Benutzeranleitung / Produktwartung F732 des Produzenten Datalogic Scanning
Zur Seite of 41
F732 WIZARD™ User’s Manual.
F732 WIZARD™ User’s Manual.
F732 W IZ A RD™ USER'S M ANUAL.
DATALOGIC S.p.A. Via Candini 2 40012 - Lippo di Calderara di Reno Bologna - Italy Formula 732 W izard™ - User's Manual Ed.: 06/01 ALL RI GHTS RESERVED Datalogic reserves the right to mak e modifications and improvements w ithout prior notification.
iii CONTENTS 1 GENERAL INFORMA TION ................................... 1 1.1 F732 W IZARD™ Terminal Description ................. 1 1.2 Downloading Easy Gen™ Demo............................ 3 1.3 Application Development Programs ................
iv.
GENERAL I NFORMATI ON 1 Ed.: 06/ 01 1 1 GENERA L INFORM A TION 1.1 F732 WIZARD™ TERMINAL DESCRIPTION For vast majority of small businesses and retailers, the complete Formula Wizard™ package represents the simplest and most cost-effective solution for entering the world of bar code data acquisition.
F732 W IZARD™ 1 2 Ed.: 06/ 01 The Easy Gen™ Demo Version w ith five ready-to-use example applications can be dow nloaded from the Datalogic w eb site free of charge.
GENERAL I NFORMATI ON 1 Ed.: 06/ 01 3 The F732 terminal has an LCD graphic display of 16 characters by 4 lines plus a line in the upper part of the display for the programmable icons: FORMUL A 73 2 WIZAR D POCKET LASER TERM DA T ALOGIC S.
F732 W IZARD™ 1 4 Ed.: 06/ 01 Easy Gen™ A pplication Generator By using the EasyG en™ software, developers can easily and quickly build personalized applications of average complexity in a W indows environment. • EasyGen™ (Easy Application Generator Package)* order nr.
GENERAL I NFORMATI ON 1 Ed.: 06/ 01 5 1.5 CONTENT S OF PA CKING The F732 terminal package includes: − nr. 1 F732 terminal complete with batteries; − nr. 1 cradle F952 with pow er supply; − nr. 1 cable 90A054000 for serial connection; − nr. 1 user's manual − nr.
F732 W IZARD™ 1 6 Ed.: 06/ 01 1. 6 TE R MIN A L ID EN TI FI CA TION SER 12 345 6789 COD 9414 04020 MOD F732 /B 128K Datalo gic S pA 00 /01 CAUTI ON SER 123456789 COD 941404020 MOD F732/B 128K Dat al.
SAFETY REGULATIONS 2 Ed.: 06/ 01 7 2 SA FETY REGULA TIONS NOTE Read this manual carefully before performing any type of connection or repair on the F732 terminal. The user is responsible for any dam ages caused by incorrect use of the equipment or by inobservance of the indication supplied in this manual.
F732 W IZARD™ 2 8 Ed.: 06/ 01 2.2 LA SER SA FETY The laser light is visible to the human eye and is emitted from the window indicated in the figure. SER 12345 67 89 COD 9414 04020 MOD F73 2/B 128 K Data logic SpA 00/ 01 CAUT ION AVOID EXPOS URE-LASER LIGHT IS EMITTED FROM THIS APERTURE 680 nm L ASER 1.
SAFETY REGULATIONS 2 Ed.: 06/ 01 9 ID F E LUCE LASER NON FI SSARE IL FA S CIO APPARECCHIO LASER DI CLASSE 2 MASSI M A POTENZA D'USCITA: LUNGHEZZA D'ONDA EMESSA: CONFORME A EN 60825 (1993) LASERSTRAHLUNG NICHT IN DEN STRAHL BLI CKEN PRODUKT DER LASERKLASSE 2 MAXIMA LE AUSGANGSLEI STU NG: W ELLENLÄGE: ENTS PR.
F732 W IZARD™ 2 10 Ed.: 06/ 01 ITALIA NO Le seguenti informazioni vengono fornite dietro direttive delle autorità internazionali e si riferiscono all’uso corretto del terminale.
SAFETY REGULATIONS 2 Ed.: 06/ 01 11 A CHTUNG Jegliche Änderungen am Gerät sowie Vorgehensweisen, die nicht in dieser Betriebsanleitung beschreiben werden, können ein gefährliches Laserlicht verursachen.
F732 W IZARD™ 2 12 Ed.: 06/ 01 ESPAÑOL Las informaciones siguientes son presentadas en conformidad con las disposiciones de las autoridades internacionales y se refieren al uso correcto del terminal.
SAFETY REGULATIONS 2 Ed.: 06/ 01 13 2.3 FCC COMPLIA NCE - INFORMA TION FOR THE USER CA UTION This device com plies with PAR T 15 of the FCC R ules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference which may cause undesired operation.
F732 W IZARD™ 3 14 Ed.: 06/ 01 3 CONNECTION 3.1 CRA DLE To make the F732 terminal operative, it is necessary to insert it in the Formula 952 Transceiver charger cradle which has prev iously been connected to the pow er supply and to a host computer with an av ailable RS-232 serial line.
CONNECTION 3 Ed.: 06/ 01 15 The follow ing figure describes the F952 cradle: A B POWER +9V RS-232 PORT S/N 201950 0252 Mod. F9 52 Code n. 140901 450 Datalogic S pA 99/10 C D E Key: A) Cradle on/off sw.
F732 W IZARD™ 3 16 Ed.: 06/ 01 3.2 CONNECTION T O T HE HOST COM PUT ER CA UTION Before proceeding with this phase, m ake sure that both the computer and the F732 terminal are switched off.
