR SER VICE PROCEDURES UPPER SHELL REMOVAL 1 . Remove screws along each side of heater using 5/16" nut-driver . These screws attach upper and lower shells together . 2. Lift upper shell off. 3. Remove fan guard.
9 103607 OWNER’S MANUAL FUEL FILTER 1 . Remove side cover screws using 5/16" nut-driver . 2. Remove side cover . 3 . Pull lower fuel line off the fuel valve fitting. 4. Carefully pry bushing, lower fuel line, and fuel filter out of fuel tank. 5.
10 103607 POR T ABLE FORCED AIR HEA TER 200,000 BTU/HR NOZZLE 1. Remove upper shell (see Upper Shell Removal , page 8). 2. Remove fan (see Fan , page 8). 3. Remove fuel and air line hoses from burner head. 4. Remove spark plug wire from spark plug. 5.
11 103607 OWNER’S MANUAL Figure 16 - Removing Nozzle Figure 17 - Rotor Location Sandpaper Figure 19 - Sanding Rotor Figure 18 - Gap Adjusting Screw Locations Nozzle Face Nozzle Seal Nozzle Burner Head Fuel Line Fitting Air Line Fitting SER VICE PROCEDURES Continued PUMP ROTOR (Procedure if Rotor is Binding) 1.
12 103607 POR T ABLE FORCED AIR HEA TER 200,000 BTU/HR 1 2 3 4 5 6 7 8 23 19 9 10 16 11 12 15 45 25 26 27 24 28 29 20 22 21 30 31 41 33 34 35 36 23 14 13 40 39 17 18 32 37 38 43 42 49 50 44 48 47 46 I.
13 103607 OWNER’S MANUAL P AR TS LIST RM200T This list contains replaceable parts used in your heater. When ordering parts, be sure to provide the correct model and serial numbers (from the model plate), then the part number and description of the desired part.
14 103607 POR T ABLE FORCED AIR HEA TER 200,000 BTU/HR Btu/Hr 200,000 Flame-out Control Part No. HA3003 Spark Plug Part No. HA3012 Filter Kit Part No. HA3017 Nozzle Part No. 100735-13 Rotor/Air Pump Kit Part No. HA3005 Handle Part No. HA2204 Photocell Part No.
15 103607 OWNER’S MANUAL White Black Black Blue Green Power Plug 120V/60Hz Photocell Spark Plug Ignitor Flame-Out Control B Reset Button R Red Red Motor Blue White White White White White Red Red Green Terminal Board Red Black Relay Fuel Valve Green/Yellow Thermostat WIRING DIAGRAM Note: Use only original replacement parts.
W ARRANTY AND REP AIR SER VICE WARRANTY SERVICE Should your heater require service, return it to your nearest authorized service center. Proof of purchase must be presented with the heater. The heater will be inspected. A defect may be caused by faulty materials or workmanship.
Ein wichtiger Punkt beim Kauf des Geräts Desa RM200T (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Desa RM200T noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Desa RM200T - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Desa RM200T reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Desa RM200T erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Desa RM200T besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Desa RM200T verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Desa RM200T. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Desa RM200T gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.