MODEL 2100R & 2200R Engine Gages Read Instructions Carefully ! !.
Saf ety Instructions This instrument was manuf actured and tested according to the applicable technical standards . It complies with all the safety regulations as shipped from the f actory . Installation and star tup must be performed by skilled personnel.
! ! T ABLE OF CONTENTS P age 1. Saf ety Instructions 2 2. Model Encodement 3 3. T echnical Specifications 3.1 Electrical 5 3.2 Mechanical 8 3.3 Environmental 9 4.
3 2. MODEL ENCODEMENT (f or 2100R/2200R series) 2111RXX-YYYY ZZ Model Numbers 2111 T emperature 2112 Fuel 2113 Pressure 2114 V oltage 2211 T emperature/Hour 2212 Fuel/Hour 2213 Pressure/Hour 2214 V ol.
4 R = case (round) XX = v oltage (DC v oltages only) YYYY = sequential number code describes gage’ s f actor y programming ZZ = ar twork code (OO = Cur tis) !.
5 3. TECHNICAL SPECIFICA TIONS 3.1 Electrical Operating V oltage Model Series 2100R and 2200R are availab le in either 12VDC or 24VDC (negative g round systems only) Operating V oltages (Models 2111R, 2112R, 2113R and 2211R, 2212R, 2213R) Model Minimum Nominal Maximum 12V 9.
Operating Current T otal system current is a function of the voltage, sender type, displa y mode, and the gage’ s factory programming. T ypical operating currents (not including the current to drive the sender) v ar y from 16-55 mA, f or 12V models , depending on model number .
Output signal trigger point (lower) First LED Second LED Output signal trigger point (upper) Ninth LED T enth LED Output signal format—(upper and lower independently set) 0-5 V 5-0 V* LED flashing m.
Damping and Hysteresis Tr ansducer po wer modulation (XPM) Used to reduce current in sender circuit Output signal f ormat Outputs are capable of sinking or sourcing up to 1mA, maximum (50 µ A maximum is standard) The 5V -0 output signal format is fully compatible with the Cur tis Model 1178 relay module.
Bezel Material Aluminum, blac k anodized Hardware U clamp (1) (Individually box ed 4 mm lock washers (2) un it s ) F emale 1/4 inch fast-on connectors (up to 6) 4 mm knurled thumbnuts (2) Hardware U clamp (1) (OEM bulk pac ked) 4 mm lock w ashers (2) 4 mm hex n uts (2) 3.
Vibration Meets SAE J 1378 March 83. Double amplitude of 1.53 mm with frequency sw eep from 10-80-10 Hz (20 g max) at intervals of 1 minute. Humidity 95% RH (non-condensing) at +38C Wa ter/dust immunity F ace IP63 Rear IP50 Salt spra y (fog) ASTM B 117-73 as per SAE J1810, section 4.
4. INST ALLA TION Te r m inal Assignment f or Models 2111R, 2112R, 2113R 1 Sender in 2B attery + 3G round 4 Sender low (optional: for use with two wire senders) 5 Output signal (upper) 6 Output signal.
Te r minal Assignment f or Model 2114R 1 Not Connected ** 2B attery + 3G round 4 Not Connected** 5 Output signal (upper) 6 Output signal (lower) Te r minal Assignments f or Models 2211R, 2212R, 2213R .
Te r minal Assignments f or Model 2214R 1 Not connected*** 2B attery + 3G round 4 Hourmeter enable*** 5 Output signal (upper) 6 Output signal (lower) * Options terminal can be factory programmed to fu.
5. TR OUBLESHOO TING The follo wing checklist should help y ou to trou- b leshoot an y problems with the instrument. T urning the instrument off and then on again after about 10 seconds may solv e the prob lem in the simplest cases. Make sure to observe the saf ety instructions in Section 1.
6. MAINTENANCE Cur tis 2100R & 2200R Series Engine Gages are not serviceable in the field. Units returned to the f actory within the warranty period will be replaced without charge.
Guarantee - These Curtis Instr uments’ products are guaran- teed against defects in w orkmanship and material for a period of three years , or as defined in the individual product literature, from date of shipment from our factory , when applied in a prop- er application within specified ratings.
CURTIS INSTRUMENTS, INC. 200 Kisco A venue, Mt. Kisco, NY 10549 T el. (914) 666-2971 • FAX (914) 666-2188 53018 REV A 10/97.
Ein wichtiger Punkt beim Kauf des Geräts Curtis 2200R (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Curtis 2200R noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Curtis 2200R - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Curtis 2200R reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Curtis 2200R erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Curtis 2200R besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Curtis 2200R verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Curtis 2200R. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Curtis 2200R gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.