CONNECTION 3 Ed.: 06/ 01 17 Power S upply 94A054 000 ( 94A054 010) A B C Key: A) Host computer B) Single cradle F952 C) Power supply.
F732 W IZARD™ 3 18 Ed.: 06/ 01 3.3 CONNECTION CABLES Several types of cables are av ailable depending on the type of computer and connection. The follow ing cables are listed with their order number.
USE AND O PERATION 4 Ed.: 06/ 01 19 4 USE AND OPERA TION W hen an EasyGen™ application program is loaded onto the F732 terminal (either a Demo ex ample or an application developed w ith EasyGen™ for Formula) to launch it, it is necessary to ex tract the F732 terminal from the cradle and press <SHIFT> and then the <UP AR ROW > key.
F732 W IZARD™ 4 20 Ed.: 06/ 01 4 . 1 L O AD IN G AP P L I C AT I O N P RO G R AM S If you are using application programs for Easy Gen™ (see par. 1.2 or par. 1.3) refer to chapter 6 of the EasyGen™ User's M anual. If you are using applications developed w ith DS for Formula (see par.
USE AND O PERATION 4 Ed.: 06/ 01 21 4.3 DESCRIPTION OF KEYS Although EasyGen™ for Formula allows assigning customized functions to function keys, there are some standard functions common to all applications because they are implemented in the interpreter software.
F732 W IZARD™ 4 22 Ed.: 06/ 01 ESC KEY: used in the “Data display ” mode. SHIFT KEY : Enables the entry of alphabetical characters (written in white on the key board) when followed by the pressing of a numeric key : for example if you w ant to enter the alphabetical character “A”, y ou have to press <SHIFT>+<7>.
USE AND O PERATION 4 Ed.: 06/ 01 23 BACKSPACE KEY: deletes the last character entered. SPACE KEY : allow s the introduction of a blank space. If the <SHIFT > has been pressed previously, the choice of alternative characters w ill be activated. ENTER KEY: allows v alidation of what has been typed.
F732 W IZARD™ 4 24 Ed.: 06/ 01 4.4 DOWNLOA DING DA TA TO HOST Data can be dow nloaded from the terminal to the host PC in different way s, depending on the application loaded: − automatically, by .
MAINTE NANCE 5 Ed.: 06/ 01 25 5 MAINTENA NCE NOTE Rechargeable battery packs (NiCd) are not initially charged. Therefore the first operation to perform is to charge them in the appropriate cradle. See chapter 3 and the following paragraph "Charging the Batteries".
F732 W IZARD™ 5 26 Ed.: 06/ 01 Recharging should be made after using the terminal until the batteries are nearly flat. A TTENTI ON When the F732 terminal display window shows the message "BATTERY LOW", wait until the F732 term inal is turned off before inserting it in the cradle.
MAINTE NANCE 5 Ed.: 06/ 01 27 5.2 REPLA CING T HE BA TT ERIES A TTENTI ON Before proceeding, ensure that the terminal is switched off and that the data it contains has been downloaded onto the host computer. To replace the batteries correctly, proceed as follow s.
F732 W IZARD™ 5 28 Ed.: 06/ 01 3- Replace the battery pack, making sure the batteries are inserted in the right direction as indicated on the cover. 4- Close the battery cover and tighten the screw s. NOTE Dispose of used batteries in accordance with the relevant laws in force.
TROUBL ESHOOTIN G 6 Ed.: 06/ 01 29 6 TROUBLESHOOTING PROBLEM CAUSE REMEDY Flat batteries. Recharge terminal. W hen the <SCAN> button is pressed the terminal does not come on. Batteries completely flat or broken. Replace batteries. Flat batteries.
F732 W IZARD™ 6 30 Ed.: 06/ 01 PROBLEM CAUSE REMEDY The terminal w ill not load the application program. The terminal already contains an application program. Follow instructions to cancel the application. The application loaded is not suitable for the terminal in use.
TECHNIC AL FEATUR ES 7 Ed.: 06/ 01 31 7 TECHNICA L FEA TURES Optical Light source laser scanner, VLD source, 670 nm Scan rate 36 ± 3 scan/sec Minimum resolution 0.15 mm (5.90 mils) Skew angle ± 65° Pitch angle ± 55° Depth of field 3 to 70 cm (1.18 to 27.
F732 W IZARD™ 7 32 Ed.: 06/ 01 Phy sical Technology S M T ( S u r f a c e M ounting Technology) Dimensions (Lx W xH) 165 x 56 x 32 mm (6.49 x 2.20 x 1.
TECHNIC AL FEATUR ES 7 Ed.: 06/ 01 33 Programming Operating modes bootstrap loader application program Transmission F952 interface via optical transceiver w ith serial protocol Cradle-Host interface R.
F732 W IZARD™ A 34 Ed.: 06/ 01 A F732 PRODUCTS A ND A CCESSORIES Formula 732 Terminals − Formula 732 Pocket Laser Terminal Hand-held programmable laser micro-terminal. Cradles − Formula 952 Transceiver charger Battery charger and optical transceiver for connections between terminal and host computer in RS -232.
DATALOGIC S.p.A., Via Candini, 2 40012 - Lippo di Calderara Bologna - Italy dichiara che declares that the déclare que le bescheinigt, daß das Gerät declare que el F732, Wizard Laser Terminal e tut.
Ein wichtiger Punkt beim Kauf des Geräts Datalogic Scanning F732 (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Datalogic Scanning F732 noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Datalogic Scanning F732 - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Datalogic Scanning F732 reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Datalogic Scanning F732 erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Datalogic Scanning F732 besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Datalogic Scanning F732 verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Datalogic Scanning F732. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Datalogic Scanning F732 gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.