Benutzeranleitung / Produktwartung DVPDNET-SL des Produzenten Delta Electronics
Zur Seite of 32
DVPDNET -SL DeviceNet Network Scanner Application Manual.
.
DeviceNet Network Scanner DVPDNET -SL DVP-PLC Application Manual 1 W ar ning Please r ead this instruction car efully befor e use and follow th is instruction to operate the device in or der to pr event damages on the device or injuries to staff. Switch off the power befor e wiring.
DeviceNet Network Scanner DVPDNET -SL DVP-PLC Application Manual 2 3.2 Installing D VPDNET -SL and DVP-SV MPU on DIN Rail .......................................................... 7 3.3 Connecting to DeviceNet Connection Port ........................
DeviceNet Network Scanner DVPDNET -SL DVP-PLC Application Manual 3 1 Introduction 1. T o ensure correct inst allation and operation of DVP DNET -SL, please read this chapter carefully before usi ng your DVPDNET -SL. 2. This chapter only provides introductory i nformation on DVPDNET -SL.
DeviceNet Network Scanner DVPDNET -SL DVP-PLC Application Manual 4 1.3 I/O Scan List Item Explanation Software screen Scan T able Before DVPDNET -SL st arts its operation, you have to configure it s scan list through the configuration sof t ware. The scan list is a list consisting of the information of slave devices with data, e.
DeviceNet Network Scanner DVPDNET -SL DVP-PLC Application Manual 5 Electrical specification V oltage 1 1 ~ 25 VDC supplied by the power cable in the network Current 28mA (typical), 125mA impulse c.
DeviceNet Network Scanner DVPDNET -SL DVP-PLC Application Manual 6 3. Power , MS, NS LED 8. Function switch 4. DIN rail clip 9. DeviceNet conne ction p ort 5. Digital indicator 2.3 DeviceNet Connection Port The connector is used on t he connection to Device Net.
DeviceNet Network Scanner DVPDNET -SL DVP-PLC Application Manual 7 OFF When the slave is of f-line, the I/O data in the buffer area will be cl eared. IN1 Reserved Note: z Please set up the function switch when the power is switched off. After the setup is completed, re-power DVPDNET-SL.
DeviceNet Network Scanner DVPDNET -SL DVP-PLC Application Manual 8 Open the DIN rail clip on DVP-SV and DVPDNET -SL . Insert DVP-S V and DVPDNET -SL onto the DIN rail. Clip up the DIN rail clips on DVP-SV and DVPDNET -SL to fix DVP-SV and DVPDNET -SL on the DIN rail, as shown below .
DeviceNet Network Scanner DVPDNET -SL DVP-PLC Application Manual 9 Mapped D registers DVPDNET -SL index Output mapping Input mapping 1 D6250 ~ D6497 D6000 ~ D6247 2 D6750 ~ D6997 D6500 ~ D6747 3 D7250.
DeviceNet Network Scanner DVPDNET -SL DVP-PLC Application Manual 10 PORT2 PORT1 DeviceNet VFD-B DVP28SV DVPDN ET DVP28SV RUN STOP L N 0V R T U - D N E T D V P - 1 6 S P L N 0V X0 X1 Y0 DVP-PS01 DVP-1 6SP RTU-DNET IFD9502 DVP-PS0 1 DVPDNET-SL RS-232 Node 02 Node 01 Node 03 De vice Ne t netw ork confi gurat i on tool 2.
DeviceNet Network Scanner DVPDNET -SL DVP-PLC Application Manual 11 (3) Set up the communication pa rameters in the PC and DVP-SV , e.g. the communication port, address, baud rate and communication format.
DeviceNet Network Scanner DVPDNET -SL DVP-PLC Application Manual 12 (5) Click on “OK”, and DeviceNetBuilder will start to scan the e ntire network. (6) If the bar on the dialog box does not progress, it mean s the connection between the PC and DVP-SV is abnormal, or there are other program s also using the CO M port on the PC.
DeviceNet Network Scanner DVPDNET -SL DVP-PLC Application Manual 13 (8) Click on “IO Configure … ” button in “Nod e Conf iguration” dialog box, and you will then see “RTU Configuration” page. (9) Click on “Scan IO”, and the "Warning” dialog box will appear.
DeviceNet Network Scanner DVPDNET -SL DVP-PLC Application Manual 14 (11) Double click on RTU-DNE T icon, and you will then see “RTU Setup” dial og box.
DeviceNet Network Scanner DVPDNET -SL DVP-PLC Application Manual 15 Item Function Default DIDO Output Points (Y) The digital ou tput point s shall be 8’ s multiple. The n umber will be regarded as 8 when it is less than 8 and rega rded as 16 when it is bigger than 8 but less than 1 6.
