Benutzeranleitung / Produktwartung 3Ax-602646-xUxx des Produzenten Delta Tau
Zur Seite of 40
^1 HARDWARE REFERENCE MANUAL ^2 Quad Amp ^3 4-Axis Digital Amplifier ^4 3Ax-602646-xUxx ^5 September 24, 2003 Single Source Machine Control Power // Flexibility // Ease of Use 21314 Lassen Street Chatsworth, CA 91311 // Tel. (818) 998-2095 Fax. (818) 998-7807 // www.
Copyright Information © 2003 Delta Tau Data Systems, Inc. All rights reserved. This document is furnished for the customers of Delta Tau Data Systems, Inc. Other uses are unauthorized without written permission of Delta Tau Data Systems, Inc. Information contained in this manual may be updated from time-to-time due to prod uct improvements, etc.
Quad Amp Hardware Reference Manua l Table of Contents i Table of Contents INTRODUCTION ................................................................................................................... .................................... 1 Related Technical Doc umentation .
Quad Amp Hardware Reference Manua l Table of Contents i i Jumpers, Potentiometers, Te st Points, and LEDs ................................................................................. .............. 21 Grounding ...................................
Quad Amp Hardware Reference Manua l Introduction 1 INTRODUCTION The Delta Tau Data Systems, Inc. 4-axis Digital Amplifier (Quad Amp) is a highly compact digital amplifier and power supply, packaged together to provide four axes of bi-directional (four quadrant) torque control for a variety of AC or DC brushl ess or AC induction motors.
Quad Amp Hardware Reference Manua l Introduction 2 Quad Amp Basic Specifications Physical Specifications Size ( See Figure 1 ) • Height: 22.0 Inches • Width: 10.5 Inches • Length: 5.125 Inches (without mounting optio n) 9.031 Inches (with mounting option) Weight • 60 lb.
Quad Amp Hardware Reference Manua l Introduction 3 Main DC bus Voltage 170 VDC ( 120 VAC line i nput) (L1, L2) 300 VDC ( 208 VAC line i nput) (L1, L2, L3) 325 VDC ( 230 VAC line i nput) (L1, L2, L3) For dem o only Internal Shunt Resistor Resistance 15 Ohm Resistor power 1.
Quad Amp Hardware Reference Manua l Introduction 4 USE 1/ 4- I NCH MOUNTIN G HARDWARE ( 4 PL AC ES ) AIR FL OW Figure 1 Quad Amp Specifications Output Specifications for 120/208/230 VAC Amplifier Up to four blocks (options) can be selected in an y power combination.
Quad Amp Hardware Reference Manua l Introduction 5 Opt 5 Opt 6 Opt 7 Opt 8 Opt 9 Opt 10 Opt 11 Opt 12 Opt 13 Opt 14 Continuous HP(100%) 0.75 HP 0.56 kW 1.5 HP 1.1 kW 2 HP 1.5 kW 3 HP 2.2 kW 5 HP 3.7 kW 7.5 HP 5.6 kW 10 HP 7.5 kW 15 HP 11 kW 20 HP 15 kW 30 Hp 22.
Quad Amp Hardware Reference Manua l Introduction 6 Protection There are several layers of protection built into the am plifier, including transient voltage filters, transient surge suppressors, fuses, a flyback diode, and a variety of fault detection circuits.
Quad Amp Hardware Reference Manua l Introduction 7 Configurable Options Each Quad Amplifier is shipped with an Identifi cation Tag (see Figure 1). The identification tag is attached to the top panel of the Quad Amplifier. It indicates the rating of each axis, the AC operating voltage, and the control input voltage.
Quad Amp Hardware Reference Manua l Introduction 8 Accessories Item Description Note 3A1-602582-100 Circuit Break er 50 Amps 450 V AC 3 Phase With extern al trip 3A2-602582-100 Circuit Break er 70 Amps 250 V AC 3 Phase N A 200-602739-02 4 PWM I nput Cables 36” long cable with DB36 pin mini connectors at each end Two require d per Acc-8F.
