Benutzeranleitung / Produktwartung 3VG79 des Produzenten Dayton
Zur Seite of 16
Operating Instructions & Parts Manual 3VG79 Dayton Portable For ced Air Heaters Description Dayton Model 3VG79 is a 200,000 Btu/Hr heater . This heater uses Kerosene or #1 fuel oil for combustion and electricity to run the motor .
Dayton Operating Instructions and Parts Manual 2 Dayton Portable Oil-Fir ed Heaters ® 3VG79 Lower Shell Hot Air Outlet Fan Guard Fuel T ank Flame-out Control Reset Button Side Cover Fuel Cap Figure 2.
Dayton Operating Instructions and Parts Manual 3 Model 3VG79 Version B - For Reduction G016.J ® General Safety Information Make certain you read and understand all warnings. Keep these instructions for refer ence. They are your guide to safe and proper operation of this heater .
Dayton Operating Instructions and Parts Manual 4 Dayton Portable Oil-Fir ed Heaters ® 3VG79 General Safety Information (Continued) Theory of Operation Fuels Use only kerosene or No. 1 fuel oil to avoid risk of fire or explosion. Never use gasoline, naphtha, paint thinners, alcohol, or other highly flammable fuels.
Dayton Operating Instructions and Parts Manual 5 Model 3VG79 Version B - For Reduction G016.J ® Front Handle Rear Handle Wheel Support Frame Hot Air Outlet Fuel T ank Flange Screw Air Inlet Assembly This model is furnished with wheels and handles. Wheels, handles, and the mounting hardwar e are found in the shipping carton.
Dayton Operating Instructions and Parts Manual 6 Dayton Portable Oil-Fir ed Heaters ® 3VG79 FAN IMPORT ANT : Remove fan from motor shaft before r emoving motor from heater . The weight of the motor resting on the fan could damage the fan pitch. 1. Remove upper shell (See Figure 6).
Dayton Operating Instructions and Parts Manual 7 Model 3VG79 Version B - For Reduction G016.J ® Figure 10 - Adjusting Pump Pr essure Pressure Gauge Side Cover Bushing, Lower Fuel Line, and Fuel Filter Figure 11 - Fuel Filter Removal Fuel V alve Fitting High V oltage.
Dayton Operating Instructions and Parts Manual 8 Dayton Portable Oil-Fir ed Heaters ® 3VG79 Air Line Hose Screw Combustion Chamber Burner Head Spark Plug Wire Spark Plug Fuel Line Hose NOZZLE 1. Remove upper shell (See page 6). 2. Remove fan (See page 6).
Dayton Operating Instructions and Parts Manual 9 Model 3VG79 Version B - For Reduction G016.J ® Sandpaper Gap Adjusting Screw Gap Adjusting Screw .003"/.004" Gap Measured With Feeler Gauge Rotor Blade 5. Remove pump plate. 6. Remove rotor , insert, and blades.
Dayton Operating Instructions and Parts Manual 10 Dayton Portable Oil-Fir ed Heaters ® 3VG79 For Replacement Parts, call 1-800-323-0620 24 hours a day - 365 days a year Please provide following infor.
Dayton Operating Instructions and Parts Manual 11 Model 3VG79 Version B - For Reduction G016.J ® Ref. Part 2E510D 2E511D No. Description Number Qty . Qty .
Dayton Operating Instructions and Parts Manual 12 Dayton Portable Oil-Fir ed Heaters ® 3VG79 Please provide following information: -Model number -Serial number (if any) -Part description and number as shown in parts list Address parts correspondence to: Grainger Parts Operations P .
Dayton Operating Instructions and Parts Manual 13 Model 3VG79 Version B - For Reduction G016.J ® 3VG79 Replacement Parts List Ref. Part No. Description Number Qty .
Dayton Operating Instructions and Parts Manual 14 Dayton Portable Oil-Fir ed Heaters ® 3VG79 Replacement Parts List for Handle and Wheel Group Ref. Part No.
Dayton Operating Instructions and Parts Manual 15 Model 3VG79 Version B - For Reduction G016.J ® T roubleshooting Chart Possible Cause(s) Corrective Action Never service heater while it is plugged in, operating, or hot. Severe burns and electrical shock can occur .
Dayton Operating Instructions and Parts Manual 16 Dayton Portable Oil-Fir ed Heaters ® 3VG79 Manufactured for Dayton Electric Mfg. Co. Niles, Illinois 60714 103536-01 Rev . B 3/97 Version B - For Reduction G016.J ® Limited Warranty Dayton One-Year Limited Warranty.
Ein wichtiger Punkt beim Kauf des Geräts Dayton 3VG79 (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Dayton 3VG79 noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Dayton 3VG79 - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Dayton 3VG79 reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Dayton 3VG79 erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Dayton 3VG79 besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Dayton 3VG79 verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Dayton 3VG79. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Dayton 3VG79 gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.