DeviceNet Network Scanner DVPDNET -SL DVP-PLC Application Manual 16 (16) Confirm the pa ram eters and I/O data in VFD-B a nd cli ck on “OK”. 2. Configuration of DVPDNET -SL (1) Double click on DNET Scanner (node 01), and th e “Scan Module Configur ation.
DeviceNet Network Scanner DVPDNET -SL DVP-PLC Application Manual 17 (3) Confirm all the settings and cli c k on “OK”. Nex t, downlo ad the configuration to DVPDNET -SL. If DVP-SV is in RUN mode while you are downloadin g the configuration, a “W arning” dialog box will appear .
DeviceNet Network Scanner DVPDNET -SL DVP-PLC Application Manual 18 Slave → DVPDNET -SL Register in DVPDNET -SL Devices in slave D6037H DI/DO module X0 ~ X7 on DVP-16SP D6037L N/A D6038H S tatus of .
DeviceNet Network Scanner DVPDNET -SL DVP-PLC Application Manual 19 1. PLC program: MO V H2 D 6288 M100 0 MO V D60 38 K4M 20 M8 MOV H1 D6288 MO V H01 00 D62 87 MO V H00 00 D62 87 MO V D60 37 K4M 0 M9 M8 M9 M20 M21 END Send t he co nte nt i n D6037 to K4 M0.
DeviceNet Network Scanner DVPDNET -SL DVP-PLC Application Manual 20 6 Sending Explicit Message from Ladder Diagram DVPDNET -SL supports the sending of explicit messages through WPL programs.
DeviceNet Network Scanner DVPDNET -SL DVP-PLC Application Manual 21 1. S tructure of request message See the table below: Request Message PLC device 15 14 13 12 11 10 98 7 6 5 4 3 2 1 0 D6250 ReqID Co.
DeviceNet Network Scanner DVPDNET -SL DVP-PLC Application Manual 22 S tatus Explanation 0 No explicit message is sent out. 1 The communication of explicit message is su ccessful. 2 The explicit message is being sent out. 3 Error: No response from the t arget equipment.
DeviceNet Network Scanner DVPDNET -SL DVP-PLC Application Manual 23 Compulsory settings in IFD9502 Parameter Set value Explanation Node address 02 Set the node address of IFD9502 to “02". Baud rate 500kbps Set the communication speed of IFD9502 and bus to “500kbp s”.
DeviceNet Network Scanner DVPDNET -SL DVP-PLC Application Manual 24 (4) Program explanations: In the beginning of the program, clear the response message editing area and requ est message editing area to 0.
DeviceNet Network Scanner DVPDNET -SL DVP-PLC Application Manual 25 Parameter Set value Explanation 02-01 03 The operation commands are operated on the comm unication interface. Operation by keys is valid. 09-00 01 Communication address of VFD-B: 01 09-01 03 Baud rate: 38,400 09-04 03 Modbus RTU mode.
DeviceNet Network Scanner DVPDNET -SL DVP-PLC Application Manual 26 editing area to 0. When M1 = On, DVPDNET -SL will send out re qu est me ssage. Write 00 04Hex into Class 99 >> Instance 1 >> Attribue 2 of the target equipm ent (node address: 02 ).
DeviceNet Network Scanner DVPDNET -SL DVP-PLC Application Manual 27 Corresponding nodes on th e netwo rk PLC device b15 b14 b13 … b1 b0 D6032 Node 15 Node 14 Node 13 … Node 1 Node 0 D6033 Node 31 .
DeviceNet Network Scanner DVPDNET -SL DVP-PLC Application Manual 28 LED status Indication How to correct Red light blinking Error in com munication Check the digital indicator and elimin ate the error . Red light on Network error; cannot check duplicate ID; bus-off (che k the digital indicator) 1.
DeviceNet Network Scanner DVPDNET -SL DVP-PLC Application Manual 29 Code Indication How to correct F2 Low voltage i s detected. Check if the power of DVPDNE T -SL a nd PLC MPU is normal. F3 Entering test mode Switch IN1 from On to Off and re-power DVPDNET -SL.
DeviceNet Network Scanner DVPDNET -SL DVP-PLC Application Manual 30 MEMO.
Ein wichtiger Punkt beim Kauf des Geräts Delta Electronics DVPDNET-SL (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Delta Electronics DVPDNET-SL noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Delta Electronics DVPDNET-SL - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Delta Electronics DVPDNET-SL reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Delta Electronics DVPDNET-SL erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Delta Electronics DVPDNET-SL besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Delta Electronics DVPDNET-SL verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Delta Electronics DVPDNET-SL. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Delta Electronics DVPDNET-SL gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.