Quad Amp Hardware Reference Manua l Getting Started 9 GETTING STARTED Receiving and Handling Inspection up on Receipt Upon the receipt of equipment, inspect all mercha ndise for any indication of damage that may have incurred during shipping and handli ng.
Quad Amp Hardware Reference Manua l Getting Started 1 0 Heat Dissipation The external mounting options (Opt3, Opt3A and Opt 3B) allow the Quad Amplifier to be installed inside a cabinet, with the Quad Amplifier h eat sink mounted external to the cabinet or in an air plenum .
Quad Amp Hardware Reference Manua l Theory of Operatio n 11 THEORY OF OPERATION Operation The Quad Amplifier is a universal 4-axis 3-phase di rect PWM drive which utilizes the latest in smart power technology from the world’s leading vendors a nd the cutting edge algorith ms of the new PMAC2 controller family.
Quad Amp Hardware Reference Manua l Theory of Operation 12 Current Sense Board The Current Sense Board has eight Hall Effect (LEM ) modules for current sense and eight on-board A/D converters that transform four channels of motor current to di gital form.
Quad Amp Hardware Reference Manua l Theory of Operatio n 13 Heat Dissipation The capability of the Quad Amplifier and the IGBT m odules is based upon the heat they can dissipate; the more quickly heat can be removed from the IGBT m odule, the more current it can handle.
Quad Amp Hardware Reference Manua l Theory of Operation 1 4.
Quad Amp Hardware Reference Manua l Installation 15 INSTALLATION Wiring the Quad Amplifier System Quad Amplifier Channel Connections The Quad Amplifier channels must be connected in a particular order for proper operation.
Quad Amp Hardware Reference Manua l Installation 1 6 Non-Standard Quad Amplifier Setup This example shows the Quad Amplifier setup with PMAC axes 1, 2, 7, and 8 are connected to first Quad Amplifier #1 and PMAC Axes 3, 4, 5 and 6 are conne cted to first Quad Amplifier #2.
Quad Amp Hardware Reference Manua l Installation 17 CONNECT TO A C C- 8 F MOT OR GROUNDS 1 23 4 WWWW VVVV UUUU MOTOR CABLES AXIS 1 AXIS 2 AX IS 3 AXIS 4 MOT OR OVERTEMP CONNE CTOR AXIS 1 AXIS 3 AXIS 4.
Quad Amp Hardware Reference Manua l Installation 18 Pin# Symbol Function Description Notes 1 Fc_A1 Input 2 Fc_C1 Input 3 Clk0+ Input A/D Conve rt Clock 4 Conv ert0+ Input A/D Convert Strobe 5 Atddaa1+.
Quad Amp Hardware Reference Manua l Installation 19 Figure 7 Quad Amp Main Circuit Wiring Diagram Main AC Input Power Connect desired main input power to input terminal s marked L1, L2, and L3 (see Figure 7).
Quad Amp Hardware Reference Manua l Installation 2 0 For 460 VAC Operation Jump pin 4 to pin 5. Power is applied to pins 1 and 8 via AC input connector C3. For 480 VAC Operation Jump pin 4 to pin 5 and pin 8 to pin 9. Power is a pplied to pins 1 and 10 via AC input co nnector C3.
Quad Amp Hardware Reference Manua l Installation 21 Bus Power Enable/Emergency Stop CAUTION: Any wiring should be attempted only after th e drive has been isol ated from the main AC supply and 10 to 12 minutes has elapsed to allow the internal bus capacitors to discharge.
Quad Amp Hardware Reference Manua l Installation 22 12 3 3 2 1 Figure 10 Logic I/O Board Jumper and L ED Locations Name Position Description Default E1-E4 IN Shield To Local Ground Open OUT E7 IN Do N.
Quad Amp Hardware Reference Manua l Installation 23 Figure 11 Current Sense Board Jumper and LED Locations Name Position Description Default E1A-E4A IN Enable Serial Fault Data, Phase A Open OUT E1B-E.
