Benutzeranleitung / Produktwartung Architectural Area Luminaire des Produzenten Cooper Lighting
Zur Seite of 24
T alon Ar chitectural Ar ea Luminair e.
TALON VERSATILE PERFORMANCE Talon’s ingenious blend of performance and versatility allows application specific illumination by way of fourteen [14] high efficiency, field rotatable optical systems.
SITE + PARKING | ROADWAY | PATH OF EGRESS IMPENETRABLE FORM Coupling precise mechanical design with premium quality materials, the Talon site light is constructed to sustain the rigors of outdoor operation.
3 4 PERFORMANCE + VERSATILITY MAXIMIZE SITE UNIFORMITY Add sparkle to your site and maximize pole spacings with sag glass optical systems offered in both cutoff and semi-cutoff configurations. For applications mandating full cutoff, choose from a complete offering of flat glass vertical lamp solutions.
LEADING SPILL CONTROL The Spill Light Eliminator [SL] optic is the industry leader in effective spill light control, eliminating light beyond one [1] mounting height behind the pole with no sacrifice in forward illumination. Used along site perimeters and property lines, the Spill Light Eliminator keeps the light inside and the darkness out.
5 6 AUTOMOTIVE SOLUTIONS.
OUTDOOR SITE LIGHTING THAT ENGAGES CUSTOMER AWARENESS. Exterior site lighting provides the first impression of an automotive dealership and is an outward expression of image. During daytime hours the exterior site lighting fixture form should be selected to lend focus to dealership architecture and branding.
7 8 QUALITY + DURABILITY DURABLE CAST CONSTRUCTION Low-copper alloy die-cast aluminum construction offers corrosion resistance while precise tolerance control ensures tight nesting of the door and housing.
CONFIDENCE-INSPIRING QUALITY BEYOND THE SUM OF ITS PARTS. From the stainless steel hinges to the rugged housing, every detail of the Talon construction is precisely designed with industry leading craftsmanship.
9 10 CONTROL + EFFICIENCY 0° [nadir] 180° UH Back Forward Uplight 30° 30° 60° 60° 80° 80° 90° 90° 100° 100° UL UL BVH FVH BH FH BM FM BL FL LUMINAIRE CLASSIFICATION The IESNA’s revised Luminaire Classification System [TM15-07 revised] creates a new basis of measurement for site lighting visibility and adjacent property interaction.
STEPPING UP TO THE CHALLENGE. As visual research advances so too the core understanding of how light interacts with surrounding communities and nocturnal env ironments.
.
.
13 14 MOUNTING Extruded 8" [TLM Talon Medium] or 10 1/2" [TLL Talon Large] aluminum arm includes internal bolt guides allowing for easy positioning of fixture during installation to pole or wall surface. Standard single carton packaging of housing, square pole arm and round pole adapter for contractor friendly arrival of product on site.
FINISH Housing and arm finished in a 5 stage premium TGIC polyester powder coat paint, 2.5 mil nominal thickness for superior protection against fade and wear. Standard colors include black, bronze, grey, white, dark platinum, and graphite metallic. RAL and custom color matches available.
15 16 OPTIONS + ACCESSORIES ARM MOUNT Standard 8" [TLM] or 10 1/2" [TLL] extruded aluminum arm features internal bolt guides for twin support rods. Round pole mounting accommodated by utilizing provided round pole adapter between the fixture arm and pole shaft.
OPTIONS [Factory installed and shipped complete with luminaire] Electrical F =Single Fuse [120, 277 or 347V] FF =Double Fuse [208, 240 or 480V] Q =Quartz Restrike EM =Quartz Restrike w/Delay [Also Str.
17 18 STEEL POLES + BRACKETS ORDERING INFORMATION SAMPLE NUMBER: RSS4A20SFM2XG ISOTACH WIND MAP This map has been included to aid in pole selection with regard to geographic location.
FROM ANCHOR BOLTS TO LUMINAIRE AND EVERYTHING IN BETWEEN. Cooper Lighting offers a comprehensive line of steel and aluminum poles, brackets and mounting accessories to complete your sit e lighting application. Visit www.mcgraw-edison.com to view McGraw-Edison’s entire collection of mounting options.
19 20 ALUMINUM POLES + PHOTOMETRICS ALUMINUM POLES [Specification Features] ROUND STRAIGHT ALUMINUM [RSA] Fixture Mounting Drilled or Tenon [Must specify]. Shaft 6005-T6 aluminum alloy with polished finish. Handhole Flush reinforced 2 3/8" x 4 1/2" for 4" shafts.
PHOTOMETRICS [Complete IES files available at www.cooperlighting.com] FOOTCANDLE TABLE Select mounting height and read across for footcandle values of each isofootcandle line. Distance in units of mounting height. Mounting Footcandle Values for Height Isofootcandle Lines AB C D E 175W [3V/AS] 15' 1.
21 22 TLM TALON MEDIUM ORDERING INFORMATION SAMPLE NUMBER: TLM-400-MH-MT-3F-FG-BK-HS VOLTAGE 5 120 =120V 208 =208V 240 =240V 277 =277V 347 =347V 480 =480V DT =Dual-Tap 6 MT =Multi-Tap 6 TT =Triple-Tap.
TLL TALON LARGE ORDERING INFORMATION SAMPLE NUMBER: TLL-1000-MH-5T-SL-FG-BK VOLTAGE 4 120 =120V 208 =208V 240 =240V 277 =277V 347 =347V 480 =480V DT =Dual-Tap 5 MT =Multi-Tap 5 TT =Triple-Tap 5 5T =5-.
Cooper Lighting Customer First Center 1121 Highway 74 South Peachtree City , GA 30269 P: 770-486-4800 F: 770-486-4801 www .cooperlighting.com International Sales, USA Cooper Lighting 1121 Highway 74 S.
Ein wichtiger Punkt beim Kauf des Geräts Cooper Lighting Architectural Area Luminaire (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Cooper Lighting Architectural Area Luminaire noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Cooper Lighting Architectural Area Luminaire - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Cooper Lighting Architectural Area Luminaire reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Cooper Lighting Architectural Area Luminaire erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Cooper Lighting Architectural Area Luminaire besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Cooper Lighting Architectural Area Luminaire verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Cooper Lighting Architectural Area Luminaire. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Cooper Lighting Architectural Area Luminaire gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.