Quad Amp Hardware Reference Manua l Installation 2 4 Figure 62 Soft Start Board Jumper, Potent iometer, Test Point, and LED Locations Name Position Description Default E1 1- 2 jumper Inte rnal Power S.
Quad Amp Hardware Reference Manua l Installation 25 Grounding General It is important to follow some precautions to avoi d ground loops or unwanted electrical noise disturbances. • All signal cables must be shielded. • Two or more power wires in the same sleeve must be twisted and shielded.
Quad Amp Hardware Reference Manua l Installation 2 6 Note: The Quad Amplifier has a built-in protecti on against accidentally setting I900 (PWM frequency) too high, and exceeding the P WM input f requency rating of the power blocks. I9n6 For machine interface channel n, I9n6 must be set to 0 to select PWM output format.
Quad Amp Hardware Reference Manua l Installation 27 During this tuning process, P2Setup also determin es the commutation parameters and commands the PMAC appropriately. Power Block Option Continuous Hp Continuous Current (A) Peak Current 2 Sec (A) Max ADC Value 208/230 VAC 5 0.
Quad Amp Hardware Reference Manua l Installation 28.
Quad Amp Hardware Reference Manua l Troubleshoot i ng 29 TROUBLESHOOTING Logic Fault Detection and Fault Codes The Quad Amplifier is capable of detecting and repo rting a variety of fault conditions. These conditions are broken into two types: axis-specific and global.
Quad Amp Hardware Reference Manua l Troubleshoot ing 3 0 Note: Jumpers E1A, E1B, E2A, E2B, E3A, E3B, E4A, E4B must be installed on the current sense board so that the 4-bit faul t code can be accessed at PMAC2 Gate Array Registers. Once such a condition occurs, the PLC notifies the u ser with an on-screen message and then disables itself.
Quad Amp Hardware Reference Manua l Troubleshoot i ng 31 In the case of multiple axis-specific faults on one ax is, the higher-numbered fault shall be indicated. In the case of axis-specific faults on multiple axes, the axis with the higher-numbered fault shall be displayed along with the decimal point indicting its a xis number.
Quad Amp Hardware Reference Manua l Troubleshoot ing 32 Motor moves after a command is issued but under volt age fault comes on sh ortly after. Also, the Soft Start resistor heats up (and possibly b urns). Verify if the bus voltage sags when the motor is c ommanded t o move.
Quad Amp Hardware Reference Manua l Illustrated Repair Parts List 33 ILLUSTRATED REPAIR PARTS LIST Purpose This chapter contains the Repair Parts List (RPL) for the 4-Axis Digital Amplifier (Quad Amplifier ). The RPL identifies the customer replaceable units (CRUs) of Quad Amplifier with an illustration and a Group Assembly Parts List (GAPL).
Quad Amp Hardware Reference Manua l Illustrated Repair Parts List 3 4 Figure 12 Delta Tau Data Systems 4 Axis Digital Amplifier.
Quad Amp Hardware Reference Manua l Illustrated Repair Parts List 35 Figure And Index Number Part Number Description 1 2 3 4 5 6 7 Qty Per Assy Manu- facturer Part Number 7-1 500-602645-103 QUAD Digit.
Quad Amp Hardware Reference Manua l Illustrated Repair Parts List 3 6 Figure And Index Number Part Number Description 1 2 3 4 5 6 7 Qty Per Assy Manu- facturer Part Number -270 014-030 M03- HSM 3 Pos. Pl ug (P2) 1 Amp 1- 480700-0 -280 014-00 MF04- 0HM 4 Pos.
Ein wichtiger Punkt beim Kauf des Geräts Delta Tau 3Ax-602646-xUxx (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Delta Tau 3Ax-602646-xUxx noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Delta Tau 3Ax-602646-xUxx - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Delta Tau 3Ax-602646-xUxx reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Delta Tau 3Ax-602646-xUxx erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Delta Tau 3Ax-602646-xUxx besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Delta Tau 3Ax-602646-xUxx verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Delta Tau 3Ax-602646-xUxx. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Delta Tau 3Ax-602646-xUxx gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.